{"query":{"parameter":"propylene oxide","place":"US-TX","medium":null,"statistic":null,"kind":null},"searched":{"places":["US-TX","US"],"parameter_keys":["cas:75-56-9","cas:30704-64-4","cas:68610-97-9","cas:153795-76-7","cas:37523-33-4","cas:25791-96-2","cas:9082-00-2","cas:9087-53-0","cas:68649-29-6","cas:68201-88-7","cas:68400-72-6","cas:68400-71-5","cas:70613-36-4","cas:134180-76-0","cas:71343-01-6","cas:68891-11-2","cas:58050-75-2","cas:129828-31-5","cas:178603-70-8","cas:1802633-48-2","cas:67905-91-3","cas:38172-91-7","cas:36484-54-5","cas:67800-94-6","cas:68332-78-5","cas:68186-54-9","cas:68036-92-0","cas:68036-95-3","cas:70880-56-7"],"names_matched":[["propylene oxide","cas:75-56-9"],["formaldehyde p tert butylphenol propylene oxide ethylene oxide polymer","cas:30704-64-4"],["formaldehyde polymer with nonylphenol reaction products with diethanolamine and propylene oxide","cas:68610-97-9"],["formaldehyde polymers with branched 4 nonylphenol ethylene oxide and propylene oxide","cas:153795-76-7"],["formaldehyde propylene oxide p nonylphenol polymer","cas:37523-33-4"],["glycerol propylene oxide polymer","cas:25791-96-2"],["p tert butylphenol formaldehyde resin copolymer with ethylene oxide and propylene oxide","cas:30704-64-4"],["propylene oxide ethylene oxide polymer ether with glycerol 3 1","cas:9082-00-2"],["propylene oxide ethylene oxide polymer hexadecyl ether","cas:9087-53-0"],["propylene oxide ethylene oxide polymer mono c10 16 alkyl ethers phosphates","cas:68649-29-6"],["1 6 hexanediamine polymer with 2 chloromethyl oxirane 2 methyloxirane and oxirane hydrochloride","cas:68201-88-7","methyloxirane"],["1 6 hexanediamine polymer with chloromethyl oxirane methyloxirane and oxirane hydrochloride","cas:68201-88-7","methyloxirane"],["2 butenedioic acid 2e polymer with methyloxirane and oxirane","cas:68400-72-6","methyloxirane"],["2 butenedioic acid 2e polymer with methyloxirane oxirane and 1 2 3 propanetriol","cas:68400-71-5","methyloxirane"],["2 e butanedioic acid polymer with methyloxirane and oxirane","cas:68400-72-6","methyloxirane"],["2 e butanedioic acid polymer with methyloxirane and oxirane and 1 2 3 propanetriol","cas:68400-71-5","methyloxirane"],["2 methyloxirane polymer with 2 2 1 methylethylidene bis 4 1 phenyleneoxymethylene bis oxirane and oxirane","cas:70613-36-4","methyloxirane"],["2 methyloxirane polymer with mono 3 1 3 3 3 tetramethyl 1 trimethylsilyl oxy 1 disiloxanyl propyl oxirane ether","cas:134180-76-0","methyloxirane"],["2 methyloxirane polymer with oxirane ether with 1 2 3 propanetriol 3 1 reaction products with tdi","cas:71343-01-6","methyloxirane"],["2 methyloxirane polymer with oxirane mono nonylphenyl ether branched","cas:68891-11-2","methyloxirane"],["2 propenenitrile polymer with ethenylbenzene methyloxirane and oxirane","cas:58050-75-2","methyloxirane"],["2 propenoic acid polymer with 4 1 1 dimethylethyl phenol formaldehyde 2 5 furandione 2 methyloxirane 4 nonylphenol and oxirane","cas:129828-31-5","methyloxirane"],["2 propenoic acid polymer with 4 1 1 dimethylethyl phenol formaldehyde 2 5 furandione 2 methyloxirane and oxirane","cas:178603-70-8","methyloxirane"],["2 propenoic acid polymer with 4 1 1 dimethylethyl phenol formaldehyde 2 5 furandione methyloxirane 4 nonylphenol and oxirane","cas:129828-31-5","methyloxirane"],["2 propenoic acid polymer with 4 1 1 dimethylethyl phenol formaldehyde 2 5 furandione methyloxirane and oxirane","cas:178603-70-8","methyloxirane"],["2 propenoic acid polymer with ethylenediamine oxirane methyloxirane 2 5 furandione methyl oxirane and oxirane","cas:1802633-48-2","methyloxirane"],["2 propenoic acid polymer with formaldehyde 2 5 furandione methyloxirane 4 nonylphenol and oxirane","cas:67905-91-3","methyloxirane"],["2 propyn 1 ol compound with methyloxirane","cas:38172-91-7","methyloxirane"],["4 4 1 methylethylidene bisphenol polymer with chloromethyl oxirane and methyloxirane","cas:36484-54-5","methyloxirane"],["benzenediamine ar methyl polymer with methyloxirane and oxirane","cas:67800-94-6","methyloxirane"],["formaldehyde polymer with 2 methyloxirane and 4 nonylphenol","cas:37523-33-4","methyloxirane"],["methyloxirane polymer with oxirane didodecylbenzenesulfonate","cas:68332-78-5","methyloxirane"],["methyloxirane polymer with oxirane e 2 butenedioate","cas:68186-54-9","methyloxirane"],["methyloxirane polymer with oxirane ether with 1 2 3 propanetriol 3 1 ether with chloromethyl oxirane polymer with 4 4 1 methylethylidene bis phenol","cas:68036-92-0","methyloxirane"],["methyloxirane polymer with oxirane ether with chloromethyl oxirane polymer with 4 4 1 methylethylidene bis phenol","cas:68036-95-3","methyloxirane"],["methyloxirane polymer with oxirane mono2 4 6 tris 1 phenylethyl phenyl ether","cas:70880-56-7","methyloxirane"],["phenol 4 4 1 methylethylidene bis polymer with chloromethyl oxirane and methyloxirane","cas:36484-54-5","methyloxirane"],["polymere de phosphates d ethers mono c10 c16 alkyle oxirane et de methyloxirane","cas:68649-29-6","methyloxirane"],["polymere d oxyde de propylene d oxyde d ethylene et de toluenediaminea","cas:67800-94-6","propylene oxyde de"]],"match":"exact+contains","order":"The place's own instruments first, then each place above it, each in its register's order"},"total":32,"offset":0,"returned":32,"next_offset":null,"rows":[{"id":"48f87e8605e754e5","parameter":"Propylene oxide","value":"2.0E+01","value_num":20,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:75-56-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 1, Residential Soil, TotSoilComb, 0.5 acre source area","page":20,"quote":null}},{"id":"c5292c8aaebb4b2e","parameter":"Propylene oxide","value":"7.5E-03","value_num":0.0075,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:75-56-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 1, Residential Soil, GWSoilIng, 0.5 acre source area","page":20,"quote":null}},{"id":"483ce0af56a0f2c1","parameter":"Propylene oxide","value":"7.5E-01","value_num":0.75,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:75-56-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 1, Residential Soil, GWSoilClass 3, 0.5 acre source area","page":20,"quote":null}},{"id":"49c8f6e418de557a","parameter":"Propylene oxide","value":"9.7E+01","value_num":97,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:75-56-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 1, Residential Soil, AirSoilInh-V, 0.5 acre source area","page":20,"quote":null}},{"id":"052f506a1088a720","parameter":"Propylene oxide","value":"3.1E+03","value_num":3100,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:75-56-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 1, Residential Soil, AirGW-SoilInh-V, 0.5 acre source area","page":20,"quote":null}},{"id":"8d4ad317d295a04e","parameter":"Propylene oxide","value":"1.7E+01","value_num":17,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:75-56-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 1, Residential Soil, TotSoilComb, 30 acre source area","page":20,"quote":null}},{"id":"2b3c0b4df3b832b7","parameter":"Propylene oxide","value":"3.8E-03","value_num":0.0038,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:75-56-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 1, Residential Soil, GWSoilIng, 30 acre source area","page":20,"quote":null}},{"id":"c35515dd0e04d9e3","parameter":"Propylene oxide","value":"3.8E-01","value_num":0.38,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:75-56-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 1, Residential Soil, GWSoilClass 3, 30 acre source area","page":20,"quote":null}},{"id":"99643e5df8a7ac66","parameter":"Propylene oxide","value":"5.0E+01","value_num":50,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:75-56-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 1, Residential Soil, AirSoilInh-V, 30 acre source area","page":20,"quote":null}},{"id":"e98a4f80eaef139e","parameter":"Propylene oxide","value":"2.0E+02","value_num":200,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:75-56-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 1, Residential Soil, AirGW-SoilInh-V, 30 acre source area","page":20,"quote":null}},{"id":"89b3899bc1d39569","parameter":"Propylene oxide","value":"6.9E+01","value_num":69,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:75-56-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 2, Commercial/Industrial Soil, TotSoilComb, 0.5 acre source area","page":35,"quote":null}},{"id":"14f35ef9c74e8722","parameter":"Propylene oxide","value":"1.7E-02","value_num":0.017,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:75-56-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 2, Commercial/Industrial Soil, GWSoilIng, 0.5 acre source area","page":35,"quote":null}},{"id":"ca6023501f2e6b8c","parameter":"Propylene oxide","value":"1.7E+00","value_num":1.7,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:75-56-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 2, Commercial/Industrial Soil, GWSoilClass 3, 0.5 acre source area","page":35,"quote":null}},{"id":"a3a5a99cc7a5fd36","parameter":"Propylene oxide","value":"1.6E+02","value_num":160,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:75-56-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 2, Commercial/Industrial Soil, AirSoilInh-V, 0.5 acre source area","page":35,"quote":null}},{"id":"593c8e9bd1ffdcdf","parameter":"Propylene oxide","value":"5.3E+03","value_num":5300,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:75-56-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 2, Commercial/Industrial Soil, AirGW-SoilInh-V, 0.5 acre source area","page":35,"quote":null}},{"id":"6e334e9c7cdb152b","parameter":"Propylene oxide","value":"4.9E+01","value_num":49,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:75-56-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 2, Commercial/Industrial Soil, TotSoilComb, 30 acre source area","page":35,"quote":null}},{"id":"de5ddf9ca5f7c508","parameter":"Propylene oxide","value":"8.4E-03","value_num":0.0084,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:75-56-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 2, Commercial/Industrial Soil, GWSoilIng, 30 acre source area","page":35,"quote":null}},{"id":"6708e16e97f5917b","parameter":"Propylene oxide","value":"8.4E-01","value_num":0.84,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:75-56-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 2, Commercial/Industrial Soil, GWSoilClass 3, 30 acre source area","page":35,"quote":null}},{"id":"24462fbb509173af","parameter":"Propylene oxide","value":"8.4E+01","value_num":84,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:75-56-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 2, Commercial/Industrial Soil, AirSoilInh-V, 30 acre source area","page":35,"quote":null}},{"id":"52b9bd38924ccd8c","parameter":"Propylene oxide","value":"3.4E+02","value_num":340,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:75-56-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 2, Commercial/Industrial Soil, AirGW-SoilInh-V, 30 acre source area","page":35,"quote":null}},{"id":"f1c27f43fb41d0af","parameter":"Propylene oxide","value":"3.8E-03","value_num":0.0038,"unit":"mg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:75-56-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 3, Groundwater, GWGWIng, Residential","page":47,"quote":null}},{"id":"55bb70d33f4f0871","parameter":"Propylene oxide","value":"3.8E-01","value_num":0.38,"unit":"mg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:75-56-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 3, Groundwater, GWGWClass3, Residential","page":47,"quote":null}},{"id":"779622e3351e2df5","parameter":"Propylene oxide","value":"1.6E+03","value_num":1600,"unit":"mg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:75-56-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 3, Groundwater, AirGWInh-V 0.5 acre source area, Residential","page":47,"quote":null}},{"id":"9f1adeaabbd4f7c7","parameter":"Propylene oxide","value":"2.0E+02","value_num":200,"unit":"mg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:75-56-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 3, Groundwater, AirGWInh-V 30 acre source area, Residential","page":47,"quote":null}},{"id":"e86d8f9cb1ef009f","parameter":"Propylene oxide","value":"8.5E-03","value_num":0.0085,"unit":"mg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:75-56-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 3, Groundwater, GWGWIng, Commercial/Industrial","page":47,"quote":null}},{"id":"7c684651b5388271","parameter":"Propylene oxide","value":"8.5E-01","value_num":0.85,"unit":"mg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:75-56-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 3, Groundwater, GWGWClass3, Commercial/Industrial","page":47,"quote":null}},{"id":"3e93493694d713e1","parameter":"Propylene oxide","value":"2.7E+03","value_num":2700,"unit":"mg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:75-56-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 3, Groundwater, AirGWInh-V 0.5 acre source area, Commercial/Industrial","page":47,"quote":null}},{"id":"098b884579de4207","parameter":"Propylene oxide","value":"3.4E+02","value_num":340,"unit":"mg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:75-56-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 3, Groundwater, AirGWInh-V 30 acre source area, Commercial/Industrial","page":47,"quote":null}},{"id":"ba38c7e824f6e210","parameter":"Propylene Oxide","value":"2.1","value_num":2.1,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"national","parameter_key":"cas:75-56-9","place":["US"],"conditions":["Resident Soil (mg/kg)"],"cite":{"instrument":"us_rsl_soil","title":"US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Soil","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"November 2024","source_url":"https://semspub.epa.gov/src/document/HQ/405270","source_sha256":"0160dc81b4f55d738a354a74de92488f149946ebfa7c6a6c64592f45348043d7","fetched_at":"2026-09-19","source_status":{"checked":"2026-10-15","status":"not verified"},"section":null,"page":null,"quote":null,"table":"sols","column":"residentiel"}},{"id":"d3ef5ade265ad84e","parameter":"Propylene Oxide","value":"9.7","value_num":9.7,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"national","parameter_key":"cas:75-56-9","place":["US"],"conditions":["Industrial Soil (mg/kg)"],"cite":{"instrument":"us_rsl_soil","title":"US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Soil","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"November 2024","source_url":"https://semspub.epa.gov/src/document/HQ/405270","source_sha256":"0160dc81b4f55d738a354a74de92488f149946ebfa7c6a6c64592f45348043d7","fetched_at":"2026-09-19","source_status":{"checked":"2026-10-15","status":"not verified"},"section":null,"page":null,"quote":null,"table":"sols","column":"industriel"}},{"id":"e2c066d65a8f5f20","parameter":"Propylene Oxide","value":"5.6e-05","value_num":0.000056,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"national","parameter_key":"cas:75-56-9","place":["US"],"conditions":["Protection of Groundwater SSLs: Risk-based SSL (mg/kg); SSL values are based on DAF=1"],"cite":{"instrument":"us_rsl_soil","title":"US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Soil","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"November 2024","source_url":"https://semspub.epa.gov/src/document/HQ/405270","source_sha256":"0160dc81b4f55d738a354a74de92488f149946ebfa7c6a6c64592f45348043d7","fetched_at":"2026-09-19","source_status":{"checked":"2026-10-15","status":"not verified"},"section":null,"page":null,"quote":null,"table":"ssl","column":"risque"}},{"id":"4eb26a48a2c64aac","parameter":"Propylene Oxide","value":"0.27","value_num":0.27,"unit":"µg/L","direction":"max","kind":"guideline","medium":"drinking_water","level":"national","parameter_key":"cas:75-56-9","place":["US"],"conditions":["Tap Water (ug/L): Regional Screening Level (RSL) Summary Table (TR=1E-06, HQ=1) November 2024"],"cite":{"instrument":"us_rsl_tapwater","title":"US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Tap Water","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"November 2024","source_url":"https://semspub.epa.gov/src/document/HQ/405270","source_sha256":"0160dc81b4f55d738a354a74de92488f149946ebfa7c6a6c64592f45348043d7","fetched_at":"2026-09-19","source_status":{"checked":"2026-10-15","status":"not verified"},"section":null,"page":null,"quote":null,"table":"eau","column":"eau_robinet"}}],"next":[{"tool":"check_values","says":"Has your user measured this? check_values sets each of their results beside every row held here, with a verdict and the row's cite.","arguments":{"place":"US-TX"},"needs":{"rows":"Your user's measured results, as their table prints them: [{parameter: \"propylene oxide\", value, unit}, ...], any other parameters too."},"post":"/api/v1/check"},{"tool":"read_certificate","says":"Has your user a laboratory certificate? read_certificate reads every row it prints, each with its page, and checks them against these limits.","arguments":{"place":"US-TX"},"needs":{"content_base64":"The laboratory's certificate (PDF) or its XLSX, XLS or CSV export, as base64; or file_url, a public https address of it."},"post":"/api/v1/certificate"}]}