{"query":{"parameter":"phenolic compounds 4aap","place":"US-NE","medium":null,"statistic":null,"kind":null},"searched":{"places":["US-NE","US"],"parameter_keys":["name:phenolic compounds"],"names_matched":[["phenolic compounds 4aap","name:phenolic compounds"]],"match":"exact","order":"The place's own instruments first, then each place above it, each in its register's order"},"total":88,"offset":0,"returned":50,"next_offset":50,"rows":[{"id":"7bbbd8a9201f8ad7","parameter":"Phenolic compounds","value":"0.168","value_num":0.168,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.12 (BPT)","page":null,"quote":"Phenolic compounds 0.168 0.076"}},{"id":"24f2f1ebf7182fc4","parameter":"Phenolic compounds","value":"0.076","value_num":0.076,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.12 (BPT)","page":null,"quote":"Phenolic compounds 0.168 0.076"}},{"id":"9e969aaf7c95dc8a","parameter":"Phenolic compounds (4AAP)","value":"0.35","value_num":0.35,"unit":"kilograms per 1,000 m³ of flow","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BPT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by th…"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.12 (BPT)","page":null,"quote":"Phenolic compounds (4AAP) 0.35 0.17"}},{"id":"a4b41077e9725aa1","parameter":"Phenolic compounds (4AAP)","value":"0.17","value_num":0.17,"unit":"kilograms per 1,000 m³ of flow","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BPT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by th…"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.12 (BPT)","page":null,"quote":"Phenolic compounds (4AAP) 0.35 0.17"}},{"id":"2ca6af9ef705e4b1","parameter":"Phenolic compounds (4AAP)","value":"0.037","value_num":0.037,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Crude"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Crude 0.037 0.009"}},{"id":"76a1835edda8489c","parameter":"Phenolic compounds (4AAP)","value":"0.009","value_num":0.009,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Crude"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Crude 0.037 0.009"}},{"id":"05aa1b1b60b3213b","parameter":"Phenolic compounds (4AAP)","value":"0.419","value_num":0.419,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Cracking and coking"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Cracking and coking 0.419 0.102"}},{"id":"1eec5a34464e400e","parameter":"Phenolic compounds (4AAP)","value":"0.102","value_num":0.102,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Cracking and coking"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Cracking and coking 0.419 0.102"}},{"id":"7ac2842a9ff8bab6","parameter":"Phenolic compounds (4AAP)","value":"0.226","value_num":0.226,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Asphalt"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Asphalt 0.226 0.055"}},{"id":"c73f447576513fbc","parameter":"Phenolic compounds (4AAP)","value":"0.055","value_num":0.055,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Asphalt"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Asphalt 0.226 0.055"}},{"id":"b714c4a99ef93d75","parameter":"Phenolic compounds (4AAP)","value":"1.055","value_num":1.055,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Lube"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Lube 1.055 0.257"}},{"id":"c6780b6aa3630740","parameter":"Phenolic compounds (4AAP)","value":"0.257","value_num":0.257,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Lube"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Lube 1.055 0.257"}},{"id":"7e9455900334e31e","parameter":"Phenolic compounds (4AAP)","value":"0.377","value_num":0.377,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Reforming and alkylation"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Reforming and alkylation 0.377 0.092"}},{"id":"a4e8ab799ee6a54b","parameter":"Phenolic compounds (4AAP)","value":"0.092","value_num":0.092,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Reforming and alkylation"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Reforming and alkylation 0.377 0.092"}},{"id":"92ccc83f536cb053","parameter":"Phenolic compounds (4AAP)","value":"0.35","value_num":0.35,"unit":"kilograms per 1,000 m³ of flow","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the permit writer times the …"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Phenolic compounds (4AAP) 0.35 0.17"}},{"id":"1fd53292149811d4","parameter":"Phenolic compounds (4AAP)","value":"0.17","value_num":0.17,"unit":"kilograms per 1,000 m³ of flow","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the permit writer times the …"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Phenolic compounds (4AAP) 0.35 0.17"}},{"id":"2b6fdf4adada9d6c","parameter":"Phenolic compounds","value":"0.088","value_num":0.088,"unit":"kilograms per cubic meter of flow","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","new sources (NSPS)","(a) Any new source subject to this subpart must achieve the following new source performance standards (NSPS):"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.16 (NSPS)","page":null,"quote":"Phenolic compounds 0.088 0.043"}},{"id":"141c92a8af047917","parameter":"Phenolic compounds","value":"0.043","value_num":0.043,"unit":"kilograms per cubic meter of flow","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","new sources (NSPS)","(a) Any new source subject to this subpart must achieve the following new source performance standards (NSPS):"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.16 (NSPS)","page":null,"quote":"Phenolic compounds 0.088 0.043"}},{"id":"60fefec40f4912d8","parameter":"Phenolic compounds","value":"0.21","value_num":0.21,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.22 (BPT)","page":null,"quote":"Phenolic compounds 0.21 0.10"}},{"id":"ce44af81fac62148","parameter":"Phenolic compounds","value":"0.10","value_num":0.1,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.22 (BPT)","page":null,"quote":"Phenolic compounds 0.21 0.10"}},{"id":"32770d675827e177","parameter":"Phenolic compounds (4AAP)","value":"0.35","value_num":0.35,"unit":"kilograms per 1,000 m³ of flow","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BPT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by th…"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.22 (BPT)","page":null,"quote":"Phenolic compounds (4AAP) 0.35 0.17"}},{"id":"2b798c27a95a9e68","parameter":"Phenolic compounds (4AAP)","value":"0.17","value_num":0.17,"unit":"kilograms per 1,000 m³ of flow","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BPT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by th…"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.22 (BPT)","page":null,"quote":"Phenolic compounds (4AAP) 0.35 0.17"}},{"id":"83075d86117f3514","parameter":"Phenolic compounds (4AAP)","value":"0.037","value_num":0.037,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Crude"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.23 (BAT)","page":null,"quote":"Crude 0.037 0.009"}},{"id":"e055666499f2e20e","parameter":"Phenolic compounds (4AAP)","value":"0.009","value_num":0.009,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Crude"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.23 (BAT)","page":null,"quote":"Crude 0.037 0.009"}},{"id":"37d5b972e7c308db","parameter":"Phenolic compounds (4AAP)","value":"0.419","value_num":0.419,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Cracking and coking"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.23 (BAT)","page":null,"quote":"Cracking and coking 0.419 0.102"}},{"id":"a21442cfde90be4f","parameter":"Phenolic compounds (4AAP)","value":"0.102","value_num":0.102,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Cracking and coking"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.23 (BAT)","page":null,"quote":"Cracking and coking 0.419 0.102"}},{"id":"bb96455aa59fd8ff","parameter":"Phenolic compounds (4AAP)","value":"0.226","value_num":0.226,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Asphalt"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.23 (BAT)","page":null,"quote":"Asphalt 0.226 0.055"}},{"id":"e925212e34d91093","parameter":"Phenolic compounds (4AAP)","value":"0.055","value_num":0.055,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Asphalt"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.23 (BAT)","page":null,"quote":"Asphalt 0.226 0.055"}},{"id":"bfa2b1ccb9bcf524","parameter":"Phenolic compounds (4AAP)","value":"1.055","value_num":1.055,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Lube"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.23 (BAT)","page":null,"quote":"Lube 1.055 0.257"}},{"id":"addcc571ce87ab95","parameter":"Phenolic compounds (4AAP)","value":"0.257","value_num":0.257,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Lube"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.23 (BAT)","page":null,"quote":"Lube 1.055 0.257"}},{"id":"1354f3eca2e0f1ed","parameter":"Phenolic compounds (4AAP)","value":"0.377","value_num":0.377,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Reforming and alkylation"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.23 (BAT)","page":null,"quote":"Reforming and alkylation 0.377 0.092"}},{"id":"00df5bfcf4e12c27","parameter":"Phenolic compounds (4AAP)","value":"0.092","value_num":0.092,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Reforming and alkylation"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.23 (BAT)","page":null,"quote":"Reforming and alkylation 0.377 0.092"}},{"id":"f9f3d2af23d7da18","parameter":"Phenolic compounds (4AAP)","value":"0.35","value_num":0.35,"unit":"kilograms per 1,000 m³ of flow","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BAT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the permit writer times the …"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.23 (BAT)","page":null,"quote":"Phenolic compounds (4AAP) 0.35 0.17"}},{"id":"79357b2f64b14276","parameter":"Phenolic compounds (4AAP)","value":"0.17","value_num":0.17,"unit":"kilograms per 1,000 m³ of flow","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BAT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the permit writer times the …"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.23 (BAT)","page":null,"quote":"Phenolic compounds (4AAP) 0.35 0.17"}},{"id":"dd2c42b4ed3ceddf","parameter":"Phenolic compounds","value":"0.119","value_num":0.119,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","new sources (NSPS)","(a) Any new source subject to this subpart must achieve the following new source performance standards (NSPS):"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.26 (NSPS)","page":null,"quote":"Phenolic compounds 0.119 0.058"}},{"id":"0866638ab0a8d115","parameter":"Phenolic compounds","value":"0.058","value_num":0.058,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","new sources (NSPS)","(a) Any new source subject to this subpart must achieve the following new source performance standards (NSPS):"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.26 (NSPS)","page":null,"quote":"Phenolic compounds 0.119 0.058"}},{"id":"614859e62c7c1474","parameter":"Phenolic compounds (4AAP)","value":"0.35","value_num":0.35,"unit":"kilograms per 1,000 m³ of flow","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart C—Petrochemical Subcategory","existing sources (BPT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by th…"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.32 (BPT)","page":null,"quote":"Phenolic compounds (4AAP) 0.35 0.17"}},{"id":"ea6c00bff542ca62","parameter":"Phenolic compounds (4AAP)","value":"0.17","value_num":0.17,"unit":"kilograms per 1,000 m³ of flow","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart C—Petrochemical Subcategory","existing sources (BPT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by th…"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.32 (BPT)","page":null,"quote":"Phenolic compounds (4AAP) 0.35 0.17"}},{"id":"b81f71c0be34e965","parameter":"Phenolic compounds (4AAP)","value":"0.037","value_num":0.037,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart C—Petrochemical Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Crude"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.33 (BAT)","page":null,"quote":"Crude 0.037 0.009"}},{"id":"ecc0f08ff5e38c4c","parameter":"Phenolic compounds (4AAP)","value":"0.009","value_num":0.009,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart C—Petrochemical Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Crude"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.33 (BAT)","page":null,"quote":"Crude 0.037 0.009"}},{"id":"73167eb040f1ca5d","parameter":"Phenolic compounds (4AAP)","value":"0.419","value_num":0.419,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart C—Petrochemical Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Cracking and coking"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.33 (BAT)","page":null,"quote":"Cracking and coking 0.419 0.102"}},{"id":"570cdd53dd3349be","parameter":"Phenolic compounds (4AAP)","value":"0.102","value_num":0.102,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart C—Petrochemical Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Cracking and coking"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.33 (BAT)","page":null,"quote":"Cracking and coking 0.419 0.102"}},{"id":"217db6376acc4e49","parameter":"Phenolic compounds (4AAP)","value":"0.226","value_num":0.226,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart C—Petrochemical Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Asphalt"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.33 (BAT)","page":null,"quote":"Asphalt 0.226 0.055"}},{"id":"7d2f32836dd88598","parameter":"Phenolic compounds (4AAP)","value":"0.055","value_num":0.055,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart C—Petrochemical Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Asphalt"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.33 (BAT)","page":null,"quote":"Asphalt 0.226 0.055"}},{"id":"36875df51ae0a1b1","parameter":"Phenolic compounds (4AAP)","value":"1.055","value_num":1.055,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart C—Petrochemical Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Lube"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.33 (BAT)","page":null,"quote":"Lube 1.055 0.257"}},{"id":"4a2d1204994f6166","parameter":"Phenolic compounds (4AAP)","value":"0.257","value_num":0.257,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart C—Petrochemical Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Lube"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.33 (BAT)","page":null,"quote":"Lube 1.055 0.257"}},{"id":"5758fef1c544900f","parameter":"Phenolic compounds (4AAP)","value":"0.377","value_num":0.377,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart C—Petrochemical Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Reforming and alkylation"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.33 (BAT)","page":null,"quote":"Reforming and alkylation 0.377 0.092"}},{"id":"2b621f6d0007d303","parameter":"Phenolic compounds (4AAP)","value":"0.092","value_num":0.092,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart C—Petrochemical Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Reforming and alkylation"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.33 (BAT)","page":null,"quote":"Reforming and alkylation 0.377 0.092"}},{"id":"2b55eec33d7e21ad","parameter":"Phenolic compounds (4AAP)","value":"0.35","value_num":0.35,"unit":"kilograms per 1,000 m³ of flow","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart C—Petrochemical Subcategory","existing sources (BAT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the permit writer times the …"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.33 (BAT)","page":null,"quote":"Phenolic compounds (4AAP) 0.35 0.17"}},{"id":"ed360637b8aca90e","parameter":"Phenolic compounds (4AAP)","value":"0.17","value_num":0.17,"unit":"kilograms per 1,000 m³ of flow","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:phenolic compounds","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart C—Petrochemical Subcategory","existing sources (BAT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the permit writer times the …"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 419.33 (BAT)","page":null,"quote":"Phenolic compounds (4AAP) 0.35 0.17"}}],"next":[{"tool":"check_values","says":"Has your user measured this? check_values sets each of their results beside every row held here, with a verdict and the row's cite.","arguments":{"place":"US-NE"},"needs":{"rows":"Your user's measured results, as their table prints them: [{parameter: \"phenolic compounds 4aap\", value, unit}, ...], any other parameters too."},"post":"/api/v1/check"},{"tool":"read_certificate","says":"Has your user a laboratory certificate? read_certificate reads every row it prints, each with its page, and checks them against these limits.","arguments":{"place":"US-NE"},"needs":{"content_base64":"The laboratory's certificate (PDF) or its XLSX, XLS or CSV export, as base64; or file_url, a public https address of it."},"post":"/api/v1/certificate"}]}