{"query":{"parameter":"tetrachloro ethylene","place":"US-NH","medium":null,"statistic":null,"kind":null},"searched":{"places":["US-NH","US"],"parameter_keys":["cas:127-18-4","name:tetrachloro-ethylene","name:tetrachloroethene ou perchloroethylene","name:tetrachloroethene and trichloroethene","name:tetracloroetilene"],"names_matched":[["tetrachloro ethylene","cas:127-18-4"],["tetrachloro ethylene","name:tetrachloro-ethylene"],["tetrachloroethene ou perchloroethylene","name:tetrachloroethene ou perchloroethylene","perchloroethylene"],["tetrachloroethene and trichloroethene","name:tetrachloroethene and trichloroethene","tetrachloroethene"],["tetracloroetilene","name:tetracloroetilene","tetracloroetilene"],["tetracloroetilene pce","name:tetracloroetilene","tetracloroetilene"]],"match":"exact+contains","order":"The place's own instruments first, then each place above it, each in its register's order"},"total":59,"offset":0,"returned":50,"next_offset":50,"rows":[{"id":"a211dc09a79f0244","parameter":"Tetrachloroethylene","value":"5,280","value_num":5280,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:127-18-4","place":["US-NH"],"conditions":["receiving_water is freshwater"],"cite":{"instrument":"us_nh_wqs","title":"New Hampshire Env-Wq 1700 Surface Water Quality Regulations: Table 1703-1 water quality criteria for toxic substances (fresh and marine acute/chronic aquatic life; human health), and class dissolved oxygen and pH","issuer":"State of New Hampshire, Department of Environmental Services","edition":"Env-Wq 1700 effective December 13, 2022 as US EPA posts it in effect for CWA purposes (cover page April 6, 2023), with the human health columns from the February 13, 2015 rule EPA also posts (its 2022 revisions still under EPA review); the state re-adopted Env-Wq 1700 effective 2-26-25 (#14203), not what EPA posts","source_url":"https://www.epa.gov/system/files/documents/2023-04/wqs-nh-chapter1700-2022.pdf","source_sha256":"6749401e33fb746b1a37e31e356dbaa9ccff1f936edc9cd3948b1bae47c796f2","fetched_at":"2026-10-10","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"Env-Wq 1703.21 Table 1703-1","page":22,"quote":null}},{"id":"a9a03a3b0467da57","parameter":"Tetrachloroethylene","value":"840","value_num":840,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:127-18-4","place":["US-NH"],"conditions":["receiving_water is freshwater"],"cite":{"instrument":"us_nh_wqs","title":"New Hampshire Env-Wq 1700 Surface Water Quality Regulations: Table 1703-1 water quality criteria for toxic substances (fresh and marine acute/chronic aquatic life; human health), and class dissolved oxygen and pH","issuer":"State of New Hampshire, Department of Environmental Services","edition":"Env-Wq 1700 effective December 13, 2022 as US EPA posts it in effect for CWA purposes (cover page April 6, 2023), with the human health columns from the February 13, 2015 rule EPA also posts (its 2022 revisions still under EPA review); the state re-adopted Env-Wq 1700 effective 2-26-25 (#14203), not what EPA posts","source_url":"https://www.epa.gov/system/files/documents/2023-04/wqs-nh-chapter1700-2022.pdf","source_sha256":"6749401e33fb746b1a37e31e356dbaa9ccff1f936edc9cd3948b1bae47c796f2","fetched_at":"2026-10-10","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"Env-Wq 1703.21 Table 1703-1","page":22,"quote":null}},{"id":"24bd5e290c7fa68a","parameter":"Tetrachloroethylene","value":"10,200","value_num":10200,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:127-18-4","place":["US-NH"],"conditions":["receiving_water is marine"],"cite":{"instrument":"us_nh_wqs","title":"New Hampshire Env-Wq 1700 Surface Water Quality Regulations: Table 1703-1 water quality criteria for toxic substances (fresh and marine acute/chronic aquatic life; human health), and class dissolved oxygen and pH","issuer":"State of New Hampshire, Department of Environmental Services","edition":"Env-Wq 1700 effective December 13, 2022 as US EPA posts it in effect for CWA purposes (cover page April 6, 2023), with the human health columns from the February 13, 2015 rule EPA also posts (its 2022 revisions still under EPA review); the state re-adopted Env-Wq 1700 effective 2-26-25 (#14203), not what EPA posts","source_url":"https://www.epa.gov/system/files/documents/2023-04/wqs-nh-chapter1700-2022.pdf","source_sha256":"6749401e33fb746b1a37e31e356dbaa9ccff1f936edc9cd3948b1bae47c796f2","fetched_at":"2026-10-10","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"Env-Wq 1703.21 Table 1703-1","page":22,"quote":null}},{"id":"72264f64b01a4347","parameter":"Tetrachloroethylene","value":"450","value_num":450,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:127-18-4","place":["US-NH"],"conditions":["receiving_water is marine"],"cite":{"instrument":"us_nh_wqs","title":"New Hampshire Env-Wq 1700 Surface Water Quality Regulations: Table 1703-1 water quality criteria for toxic substances (fresh and marine acute/chronic aquatic life; human health), and class dissolved oxygen and pH","issuer":"State of New Hampshire, Department of Environmental Services","edition":"Env-Wq 1700 effective December 13, 2022 as US EPA posts it in effect for CWA purposes (cover page April 6, 2023), with the human health columns from the February 13, 2015 rule EPA also posts (its 2022 revisions still under EPA review); the state re-adopted Env-Wq 1700 effective 2-26-25 (#14203), not what EPA posts","source_url":"https://www.epa.gov/system/files/documents/2023-04/wqs-nh-chapter1700-2022.pdf","source_sha256":"6749401e33fb746b1a37e31e356dbaa9ccff1f936edc9cd3948b1bae47c796f2","fetched_at":"2026-10-10","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"Env-Wq 1703.21 Table 1703-1","page":22,"quote":null}},{"id":"e12b8f23d195ad47","parameter":"Tetrachloroethylene","value":"0.80 ugc","value_num":0.8,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:127-18-4","place":["US-NH"],"conditions":["receiving_water is freshwater","water and fish ingestion (Table 1703.1's 'Water & Fish Ingestion' column; held for fresh water, tidal water not being drunk)"],"cite":{"instrument":"us_nh_wqs","title":"New Hampshire Env-Wq 1700 Surface Water Quality Regulations: Table 1703-1 water quality criteria for toxic substances (fresh and marine acute/chronic aquatic life; human health), and class dissolved oxygen and pH","issuer":"State of New Hampshire, Department of Environmental Services","edition":"Env-Wq 1700 effective December 13, 2022 as US EPA posts it in effect for CWA purposes (cover page April 6, 2023), with the human health columns from the February 13, 2015 rule EPA also posts (its 2022 revisions still under EPA review); the state re-adopted Env-Wq 1700 effective 2-26-25 (#14203), not what EPA posts","source_url":"https://www.epa.gov/system/files/documents/2023-04/wqs-nh-chapter1700-2022.pdf","source_sha256":"6749401e33fb746b1a37e31e356dbaa9ccff1f936edc9cd3948b1bae47c796f2","fetched_at":"2026-10-10","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"Env-Wq 1703.21 Table 1703.1 (2015)","page":24,"quote":null}},{"id":"76c5e4186b28f951","parameter":"Tetrachloroethylene","value":"8.85 ugc","value_num":8.85,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:127-18-4","place":["US-NH"],"conditions":["receiving_water is freshwater"],"cite":{"instrument":"us_nh_wqs","title":"New Hampshire Env-Wq 1700 Surface Water Quality Regulations: Table 1703-1 water quality criteria for toxic substances (fresh and marine acute/chronic aquatic life; human health), and class dissolved oxygen and pH","issuer":"State of New Hampshire, Department of Environmental Services","edition":"Env-Wq 1700 effective December 13, 2022 as US EPA posts it in effect for CWA purposes (cover page April 6, 2023), with the human health columns from the February 13, 2015 rule EPA also posts (its 2022 revisions still under EPA review); the state re-adopted Env-Wq 1700 effective 2-26-25 (#14203), not what EPA posts","source_url":"https://www.epa.gov/system/files/documents/2023-04/wqs-nh-chapter1700-2022.pdf","source_sha256":"6749401e33fb746b1a37e31e356dbaa9ccff1f936edc9cd3948b1bae47c796f2","fetched_at":"2026-10-10","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"Env-Wq 1703.21 Table 1703.1 (2015)","page":24,"quote":null}},{"id":"1ff4ad70fdac00a3","parameter":"Tetrachloroethylene","value":"8.85 ugc","value_num":8.85,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:127-18-4","place":["US-NH"],"conditions":["receiving_water is marine"],"cite":{"instrument":"us_nh_wqs","title":"New Hampshire Env-Wq 1700 Surface Water Quality Regulations: Table 1703-1 water quality criteria for toxic substances (fresh and marine acute/chronic aquatic life; human health), and class dissolved oxygen and pH","issuer":"State of New Hampshire, Department of Environmental Services","edition":"Env-Wq 1700 effective December 13, 2022 as US EPA posts it in effect for CWA purposes (cover page April 6, 2023), with the human health columns from the February 13, 2015 rule EPA also posts (its 2022 revisions still under EPA review); the state re-adopted Env-Wq 1700 effective 2-26-25 (#14203), not what EPA posts","source_url":"https://www.epa.gov/system/files/documents/2023-04/wqs-nh-chapter1700-2022.pdf","source_sha256":"6749401e33fb746b1a37e31e356dbaa9ccff1f936edc9cd3948b1bae47c796f2","fetched_at":"2026-10-10","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"Env-Wq 1703.21 Table 1703.1 (2015)","page":24,"quote":null}},{"id":"1b1e75a15b29ecc2","parameter":"Tetrachloroethylene","value":"0.7","value_num":0.7,"unit":"mg/L","direction":"max","kind":"threshold","medium":"leachate","level":"national","parameter_key":"cas:127-18-4","place":["US"],"conditions":["(a) A solid waste (except manufactured gas plant waste) exhibits the characteristic of toxicity if, using the Toxicity Characteristic Leaching Procedure, test Method 1311 in “Test Methods for Evaluating Solid Waste, Physical/Chemical Methods,” EPA Publication SW-846, as incorporated by reference in § 260.11 of this chapter, the extract from a representative sample of the waste contains any of the contaminants listed in table 1 at the concentration equal to or greater than the respective value given in that table. Where the waste contains less than 0.5 percent filterable solids, the waste itself, after filtering using the methodology outlined in Method 1311, is considered to be the extract for the purpose of this section."],"cite":{"instrument":"us_40cfr261_24","title":"40 CFR 261.24 — Toxicity characteristic: Table 1, maximum concentration of contaminants for the toxicity characteristic (TCLP regulatory levels)","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"eCFR, 40 CFR 261.24 as of 2026-10-13 (title 40 up to date as of that day)","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-13/title-40.xml?part=261&section=261.24","source_sha256":"3a1ec9b0d3051c70e471e359275657b0fa6d98e80927d2217e82b2dbbca60961","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 261.24, Table 1","page":null,"quote":"D039 Tetrachloroethylene 127-18-4 0.7"}},{"id":"222eb5119c5bfb21","parameter":"Tetrachloroethylene","value":"0.056","value_num":0.056,"unit":"mg/L","statistic":"composite","direction":"max","kind":"limit","medium":"product","level":"national","parameter_key":"cas:127-18-4","place":["US"],"conditions":["(a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS."],"cite":{"instrument":"us_40cfr268_48","title":"40 CFR 268.48 — Universal treatment standards: Table UTS, wastewater and nonwastewater treatment standards for the hazardous constituents of land-disposal-restricted wastes","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"eCFR, 40 CFR 268.48 as of 2026-10-13 (title 40 up to date as of that day; source note: 59 FR 48103, Sept. 19, 1994, as last amended at 76 FR 34156, June 13, 2011)","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-13/title-40.xml?part=268&section=268.48","source_sha256":"70b2e58a6b1e228e2c204acc69b69fab0d5a0347e35d569959073c3dc3ee4adb","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 268.48, Table UTS, Organic Constituents, wastewater standard","page":null,"quote":"Tetrachloroethylene 127-18-4 0.056 6.0"}},{"id":"1dc8e70635176ee4","parameter":"Tetrachloroethylene","value":"6.0","value_num":6,"unit":"mg/kg","statistic":"instant","direction":"max","kind":"limit","medium":"product","level":"national","parameter_key":"cas:127-18-4","place":["US"],"conditions":["(a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS."],"cite":{"instrument":"us_40cfr268_48","title":"40 CFR 268.48 — Universal treatment standards: Table UTS, wastewater and nonwastewater treatment standards for the hazardous constituents of land-disposal-restricted wastes","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"eCFR, 40 CFR 268.48 as of 2026-10-13 (title 40 up to date as of that day; source note: 59 FR 48103, Sept. 19, 1994, as last amended at 76 FR 34156, June 13, 2011)","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-13/title-40.xml?part=268&section=268.48","source_sha256":"70b2e58a6b1e228e2c204acc69b69fab0d5a0347e35d569959073c3dc3ee4adb","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 268.48, Table UTS, Organic Constituents, nonwastewater standard","page":null,"quote":"Tetrachloroethylene 127-18-4 0.056 6.0"}},{"id":"cdddbe096186b8b6","parameter":"Tetrachloroethylene","value":"56","value_num":56,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:127-18-4","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment","existing sources (BAT)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 414.91 (BAT)","page":null,"quote":"Tetrachloroethylene 56 22"}},{"id":"65ad54f085e5ccca","parameter":"Tetrachloroethylene","value":"56","value_num":56,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:127-18-4","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment","new sources (NSPS)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 414.91 (NSPS)","page":null,"quote":"Tetrachloroethylene 56 22"}},{"id":"85a0e69de54f7867","parameter":"Tetrachloroethylene","value":"22","value_num":22,"unit":"µg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:127-18-4","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment","existing sources (BAT)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 414.91 (BAT)","page":null,"quote":"Tetrachloroethylene 56 22"}},{"id":"2a2147637544f80d","parameter":"Tetrachloroethylene","value":"22","value_num":22,"unit":"µg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:127-18-4","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment","new sources (NSPS)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 414.91 (NSPS)","page":null,"quote":"Tetrachloroethylene 56 22"}},{"id":"7c2307cf17bb8423","parameter":"Tetrachloroethylene","value":"164","value_num":164,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:127-18-4","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment","existing sources (BAT)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 414.101 (BAT)","page":null,"quote":"Tetrachloroethylene 164 52"}},{"id":"3e4cf50762c6aa31","parameter":"Tetrachloroethylene","value":"164","value_num":164,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:127-18-4","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment","new sources (NSPS)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 414.101 (NSPS)","page":null,"quote":"Tetrachloroethylene 164 52"}},{"id":"a8042aa109c71b8c","parameter":"Tetrachloroethylene","value":"52","value_num":52,"unit":"µg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:127-18-4","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment","existing sources (BAT)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 414.101 (BAT)","page":null,"quote":"Tetrachloroethylene 164 52"}},{"id":"159e43dc102a94ec","parameter":"Tetrachloroethylene","value":"52","value_num":52,"unit":"µg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:127-18-4","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment","new sources (NSPS)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 414.101 (NSPS)","page":null,"quote":"Tetrachloroethylene 164 52"}},{"id":"0d30284e773549d0","parameter":"Tetrachloroethylene","value":"164","value_num":164,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:127-18-4","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is sewer","cites is 40 CFR 414","the discharge is of the Subpart K—Indirect Discharge Point Sources","new sources (PSNS)","(b) In the case of lead, zinc, and total cyanide the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for metals and times the flow from the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste streams are defined…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 414.111 (PSNS)","page":null,"quote":"Tetrachloroethylene 164 52"}},{"id":"b628a8ce41071214","parameter":"Tetrachloroethylene","value":"52","value_num":52,"unit":"µg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:127-18-4","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is sewer","cites is 40 CFR 414","the discharge is of the Subpart K—Indirect Discharge Point Sources","new sources (PSNS)","(b) In the case of lead, zinc, and total cyanide the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for metals and times the flow from the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste streams are defined…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 414.111 (PSNS)","page":null,"quote":"Tetrachloroethylene 164 52"}},{"id":"3c05524e5bbc9566","parameter":"Tetrachloroethylene","value":"0.0000031","value_num":0.0000031,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:127-18-4","place":["US"],"conditions":["route is direct","cites is 40 CFR 420","the discharge is of the Subpart J—Cold Forming Subcategory","existing sources (BPT)","(a) Cold rolling mills —(1) Recirculation—single stand.","table: Subpart J"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 420.102 (BPT)","page":null,"quote":"Tetrachloroethylene 0.0000031"}},{"id":"daf71272215fcde3","parameter":"Tetrachloroethylene","value":"0.0000156","value_num":0.0000156,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:127-18-4","place":["US"],"conditions":["route is direct","cites is 40 CFR 420","the discharge is of the Subpart J—Cold Forming Subcategory","existing sources (BPT)","(2) Recirculation—multiple stands.","table: Subpart J"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 420.102 (BPT)","page":null,"quote":"Tetrachloroethylene 0.0000156"}},{"id":"5e4161119670ec9f","parameter":"Tetrachloroethylene","value":"0.000188","value_num":0.000188,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:127-18-4","place":["US"],"conditions":["route is direct","cites is 40 CFR 420","the discharge is of the Subpart J—Cold Forming Subcategory","existing sources (BPT)","(3) Combination.","table: Subpart J"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 420.102 (BPT)","page":null,"quote":"Tetrachloroethylene 0.000188"}},{"id":"e59aef31d7416af6","parameter":"Tetrachloroethylene","value":"0.0000563","value_num":0.0000563,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:127-18-4","place":["US"],"conditions":["route is direct","cites is 40 CFR 420","the discharge is of the Subpart J—Cold Forming Subcategory","existing sources (BPT)","(4) Direct application—single stand.","table: Subpart J"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 420.102 (BPT)","page":null,"quote":"Tetrachloroethylene 0.0000563"}},{"id":"561788ae842c3b3b","parameter":"Tetrachloroethylene","value":"0.000250","value_num":0.00025,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:127-18-4","place":["US"],"conditions":["route is direct","cites is 40 CFR 420","the discharge is of the Subpart J—Cold Forming Subcategory","existing sources (BPT)","(5) Direct application—multiple stands.","table: Subpart J"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 420.102 (BPT)","page":null,"quote":"Tetrachloroethylene 0.000250"}},{"id":"4e19603be90f0828","parameter":"Tetrachloroethylene","value":"0.0000031","value_num":0.0000031,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:127-18-4","place":["US"],"conditions":["route is direct","cites is 40 CFR 420","the discharge is of the Subpart J—Cold Forming Subcategory","existing sources (BPT)","(2) Using oil solutions.","table: Subpart J"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 420.102 (BPT)","page":null,"quote":"Tetrachloroethylene 0.0000031"}},{"id":"3f9b30f7824bcc88","parameter":"Tetrachloroethylene","value":"0.0000031","value_num":0.0000031,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:127-18-4","place":["US"],"conditions":["route is direct","cites is 40 CFR 420","the discharge is of the Subpart J—Cold Forming Subcategory","existing sources (BAT)","(a) Cold rolling mills —(1) Recirculation—single stand.","table: Subpart J"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 420.103 (BAT)","page":null,"quote":"Tetrachloroethylene 0.0000031"}},{"id":"d72a01739fe89548","parameter":"Tetrachloroethylene","value":"0.0000156","value_num":0.0000156,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:127-18-4","place":["US"],"conditions":["route is direct","cites is 40 CFR 420","the discharge is of the Subpart J—Cold Forming Subcategory","existing sources (BAT)","(2) Recirculation—multiple stands.","table: Subpart J"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 420.103 (BAT)","page":null,"quote":"Tetrachloroethylene 0.0000156"}},{"id":"2a7093b90c445a7a","parameter":"Tetrachloroethylene","value":"0.000188","value_num":0.000188,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:127-18-4","place":["US"],"conditions":["route is direct","cites is 40 CFR 420","the discharge is of the Subpart J—Cold Forming Subcategory","existing sources (BAT)","(3) Combination.","table: Subpart J"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 420.103 (BAT)","page":null,"quote":"Tetrachloroethylene 0.000188"}},{"id":"e750a39d7f138534","parameter":"Tetrachloroethylene","value":"0.0000563","value_num":0.0000563,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:127-18-4","place":["US"],"conditions":["route is direct","cites is 40 CFR 420","the discharge is of the Subpart J—Cold Forming Subcategory","existing sources (BAT)","(4) Direct application—single stand.","table: Subpart J"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 420.103 (BAT)","page":null,"quote":"Tetrachloroethylene 0.0000563"}},{"id":"b5f7419fa4c7cf36","parameter":"Tetrachloroethylene","value":"0.000250","value_num":0.00025,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:127-18-4","place":["US"],"conditions":["route is direct","cites is 40 CFR 420","the discharge is of the Subpart J—Cold Forming Subcategory","existing sources (BAT)","(5) Direct application—multiple stands.","table: Subpart J"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 420.103 (BAT)","page":null,"quote":"Tetrachloroethylene 0.000250"}},{"id":"d0e22d7eb6cc7fd6","parameter":"Tetrachloroethylene","value":"0.0000031","value_num":0.0000031,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:127-18-4","place":["US"],"conditions":["route is direct","cites is 40 CFR 420","the discharge is of the Subpart J—Cold Forming Subcategory","existing sources (BAT)","(2) Using oil solutions.","table: Subpart J"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 420.103 (BAT)","page":null,"quote":"Tetrachloroethylene 0.0000031"}},{"id":"9940b174fe6d0500","parameter":"Tetrachloroethylene","value":"0.0000031","value_num":0.0000031,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:127-18-4","place":["US"],"conditions":["route is direct","cites is 40 CFR 420","the discharge is of the Subpart J—Cold Forming Subcategory","new sources (NSPS)","(a) Cold rolling mills —(1) Recirculation—single stand.","table: Subpart J"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 420.104 (NSPS)","page":null,"quote":"Tetrachloroethylene 0.0000031"}},{"id":"e3490185a3770b68","parameter":"Tetrachloroethylene","value":"0.0000063","value_num":0.0000063,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:127-18-4","place":["US"],"conditions":["route is direct","cites is 40 CFR 420","the discharge is of the Subpart J—Cold Forming Subcategory","new sources (NSPS)","(2) Recirculation—multiple stands.","table: Subpart J"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 420.104 (NSPS)","page":null,"quote":"Tetrachloroethylene 0.0000063"}},{"id":"e7ad407f6c96feba","parameter":"Tetrachloroethylene","value":"0.0000813","value_num":0.0000813,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:127-18-4","place":["US"],"conditions":["route is direct","cites is 40 CFR 420","the discharge is of the Subpart J—Cold Forming Subcategory","new sources (NSPS)","(3) Combination.","table: Subpart J"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 420.104 (NSPS)","page":null,"quote":"Tetrachloroethylene 0.0000813"}},{"id":"6cc6859cdb6e3177","parameter":"Tetrachloroethylene","value":"0.0000031","value_num":0.0000031,"unit":"kg/kkg (pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:127-18-4","place":["US"],"conditions":["route is direct","cites is 40 CFR 420","the discharge is of the Subpart J—Cold Forming Subcategory","new sources (NSPS)","(2) Using oil solutions.","table: Subpart J"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 420.104 (NSPS)","page":null,"quote":"Tetrachloroethylene 0.0000031"}},{"id":"979ec8c9fd41faea","parameter":"Tetrachloroethylene","value":"0.0000031","value_num":0.0000031,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:127-18-4","place":["US"],"conditions":["route is sewer","cites is 40 CFR 420","the discharge is of the Subpart J—Cold Forming Subcategory","existing sources (PSES)","(a) Cold rolling —(1) Recirculation—single stand.","table: Subpart J"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 420.105 (PSES)","page":null,"quote":"Tetrachloroethylene 0.0000031"}},{"id":"7eee72b025bf9b95","parameter":"Tetrachloroethylene","value":"0.0000156","value_num":0.0000156,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:127-18-4","place":["US"],"conditions":["route is sewer","cites is 40 CFR 420","the discharge is of the Subpart J—Cold Forming Subcategory","existing sources (PSES)","(2) Recirculation—multiple stands.","table: Subpart J"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 420.105 (PSES)","page":null,"quote":"Tetrachloroethylene 0.0000156"}},{"id":"d97789d2d23b4cfc","parameter":"Tetrachloroethylene","value":"0.000188","value_num":0.000188,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:127-18-4","place":["US"],"conditions":["route is sewer","cites is 40 CFR 420","the discharge is of the Subpart J—Cold Forming Subcategory","existing sources (PSES)","(3) Combination.","table: Subpart J"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 420.105 (PSES)","page":null,"quote":"Tetrachloroethylene 0.000188"}},{"id":"b8479be249a60e32","parameter":"Tetrachloroethylene","value":"0.0000563","value_num":0.0000563,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:127-18-4","place":["US"],"conditions":["route is sewer","cites is 40 CFR 420","the discharge is of the Subpart J—Cold Forming Subcategory","existing sources (PSES)","(4) Direct application—single stand.","table: Subpart J"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 420.105 (PSES)","page":null,"quote":"Tetrachloroethylene 0.0000563"}},{"id":"4456472ca2a3ac18","parameter":"Tetrachloroethylene","value":"0.000250","value_num":0.00025,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:127-18-4","place":["US"],"conditions":["route is sewer","cites is 40 CFR 420","the discharge is of the Subpart J—Cold Forming Subcategory","existing sources (PSES)","(5) Direct application—multiple stands.","table: Subpart J"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 420.105 (PSES)","page":null,"quote":"Tetrachloroethylene 0.000250"}},{"id":"ef750fc019748bbf","parameter":"Tetrachloroethylene","value":"0.0000031","value_num":0.0000031,"unit":"kg/kkg (pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:127-18-4","place":["US"],"conditions":["route is sewer","cites is 40 CFR 420","the discharge is of the Subpart J—Cold Forming Subcategory","existing sources (PSES)","(2) Using oil solutions.","table: Subpart J"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 420.105 (PSES)","page":null,"quote":"Tetrachloroethylene 0.0000031"}},{"id":"9b36da7ea06cbd81","parameter":"Tetrachloroethylene","value":"0.0000031","value_num":0.0000031,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:127-18-4","place":["US"],"conditions":["route is sewer","cites is 40 CFR 420","the discharge is of the Subpart J—Cold Forming Subcategory","new sources (PSNS)","(a) Cold rolling —(1) Recirculation—single stand.","table: Subpart J"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 420.106 (PSNS)","page":null,"quote":"Tetrachloroethylene 0.0000031"}},{"id":"4eadb947d79a77c6","parameter":"Tetrachloroethylene","value":"0.0000063","value_num":0.0000063,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:127-18-4","place":["US"],"conditions":["route is sewer","cites is 40 CFR 420","the discharge is of the Subpart J—Cold Forming Subcategory","new sources (PSNS)","(2) Recirculation—multiple stands.","table: Subpart J"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 420.106 (PSNS)","page":null,"quote":"Tetrachloroethylene 0.0000063"}},{"id":"52dac28829211c63","parameter":"Tetrachloroethylene","value":"0.0000813","value_num":0.0000813,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:127-18-4","place":["US"],"conditions":["route is sewer","cites is 40 CFR 420","the discharge is of the Subpart J—Cold Forming Subcategory","new sources (PSNS)","(3) Combination.","table: Subpart J"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 420.106 (PSNS)","page":null,"quote":"Tetrachloroethylene 0.0000813"}},{"id":"d4e29ccf4f54d517","parameter":"Tetrachloroethylene","value":"0.0000156","value_num":0.0000156,"unit":"Kg/kkg pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:127-18-4","place":["US"],"conditions":["route is sewer","cites is 40 CFR 420","the discharge is of the Subpart J—Cold Forming Subcategory","new sources (PSNS)","(4) Direct application—single stand.","table: Subpart J"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 420.106 (PSNS)","page":null,"quote":"Tetrachloroethylene 0.0000156"}},{"id":"7701f9f73913373f","parameter":"Tetrachloroethylene","value":"0.000182","value_num":0.000182,"unit":"Kg/kkg pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:127-18-4","place":["US"],"conditions":["route is sewer","cites is 40 CFR 420","the discharge is of the Subpart J—Cold Forming Subcategory","new sources (PSNS)","(5) Direct application—multiple stands.","table: Subpart J"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 420.106 (PSNS)","page":null,"quote":"Tetrachloroethylene 0.000182"}},{"id":"6da2a445ed340366","parameter":"Tetrachloroethylene","value":"0.0000031","value_num":0.0000031,"unit":"kg/kkg (pound per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:127-18-4","place":["US"],"conditions":["route is sewer","cites is 40 CFR 420","the discharge is of the Subpart J—Cold Forming Subcategory","new sources (PSNS)","(2) Using oil solutions.","table: Subpart J"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 420.106 (PSNS)","page":null,"quote":"Tetrachloroethylene 0.0000031"}},{"id":"2c14ff843654b4c0","parameter":"Tetrachloroethylene","value":"0.005","value_num":0.005,"unit":"mg/l","direction":"max","kind":"limit","medium":"drinking_water","level":"national","parameter_key":"cas:127-18-4","place":["US"],"conditions":["40 CFR 141.2: Maximum contaminant level means the maximum permissible level of a contaminant in water which is delivered to any user of a public water system."],"cite":{"instrument":"us_npdwr","title":"40 CFR Part 141 — National Primary Drinking Water Regulations (eCFR, as of 2026-08-01)","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=141","source_sha256":"bd534eb2d8af38e141e1cd6236134a638298fbf14791b30279eeb47d815d7767","fetched_at":"2026-08-29","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"141.61","page":null,"quote":null,"column":"mcl"}},{"id":"386ab3311ea25f25","parameter":"Tetrachloroethylene","value":"10","value_num":10,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"national","parameter_key":"cas:127-18-4","place":["US"],"conditions":["EPA's recommendation under Clean Water Act § 304(a): 'State and Tribal governments may use these criteria or use them as guidance in developing their own' — it binds a water once the state adopts it for the water's designated use","receiving_water is freshwater","consumption of water + organism: a water designated a drinking-water source and for fish and shellfish (a designated use the state assigns)"],"cite":{"instrument":"us_nrwqc_human_health","title":"EPA National Recommended Water Quality Criteria — Human Health Criteria Table (water + organism, organism only)","issuer":"U.S. Environmental Protection Agency","edition":"EPA web table (fetched 2026-10-09); each criterion carries its publication year","source_url":"https://www.epa.gov/wqc/national-recommended-water-quality-criteria-human-health-criteria-table","source_sha256":"a0229d5a613672b46a000c5b9925dd3a23c3e05914bb020b7f739c69cecbb5fe","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"National Recommended Water Quality Criteria — Human Health Criteria Table","page":null,"quote":"Tetrachloroethylene (P) 127184 10 29 2015"}}],"next":[{"tool":"check_values","says":"Has your user measured this? check_values sets each of their results beside every row held here, with a verdict and the row's cite.","arguments":{"place":"US-NH"},"needs":{"rows":"Your user's measured results, as their table prints them: [{parameter: \"tetrachloro ethylene\", value, unit}, ...], any other parameters too."},"post":"/api/v1/check"},{"tool":"read_certificate","says":"Has your user a laboratory certificate? read_certificate reads every row it prints, each with its page, and checks them against these limits.","arguments":{"place":"US-NH"},"needs":{"content_base64":"The laboratory's certificate (PDF) or its XLSX, XLS or CSV export, as base64; or file_url, a public https address of it."},"post":"/api/v1/certificate"}]}