{"query":{"parameter":"tin","place":"US-TX","medium":null,"statistic":null,"kind":null},"searched":{"places":["US-TX","US"],"parameter_keys":["cas:7440-31-5","name:tin"],"names_matched":[["tin","cas:7440-31-5"],["tin","name:tin"]],"match":"exact","order":"The place's own instruments first, then each place above it, each in its register's order"},"total":150,"offset":0,"returned":50,"next_offset":50,"rows":[{"id":"a7d25bb2ece67897","parameter":"Tin","value":"3.5E+04","value_num":35000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7440-31-5","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 1, Residential Soil, TotSoilComb, 0.5 acre source area","page":21,"quote":null}},{"id":"8b0d2087ddb76a5e","parameter":"Tin","value":"3.7E+04","value_num":37000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7440-31-5","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 1, Residential Soil, GWSoilIng, 0.5 acre source area","page":21,"quote":null}},{"id":"1152edf3c0364922","parameter":"Tin","value":"1.0E+06","value_num":1000000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7440-31-5","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 1, Residential Soil, GWSoilClass 3, 0.5 acre source area","page":21,"quote":null}},{"id":"f43263e19f18ec81","parameter":"Tin","value":"3.5E+04","value_num":35000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7440-31-5","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 1, Residential Soil, TotSoilComb, 30 acre source area","page":21,"quote":null}},{"id":"b93ad9ce9680dfb4","parameter":"Tin","value":"1.8E+04","value_num":18000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7440-31-5","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 1, Residential Soil, GWSoilIng, 30 acre source area","page":21,"quote":null}},{"id":"900a0704f89be509","parameter":"Tin","value":"1.0E+06","value_num":1000000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7440-31-5","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 1, Residential Soil, GWSoilClass 3, 30 acre source area","page":21,"quote":null}},{"id":"411d1f26647aaefd","parameter":"Tin","value":"4.1E+05","value_num":410000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7440-31-5","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 2, Commercial/Industrial Soil, TotSoilComb, 0.5 acre source area","page":36,"quote":null}},{"id":"2d8328af8516a42f","parameter":"Tin","value":"1.1E+05","value_num":110000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7440-31-5","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 2, Commercial/Industrial Soil, GWSoilIng, 0.5 acre source area","page":36,"quote":null}},{"id":"f82095d142275a1a","parameter":"Tin","value":"1.0E+06","value_num":1000000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7440-31-5","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 2, Commercial/Industrial Soil, GWSoilClass 3, 0.5 acre source area","page":36,"quote":null}},{"id":"429421dd09d6cf8e","parameter":"Tin","value":"4.1E+05","value_num":410000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7440-31-5","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 2, Commercial/Industrial Soil, TotSoilComb, 30 acre source area","page":36,"quote":null}},{"id":"66bf60c9adc4e2e8","parameter":"Tin","value":"5.5E+04","value_num":55000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7440-31-5","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 2, Commercial/Industrial Soil, GWSoilIng, 30 acre source area","page":36,"quote":null}},{"id":"d6eb523243b48e53","parameter":"Tin","value":"1.0E+06","value_num":1000000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7440-31-5","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 2, Commercial/Industrial Soil, GWSoilClass 3, 30 acre source area","page":36,"quote":null}},{"id":"8d14de33524b0ac6","parameter":"Tin","value":"1.5E+01","value_num":15,"unit":"mg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:7440-31-5","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 3, Groundwater, GWGWIng, Residential","page":49,"quote":null}},{"id":"00bddfeb142212c6","parameter":"Tin","value":"1.5E+03","value_num":1500,"unit":"mg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:7440-31-5","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 3, Groundwater, GWGWClass3, Residential","page":49,"quote":null}},{"id":"8fcdd019c9a5fe86","parameter":"Tin","value":"4.4E+01","value_num":44,"unit":"mg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:7440-31-5","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 3, Groundwater, GWGWIng, Commercial/Industrial","page":49,"quote":null}},{"id":"7961ba6793df1dda","parameter":"Tin","value":"4.4E+03","value_num":4400,"unit":"mg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:7440-31-5","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 3, Groundwater, GWGWClass3, Commercial/Industrial","page":49,"quote":null}},{"id":"ace3a57d72719948","parameter":"Tin","value":"47000","value_num":47000,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"national","parameter_key":"cas:7440-31-5","place":["US"],"conditions":["Resident Soil (mg/kg)"],"cite":{"instrument":"us_rsl_soil","title":"US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Soil","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"November 2024","source_url":"https://semspub.epa.gov/src/document/HQ/405270","source_sha256":"0160dc81b4f55d738a354a74de92488f149946ebfa7c6a6c64592f45348043d7","fetched_at":"2026-09-19","source_status":{"checked":"2026-10-15","status":"not verified"},"section":null,"page":null,"quote":null,"table":"sols","column":"residentiel"}},{"id":"abafadc3e5418f6d","parameter":"Tin","value":"700000","value_num":700000,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"national","parameter_key":"cas:7440-31-5","place":["US"],"conditions":["Industrial Soil (mg/kg)"],"cite":{"instrument":"us_rsl_soil","title":"US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Soil","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"November 2024","source_url":"https://semspub.epa.gov/src/document/HQ/405270","source_sha256":"0160dc81b4f55d738a354a74de92488f149946ebfa7c6a6c64592f45348043d7","fetched_at":"2026-09-19","source_status":{"checked":"2026-10-15","status":"not verified"},"section":null,"page":null,"quote":null,"table":"sols","column":"industriel"}},{"id":"d2734494696b0fb2","parameter":"Tin","value":"3000","value_num":3000,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"national","parameter_key":"cas:7440-31-5","place":["US"],"conditions":["Protection of Groundwater SSLs: Risk-based SSL (mg/kg); SSL values are based on DAF=1"],"cite":{"instrument":"us_rsl_soil","title":"US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Soil","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"November 2024","source_url":"https://semspub.epa.gov/src/document/HQ/405270","source_sha256":"0160dc81b4f55d738a354a74de92488f149946ebfa7c6a6c64592f45348043d7","fetched_at":"2026-09-19","source_status":{"checked":"2026-10-15","status":"not verified"},"section":null,"page":null,"quote":null,"table":"ssl","column":"risque"}},{"id":"53a1ff6566be472e","parameter":"Tin","value":"12000","value_num":12000,"unit":"µg/L","direction":"max","kind":"guideline","medium":"drinking_water","level":"national","parameter_key":"cas:7440-31-5","place":["US"],"conditions":["Tap Water (ug/L): Regional Screening Level (RSL) Summary Table (TR=1E-06, HQ=1) November 2024"],"cite":{"instrument":"us_rsl_tapwater","title":"US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Tap Water","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"November 2024","source_url":"https://semspub.epa.gov/src/document/HQ/405270","source_sha256":"0160dc81b4f55d738a354a74de92488f149946ebfa7c6a6c64592f45348043d7","fetched_at":"2026-09-19","source_status":{"checked":"2026-10-15","status":"not verified"},"section":null,"page":null,"quote":null,"table":"eau","column":"eau_robinet"}},{"id":"955294e815f9e3b6","parameter":"Tin","value":"3.495","value_num":3.495,"unit":"mg/kg (pounds per million pounds) of crude tapped tin metal produced","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:tin","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart AA—Secondary Tin Subcategory","existing sources (BPT)","(a) Tin smelter SO 2 scrubber.","table: BPT Limitations for the Secondary Tin Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.292 (BPT)","page":null,"quote":"Tin 3.495 2.024"}},{"id":"516a93a7fb1ff42c","parameter":"Tin","value":"2.024","value_num":2.024,"unit":"mg/kg (pounds per million pounds) of crude tapped tin metal produced","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:tin","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart AA—Secondary Tin Subcategory","existing sources (BPT)","(a) Tin smelter SO 2 scrubber.","table: BPT Limitations for the Secondary Tin Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.292 (BPT)","page":null,"quote":"Tin 3.495 2.024"}},{"id":"795370c2948a80b3","parameter":"Tin","value":"0.013","value_num":0.013,"unit":"mg/kg (pounds per million pounds) of dealuminized scrap produced","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:tin","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart AA—Secondary Tin Subcategory","existing sources (BPT)","(b) Dealuminizing rinse.","table: BPT Limitations for the Secondary Tin Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.292 (BPT)","page":null,"quote":"Tin 0.013 0.008"}},{"id":"566e85ca0a292588","parameter":"Tin","value":"0.008","value_num":0.008,"unit":"mg/kg (pounds per million pounds) of dealuminized scrap produced","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:tin","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart AA—Secondary Tin Subcategory","existing sources (BPT)","(b) Dealuminizing rinse.","table: BPT Limitations for the Secondary Tin Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.292 (BPT)","page":null,"quote":"Tin 0.013 0.008"}},{"id":"bc7731adaeb5b7ae","parameter":"Tin","value":"1.918","value_num":1.918,"unit":"mg/kg (pounds per million pounds) of neutralized, dewatered tin mud produced","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:tin","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart AA—Secondary Tin Subcategory","existing sources (BPT)","(c) Tin mud acid neutralization filtrate.","table: BPT Limitations for the Secondary Tin Subcategory","column: Minimum for any 1 day"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.292 (BPT)","page":null,"quote":"Tin 1.918 1.110"}},{"id":"2188a6f0c4b7b6a7","parameter":"Tin","value":"1.110","value_num":1.11,"unit":"mg/kg (pounds per million pounds) of neutralized, dewatered tin mud produced","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:tin","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart AA—Secondary Tin Subcategory","existing sources (BPT)","(c) Tin mud acid neutralization filtrate.","table: BPT Limitations for the Secondary Tin Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.292 (BPT)","page":null,"quote":"Tin 1.918 1.110"}},{"id":"5aca9fed9dba6ac0","parameter":"Tin","value":"4.542","value_num":4.542,"unit":"mg/kg (pounds per million pounds) of tin hydroxide washed","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:tin","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart AA—Secondary Tin Subcategory","existing sources (BPT)","(d) Tin hydroxide wash.","table: BPT Limitations for the Secondary Tin Subcategory","column: Minimum for any 1 day"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.292 (BPT)","page":null,"quote":"Tin 4.542 2.630"}},{"id":"bfd3f1f2661f80a1","parameter":"Tin","value":"2.630","value_num":2.63,"unit":"mg/kg (pounds per million pounds) of tin hydroxide washed","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:tin","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart AA—Secondary Tin Subcategory","existing sources (BPT)","(d) Tin hydroxide wash.","table: BPT Limitations for the Secondary Tin Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.292 (BPT)","page":null,"quote":"Tin 4.542 2.630"}},{"id":"99b4db043f02b754","parameter":"Tin","value":"6.384","value_num":6.384,"unit":"mg/kg (pounds per million pounds) of cathode tin produced","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:tin","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart AA—Secondary Tin Subcategory","existing sources (BPT)","(e) Spent electrowinning solution from new scrap.","table: BPT Limitations for the Secondary Tin Subcategory","column: Minimum for any 1 day"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.292 (BPT)","page":null,"quote":"Tin 6.384 3.696"}},{"id":"f6afb37f4a0d668f","parameter":"Tin","value":"3.696","value_num":3.696,"unit":"mg/kg (pounds per million pounds) of cathode tin produced","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:tin","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart AA—Secondary Tin Subcategory","existing sources (BPT)","(e) Spent electrowinning solution from new scrap.","table: BPT Limitations for the Secondary Tin Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.292 (BPT)","page":null,"quote":"Tin 6.384 3.696"}},{"id":"621ea7777af323fe","parameter":"Tin","value":"0.045","value_num":0.045,"unit":"mg/kg (pounds per million pounds) of MSW scrap used as raw material","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:tin","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart AA—Secondary Tin Subcategory","existing sources (BPT)","(f) Spent electrowinning solution from municipal solid waste.","table: BPT Limitations for the Secondary Tin Subcategory","column: Minimum for any 1 day"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.292 (BPT)","page":null,"quote":"Tin 0.045 0.026"}},{"id":"019d8f8cabb649eb","parameter":"Tin","value":"0.026","value_num":0.026,"unit":"mg/kg (pounds per million pounds) of MSW scrap used as raw material","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:tin","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart AA—Secondary Tin Subcategory","existing sources (BPT)","(f) Spent electrowinning solution from municipal solid waste.","table: BPT Limitations for the Secondary Tin Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.292 (BPT)","page":null,"quote":"Tin 0.045 0.026"}},{"id":"71674fefde615535","parameter":"Tin","value":"21.140","value_num":21.14,"unit":"mg/kg (pounds per million pounds) of tin metal recovered from scrap","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:tin","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart AA—Secondary Tin Subcategory","existing sources (BPT)","(g) Tin hydroxide supernatant from scrap.","table: BPT Limitations for the Secondary Tin Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.292 (BPT)","page":null,"quote":"Tin 21.140 12.240"}},{"id":"95211b324109851f","parameter":"Tin","value":"12.240","value_num":12.24,"unit":"mg/kg (pounds per million pounds) of tin metal recovered from scrap","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:tin","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart AA—Secondary Tin Subcategory","existing sources (BPT)","(g) Tin hydroxide supernatant from scrap.","table: BPT Limitations for the Secondary Tin Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.292 (BPT)","page":null,"quote":"Tin 21.140 12.240"}},{"id":"7b453dfdf0b77679","parameter":"Tin","value":"43.70","value_num":43.7,"unit":"mg/kg (pounds per million pounds) of tin metal recovered from plating solutions and sludges","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:tin","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart AA—Secondary Tin Subcategory","existing sources (BPT)","(h) Tin hydroxide supernatant from plating solutions and sludges.","table: BPT Limitations for the Secondary Tin Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.292 (BPT)","page":null,"quote":"Tin 43.70 25.30"}},{"id":"0c3b7158066bc673","parameter":"Tin","value":"25.30","value_num":25.3,"unit":"mg/kg (pounds per million pounds) of tin metal recovered from plating solutions and sludges","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:tin","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart AA—Secondary Tin Subcategory","existing sources (BPT)","(h) Tin hydroxide supernatant from plating solutions and sludges.","table: BPT Limitations for the Secondary Tin Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.292 (BPT)","page":null,"quote":"Tin 43.70 25.30"}},{"id":"4756a69af300b213","parameter":"Tin","value":"9.517","value_num":9.517,"unit":"mg/kg (pounds per million pounds) of tin metal produced","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:tin","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart AA—Secondary Tin Subcategory","existing sources (BPT)","(i) Tin hydroxide filtrate.","table: BPT Limitations for the Secondary Tin Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.292 (BPT)","page":null,"quote":"Tin 9.517 5.510"}},{"id":"bf39d7ac65d831a4","parameter":"Tin","value":"5.510","value_num":5.51,"unit":"mg/kg (pounds per million pounds) of tin metal produced","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:tin","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart AA—Secondary Tin Subcategory","existing sources (BPT)","(i) Tin hydroxide filtrate.","table: BPT Limitations for the Secondary Tin Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.292 (BPT)","page":null,"quote":"Tin 9.517 5.510"}},{"id":"ed8bc7263ec97545","parameter":"Tin","value":"3.495","value_num":3.495,"unit":"mg/kg (pounds per million pounds) of crude tapped tin produced","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:tin","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart AA—Secondary Tin Subcategory","existing sources (BAT)","(a) Tin smelter SO 2 scrubber.","table: BAT Limitations for the Secondary Tin Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.293 (BAT)","page":null,"quote":"Tin 3.495 2.024"}},{"id":"323e0f13443cd215","parameter":"Tin","value":"2.024","value_num":2.024,"unit":"mg/kg (pounds per million pounds) of crude tapped tin produced","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:tin","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart AA—Secondary Tin Subcategory","existing sources (BAT)","(a) Tin smelter SO 2 scrubber.","table: BAT Limitations for the Secondary Tin Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.293 (BAT)","page":null,"quote":"Tin 3.495 2.024"}},{"id":"721ffd3d366823ea","parameter":"Tin","value":"0.013","value_num":0.013,"unit":"mg/kg (pounds per million pounds) of dealuminized scrap produced","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:tin","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart AA—Secondary Tin Subcategory","existing sources (BAT)","(b) Dealuminizing rinse.","table: BAT Limitations for the Secondary Tin Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.293 (BAT)","page":null,"quote":"Tin 0.013 0.008"}},{"id":"b1a11d0daf065e30","parameter":"Tin","value":"0.008","value_num":0.008,"unit":"mg/kg (pounds per million pounds) of dealuminized scrap produced","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:tin","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart AA—Secondary Tin Subcategory","existing sources (BAT)","(b) Dealuminizing rinse.","table: BAT Limitations for the Secondary Tin Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.293 (BAT)","page":null,"quote":"Tin 0.013 0.008"}},{"id":"0a5126d20505e809","parameter":"Tin","value":"1.918","value_num":1.918,"unit":"mg/kg (pounds per million pounds) of neutralized dewatered tin mud produced","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:tin","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart AA—Secondary Tin Subcategory","existing sources (BAT)","(c) Tin mud acid neutralization filtrate.","table: BAT Limitations for the Secondary Tin Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.293 (BAT)","page":null,"quote":"Tin 1.918 1.110"}},{"id":"95294dd330cd9892","parameter":"Tin","value":"1.110","value_num":1.11,"unit":"mg/kg (pounds per million pounds) of neutralized dewatered tin mud produced","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:tin","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart AA—Secondary Tin Subcategory","existing sources (BAT)","(c) Tin mud acid neutralization filtrate.","table: BAT Limitations for the Secondary Tin Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.293 (BAT)","page":null,"quote":"Tin 1.918 1.110"}},{"id":"b74a24855bf049d8","parameter":"Tin","value":"4.542","value_num":4.542,"unit":"mg/kg (pounds per million pounds) of tin hydroxide washed","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:tin","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart AA—Secondary Tin Subcategory","existing sources (BAT)","(d) Tin hydroxide wash.","table: BAT Limitations for the Secondary Tin Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.293 (BAT)","page":null,"quote":"Tin 4.542 2.630"}},{"id":"adf59799e768ac45","parameter":"Tin","value":"2.630","value_num":2.63,"unit":"mg/kg (pounds per million pounds) of tin hydroxide washed","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:tin","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart AA—Secondary Tin Subcategory","existing sources (BAT)","(d) Tin hydroxide wash.","table: BAT Limitations for the Secondary Tin Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.293 (BAT)","page":null,"quote":"Tin 4.542 2.630"}},{"id":"13375b1a6cc9106f","parameter":"Tin","value":"6.384","value_num":6.384,"unit":"mg/kg (pounds per million pounds) of cathode tin produced","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:tin","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart AA—Secondary Tin Subcategory","existing sources (BAT)","(e) Spent electrowinning solution from new scrap.","table: BAT Limitations for the Secondary Tin Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.293 (BAT)","page":null,"quote":"Tin 6.384 3.696"}},{"id":"86f2247ea231e5d9","parameter":"Tin","value":"3.696","value_num":3.696,"unit":"mg/kg (pounds per million pounds) of cathode tin produced","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:tin","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart AA—Secondary Tin Subcategory","existing sources (BAT)","(e) Spent electrowinning solution from new scrap.","table: BAT Limitations for the Secondary Tin Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.293 (BAT)","page":null,"quote":"Tin 6.384 3.696"}},{"id":"6612f4fc4f97d533","parameter":"Tin","value":"0.045","value_num":0.045,"unit":"mg/kg (pounds per million pounds) of MSW scrap used as raw material","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:tin","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart AA—Secondary Tin Subcategory","existing sources (BAT)","(f) Spent electrowinning solution from municipal solid waste.","table: BAT Limitations for the Secondary Tin Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.293 (BAT)","page":null,"quote":"Tin 0.045 0.026"}},{"id":"4cbae9f2804cf27c","parameter":"Tin","value":"0.026","value_num":0.026,"unit":"mg/kg (pounds per million pounds) of MSW scrap used as raw material","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:tin","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart AA—Secondary Tin Subcategory","existing sources (BAT)","(f) Spent electrowinning solution from municipal solid waste.","table: BAT Limitations for the Secondary Tin Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.293 (BAT)","page":null,"quote":"Tin 0.045 0.026"}}],"next":[{"tool":"check_values","says":"Has your user measured this? check_values sets each of their results beside every row held here, with a verdict and the row's cite.","arguments":{"place":"US-TX"},"needs":{"rows":"Your user's measured results, as their table prints them: [{parameter: \"tin\", value, unit}, ...], any other parameters too."},"post":"/api/v1/check"},{"tool":"read_certificate","says":"Has your user a laboratory certificate? read_certificate reads every row it prints, each with its page, and checks them against these limits.","arguments":{"place":"US-TX"},"needs":{"content_base64":"The laboratory's certificate (PDF) or its XLSX, XLS or CSV export, as base64; or file_url, a public https address of it."},"post":"/api/v1/certificate"}]}