{"query":{"parameter":"selenium","place":"US-TX","medium":null,"statistic":null,"kind":null},"searched":{"places":["US-TX","US"],"parameter_keys":["cas:7782-49-2","cas:7783-00-8","name:selenium-75","name:selenium, dissolved","name:selenium, fish egg or ovary tissue","name:selenium, fish muscle tissue","name:selenium, fish whole body tissue","cas:7446-34-6","name:selenium, total","name:selenium - total alert concentration","name:selenium - total guideline","name:selenium v","name:total selenium","name:total selenium [freshwater – for flowing (lotic) waters]","name:total selenium [freshwater – for still/standing (lentic) waters]"],"names_matched":[["selenium","cas:7782-49-2"],["selenious acid as selenium","cas:7783-00-8"],["selenium 75","name:selenium-75"],["selenium dissolved","name:selenium, dissolved"],["selenium fish egg or ovary tissue","name:selenium, fish egg or ovary tissue"],["selenium fish muscle tissue","name:selenium, fish muscle tissue"],["selenium fish whole body tissue","name:selenium, fish whole body tissue"],["selenium monosulfide","cas:7446-34-6"],["selenium sulfide","cas:7446-34-6"],["selenium total","name:selenium, total"],["selenium total alert concentration","name:selenium - total alert concentration"],["selenium total guideline","name:selenium - total guideline"],["selenium v","name:selenium v"],["total selenium","name:total selenium"],["total selenium freshwater for flowing lotic waters","name:total selenium [freshwater – for flowing (lotic) waters]"],["total selenium freshwater for still standing lentic waters","name:total selenium [freshwater – for still/standing (lentic) waters]"],["total selenium marine","name:total selenium"]],"match":"exact+contains","order":"The place's own instruments first, then each place above it, each in its register's order","not_sent":{"rows":3,"names":["Selenious Acid"],"says":"3 rows share a parameter key with a longer name holding \"selenium\" but are printed under names without these words (that key is wider than the name): not sent. Ask for one by its name or CAS number."}},"total":119,"offset":0,"returned":50,"next_offset":50,"rows":[{"id":"a015f90fa9e1bd01","parameter":"Selenium","value":"3.1E+02","value_num":310,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7782-49-2","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","section":"TRRP Table 1, Residential Soil, TotSoilComb, 0.5 acre source area","page":20,"quote":null}},{"id":"f130e94f7f02a0fc","parameter":"Selenium","value":"2.3E+00","value_num":2.3,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7782-49-2","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","section":"TRRP Table 1, Residential Soil, GWSoilIng, 0.5 acre source area","page":20,"quote":null}},{"id":"e177209c0aa73231","parameter":"Selenium","value":"2.3E+02","value_num":230,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7782-49-2","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","section":"TRRP Table 1, Residential Soil, GWSoilClass 3, 0.5 acre source area","page":20,"quote":null}},{"id":"fefe34dc5f4ca640","parameter":"Selenium","value":"3.1E+02","value_num":310,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7782-49-2","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","section":"TRRP Table 1, Residential Soil, TotSoilComb, 30 acre source area","page":20,"quote":null}},{"id":"2f589cc86cd08d32","parameter":"Selenium","value":"1.1E+00","value_num":1.1,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7782-49-2","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","section":"TRRP Table 1, Residential Soil, GWSoilIng, 30 acre source area","page":20,"quote":null}},{"id":"826f53a676ee3a68","parameter":"Selenium","value":"1.1E+02","value_num":110,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7782-49-2","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","section":"TRRP Table 1, Residential Soil, GWSoilClass 3, 30 acre source area","page":20,"quote":null}},{"id":"cd7d8a39119e841f","parameter":"Selenium","value":"4.9E+03","value_num":4900,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7782-49-2","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","section":"TRRP Table 2, Commercial/Industrial Soil, TotSoilComb, 0.5 acre source area","page":35,"quote":null}},{"id":"688df3b481ebe9d1","parameter":"Selenium","value":"2.3E+00","value_num":2.3,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7782-49-2","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","section":"TRRP Table 2, Commercial/Industrial Soil, GWSoilIng, 0.5 acre source area","page":35,"quote":null}},{"id":"d777a28655dc1f03","parameter":"Selenium","value":"2.3E+02","value_num":230,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7782-49-2","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","section":"TRRP Table 2, Commercial/Industrial Soil, GWSoilClass 3, 0.5 acre source area","page":35,"quote":null}},{"id":"c98f275f31bd180c","parameter":"Selenium","value":"4.9E+03","value_num":4900,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7782-49-2","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","section":"TRRP Table 2, Commercial/Industrial Soil, TotSoilComb, 30 acre source area","page":35,"quote":null}},{"id":"17e93a285d706de6","parameter":"Selenium","value":"1.1E+00","value_num":1.1,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7782-49-2","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","section":"TRRP Table 2, Commercial/Industrial Soil, GWSoilIng, 30 acre source area","page":35,"quote":null}},{"id":"0a2f01d7da32f1a5","parameter":"Selenium","value":"1.1E+02","value_num":110,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7782-49-2","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","section":"TRRP Table 2, Commercial/Industrial Soil, GWSoilClass 3, 30 acre source area","page":35,"quote":null}},{"id":"a01f70187987491a","parameter":"Selenium","value":"5.0E-02","value_num":0.05,"unit":"mg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:7782-49-2","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","section":"TRRP Table 3, Groundwater, GWGWIng, Residential","page":47,"quote":null}},{"id":"caacf0cd283a43e6","parameter":"Selenium","value":"5.0E+00","value_num":5,"unit":"mg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:7782-49-2","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","section":"TRRP Table 3, Groundwater, GWGWClass3, Residential","page":47,"quote":null}},{"id":"2dcc7953ef8c6f9e","parameter":"Selenium","value":"5.0E-02","value_num":0.05,"unit":"mg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:7782-49-2","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","section":"TRRP Table 3, Groundwater, GWGWIng, Commercial/Industrial","page":47,"quote":null}},{"id":"07fa27c59db569bb","parameter":"Selenium","value":"5.0E+00","value_num":5,"unit":"mg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:7782-49-2","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","section":"TRRP Table 3, Groundwater, GWGWClass3, Commercial/Industrial","page":47,"quote":null}},{"id":"5a5448cdc3fe699d","parameter":"Selenium","value":"20","value_num":20,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7782-49-2","place":["US-TX"],"conditions":["receiving_water is freshwater","water in the state; acute criteria outside zones of initial dilution, chronic criteria in water with an aquatic life use of limited or greater, outside mixing zones and above critical low flow (30 TAC §307.6(c)(6))"],"cite":{"instrument":"us_tx_wqs","title":"Texas Surface Water Quality Standards, 30 TAC Chapter 307 (2022): §307.6 Table 1 aquatic life (freshwater and saltwater acute/chronic) and Table 2 human health; §307.7 Table 3 dissolved oxygen","issuer":"State of Texas, Texas Commission on Environmental Quality (TCEQ)","edition":"2022 Texas Surface Water Quality Standards (Rule Project No. 2020-014-307-OW), effective June 27, 2025, as US EPA posts them (cover dated July 1, 2025) with what EPA has approved for CWA purposes","source_url":"https://www.epa.gov/system/files/documents/2023-12/txwqs-2022.pdf","source_sha256":"88ff93dcfb277feec248541b2aa9a0f01cd3a747cda6e03d958344ee4a34ce5e","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"30 TAC §307.6(c) Table 1","page":39,"quote":null}},{"id":"319946afd813fdda","parameter":"Selenium","value":"5","value_num":5,"unit":"µg/L","statistic":"weekly_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7782-49-2","place":["US-TX"],"conditions":["receiving_water is freshwater","water in the state; acute criteria outside zones of initial dilution, chronic criteria in water with an aquatic life use of limited or greater, outside mixing zones and above critical low flow (30 TAC §307.6(c)(6))"],"cite":{"instrument":"us_tx_wqs","title":"Texas Surface Water Quality Standards, 30 TAC Chapter 307 (2022): §307.6 Table 1 aquatic life (freshwater and saltwater acute/chronic) and Table 2 human health; §307.7 Table 3 dissolved oxygen","issuer":"State of Texas, Texas Commission on Environmental Quality (TCEQ)","edition":"2022 Texas Surface Water Quality Standards (Rule Project No. 2020-014-307-OW), effective June 27, 2025, as US EPA posts them (cover dated July 1, 2025) with what EPA has approved for CWA purposes","source_url":"https://www.epa.gov/system/files/documents/2023-12/txwqs-2022.pdf","source_sha256":"88ff93dcfb277feec248541b2aa9a0f01cd3a747cda6e03d958344ee4a34ce5e","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"30 TAC §307.6(c) Table 1","page":39,"quote":null}},{"id":"af8ce6ea71f2dd1c","parameter":"Selenium","value":"564","value_num":564,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7782-49-2","place":["US-TX"],"conditions":["receiving_water is marine","water in the state; acute criteria outside zones of initial dilution, chronic criteria in water with an aquatic life use of limited or greater, outside mixing zones and above critical low flow (30 TAC §307.6(c)(6))"],"cite":{"instrument":"us_tx_wqs","title":"Texas Surface Water Quality Standards, 30 TAC Chapter 307 (2022): §307.6 Table 1 aquatic life (freshwater and saltwater acute/chronic) and Table 2 human health; §307.7 Table 3 dissolved oxygen","issuer":"State of Texas, Texas Commission on Environmental Quality (TCEQ)","edition":"2022 Texas Surface Water Quality Standards (Rule Project No. 2020-014-307-OW), effective June 27, 2025, as US EPA posts them (cover dated July 1, 2025) with what EPA has approved for CWA purposes","source_url":"https://www.epa.gov/system/files/documents/2023-12/txwqs-2022.pdf","source_sha256":"88ff93dcfb277feec248541b2aa9a0f01cd3a747cda6e03d958344ee4a34ce5e","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"30 TAC §307.6(c) Table 1","page":39,"quote":null}},{"id":"a7bda7f81517f9f7","parameter":"Selenium","value":"136","value_num":136,"unit":"µg/L","statistic":"weekly_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7782-49-2","place":["US-TX"],"conditions":["receiving_water is marine","water in the state; acute criteria outside zones of initial dilution, chronic criteria in water with an aquatic life use of limited or greater, outside mixing zones and above critical low flow (30 TAC §307.6(c)(6))"],"cite":{"instrument":"us_tx_wqs","title":"Texas Surface Water Quality Standards, 30 TAC Chapter 307 (2022): §307.6 Table 1 aquatic life (freshwater and saltwater acute/chronic) and Table 2 human health; §307.7 Table 3 dissolved oxygen","issuer":"State of Texas, Texas Commission on Environmental Quality (TCEQ)","edition":"2022 Texas Surface Water Quality Standards (Rule Project No. 2020-014-307-OW), effective June 27, 2025, as US EPA posts them (cover dated July 1, 2025) with what EPA has approved for CWA purposes","source_url":"https://www.epa.gov/system/files/documents/2023-12/txwqs-2022.pdf","source_sha256":"88ff93dcfb277feec248541b2aa9a0f01cd3a747cda6e03d958344ee4a34ce5e","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"30 TAC §307.6(c) Table 1","page":39,"quote":null}},{"id":"85491c7c671012e6","parameter":"Selenium","value":"501","value_num":50,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7782-49-2","place":["US-TX"],"conditions":["surface water designated or used for public drinking water supply, or a sole-source surface drinking water supply (30 TAC §307.6(d)(2)(A), Column A)"],"cite":{"instrument":"us_tx_wqs","title":"Texas Surface Water Quality Standards, 30 TAC Chapter 307 (2022): §307.6 Table 1 aquatic life (freshwater and saltwater acute/chronic) and Table 2 human health; §307.7 Table 3 dissolved oxygen","issuer":"State of Texas, Texas Commission on Environmental Quality (TCEQ)","edition":"2022 Texas Surface Water Quality Standards (Rule Project No. 2020-014-307-OW), effective June 27, 2025, as US EPA posts them (cover dated July 1, 2025) with what EPA has approved for CWA purposes","source_url":"https://www.epa.gov/system/files/documents/2023-12/txwqs-2022.pdf","source_sha256":"88ff93dcfb277feec248541b2aa9a0f01cd3a747cda6e03d958344ee4a34ce5e","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"30 TAC §307.6(d) Table 2","page":51,"quote":null}},{"id":"4ce7c3a5c7c206db","parameter":"Selenium","value":"1.0","value_num":1,"unit":"mg/L","direction":"max","kind":"threshold","medium":"leachate","level":"national","parameter_key":"cas:7782-49-2","place":["US"],"conditions":["(a) A solid waste (except manufactured gas plant waste) exhibits the characteristic of toxicity if, using the Toxicity Characteristic Leaching Procedure, test Method 1311 in “Test Methods for Evaluating Solid Waste, Physical/Chemical Methods,” EPA Publication SW-846, as incorporated by reference in § 260.11 of this chapter, the extract from a representative sample of the waste contains any of the contaminants listed in table 1 at the concentration equal to or greater than the respective value given in that table. Where the waste contains less than 0.5 percent filterable solids, the waste itself, after filtering using the methodology outlined in Method 1311, is considered to be the extract for the purpose of this section."],"cite":{"instrument":"us_40cfr261_24","title":"40 CFR 261.24 — Toxicity characteristic: Table 1, maximum concentration of contaminants for the toxicity characteristic (TCLP regulatory levels)","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"eCFR, 40 CFR 261.24 as of 2026-10-13 (title 40 up to date as of that day)","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-13/title-40.xml?part=261&section=261.24","source_sha256":"3a1ec9b0d3051c70e471e359275657b0fa6d98e80927d2217e82b2dbbca60961","fetched_at":"2026-10-15","section":"40 CFR 261.24, Table 1","page":null,"quote":"D010 Selenium 7782-49-2 1.0"}},{"id":"a776047018b35dd0","parameter":"Selenium","value":"0.82","value_num":0.82,"unit":"mg/L","statistic":"composite","direction":"max","kind":"limit","medium":"product","level":"national","parameter_key":"cas:7782-49-2","place":["US"],"conditions":["(a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS."],"cite":{"instrument":"us_40cfr268_48","title":"40 CFR 268.48 — Universal treatment standards: Table UTS, wastewater and nonwastewater treatment standards for the hazardous constituents of land-disposal-restricted wastes","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"eCFR, 40 CFR 268.48 as of 2026-10-13 (title 40 up to date as of that day; source note: 59 FR 48103, Sept. 19, 1994, as last amended at 76 FR 34156, June 13, 2011)","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-13/title-40.xml?part=268&section=268.48","source_sha256":"70b2e58a6b1e228e2c204acc69b69fab0d5a0347e35d569959073c3dc3ee4adb","fetched_at":"2026-10-15","section":"40 CFR 268.48, Table UTS, Inorganic Constituents, wastewater standard","page":null,"quote":"Selenium 7 7782-49-2 0.82 5.7 mg/l TCLP"}},{"id":"094732a9ac944067","parameter":"Selenium","value":"5.7 mg/l TCLP","value_num":5.7,"unit":"mg/L TCLP","statistic":"instant","direction":"max","kind":"limit","medium":"leachate","level":"national","parameter_key":"cas:7782-49-2","place":["US"],"conditions":["(a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS."],"cite":{"instrument":"us_40cfr268_48","title":"40 CFR 268.48 — Universal treatment standards: Table UTS, wastewater and nonwastewater treatment standards for the hazardous constituents of land-disposal-restricted wastes","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"eCFR, 40 CFR 268.48 as of 2026-10-13 (title 40 up to date as of that day; source note: 59 FR 48103, Sept. 19, 1994, as last amended at 76 FR 34156, June 13, 2011)","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-13/title-40.xml?part=268&section=268.48","source_sha256":"70b2e58a6b1e228e2c204acc69b69fab0d5a0347e35d569959073c3dc3ee4adb","fetched_at":"2026-10-15","section":"40 CFR 268.48, Table UTS, Inorganic Constituents, nonwastewater standard","page":null,"quote":"Selenium 7 7782-49-2 0.82 5.7 mg/l TCLP"}},{"id":"cb845ee83a2ef2cf","parameter":"Selenium (T)","value":"0.0015","value_num":0.0015,"unit":"Kg/kkg (or pounds per/1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7782-49-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart AJ—Copper Salts Production Subcategory","existing sources (BPT)","table: Subpart AJ—Copper Sulfate, Copper Chloride, Copper Iodide, Copper Nitrate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.362 (BPT)","page":null,"quote":"Selenium (T) 0.0015 0.00050"}},{"id":"44a749a15f97f4ad","parameter":"Selenium (T)","value":"0.00050","value_num":0.0005,"unit":"Kg/kkg (or pounds per/1,000 lb) of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7782-49-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart AJ—Copper Salts Production Subcategory","existing sources (BPT)","table: Subpart AJ—Copper Sulfate, Copper Chloride, Copper Iodide, Copper Nitrate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.362 (BPT)","page":null,"quote":"Selenium (T) 0.0015 0.00050"}},{"id":"5b29983b6042c6d2","parameter":"Selenium (T)","value":"0.093","value_num":0.093,"unit":"Kg/kkg (or pounds per/1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7782-49-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart AJ—Copper Salts Production Subcategory","existing sources (BPT)","table: Subpart AJ—Copper Carbonate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.362 (BPT)","page":null,"quote":"Selenium (T) 0.093 0.031"}},{"id":"4081cfaa0a050ad1","parameter":"Selenium (T)","value":"0.031","value_num":0.031,"unit":"Kg/kkg (or pounds per/1,000 lb) of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7782-49-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart AJ—Copper Salts Production Subcategory","existing sources (BPT)","table: Subpart AJ—Copper Carbonate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.362 (BPT)","page":null,"quote":"Selenium (T) 0.093 0.031"}},{"id":"7bfc40550ab780c2","parameter":"Selenium(T)","value":"1.6","value_num":1.6,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7782-49-2","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart AJ—Copper Salts Production Subcategory","existing sources (PSES)","table: Subpart AJ—Copper Sulfate, Copper Chloride, Copper Iodide, Copper Nitrate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.364 (PSES)","page":null,"quote":"Selenium(T) 1.6 0.53"}},{"id":"f2ac662b0f5aebf8","parameter":"Selenium(T)","value":"0.53","value_num":0.53,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7782-49-2","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart AJ—Copper Salts Production Subcategory","existing sources (PSES)","table: Subpart AJ—Copper Sulfate, Copper Chloride, Copper Iodide, Copper Nitrate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.364 (PSES)","page":null,"quote":"Selenium(T) 1.6 0.53"}},{"id":"8e4bf3493c329a3e","parameter":"Selenium (T)","value":"1.6","value_num":1.6,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7782-49-2","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart AJ—Copper Salts Production Subcategory","existing sources (PSES)","table: Subpart AJ—Copper Carbonate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.364 (PSES)","page":null,"quote":"Selenium (T) 1.6 0.53"}},{"id":"5bda98f4ed8e903e","parameter":"Selenium (T)","value":"0.53","value_num":0.53,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7782-49-2","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart AJ—Copper Salts Production Subcategory","existing sources (PSES)","table: Subpart AJ—Copper Carbonate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.364 (PSES)","page":null,"quote":"Selenium (T) 1.6 0.53"}},{"id":"7661c863812b4e76","parameter":"Selenium (T)","value":"0.11","value_num":0.11,"unit":"Kg/kkg (or pounds per/1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7782-49-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart BL—Cadmium Pigments and Salts Production Subcategory","existing sources (BPT)","table: Subpart BL—Cadmium Pigments"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.642 (BPT)","page":null,"quote":"Selenium (T) 0.11 0.037"}},{"id":"22f249104a6d0d6b","parameter":"Selenium (T)","value":"0.037","value_num":0.037,"unit":"Kg/kkg (or pounds per/1,000 lb) of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7782-49-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart BL—Cadmium Pigments and Salts Production Subcategory","existing sources (BPT)","table: Subpart BL—Cadmium Pigments"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.642 (BPT)","page":null,"quote":"Selenium (T) 0.11 0.037"}},{"id":"8ebd23ea91fd0ce8","parameter":"Selenium (T)","value":"1.1","value_num":1.1,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7782-49-2","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart BL—Cadmium Pigments and Salts Production Subcategory","existing sources (PSES)","table: Subpart BL—Cadmium Pigments"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.644 (PSES)","page":null,"quote":"Selenium (T) 1.1 0.40"}},{"id":"13c9bd07cf4e21a2","parameter":"Selenium (T)","value":"0.40","value_num":0.4,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7782-49-2","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart BL—Cadmium Pigments and Salts Production Subcategory","existing sources (PSES)","table: Subpart BL—Cadmium Pigments"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.644 (PSES)","page":null,"quote":"Selenium (T) 1.1 0.40"}},{"id":"a0564ff24613cde7","parameter":"Selenium (T)","value":"1.1","value_num":1.1,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7782-49-2","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart BL—Cadmium Pigments and Salts Production Subcategory","existing sources (PSES)","table: Subpart BL—Cadmium Salts"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.644 (PSES)","page":null,"quote":"Selenium (T) 1.1 0.40"}},{"id":"0c996e441d926299","parameter":"Selenium (T)","value":"0.40","value_num":0.4,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7782-49-2","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart BL—Cadmium Pigments and Salts Production Subcategory","existing sources (PSES)","table: Subpart BL—Cadmium Salts"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.644 (PSES)","page":null,"quote":"Selenium (T) 1.1 0.40"}},{"id":"613be374439c7257","parameter":"Se","value":"0.08","value_num":0.08,"unit":"(1) English Units (pounds per 1,000 pounds of product)","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7782-49-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart H—Primary Zinc Subcategory","existing sources (BPT)","table: Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.82 (BPT)","page":null,"quote":"Se 0.08 0.04"}},{"id":"994dc49dc44cb47c","parameter":"Se","value":"0.04","value_num":0.04,"unit":"(1) English Units (pounds per 1,000 pounds of product)","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7782-49-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart H—Primary Zinc Subcategory","existing sources (BPT)","table: Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.82 (BPT)","page":null,"quote":"Se 0.08 0.04"}},{"id":"c8ec69684978314b","parameter":"Selenium","value":"0.570","value_num":0.57,"unit":"mg/kg (pounds per million pounds) of molybdenum sulfide leached","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7782-49-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart S—Primary Molybdenum and Rhenium Subcategory","existing sources (BPT)","(a) Molybdenum sulfide leachate.","table: BPT Limitations for the Primary Molybdenum Rhenium Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.212 (BPT)","page":null,"quote":"Selenium 0.570 0.255"}},{"id":"f28f83ce71ee7753","parameter":"Selenium","value":"0.255","value_num":0.255,"unit":"mg/kg (pounds per million pounds) of molybdenum sulfide leached","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7782-49-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart S—Primary Molybdenum and Rhenium Subcategory","existing sources (BPT)","(a) Molybdenum sulfide leachate.","table: BPT Limitations for the Primary Molybdenum Rhenium Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.212 (BPT)","page":null,"quote":"Selenium 0.570 0.255"}},{"id":"41fc13ab6be7f8bf","parameter":"Selenium","value":"2.065","value_num":2.065,"unit":"mg/kg (pounds per million pounds) of molybdenum sulfide roasted","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7782-49-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart S—Primary Molybdenum and Rhenium Subcategory","existing sources (BPT)","(b) Roaster SO 2 scrubber.","table: BPT Limitations for the Primary Molybdenum and Rhenium Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.212 (BPT)","page":null,"quote":"Selenium 2.065 0.924"}},{"id":"6aa87c8614c6f359","parameter":"Selenium","value":"0.924","value_num":0.924,"unit":"mg/kg (pounds per million pounds) of molybdenum sulfide roasted","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7782-49-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart S—Primary Molybdenum and Rhenium Subcategory","existing sources (BPT)","(b) Roaster SO 2 scrubber.","table: BPT Limitations for the Primary Molybdenum and Rhenium Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.212 (BPT)","page":null,"quote":"Selenium 2.065 0.924"}},{"id":"2b5eec0536c88aef","parameter":"Selenium","value":"14.250","value_num":14.25,"unit":"mg/kg (pounds per million pounds) of molybdenum contained in molybdic oxide leached","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7782-49-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart S—Primary Molybdenum and Rhenium Subcategory","existing sources (BPT)","(c) Molybdic oxide leachate.","table: BPT Limitations for the Primary Molybdenum and Rhenium Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.212 (BPT)","page":null,"quote":"Selenium 14.250 6.371"}},{"id":"a8fa649b814086d8","parameter":"Selenium","value":"6.371","value_num":6.371,"unit":"mg/kg (pounds per million pounds) of molybdenum contained in molybdic oxide leached","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7782-49-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart S—Primary Molybdenum and Rhenium Subcategory","existing sources (BPT)","(c) Molybdic oxide leachate.","table: BPT Limitations for the Primary Molybdenum and Rhenium Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.212 (BPT)","page":null,"quote":"Selenium 14.250 6.371"}},{"id":"d3862df0d7f50120","parameter":"Selenium","value":"28.170","value_num":28.17,"unit":"mg/kg (pounds per million pounds) of molybdenum metal powder produced","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7782-49-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart S—Primary Molybdenum and Rhenium Subcategory","existing sources (BPT)","(d) Hydrogen reduction furnace scrubber.","table: BPT Limitations for the Primary Molybdenum and Rhenium Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.212 (BPT)","page":null,"quote":"Selenium 28.170 12.600"}},{"id":"f20038ab241854a3","parameter":"Selenium","value":"12.600","value_num":12.6,"unit":"mg/kg (pounds per million pounds) of molybdenum metal powder produced","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7782-49-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart S—Primary Molybdenum and Rhenium Subcategory","existing sources (BPT)","(d) Hydrogen reduction furnace scrubber.","table: BPT Limitations for the Primary Molybdenum and Rhenium Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.212 (BPT)","page":null,"quote":"Selenium 28.170 12.600"}},{"id":"ec3be2f3f078a806","parameter":"Selenium","value":"0.881","value_num":0.881,"unit":"mg/kg (pounds per million pounds) of molybdenum sulfide roasted","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7782-49-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart S—Primary Molybdenum and Rhenium Subcategory","existing sources (BPT)","(e) Depleted rhenium scrubbing solution.","table: BPT Limitations for the Primary Molybdenum and Rhenium Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.212 (BPT)","page":null,"quote":"Selenium 0.881 0.394"}},{"id":"1d33826c7d548844","parameter":"Selenium","value":"0.394","value_num":0.394,"unit":"mg/kg (pounds per million pounds) of molybdenum sulfide roasted","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7782-49-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart S—Primary Molybdenum and Rhenium Subcategory","existing sources (BPT)","(e) Depleted rhenium scrubbing solution.","table: BPT Limitations for the Primary Molybdenum and Rhenium Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.212 (BPT)","page":null,"quote":"Selenium 0.881 0.394"}}],"next":[{"tool":"check_values","says":"Has your user measured this? check_values sets each of their results beside every row held here, with a verdict and the row's cite.","arguments":{"place":"US-TX"},"needs":{"rows":"Your user's measured results, as their table prints them: [{parameter: \"selenium\", value, unit}, ...], any other parameters too."},"post":"/api/v1/check"},{"tool":"read_certificate","says":"Has your user a laboratory certificate? read_certificate reads every row it prints, each with its page, and checks them against these limits.","arguments":{"place":"US-TX"},"needs":{"content_base64":"The laboratory's certificate (PDF) or its XLSX, XLS or CSV export, as base64; or file_url, a public https address of it."},"post":"/api/v1/certificate"}]}