{"query":{"parameter":"zinc","place":"US-MS","medium":null,"statistic":null,"kind":null},"searched":{"places":["US-MS","US"],"parameter_keys":["cas:7440-66-6","name:arsenic, cadmium (h), copper (h), lead (h), mercury, zinc","name:arsenic, cadmium (h), copper (h), lead (h), zinc","name:cadmium (h), copper (h), mercury, lead (h), zinc","name:chemical oxygen demand, arsenic, radium (dissolved and total, uranium, zinc","name:iron, nickel (h), zinc","name:total zinc","name:total zinc (freshwater","name:zinc-65","cas:7646-85-7","cas:557-21-1","name:zinc extractible","cas:1314-84-7","name:zinc - total","name:zinc, total"],"names_matched":[["zinc","cas:7440-66-6"],["arsenic cadmium h copper h lead h mercury zinc","name:arsenic, cadmium (h), copper (h), lead (h), mercury, zinc"],["arsenic cadmium h copper h lead h mercury zinc h","name:arsenic, cadmium (h), copper (h), lead (h), mercury, zinc"],["arsenic cadmium h copper h lead h zinc","name:arsenic, cadmium (h), copper (h), lead (h), zinc"],["arsenic cadmium h copper h lead h zinc h","name:arsenic, cadmium (h), copper (h), lead (h), zinc"],["cadmium h copper h mercury lead h zinc","name:cadmium (h), copper (h), mercury, lead (h), zinc"],["cadmium h copper h mercury lead h zinc h","name:cadmium (h), copper (h), mercury, lead (h), zinc"],["chemical oxygen demand arsenic radium dissolved and total uranium zinc","name:chemical oxygen demand, arsenic, radium (dissolved and total, uranium, zinc"],["chemical oxygen demand arsenic radium dissolved and total uranium zinc h","name:chemical oxygen demand, arsenic, radium (dissolved and total, uranium, zinc"],["iron nickel h zinc","name:iron, nickel (h), zinc"],["iron nickel h zinc h","name:iron, nickel (h), zinc"],["total zinc","name:total zinc"],["total zinc","name:total zinc (freshwater"],["total zinc freshwater","name:total zinc"],["total zinc freshwater","name:total zinc (freshwater"],["total zinc marine","name:total zinc"],["total zinc marine","name:total zinc (freshwater"],["zinc 65","name:zinc-65"],["zinc chloride","cas:7646-85-7"],["zinc cyanide","cas:557-21-1"],["zinc cyanide zn cn 2","cas:557-21-1"],["zinc extractible","name:zinc extractible"],["zinc phosphide","cas:1314-84-7"],["zinc phosphide when present at concentrations 10","cas:1314-84-7"],["zinc phosphide zn3 p2","cas:1314-84-7"],["zinc phosphide zn3p2","cas:1314-84-7"],["zinc total","name:zinc - total"],["zinc total","name:zinc, total"]],"match":"exact+contains","order":"The place's own instruments first, then each place above it, each in its register's order"},"total":3383,"offset":0,"returned":50,"next_offset":50,"rows":[{"id":"e263b154e1f28990","parameter":"Zinc (dissolved)","value":"65 b,e","value_num":65,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-66-6","place":["US-MS"],"conditions":["receiving_water is freshwater","hardness 50 mg/l as CaCO3 (note b: the values in Table 2 are based on an in-stream hardness of 50 mg/l; other hardness takes the equations of EPA's Quality Criteria for Water)"],"cite":{"instrument":"us_ms_wqs","title":"Mississippi 11 Miss. Admin. Code Pt. 6, Ch. 2 Surface Water Quality Criteria for Intrastate, Interstate and Coastal Waters: Table 2 numeric criteria (freshwater and saltwater acute/chronic, human health), dissolved oxygen, pH, class mineral criteria and waterbody-specific criteria","issuer":"State of Mississippi, Commission on Environmental Quality (Department of Environmental Quality)","edition":"effective December 17, 2021, as US EPA posts it in effect for CWA purposes (cover March 18, 2022; EPA requested more information only on definition 27 and the Ephemeral Stream reference)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/ms-wqs.pdf","source_sha256":"272701c5d5a2f8b10cf9c40fc50f5eb52f07753965d4aad7d23d360d4da34264","fetched_at":"2026-10-10","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"11 Miss. Admin. Code Pt. 6, Ch. 2, Rule 2.2.G Table 2","page":19,"quote":null}},{"id":"8793662d9bc313c6","parameter":"Zinc (dissolved)","value":"65 b,e","value_num":65,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-66-6","place":["US-MS"],"conditions":["receiving_water is freshwater","hardness 50 mg/l as CaCO3 (note b: the values in Table 2 are based on an in-stream hardness of 50 mg/l; other hardness takes the equations of EPA's Quality Criteria for Water)"],"cite":{"instrument":"us_ms_wqs","title":"Mississippi 11 Miss. Admin. Code Pt. 6, Ch. 2 Surface Water Quality Criteria for Intrastate, Interstate and Coastal Waters: Table 2 numeric criteria (freshwater and saltwater acute/chronic, human health), dissolved oxygen, pH, class mineral criteria and waterbody-specific criteria","issuer":"State of Mississippi, Commission on Environmental Quality (Department of Environmental Quality)","edition":"effective December 17, 2021, as US EPA posts it in effect for CWA purposes (cover March 18, 2022; EPA requested more information only on definition 27 and the Ephemeral Stream reference)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/ms-wqs.pdf","source_sha256":"272701c5d5a2f8b10cf9c40fc50f5eb52f07753965d4aad7d23d360d4da34264","fetched_at":"2026-10-10","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"11 Miss. Admin. Code Pt. 6, Ch. 2, Rule 2.2.G Table 2","page":19,"quote":null}},{"id":"294e5545f46682fa","parameter":"Zinc (dissolved)","value":"90","value_num":90,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-66-6","place":["US-MS"],"conditions":["receiving_water is marine"],"cite":{"instrument":"us_ms_wqs","title":"Mississippi 11 Miss. Admin. Code Pt. 6, Ch. 2 Surface Water Quality Criteria for Intrastate, Interstate and Coastal Waters: Table 2 numeric criteria (freshwater and saltwater acute/chronic, human health), dissolved oxygen, pH, class mineral criteria and waterbody-specific criteria","issuer":"State of Mississippi, Commission on Environmental Quality (Department of Environmental Quality)","edition":"effective December 17, 2021, as US EPA posts it in effect for CWA purposes (cover March 18, 2022; EPA requested more information only on definition 27 and the Ephemeral Stream reference)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/ms-wqs.pdf","source_sha256":"272701c5d5a2f8b10cf9c40fc50f5eb52f07753965d4aad7d23d360d4da34264","fetched_at":"2026-10-10","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"11 Miss. Admin. Code Pt. 6, Ch. 2, Rule 2.2.G Table 2","page":19,"quote":null}},{"id":"04735ed04b125500","parameter":"Zinc (dissolved)","value":"81","value_num":81,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-66-6","place":["US-MS"],"conditions":["receiving_water is marine"],"cite":{"instrument":"us_ms_wqs","title":"Mississippi 11 Miss. Admin. Code Pt. 6, Ch. 2 Surface Water Quality Criteria for Intrastate, Interstate and Coastal Waters: Table 2 numeric criteria (freshwater and saltwater acute/chronic, human health), dissolved oxygen, pH, class mineral criteria and waterbody-specific criteria","issuer":"State of Mississippi, Commission on Environmental Quality (Department of Environmental Quality)","edition":"effective December 17, 2021, as US EPA posts it in effect for CWA purposes (cover March 18, 2022; EPA requested more information only on definition 27 and the Ephemeral Stream reference)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/ms-wqs.pdf","source_sha256":"272701c5d5a2f8b10cf9c40fc50f5eb52f07753965d4aad7d23d360d4da34264","fetched_at":"2026-10-10","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"11 Miss. Admin. Code Pt. 6, Ch. 2, Rule 2.2.G Table 2","page":19,"quote":null}},{"id":"fb2ee1d59633474a","parameter":"Zinc (dissolved)","value":"26,000","value_num":26000,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-66-6","place":["US-MS"],"conditions":["receiving_water is freshwater","all waters except those classified Public Water Supply or within 50 stream miles upstream of a drinking water intake, which take the water & organisms criteria (Rule 2.2.F.4(a))"],"cite":{"instrument":"us_ms_wqs","title":"Mississippi 11 Miss. Admin. Code Pt. 6, Ch. 2 Surface Water Quality Criteria for Intrastate, Interstate and Coastal Waters: Table 2 numeric criteria (freshwater and saltwater acute/chronic, human health), dissolved oxygen, pH, class mineral criteria and waterbody-specific criteria","issuer":"State of Mississippi, Commission on Environmental Quality (Department of Environmental Quality)","edition":"effective December 17, 2021, as US EPA posts it in effect for CWA purposes (cover March 18, 2022; EPA requested more information only on definition 27 and the Ephemeral Stream reference)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/ms-wqs.pdf","source_sha256":"272701c5d5a2f8b10cf9c40fc50f5eb52f07753965d4aad7d23d360d4da34264","fetched_at":"2026-10-10","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"11 Miss. Admin. Code Pt. 6, Ch. 2, Rule 2.2.G Table 2","page":19,"quote":null}},{"id":"63b90a46793c7a23","parameter":"Zinc (dissolved)","value":"26,000","value_num":26000,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-66-6","place":["US-MS"],"conditions":["receiving_water is marine","all waters except those classified Public Water Supply or within 50 stream miles upstream of a drinking water intake, which take the water & organisms criteria (Rule 2.2.F.4(a))"],"cite":{"instrument":"us_ms_wqs","title":"Mississippi 11 Miss. Admin. Code Pt. 6, Ch. 2 Surface Water Quality Criteria for Intrastate, Interstate and Coastal Waters: Table 2 numeric criteria (freshwater and saltwater acute/chronic, human health), dissolved oxygen, pH, class mineral criteria and waterbody-specific criteria","issuer":"State of Mississippi, Commission on Environmental Quality (Department of Environmental Quality)","edition":"effective December 17, 2021, as US EPA posts it in effect for CWA purposes (cover March 18, 2022; EPA requested more information only on definition 27 and the Ephemeral Stream reference)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/ms-wqs.pdf","source_sha256":"272701c5d5a2f8b10cf9c40fc50f5eb52f07753965d4aad7d23d360d4da34264","fetched_at":"2026-10-10","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"11 Miss. Admin. Code Pt. 6, Ch. 2, Rule 2.2.G Table 2","page":19,"quote":null}},{"id":"e9e4c666a5092815","parameter":"Zinc (dissolved)","value":"7,400","value_num":7400,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-66-6","place":["US-MS"],"conditions":["receiving_water is freshwater","waters classified Public Water Supply, or stream segments within 50 stream miles upstream of a drinking water intake (Rule 2.2.F.4(a))"],"cite":{"instrument":"us_ms_wqs","title":"Mississippi 11 Miss. Admin. Code Pt. 6, Ch. 2 Surface Water Quality Criteria for Intrastate, Interstate and Coastal Waters: Table 2 numeric criteria (freshwater and saltwater acute/chronic, human health), dissolved oxygen, pH, class mineral criteria and waterbody-specific criteria","issuer":"State of Mississippi, Commission on Environmental Quality (Department of Environmental Quality)","edition":"effective December 17, 2021, as US EPA posts it in effect for CWA purposes (cover March 18, 2022; EPA requested more information only on definition 27 and the Ephemeral Stream reference)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/ms-wqs.pdf","source_sha256":"272701c5d5a2f8b10cf9c40fc50f5eb52f07753965d4aad7d23d360d4da34264","fetched_at":"2026-10-10","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"11 Miss. Admin. Code Pt. 6, Ch. 2, Rule 2.2.G Table 2","page":19,"quote":null}},{"id":"bec06248dc6ab604","parameter":"Zinc","value":"2.61","value_num":2.61,"unit":"mg/L","statistic":"composite","direction":"max","kind":"limit","medium":"product","level":"national","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["(a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS."],"cite":{"instrument":"us_40cfr268_48","title":"40 CFR 268.48 — Universal treatment standards: Table UTS, wastewater and nonwastewater treatment standards for the hazardous constituents of land-disposal-restricted wastes","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"eCFR, 40 CFR 268.48 as of 2026-10-13 (title 40 up to date as of that day; source note: 59 FR 48103, Sept. 19, 1994, as last amended at 76 FR 34156, June 13, 2011)","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-13/title-40.xml?part=268&section=268.48","source_sha256":"70b2e58a6b1e228e2c204acc69b69fab0d5a0347e35d569959073c3dc3ee4adb","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 268.48, Table UTS, Inorganic Constituents, wastewater standard","page":null,"quote":"Zinc 5 7440-66-6 2.61 4.3 mg/l TCLP"}},{"id":"982979ccdcdac148","parameter":"Zinc","value":"4.3 mg/l TCLP","value_num":4.3,"unit":"mg/L TCLP","statistic":"instant","direction":"max","kind":"limit","medium":"leachate","level":"national","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["(a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS."],"cite":{"instrument":"us_40cfr268_48","title":"40 CFR 268.48 — Universal treatment standards: Table UTS, wastewater and nonwastewater treatment standards for the hazardous constituents of land-disposal-restricted wastes","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"eCFR, 40 CFR 268.48 as of 2026-10-13 (title 40 up to date as of that day; source note: 59 FR 48103, Sept. 19, 1994, as last amended at 76 FR 34156, June 13, 2011)","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-13/title-40.xml?part=268&section=268.48","source_sha256":"70b2e58a6b1e228e2c204acc69b69fab0d5a0347e35d569959073c3dc3ee4adb","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 268.48, Table UTS, Inorganic Constituents, nonwastewater standard","page":null,"quote":"Zinc 5 7440-66-6 2.61 4.3 mg/l TCLP"}},{"id":"7c6e90aba6823798","parameter":"Zn","value":"4.2","value_num":4.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Zn 4.2 2.6"}},{"id":"d89a5efb441081c6","parameter":"Zn","value":"2.6","value_num":2.6,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Zn 4.2 2.6"}},{"id":"55ee0122bcab26f3","parameter":"Zn","value":"164","value_num":164,"unit":"mg/sq m-Operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may be applied in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Zn 164 102"}},{"id":"a9be587fa686b4ac","parameter":"Zn","value":"102","value_num":102,"unit":"mg/sq m-Operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may be applied in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Zn 164 102"}},{"id":"7e3da0107714921c","parameter":"Zn","value":"4.2","value_num":4.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Zn 4.2 2.6"}},{"id":"b7224f12c2800dc8","parameter":"Zn","value":"2.6","value_num":2.6,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Zn 4.2 2.6"}},{"id":"dfc8eb8674ee1cd6","parameter":"Zn","value":"164","value_num":164,"unit":"mg/sq m-Operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Zn 164 102"}},{"id":"e78def7dd5987a01","parameter":"Zn","value":"102","value_num":102,"unit":"mg/sq m-Operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Zn 164 102"}},{"id":"3e3010b05bbf4001","parameter":"Zn","value":"4.2","value_num":4.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart D—Anodizing Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.44 (PSES)","page":null,"quote":"Zn 4.2 2.6"}},{"id":"00a3e1412e05b36c","parameter":"Zn","value":"2.6","value_num":2.6,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart D—Anodizing Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.44 (PSES)","page":null,"quote":"Zn 4.2 2.6"}},{"id":"4a6561c92dd7c189","parameter":"Zn","value":"164","value_num":164,"unit":"mg/sq m-operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart D—Anodizing Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.44 (PSES)","page":null,"quote":"Zn 164 102"}},{"id":"48537d32365bd3d5","parameter":"Zn","value":"102","value_num":102,"unit":"mg/sq m-operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart D—Anodizing Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.44 (PSES)","page":null,"quote":"Zn 164 102"}},{"id":"2dd736f1a8139689","parameter":"Zn","value":"4.2","value_num":4.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart E—Coatings Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart E—Coatings Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.54 (PSES)","page":null,"quote":"Zn 4.2 2.6"}},{"id":"6c9aabb9fa0dc2ce","parameter":"Zn","value":"2.6","value_num":2.6,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart E—Coatings Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart E—Coatings Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.54 (PSES)","page":null,"quote":"Zn 4.2 2.6"}},{"id":"96d2fe7eb89dbf21","parameter":"Zn","value":"164","value_num":164,"unit":"mg/sq m-operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart E—Coatings Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart E—Coatings Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.54 (PSES)","page":null,"quote":"Zn 164 102"}},{"id":"7257a8701af5c2b9","parameter":"Zn","value":"102","value_num":102,"unit":"mg/sq m-operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart E—Coatings Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart E—Coatings Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.54 (PSES)","page":null,"quote":"Zn 164 102"}},{"id":"e6868b2fdfafdc95","parameter":"Zn","value":"4.2","value_num":4.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart F—Chemical Etching and Milling Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal.) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart F—Chemicals Etching and Milling Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.64 (PSES)","page":null,"quote":"Zn 4.2 2.6"}},{"id":"57e02ee1102080a1","parameter":"Zn","value":"2.6","value_num":2.6,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart F—Chemical Etching and Milling Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal.) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart F—Chemicals Etching and Milling Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.64 (PSES)","page":null,"quote":"Zn 4.2 2.6"}},{"id":"d4f4bdc26e4ce779","parameter":"Zn","value":"164","value_num":164,"unit":"mg/sq m-operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart F—Chemical Etching and Milling Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart F—Chemical Etching and Milling Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.64 (PSES)","page":null,"quote":"Zn 164 102"}},{"id":"51d41c9bfd242310","parameter":"Zn","value":"102","value_num":102,"unit":"mg/sq m-operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart F—Chemical Etching and Milling Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart F—Chemical Etching and Milling Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.64 (PSES)","page":null,"quote":"Zn 164 102"}},{"id":"06441fc0bb33096b","parameter":"Zn","value":"4.2","value_num":4.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart G—Electroless Plating Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 l (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart G—Electroless Plating Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.74 (PSES)","page":null,"quote":"Zn 4.2 2.6"}},{"id":"a2cc63d4a1cd810e","parameter":"Zn","value":"2.6","value_num":2.6,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart G—Electroless Plating Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 l (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart G—Electroless Plating Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.74 (PSES)","page":null,"quote":"Zn 4.2 2.6"}},{"id":"8f6facb36bb719cb","parameter":"Zn","value":"164","value_num":164,"unit":"mg/sq m-operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart G—Electroless Plating Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart G—Electroless Plating Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.74 (PSES)","page":null,"quote":"Zn 164 102"}},{"id":"c1b4eb62484e6f9e","parameter":"Zn","value":"102","value_num":102,"unit":"mg/sq m-operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart G—Electroless Plating Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart G—Electroless Plating Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.74 (PSES)","page":null,"quote":"Zn 164 102"}},{"id":"f1404890dce20bb6","parameter":"Zn","value":"4.2","value_num":4.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart H—Printed Circuit Board Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart H—Printed Circuit Board Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.84 (PSES)","page":null,"quote":"Zn 4.2 2.6"}},{"id":"552fcd77756d68f0","parameter":"Zn","value":"2.6","value_num":2.6,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart H—Printed Circuit Board Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart H—Printed Circuit Board Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.84 (PSES)","page":null,"quote":"Zn 4.2 2.6"}},{"id":"689a2f1b7e109547","parameter":"Zn","value":"374","value_num":374,"unit":"mg/sq m-operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart H—Printed Circuit Board Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart H—Printed Circuit Board Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.84 (PSES)","page":null,"quote":"Zn 374 232"}},{"id":"efe170c2e41af680","parameter":"Zn","value":"232","value_num":232,"unit":"mg/sq m-operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart H—Printed Circuit Board Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart H—Printed Circuit Board Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.84 (PSES)","page":null,"quote":"Zn 374 232"}},{"id":"9d4e6a82d7d5e522","parameter":"Total Zinc","value":"2,610","value_num":2610,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment","existing sources (BAT)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 414.91 (BAT)","page":null,"quote":"Total Zinc 2 2,610 1,050"}},{"id":"a3da8e05a4af600c","parameter":"Total Zinc","value":"2,610","value_num":2610,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment","new sources (NSPS)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 414.91 (NSPS)","page":null,"quote":"Total Zinc 2 2,610 1,050"}},{"id":"c43455f279e8760e","parameter":"Total Zinc","value":"1,050","value_num":1050,"unit":"µg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment","existing sources (BAT)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 414.91 (BAT)","page":null,"quote":"Total Zinc 2 2,610 1,050"}},{"id":"c201f356df2d0fbb","parameter":"Total Zinc","value":"1,050","value_num":1050,"unit":"µg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment","new sources (NSPS)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 414.91 (NSPS)","page":null,"quote":"Total Zinc 2 2,610 1,050"}},{"id":"32ccec6665fda4f8","parameter":"Total Zinc","value":"2,610","value_num":2610,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment","existing sources (BAT)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 414.101 (BAT)","page":null,"quote":"Total Zinc 2 2,610 1,050"}},{"id":"5d8cbc368abea0c2","parameter":"Total Zinc","value":"2,610","value_num":2610,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment","new sources (NSPS)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 414.101 (NSPS)","page":null,"quote":"Total Zinc 2 2,610 1,050"}},{"id":"8c092c9d07b491c4","parameter":"Total Zinc","value":"1,050","value_num":1050,"unit":"µg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment","existing sources (BAT)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 414.101 (BAT)","page":null,"quote":"Total Zinc 2 2,610 1,050"}},{"id":"a9afac66c675f324","parameter":"Total Zinc","value":"1,050","value_num":1050,"unit":"µg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment","new sources (NSPS)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 414.101 (NSPS)","page":null,"quote":"Total Zinc 2 2,610 1,050"}},{"id":"5bc3bfa2c0306387","parameter":"Total Zinc","value":"2,610","value_num":2610,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is sewer","cites is 40 CFR 414","the discharge is of the Subpart K—Indirect Discharge Point Sources","new sources (PSNS)","(b) In the case of lead, zinc, and total cyanide the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for metals and times the flow from the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste streams are defined…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 414.111 (PSNS)","page":null,"quote":"Total Zinc 2 2,610 1,050"}},{"id":"d1365462c1d6cf9f","parameter":"Total Zinc","value":"1,050","value_num":1050,"unit":"µg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is sewer","cites is 40 CFR 414","the discharge is of the Subpart K—Indirect Discharge Point Sources","new sources (PSNS)","(b) In the case of lead, zinc, and total cyanide the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for metals and times the flow from the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste streams are defined…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 414.111 (PSNS)","page":null,"quote":"Total Zinc 2 2,610 1,050"}},{"id":"4bfb09280683f734","parameter":"Zinc","value":"5.0","value_num":5,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart B—Aluminum Sulfate Production Subcategory","existing sources (PSES)","table: Subpart B—Aluminum Sulfate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 415.24 (PSES)","page":null,"quote":"Zinc 5.0 2.5"}},{"id":"6810a47b1ac03f4e","parameter":"Zinc","value":"2.5","value_num":2.5,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart B—Aluminum Sulfate Production Subcategory","existing sources (PSES)","table: Subpart B—Aluminum Sulfate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 415.24 (PSES)","page":null,"quote":"Zinc 5.0 2.5"}},{"id":"76b7c56d6f55ade1","parameter":"Zinc (T)","value":"0.12","value_num":0.12,"unit":"Kg/kkg (or pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-66-6","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart H—Hydrofluoric Acid Production Subcategory","existing sources (BPT)","table: Subpart H—Hydrofluoric Acid"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 415.82 (BPT)","page":null,"quote":"Zinc (T) 0.12 0.036"}}],"next":[{"tool":"check_values","says":"Has your user measured this? check_values sets each of their results beside every row held here, with a verdict and the row's cite.","arguments":{"place":"US-MS"},"needs":{"rows":"Your user's measured results, as their table prints them: [{parameter: \"zinc\", value, unit}, ...], any other parameters too."},"post":"/api/v1/check"},{"tool":"read_certificate","says":"Has your user a laboratory certificate? read_certificate reads every row it prints, each with its page, and checks them against these limits.","arguments":{"place":"US-MS"},"needs":{"content_base64":"The laboratory's certificate (PDF) or its XLSX, XLS or CSV export, as base64; or file_url, a public https address of it."},"post":"/api/v1/certificate"}]}