{"query":{"parameter":"vanadium","place":"US-FL","medium":null,"statistic":null,"kind":null},"searched":{"places":["US-FL","US"],"parameter_keys":["cas:7440-62-2","cas:1314-62-1"],"names_matched":[["vanadium","cas:7440-62-2"],["vanadium oxide v2o5","cas:1314-62-1"],["vanadium pentoxide","cas:1314-62-1"],["vanadium pentoxide as vanadium","cas:1314-62-1"]],"match":"exact+contains","order":"The place's own instruments first, then each place above it, each in its register's order"},"total":47,"offset":0,"returned":47,"next_offset":null,"rows":[{"id":"ebcb9f04a35cf679","parameter":"Vanadium","value":"49","value_num":49,"unit":"µg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:7440-62-2","place":["US-FL"],"conditions":["groundwater (Table I, Groundwater Criteria column)","Note: If more than one contaminant is present at a site, CTLs are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Figure 10 of the February 2005 'Final Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.' However, GCTLs for primary and secondary standards shall not be modified."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","section":"Ch. 62-777 F.A.C. Table I, Groundwater and Surface Water Cleanup Target Levels, Groundwater Criteria (DEP spreadsheet, sheet TTable1, row 530)","page":null,"quote":"row 530: Vanadium | 49 |  |  | 490 | -Hair Loss  | 7440-62-2 |  | Minimum Criteria | NA | NA |  | Systemic Toxicant"}},{"id":"287ff4eb3aaf3318","parameter":"Vanadium","value":"490","value_num":490,"unit":"µg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:7440-62-2","place":["US-FL"],"conditions":["groundwater of low yield/poor quality (Table I, Groundwater of Low Yield/Poor Quality Criteria column)","Note: If more than one contaminant is present at a site, CTLs are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Figure 10 of the February 2005 'Final Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.' However, GCTLs for primary and secondary standards shall not be modified."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","section":"Ch. 62-777 F.A.C. Table I, Groundwater and Surface Water Cleanup Target Levels, Groundwater of Low Yield/Poor Quality Criteria (DEP spreadsheet, sheet TTable1, row 530)","page":null,"quote":"row 530: Vanadium | 49 |  |  | 490 | -Hair Loss  | 7440-62-2 |  | Minimum Criteria | NA | NA |  | Systemic Toxicant"}},{"id":"3d2a8197220f7f75","parameter":"Vanadium","value":"67","value_num":67,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7440-62-2","place":["US-FL"],"conditions":["residential direct exposure (Table II, Direct Exposure - Residential column)","** Direct exposure value based on acute toxicity considerations. This criterion is applicable in scenarios where children might be exposed to soils (e.g. residences, schools, playgrounds)","Note: If more than one contaminant is present at a site, the direct exposure values are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Appendix D 'Draft Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.', dated February 2005."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","section":"Ch. 62-777 F.A.C. Table II, Soil Cleanup Target Levels, Direct Exposure - Residential (DEP spreadsheet, sheet TTable2, row 469)","page":null,"quote":"row 469: Vanadium | -Hair Loss  | 7440-62-2 | 67** | 10000 | 980 | NA | NA | 9800 |  | (b)"}},{"id":"7a3b9aaccd5f89c7","parameter":"Vanadium","value":"10000","value_num":10000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7440-62-2","place":["US-FL"],"conditions":["industrial direct exposure (Table II, Direct Exposure - Industrial column)","Note: If more than one contaminant is present at a site, the direct exposure values are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Appendix D 'Draft Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.', dated February 2005."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","section":"Ch. 62-777 F.A.C. Table II, Soil Cleanup Target Levels, Direct Exposure - Industrial (DEP spreadsheet, sheet TTable2, row 469)","page":null,"quote":"row 469: Vanadium | -Hair Loss  | 7440-62-2 | 67** | 10000 | 980 | NA | NA | 9800 |  | (b)"}},{"id":"746c2188287d0abb","parameter":"Vanadium","value":"980","value_num":980,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7440-62-2","place":["US-FL"],"conditions":["leachability based on groundwater criteria (Table II, Leachability Based on Groundwater column)","Note: If more than one contaminant is present at a site, the direct exposure values are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Appendix D 'Draft Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.', dated February 2005."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","section":"Ch. 62-777 F.A.C. Table II, Soil Cleanup Target Levels, Leachability Based on Groundwater (DEP spreadsheet, sheet TTable2, row 469)","page":null,"quote":"row 469: Vanadium | -Hair Loss  | 7440-62-2 | 67** | 10000 | 980 | NA | NA | 9800 |  | (b)"}},{"id":"d83af568d8e1d0bd","parameter":"Vanadium","value":"9800","value_num":9800,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7440-62-2","place":["US-FL"],"conditions":["leachability based on groundwater of low yield/poor quality criteria (Table II, Leachability based on GW of Low Yield/Poor Quality column)","Note: If more than one contaminant is present at a site, the direct exposure values are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Appendix D 'Draft Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.', dated February 2005."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","section":"Ch. 62-777 F.A.C. Table II, Soil Cleanup Target Levels, Leachability based on GW of Low Yield/Poor Quality (DEP spreadsheet, sheet TTable2, row 469)","page":null,"quote":"row 469: Vanadium | -Hair Loss  | 7440-62-2 | 67** | 10000 | 980 | NA | NA | 9800 |  | (b)"}},{"id":"0281b7996c3557e1","parameter":"Vanadium pentoxide (as Vanadium)","value":"63","value_num":63,"unit":"µg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:1314-62-1","place":["US-FL"],"conditions":["groundwater (Table I, Groundwater Criteria column)","Note: If more than one contaminant is present at a site, CTLs are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Figure 10 of the February 2005 'Final Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.' However, GCTLs for primary and secondary standards shall not be modified."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","section":"Ch. 62-777 F.A.C. Table I, Groundwater and Surface Water Cleanup Target Levels, Groundwater Criteria (DEP spreadsheet, sheet TTable1, row 531)","page":null,"quote":"row 531: Vanadium pentoxide (as Vanadium) | 63 | 13 | 13 | 630 | -Hair Loss  | 1314-62-1 |  | Minimum Criteria | Toxicity Criteria | Toxicity Criteria |  | Systemic Toxicant"}},{"id":"a5b20bb0e32323a9","parameter":"Vanadium pentoxide (as Vanadium)","value":"13","value_num":13,"unit":"µg/L","direction":"max","kind":"threshold","medium":"surface_water","level":"regional","parameter_key":"cas:1314-62-1","place":["US-FL"],"conditions":["receiving_water is freshwater","freshwater surface water (Table I, Freshwater Surface Water Criteria column)","Note: If more than one contaminant is present at a site, CTLs are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Figure 10 of the February 2005 'Final Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.' However, GCTLs for primary and secondary standards shall not be modified."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","section":"Ch. 62-777 F.A.C. Table I, Groundwater and Surface Water Cleanup Target Levels, Freshwater Surface Water Criteria (DEP spreadsheet, sheet TTable1, row 531)","page":null,"quote":"row 531: Vanadium pentoxide (as Vanadium) | 63 | 13 | 13 | 630 | -Hair Loss  | 1314-62-1 |  | Minimum Criteria | Toxicity Criteria | Toxicity Criteria |  | Systemic Toxicant"}},{"id":"99f108f559970292","parameter":"Vanadium pentoxide (as Vanadium)","value":"13","value_num":13,"unit":"µg/L","direction":"max","kind":"threshold","medium":"surface_water","level":"regional","parameter_key":"cas:1314-62-1","place":["US-FL"],"conditions":["receiving_water is marine","marine surface water (Table I, Marine Surface Water Criteria column)","Note: If more than one contaminant is present at a site, CTLs are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Figure 10 of the February 2005 'Final Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.' However, GCTLs for primary and secondary standards shall not be modified."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","section":"Ch. 62-777 F.A.C. Table I, Groundwater and Surface Water Cleanup Target Levels, Marine Surface Water Criteria (DEP spreadsheet, sheet TTable1, row 531)","page":null,"quote":"row 531: Vanadium pentoxide (as Vanadium) | 63 | 13 | 13 | 630 | -Hair Loss  | 1314-62-1 |  | Minimum Criteria | Toxicity Criteria | Toxicity Criteria |  | Systemic Toxicant"}},{"id":"0ef9a9467879106e","parameter":"Vanadium pentoxide (as Vanadium)","value":"630","value_num":630,"unit":"µg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:1314-62-1","place":["US-FL"],"conditions":["groundwater of low yield/poor quality (Table I, Groundwater of Low Yield/Poor Quality Criteria column)","Note: If more than one contaminant is present at a site, CTLs are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Figure 10 of the February 2005 'Final Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.' However, GCTLs for primary and secondary standards shall not be modified."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","section":"Ch. 62-777 F.A.C. Table I, Groundwater and Surface Water Cleanup Target Levels, Groundwater of Low Yield/Poor Quality Criteria (DEP spreadsheet, sheet TTable1, row 531)","page":null,"quote":"row 531: Vanadium pentoxide (as Vanadium) | 63 | 13 | 13 | 630 | -Hair Loss  | 1314-62-1 |  | Minimum Criteria | Toxicity Criteria | Toxicity Criteria |  | Systemic Toxicant"}},{"id":"118d34cab79b4b94","parameter":"Vanadium","value":"4.3","value_num":4.3,"unit":"mg/L","statistic":"composite","direction":"max","kind":"limit","medium":"product","level":"national","parameter_key":"cas:7440-62-2","place":["US"],"conditions":["(a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS."],"cite":{"instrument":"us_40cfr268_48","title":"40 CFR 268.48 — Universal treatment standards: Table UTS, wastewater and nonwastewater treatment standards for the hazardous constituents of land-disposal-restricted wastes","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"eCFR, 40 CFR 268.48 as of 2026-10-13 (title 40 up to date as of that day; source note: 59 FR 48103, Sept. 19, 1994, as last amended at 76 FR 34156, June 13, 2011)","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-13/title-40.xml?part=268&section=268.48","source_sha256":"70b2e58a6b1e228e2c204acc69b69fab0d5a0347e35d569959073c3dc3ee4adb","fetched_at":"2026-10-15","section":"40 CFR 268.48, Table UTS, Inorganic Constituents, wastewater standard","page":null,"quote":"Vanadium 5 7440-62-2 4.3 1.6 mg/l TCLP"}},{"id":"69d827ccbfc8ab2b","parameter":"Vanadium","value":"1.6 mg/l TCLP","value_num":1.6,"unit":"mg/L TCLP","statistic":"instant","direction":"max","kind":"limit","medium":"leachate","level":"national","parameter_key":"cas:7440-62-2","place":["US"],"conditions":["(a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS."],"cite":{"instrument":"us_40cfr268_48","title":"40 CFR 268.48 — Universal treatment standards: Table UTS, wastewater and nonwastewater treatment standards for the hazardous constituents of land-disposal-restricted wastes","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"eCFR, 40 CFR 268.48 as of 2026-10-13 (title 40 up to date as of that day; source note: 59 FR 48103, Sept. 19, 1994, as last amended at 76 FR 34156, June 13, 2011)","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-13/title-40.xml?part=268&section=268.48","source_sha256":"70b2e58a6b1e228e2c204acc69b69fab0d5a0347e35d569959073c3dc3ee4adb","fetched_at":"2026-10-15","section":"40 CFR 268.48, Table UTS, Inorganic Constituents, nonwastewater standard","page":null,"quote":"Vanadium 5 7440-62-2 4.3 1.6 mg/l TCLP"}},{"id":"c1200c6fa0b621ea","parameter":"Vanadium","value":"0.218","value_num":0.218,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-62-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 437","the discharge is of the Subpart A—Metals Treatment and Recovery","existing sources (BPT)","table: BPT Limitations"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.11 (BPT)","page":null,"quote":"Vanadium 0.218 0.0662"}},{"id":"6be3dc80aad5f7a7","parameter":"Vanadium","value":"0.0662","value_num":0.0662,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-62-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 437","the discharge is of the Subpart A—Metals Treatment and Recovery","existing sources (BPT)","table: BPT Limitations"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.11 (BPT)","page":null,"quote":"Vanadium 0.218 0.0662"}},{"id":"24e045cd14b191a3","parameter":"Vanadium","value":"0.0628","value_num":0.0628,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-62-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 437","the discharge is of the Subpart A—Metals Treatment and Recovery","new sources (NSPS)","table: Performance Standards"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.14 (NSPS)","page":null,"quote":"Vanadium 0.0628 0.0518"}},{"id":"56d5b2d2ffef73bd","parameter":"Vanadium","value":"0.0518","value_num":0.0518,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-62-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 437","the discharge is of the Subpart A—Metals Treatment and Recovery","new sources (NSPS)","table: Performance Standards"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.14 (NSPS)","page":null,"quote":"Vanadium 0.0628 0.0518"}},{"id":"01f5a26bf2720237","parameter":"Vanadium","value":"0.218","value_num":0.218,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-62-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","existing sources (BPT)","(b) Combined waste receipts from subparts A, B, and C of this part. (1) As provided in § 437.42(a), any existing point source subject to this paragraph must achieve the following effluent limitations representing the application of BPT:","table: BPT Limitations"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.42 (BPT)","page":null,"quote":"Vanadium 0.218 0.0662"}},{"id":"7adf6510ba5843f6","parameter":"Vanadium","value":"0.0662","value_num":0.0662,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-62-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","existing sources (BPT)","(b) Combined waste receipts from subparts A, B, and C of this part. (1) As provided in § 437.42(a), any existing point source subject to this paragraph must achieve the following effluent limitations representing the application of BPT:","table: BPT Limitations"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.42 (BPT)","page":null,"quote":"Vanadium 0.218 0.0662"}},{"id":"b3c18860aacc36a4","parameter":"Vanadium","value":"0.218","value_num":0.218,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-62-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","existing sources (BPT)","(c) Combined waste receipts from subparts A and B of this part. (1) As provided in § 437.42(a), any existing point source subject to this paragraph must achieve the following effluent limitations representing the application of BPT:","table: BPT Limitations"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.42 (BPT)","page":null,"quote":"Vanadium 0.218 0.0662"}},{"id":"46cbd1d98151de68","parameter":"Vanadium","value":"0.0662","value_num":0.0662,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-62-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","existing sources (BPT)","(c) Combined waste receipts from subparts A and B of this part. (1) As provided in § 437.42(a), any existing point source subject to this paragraph must achieve the following effluent limitations representing the application of BPT:","table: BPT Limitations"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.42 (BPT)","page":null,"quote":"Vanadium 0.218 0.0662"}},{"id":"33380c9fb30687df","parameter":"Vanadium","value":"0.218","value_num":0.218,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-62-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","existing sources (BPT)","(d) Combined waste receipts from subparts A and C of this part. (1) As provided in § 437.42(a), any existing point source subject to this paragraph must achieve the following effluent limitations representing the application of BPT:","table: BPT Limitations"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.42 (BPT)","page":null,"quote":"Vanadium 0.218 0.0662"}},{"id":"9644a575e4e0aa38","parameter":"Vanadium","value":"0.0662","value_num":0.0662,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-62-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","existing sources (BPT)","(d) Combined waste receipts from subparts A and C of this part. (1) As provided in § 437.42(a), any existing point source subject to this paragraph must achieve the following effluent limitations representing the application of BPT:","table: BPT Limitations"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.42 (BPT)","page":null,"quote":"Vanadium 0.218 0.0662"}},{"id":"dcef0ca66bbb1384","parameter":"Vanadium","value":"0.0628","value_num":0.0628,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-62-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","new sources (NSPS)","(b) Combined waste receipts from subparts A, B and C of this part. (1) As provided in § 437.45(a), any new source subject to this paragraph must achieve the following performance standards:","table: Performance Standards"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.45 (NSPS)","page":null,"quote":"Vanadium 0.0628 0.0518"}},{"id":"23c21f71cf1ef890","parameter":"Vanadium","value":"0.0518","value_num":0.0518,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-62-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","new sources (NSPS)","(b) Combined waste receipts from subparts A, B and C of this part. (1) As provided in § 437.45(a), any new source subject to this paragraph must achieve the following performance standards:","table: Performance Standards"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.45 (NSPS)","page":null,"quote":"Vanadium 0.0628 0.0518"}},{"id":"8ff4af21a2b0969c","parameter":"Vanadium","value":"0.0628","value_num":0.0628,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-62-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","new sources (NSPS)","(c) Combined waste receipts from subparts A and B of this part. (1) As provided in § 437.45(a), any new source subject to this paragraph must achieve the following standards:","table: Performance Standards"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.45 (NSPS)","page":null,"quote":"Vanadium 0.0628 0.0518"}},{"id":"c201455d4dd743e8","parameter":"Vanadium","value":"0.0518","value_num":0.0518,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-62-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","new sources (NSPS)","(c) Combined waste receipts from subparts A and B of this part. (1) As provided in § 437.45(a), any new source subject to this paragraph must achieve the following standards:","table: Performance Standards"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.45 (NSPS)","page":null,"quote":"Vanadium 0.0628 0.0518"}},{"id":"8ae2c12544666714","parameter":"Vanadium","value":"0.0628","value_num":0.0628,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-62-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","new sources (NSPS)","(d) Combined waste receipts from subparts A and C of this part. (1) As provided in § 437.45(a), any new source subject to this paragraph must achieve the following performance standards:","table: Performance Standards"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.45 (NSPS)","page":null,"quote":"Vanadium 0.0628 0.0518"}},{"id":"31096730fd12897d","parameter":"Vanadium","value":"0.0518","value_num":0.0518,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-62-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","new sources (NSPS)","(d) Combined waste receipts from subparts A and C of this part. (1) As provided in § 437.45(a), any new source subject to this paragraph must achieve the following performance standards:","table: Performance Standards"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.45 (NSPS)","page":null,"quote":"Vanadium 0.0628 0.0518"}},{"id":"c5262315482c49e5","parameter":"Vanadium","value":"0.218","value_num":0.218,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-62-2","place":["US"],"conditions":["route is sewer","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","existing sources (PSES)","(b) Combined waste receipts from subparts A, B and C of this part. (1) As provided in § 437.46(a), and no later than [Insert date—three years after publication], any existing source subject to this paragraph must achieve the following pretreatment standards:","table: Pretreatment Standards (PSES)"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.46 (PSES)","page":null,"quote":"Vanadium 0.218 0.0662"}},{"id":"691f36f4f75db3f0","parameter":"Vanadium","value":"0.0662","value_num":0.0662,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-62-2","place":["US"],"conditions":["route is sewer","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","existing sources (PSES)","(b) Combined waste receipts from subparts A, B and C of this part. (1) As provided in § 437.46(a), and no later than [Insert date—three years after publication], any existing source subject to this paragraph must achieve the following pretreatment standards:","table: Pretreatment Standards (PSES)"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.46 (PSES)","page":null,"quote":"Vanadium 0.218 0.0662"}},{"id":"a70c6a9185953c65","parameter":"Vanadium","value":"0.218","value_num":0.218,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-62-2","place":["US"],"conditions":["route is sewer","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","existing sources (PSES)","(c) Combined waste receipts from subparts A and B of this part. (1) As provided in § 437.46(a), and no later than December 22, 2003, any existing source subject to this paragraph must achieve the following pretreatment standards:","table: Pretreatment Standards (PSES)"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.46 (PSES)","page":null,"quote":"Vanadium 0.218 0.0662"}},{"id":"58f3c7b32a273b7d","parameter":"Vanadium","value":"0.0662","value_num":0.0662,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-62-2","place":["US"],"conditions":["route is sewer","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","existing sources (PSES)","(c) Combined waste receipts from subparts A and B of this part. (1) As provided in § 437.46(a), and no later than December 22, 2003, any existing source subject to this paragraph must achieve the following pretreatment standards:","table: Pretreatment Standards (PSES)"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.46 (PSES)","page":null,"quote":"Vanadium 0.218 0.0662"}},{"id":"9560fbc15cb337da","parameter":"Vanadium","value":"0.218","value_num":0.218,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-62-2","place":["US"],"conditions":["route is sewer","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","existing sources (PSES)","(d) Combined waste receipts from subparts A and C of this part. (1) As provided in § 437.46(a), and no later than December 22, 2003, any existing source subject to this paragraph must achieve the following pretreatment standards:","table: Pretreatment Standards (PSES)"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.46 (PSES)","page":null,"quote":"Vanadium 0.218 0.0662"}},{"id":"df95891e10ca08e7","parameter":"Vanadium","value":"0.0662","value_num":0.0662,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-62-2","place":["US"],"conditions":["route is sewer","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","existing sources (PSES)","(d) Combined waste receipts from subparts A and C of this part. (1) As provided in § 437.46(a), and no later than December 22, 2003, any existing source subject to this paragraph must achieve the following pretreatment standards:","table: Pretreatment Standards (PSES)"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.46 (PSES)","page":null,"quote":"Vanadium 0.218 0.0662"}},{"id":"7484ba91f4b3be62","parameter":"Vanadium","value":"0.218","value_num":0.218,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-62-2","place":["US"],"conditions":["route is sewer","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","new sources (PSNS)","(b) Combined waste receipts from subparts A, B and C of this part. (1) As provided in § 437.47(a), any new source subject to this paragraph must achieve the following pretreatment standards:","table: Pretreatment Standards (PSNS)"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.47 (PSNS)","page":null,"quote":"Vanadium 0.218 0.0662"}},{"id":"f548cd55a29a6a3b","parameter":"Vanadium","value":"0.0662","value_num":0.0662,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-62-2","place":["US"],"conditions":["route is sewer","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","new sources (PSNS)","(b) Combined waste receipts from subparts A, B and C of this part. (1) As provided in § 437.47(a), any new source subject to this paragraph must achieve the following pretreatment standards:","table: Pretreatment Standards (PSNS)"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.47 (PSNS)","page":null,"quote":"Vanadium 0.218 0.0662"}},{"id":"68a4d54eb786b297","parameter":"Vanadium","value":"0.218","value_num":0.218,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-62-2","place":["US"],"conditions":["route is sewer","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","new sources (PSNS)","(c) Combined waste receipts from subparts A and B of this part. (1) As provided in § 437.47(a), any new source subject to this paragraph must achieve the following pretreatment standards:","table: Pretreatment Standards (PSNS)"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.47 (PSNS)","page":null,"quote":"Vanadium 0.218 0.0662"}},{"id":"b15eac84c2fa0c8f","parameter":"Vanadium","value":"0.0662","value_num":0.0662,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-62-2","place":["US"],"conditions":["route is sewer","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","new sources (PSNS)","(c) Combined waste receipts from subparts A and B of this part. (1) As provided in § 437.47(a), any new source subject to this paragraph must achieve the following pretreatment standards:","table: Pretreatment Standards (PSNS)"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.47 (PSNS)","page":null,"quote":"Vanadium 0.218 0.0662"}},{"id":"f261f1959b8ee25b","parameter":"Vanadium","value":"0.218","value_num":0.218,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-62-2","place":["US"],"conditions":["route is sewer","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","new sources (PSNS)","(d) Combined waste receipts from subparts A and C of this part. (1) As provided in § 437.47(a), any new source subject to this paragraph must achieve the following pretreatment standards:","table: Pretreatment Standards (PSNS)"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.47 (PSNS)","page":null,"quote":"Vanadium 0.218 0.0662"}},{"id":"428c390ffd32c322","parameter":"Vanadium","value":"0.0662","value_num":0.0662,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-62-2","place":["US"],"conditions":["route is sewer","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","new sources (PSNS)","(d) Combined waste receipts from subparts A and C of this part. (1) As provided in § 437.47(a), any new source subject to this paragraph must achieve the following pretreatment standards:","table: Pretreatment Standards (PSNS)"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.47 (PSNS)","page":null,"quote":"Vanadium 0.218 0.0662"}},{"id":"bfa160cfaa3da39f","parameter":"Vanadium and Compounds","value":"390","value_num":390,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"national","parameter_key":"cas:7440-62-2","place":["US"],"conditions":["Resident Soil (mg/kg)"],"cite":{"instrument":"us_rsl_soil","title":"US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Soil","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"November 2024","source_url":"https://semspub.epa.gov/src/document/HQ/405270","source_sha256":"0160dc81b4f55d738a354a74de92488f149946ebfa7c6a6c64592f45348043d7","fetched_at":"2026-09-19","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":null,"page":null,"quote":null,"table":"sols","column":"residentiel"}},{"id":"4403ded7b13f11bb","parameter":"Vanadium and Compounds","value":"5800","value_num":5800,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"national","parameter_key":"cas:7440-62-2","place":["US"],"conditions":["Industrial Soil (mg/kg)"],"cite":{"instrument":"us_rsl_soil","title":"US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Soil","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"November 2024","source_url":"https://semspub.epa.gov/src/document/HQ/405270","source_sha256":"0160dc81b4f55d738a354a74de92488f149946ebfa7c6a6c64592f45348043d7","fetched_at":"2026-09-19","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":null,"page":null,"quote":null,"table":"sols","column":"industriel"}},{"id":"29b18e3dc556f68d","parameter":"Vanadium and Compounds","value":"86","value_num":86,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"national","parameter_key":"cas:7440-62-2","place":["US"],"conditions":["Protection of Groundwater SSLs: Risk-based SSL (mg/kg); SSL values are based on DAF=1"],"cite":{"instrument":"us_rsl_soil","title":"US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Soil","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"November 2024","source_url":"https://semspub.epa.gov/src/document/HQ/405270","source_sha256":"0160dc81b4f55d738a354a74de92488f149946ebfa7c6a6c64592f45348043d7","fetched_at":"2026-09-19","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":null,"page":null,"quote":null,"table":"ssl","column":"risque"}},{"id":"a7502f2f676f3aad","parameter":"Vanadium and Compounds","value":"86","value_num":86,"unit":"µg/L","direction":"max","kind":"guideline","medium":"drinking_water","level":"national","parameter_key":"cas:7440-62-2","place":["US"],"conditions":["Tap Water (ug/L): Regional Screening Level (RSL) Summary Table (TR=1E-06, HQ=1) November 2024"],"cite":{"instrument":"us_rsl_tapwater","title":"US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Tap Water","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"November 2024","source_url":"https://semspub.epa.gov/src/document/HQ/405270","source_sha256":"0160dc81b4f55d738a354a74de92488f149946ebfa7c6a6c64592f45348043d7","fetched_at":"2026-09-19","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":null,"page":null,"quote":null,"table":"eau","column":"eau_robinet"}},{"id":"49d31ba08632b6c9","parameter":"Vanadium Pentoxide","value":"460","value_num":460,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"national","parameter_key":"cas:1314-62-1","place":["US"],"conditions":["Resident Soil (mg/kg)"],"cite":{"instrument":"us_rsl_soil","title":"US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Soil","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"November 2024","source_url":"https://semspub.epa.gov/src/document/HQ/405270","source_sha256":"0160dc81b4f55d738a354a74de92488f149946ebfa7c6a6c64592f45348043d7","fetched_at":"2026-09-19","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":null,"page":null,"quote":null,"table":"sols","column":"residentiel"}},{"id":"f3936ee66645b04f","parameter":"Vanadium Pentoxide","value":"2000","value_num":2000,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"national","parameter_key":"cas:1314-62-1","place":["US"],"conditions":["Industrial Soil (mg/kg)"],"cite":{"instrument":"us_rsl_soil","title":"US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Soil","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"November 2024","source_url":"https://semspub.epa.gov/src/document/HQ/405270","source_sha256":"0160dc81b4f55d738a354a74de92488f149946ebfa7c6a6c64592f45348043d7","fetched_at":"2026-09-19","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":null,"page":null,"quote":null,"table":"sols","column":"industriel"}},{"id":"b060ead622b34653","parameter":"Vanadium Pentoxide","value":"150","value_num":150,"unit":"µg/L","direction":"max","kind":"guideline","medium":"drinking_water","level":"national","parameter_key":"cas:1314-62-1","place":["US"],"conditions":["Tap Water (ug/L): Regional Screening Level (RSL) Summary Table (TR=1E-06, HQ=1) November 2024"],"cite":{"instrument":"us_rsl_tapwater","title":"US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Tap Water","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"November 2024","source_url":"https://semspub.epa.gov/src/document/HQ/405270","source_sha256":"0160dc81b4f55d738a354a74de92488f149946ebfa7c6a6c64592f45348043d7","fetched_at":"2026-09-19","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":null,"page":null,"quote":null,"table":"eau","column":"eau_robinet"}}],"next":[{"tool":"check_values","says":"Has your user measured this? check_values sets each of their results beside every row held here, with a verdict and the row's cite.","arguments":{"place":"US-FL"},"needs":{"rows":"Your user's measured results, as their table prints them: [{parameter: \"vanadium\", value, unit}, ...], any other parameters too."},"post":"/api/v1/check"},{"tool":"read_certificate","says":"Has your user a laboratory certificate? read_certificate reads every row it prints, each with its page, and checks them against these limits.","arguments":{"place":"US-FL"},"needs":{"content_base64":"The laboratory's certificate (PDF) or its XLSX, XLS or CSV export, as base64; or file_url, a public https address of it."},"post":"/api/v1/certificate"}]}