{"query":{"parameter":"phenanthrene","place":"US-PA","medium":null,"statistic":null,"kind":null},"searched":{"places":["US-PA","US"],"parameter_keys":["cas:85-01-8","cas:203-64-5","name:benzo[c]phenanthrene","name:polycyclic aromatic hydrocarbons, total of ten (acenaphthylene, benzo(a)anthracene, benzo(a)pyrene, benzo(b)fluoranthene, benzo(ghi)perylene, benzo(k)fluoranthene, chrysene, dibenzo(a,h)anthracene, indeno(1,2,3-cd)pyrene, phenanthrene)"],"names_matched":[["phenanthrene","cas:85-01-8"],["4h cyclopenta def phenanthrene","cas:203-64-5"],["benzo c phenanthrene","name:benzo[c]phenanthrene"],["cyclopenta d e f phenanthrene","cas:203-64-5"],["polycyclic aromatic hydrocarbons total of ten acenaphthylene benzo a anthracene benzo a pyrene benzo b fluoranthene benzo ghi perylene benzo k fluoranthene chrysene dibenzo a h anthracene indeno 1 2 3 cd pyrene phenanthrene","name:polycyclic aromatic hydrocarbons, total of ten (acenaphthylene, benzo(a)anthracene, benzo(a)pyrene, benzo(b)fluoranthene, benzo(ghi)perylene, benzo(k)fluoranthene, chrysene, dibenzo(a,h)anthracene, indeno(1,2,3-cd)pyrene, phenanthrene)"]],"match":"exact+contains","order":"The place's own instruments first, then each place above it, each in its register's order"},"total":38,"offset":0,"returned":38,"next_offset":null,"rows":[{"id":"fe06fd271db7f1e8","parameter":"PHENANTHRENE","value":"1100","value_num":1100,"unit":"µg/L","direction":"max","kind":"guideline","medium":"groundwater","level":"regional","parameter_key":"cas:85-01-8","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","groundwater in an aquifer used or currently planned to be used for drinking water or agriculture, total dissolved solids 2,500 mg/L or less (25 Pa. Code §250.304(c))","residential standard"],"cite":{"instrument":"us_pa_act2_gw","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for groundwater, Appendix A Tables 1-2, as DEP publishes them, with the 2024 PFAS MSCs","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 1 November 2021, Table 2 November 2023; the PFAS MSCs effective June 25, 2024 (DEP, updated 7/10/2024); DEP's bromobenzene correction as its Statewide Health Standards page states it on 2026-10-15","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%201.pdf","source_sha256":"5bc985b6f8b3595b0684a060dbc14d170987bbc89a70737370e1887c3932b13c","fetched_at":"2026-10-15","section":"25 Pa. Code ch. 250 Appendix A, Table 1 - Medium-Specific Concentrations (MSCs) for Organic Regulated Substances in Groundwater (used aquifer, TDS ≤ 2500, R)","page":9,"quote":null}},{"id":"ebf614b6618adc18","parameter":"PHENANTHRENE","value":"1100","value_num":1100,"unit":"µg/L","direction":"max","kind":"guideline","medium":"groundwater","level":"regional","parameter_key":"cas:85-01-8","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","groundwater in an aquifer used or currently planned to be used for drinking water or agriculture, total dissolved solids 2,500 mg/L or less (25 Pa. Code §250.304(c))","nonresidential standard"],"cite":{"instrument":"us_pa_act2_gw","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for groundwater, Appendix A Tables 1-2, as DEP publishes them, with the 2024 PFAS MSCs","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 1 November 2021, Table 2 November 2023; the PFAS MSCs effective June 25, 2024 (DEP, updated 7/10/2024); DEP's bromobenzene correction as its Statewide Health Standards page states it on 2026-10-15","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%201.pdf","source_sha256":"5bc985b6f8b3595b0684a060dbc14d170987bbc89a70737370e1887c3932b13c","fetched_at":"2026-10-15","section":"25 Pa. Code ch. 250 Appendix A, Table 1 - Medium-Specific Concentrations (MSCs) for Organic Regulated Substances in Groundwater (used aquifer, TDS ≤ 2500, NR)","page":9,"quote":null}},{"id":"2d8e23e6f1d668b6","parameter":"PHENANTHRENE","value":"1100","value_num":1100,"unit":"µg/L","direction":"max","kind":"guideline","medium":"groundwater","level":"regional","parameter_key":"cas:85-01-8","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","groundwater in an aquifer used or currently planned to be used whose naturally occurring background total dissolved solids exceed 2,500 mg/L (§250.304(e))","residential standard"],"cite":{"instrument":"us_pa_act2_gw","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for groundwater, Appendix A Tables 1-2, as DEP publishes them, with the 2024 PFAS MSCs","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 1 November 2021, Table 2 November 2023; the PFAS MSCs effective June 25, 2024 (DEP, updated 7/10/2024); DEP's bromobenzene correction as its Statewide Health Standards page states it on 2026-10-15","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%201.pdf","source_sha256":"5bc985b6f8b3595b0684a060dbc14d170987bbc89a70737370e1887c3932b13c","fetched_at":"2026-10-15","section":"25 Pa. Code ch. 250 Appendix A, Table 1 - Medium-Specific Concentrations (MSCs) for Organic Regulated Substances in Groundwater (used aquifer, TDS > 2500, R)","page":9,"quote":null}},{"id":"bc8198a97ac6089f","parameter":"PHENANTHRENE","value":"1100","value_num":1100,"unit":"µg/L","direction":"max","kind":"guideline","medium":"groundwater","level":"regional","parameter_key":"cas:85-01-8","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","groundwater in an aquifer used or currently planned to be used whose naturally occurring background total dissolved solids exceed 2,500 mg/L (§250.304(e))","nonresidential standard"],"cite":{"instrument":"us_pa_act2_gw","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for groundwater, Appendix A Tables 1-2, as DEP publishes them, with the 2024 PFAS MSCs","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 1 November 2021, Table 2 November 2023; the PFAS MSCs effective June 25, 2024 (DEP, updated 7/10/2024); DEP's bromobenzene correction as its Statewide Health Standards page states it on 2026-10-15","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%201.pdf","source_sha256":"5bc985b6f8b3595b0684a060dbc14d170987bbc89a70737370e1887c3932b13c","fetched_at":"2026-10-15","section":"25 Pa. Code ch. 250 Appendix A, Table 1 - Medium-Specific Concentrations (MSCs) for Organic Regulated Substances in Groundwater (used aquifer, TDS > 2500, NR)","page":9,"quote":null}},{"id":"386f79ce9c44d683","parameter":"PHENANTHRENE","value":"1100","value_num":1100,"unit":"µg/L","direction":"max","kind":"guideline","medium":"groundwater","level":"regional","parameter_key":"cas:85-01-8","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","groundwater in an aquifer not used or currently planned to be used (§250.304(d))","residential standard"],"cite":{"instrument":"us_pa_act2_gw","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for groundwater, Appendix A Tables 1-2, as DEP publishes them, with the 2024 PFAS MSCs","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 1 November 2021, Table 2 November 2023; the PFAS MSCs effective June 25, 2024 (DEP, updated 7/10/2024); DEP's bromobenzene correction as its Statewide Health Standards page states it on 2026-10-15","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%201.pdf","source_sha256":"5bc985b6f8b3595b0684a060dbc14d170987bbc89a70737370e1887c3932b13c","fetched_at":"2026-10-15","section":"25 Pa. Code ch. 250 Appendix A, Table 1 - Medium-Specific Concentrations (MSCs) for Organic Regulated Substances in Groundwater (nonuse aquifer, R)","page":9,"quote":null}},{"id":"9059d2d095db5f84","parameter":"PHENANTHRENE","value":"1100","value_num":1100,"unit":"µg/L","direction":"max","kind":"guideline","medium":"groundwater","level":"regional","parameter_key":"cas:85-01-8","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","groundwater in an aquifer not used or currently planned to be used (§250.304(d))","nonresidential standard"],"cite":{"instrument":"us_pa_act2_gw","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for groundwater, Appendix A Tables 1-2, as DEP publishes them, with the 2024 PFAS MSCs","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 1 November 2021, Table 2 November 2023; the PFAS MSCs effective June 25, 2024 (DEP, updated 7/10/2024); DEP's bromobenzene correction as its Statewide Health Standards page states it on 2026-10-15","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%201.pdf","source_sha256":"5bc985b6f8b3595b0684a060dbc14d170987bbc89a70737370e1887c3932b13c","fetched_at":"2026-10-15","section":"25 Pa. Code ch. 250 Appendix A, Table 1 - Medium-Specific Concentrations (MSCs) for Organic Regulated Substances in Groundwater (nonuse aquifer, NR)","page":9,"quote":null}},{"id":"3edbb2fec36b756b","parameter":"PHENANTHRENE","value":"66000","value_num":66000,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:85-01-8","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a direct contact numeric value: the soil MSC is the lowest of it and the soil-to-groundwater numeric value, or it with a soil buffer or equivalency demonstration (§250.305(c)-(e))","residential, soil 0-15 feet from the existing ground surface (§250.305(c))"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","section":"25 Pa. Code ch. 250 Appendix A, Table 3 - MSCs for Organic Regulated Substances in Soil, A. Direct Contact Numeric Values (R)","page":5,"quote":null}},{"id":"5e63e673efe4a917","parameter":"PHENANTHRENE","value":"190000","value_num":190000,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:85-01-8","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a direct contact numeric value: the soil MSC is the lowest of it and the soil-to-groundwater numeric value, or it with a soil buffer or equivalency demonstration (§250.305(c)-(e))","nonresidential, surface soil 0-2 feet (§250.305(d))"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","section":"25 Pa. Code ch. 250 Appendix A, Table 3 - MSCs for Organic Regulated Substances in Soil, A. Direct Contact Numeric Values (NR 0-2 ft)","page":5,"quote":null}},{"id":"f1f5fab11ec91d29","parameter":"PHENANTHRENE","value":"190000","value_num":190000,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:85-01-8","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a direct contact numeric value: the soil MSC is the lowest of it and the soil-to-groundwater numeric value, or it with a soil buffer or equivalency demonstration (§250.305(c)-(e))","nonresidential, subsurface soil 2-15 feet (§250.305(e))"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","section":"25 Pa. Code ch. 250 Appendix A, Table 3 - MSCs for Organic Regulated Substances in Soil, A. Direct Contact Numeric Values (NR 2-15 ft)","page":5,"quote":null}},{"id":"ade3dbc060d534d2","parameter":"PHENANTHRENE","value":"110","value_num":110,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:85-01-8","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))","the option 100 times the applicable groundwater MSC, expressed as mg/kg (§250.308(a)(1))","groundwater in an aquifer used or currently planned to be used for drinking water or agriculture, total dissolved solids 2,500 mg/L or less (25 Pa. Code §250.304(c))","residential standard"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","section":"25 Pa. Code ch. 250 Appendix A, Table 3 - MSCs for Organic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (used aquifer, TDS ≤ 2500, R, 100 X GW MSC)","page":7,"quote":null}},{"id":"3e07bd5da752796a","parameter":"PHENANTHRENE","value":"10000E","value_num":10000,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:85-01-8","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))","the generic value of the soil-to-groundwater equation, for soil not in the zone of groundwater saturation; in that zone the value is one tenth of it (§250.308(a)(2)-(4))","groundwater in an aquifer used or currently planned to be used for drinking water or agriculture, total dissolved solids 2,500 mg/L or less (25 Pa. Code §250.304(c))","residential standard"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","section":"25 Pa. Code ch. 250 Appendix A, Table 3 - MSCs for Organic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (used aquifer, TDS ≤ 2500, R, Generic Value)","page":7,"quote":null}},{"id":"296cb142db02ecea","parameter":"PHENANTHRENE","value":"110","value_num":110,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:85-01-8","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))","the option 100 times the applicable groundwater MSC, expressed as mg/kg (§250.308(a)(1))","groundwater in an aquifer used or currently planned to be used for drinking water or agriculture, total dissolved solids 2,500 mg/L or less (25 Pa. Code §250.304(c))","nonresidential standard"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","section":"25 Pa. Code ch. 250 Appendix A, Table 3 - MSCs for Organic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (used aquifer, TDS ≤ 2500, NR, 100 X GW MSC)","page":7,"quote":null}},{"id":"b1f98afa86007ffd","parameter":"PHENANTHRENE","value":"10000E","value_num":10000,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:85-01-8","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))","the generic value of the soil-to-groundwater equation, for soil not in the zone of groundwater saturation; in that zone the value is one tenth of it (§250.308(a)(2)-(4))","groundwater in an aquifer used or currently planned to be used for drinking water or agriculture, total dissolved solids 2,500 mg/L or less (25 Pa. Code §250.304(c))","nonresidential standard"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","section":"25 Pa. Code ch. 250 Appendix A, Table 3 - MSCs for Organic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (used aquifer, TDS ≤ 2500, NR, Generic Value)","page":7,"quote":null}},{"id":"f2fa306eec8e3389","parameter":"PHENANTHRENE","value":"110","value_num":110,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:85-01-8","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))","the option 100 times the applicable groundwater MSC, expressed as mg/kg (§250.308(a)(1))","groundwater in an aquifer used or currently planned to be used whose naturally occurring background total dissolved solids exceed 2,500 mg/L (§250.304(e))","residential standard"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","section":"25 Pa. Code ch. 250 Appendix A, Table 3 - MSCs for Organic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (used aquifer, TDS > 2500, R, 100 X GW MSC)","page":7,"quote":null}},{"id":"9c8d3834a03d5e46","parameter":"PHENANTHRENE","value":"10000E","value_num":10000,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:85-01-8","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))","the generic value of the soil-to-groundwater equation, for soil not in the zone of groundwater saturation; in that zone the value is one tenth of it (§250.308(a)(2)-(4))","groundwater in an aquifer used or currently planned to be used whose naturally occurring background total dissolved solids exceed 2,500 mg/L (§250.304(e))","residential standard"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","section":"25 Pa. Code ch. 250 Appendix A, Table 3 - MSCs for Organic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (used aquifer, TDS > 2500, R, Generic Value)","page":7,"quote":null}},{"id":"d2e47512712c54e2","parameter":"PHENANTHRENE","value":"110","value_num":110,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:85-01-8","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))","the option 100 times the applicable groundwater MSC, expressed as mg/kg (§250.308(a)(1))","groundwater in an aquifer used or currently planned to be used whose naturally occurring background total dissolved solids exceed 2,500 mg/L (§250.304(e))","nonresidential standard"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","section":"25 Pa. Code ch. 250 Appendix A, Table 3 - MSCs for Organic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (used aquifer, TDS > 2500, NR, 100 X GW MSC)","page":7,"quote":null}},{"id":"60394ab4425c8b0d","parameter":"PHENANTHRENE","value":"10000E","value_num":10000,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:85-01-8","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))","the generic value of the soil-to-groundwater equation, for soil not in the zone of groundwater saturation; in that zone the value is one tenth of it (§250.308(a)(2)-(4))","groundwater in an aquifer used or currently planned to be used whose naturally occurring background total dissolved solids exceed 2,500 mg/L (§250.304(e))","nonresidential standard"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","section":"25 Pa. Code ch. 250 Appendix A, Table 3 - MSCs for Organic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (used aquifer, TDS > 2500, NR, Generic Value)","page":7,"quote":null}},{"id":"c50d572e95c0bd9a","parameter":"PHENANTHRENE","value":"110","value_num":110,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:85-01-8","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))","the option 100 times the applicable groundwater MSC, expressed as mg/kg (§250.308(a)(1))","groundwater in an aquifer not used or currently planned to be used (§250.304(d))","residential standard"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","section":"25 Pa. Code ch. 250 Appendix A, Table 3 - MSCs for Organic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (nonuse aquifer, R, 100 X GW MSC)","page":7,"quote":null}},{"id":"538e6c1f4998e10d","parameter":"PHENANTHRENE","value":"10000E","value_num":10000,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:85-01-8","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))","the generic value of the soil-to-groundwater equation, for soil not in the zone of groundwater saturation; in that zone the value is one tenth of it (§250.308(a)(2)-(4))","groundwater in an aquifer not used or currently planned to be used (§250.304(d))","residential standard"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","section":"25 Pa. Code ch. 250 Appendix A, Table 3 - MSCs for Organic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (nonuse aquifer, R, Generic Value)","page":7,"quote":null}},{"id":"fa645c8e8f292cca","parameter":"PHENANTHRENE","value":"110","value_num":110,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:85-01-8","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))","the option 100 times the applicable groundwater MSC, expressed as mg/kg (§250.308(a)(1))","groundwater in an aquifer not used or currently planned to be used (§250.304(d))","nonresidential standard"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","section":"25 Pa. Code ch. 250 Appendix A, Table 3 - MSCs for Organic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (nonuse aquifer, NR, 100 X GW MSC)","page":7,"quote":null}},{"id":"d197e0fdc177c610","parameter":"PHENANTHRENE","value":"10000E","value_num":10000,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:85-01-8","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))","the generic value of the soil-to-groundwater equation, for soil not in the zone of groundwater saturation; in that zone the value is one tenth of it (§250.308(a)(2)-(4))","groundwater in an aquifer not used or currently planned to be used (§250.304(d))","nonresidential standard"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","section":"25 Pa. Code ch. 250 Appendix A, Table 3 - MSCs for Organic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (nonuse aquifer, NR, Generic Value)","page":7,"quote":null}},{"id":"ff1132807994961f","parameter":"PHENANTHRENE","value":"1","value_num":1,"unit":"µg/L","statistic":"four_day_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:85-01-8","place":["US-PA"],"conditions":[],"cite":{"instrument":"us_pa_wqs","title":"25 Pa. Code §93.8c Table 5 (water quality criteria for toxic substances) and §93.7 Table 3 (specific water quality criteria) — Pennsylvania","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection)","edition":"Pennsylvania Code as served 2026-10-09: §93.8c amended December 19, 2025, effective December 20, 2025, 55 Pa.B. 8596; §93.7 rows name their own page","source_url":"https://www.pacodeandbulletin.gov/Display/pacode?file=/secure/pacode/data/025/chapter93/s93.8c.html","source_sha256":"9f8f9a0d4da400c55be6373f6a6482b24c4fab5c9a4d0c445f3f55c33a799beb","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"25 Pa. Code §93.8c Table 5 (criteria continuous concentration (CCC))","page":null,"quote":"44B PHENANTHRENE 85018 1 5 N/A -"}},{"id":"6bd5a3e0c3ad73f0","parameter":"PHENANTHRENE","value":"5","value_num":5,"unit":"µg/L","statistic":"hourly_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:85-01-8","place":["US-PA"],"conditions":[],"cite":{"instrument":"us_pa_wqs","title":"25 Pa. Code §93.8c Table 5 (water quality criteria for toxic substances) and §93.7 Table 3 (specific water quality criteria) — Pennsylvania","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection)","edition":"Pennsylvania Code as served 2026-10-09: §93.8c amended December 19, 2025, effective December 20, 2025, 55 Pa.B. 8596; §93.7 rows name their own page","source_url":"https://www.pacodeandbulletin.gov/Display/pacode?file=/secure/pacode/data/025/chapter93/s93.8c.html","source_sha256":"9f8f9a0d4da400c55be6373f6a6482b24c4fab5c9a4d0c445f3f55c33a799beb","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"25 Pa. Code §93.8c Table 5 (criteria maximum concentration (CMC))","page":null,"quote":"44B PHENANTHRENE 85018 1 5 N/A -"}},{"id":"951d2049707cb585","parameter":"Phenanthrene","value":"0.059","value_num":0.059,"unit":"mg/L","statistic":"composite","direction":"max","kind":"limit","medium":"product","level":"national","parameter_key":"cas:85-01-8","place":["US"],"conditions":["(a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS."],"cite":{"instrument":"us_40cfr268_48","title":"40 CFR 268.48 — Universal treatment standards: Table UTS, wastewater and nonwastewater treatment standards for the hazardous constituents of land-disposal-restricted wastes","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"eCFR, 40 CFR 268.48 as of 2026-10-13 (title 40 up to date as of that day; source note: 59 FR 48103, Sept. 19, 1994, as last amended at 76 FR 34156, June 13, 2011)","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-13/title-40.xml?part=268&section=268.48","source_sha256":"70b2e58a6b1e228e2c204acc69b69fab0d5a0347e35d569959073c3dc3ee4adb","fetched_at":"2026-10-15","section":"40 CFR 268.48, Table UTS, Organic Constituents, wastewater standard","page":null,"quote":"Phenanthrene 85-01-8 0.059 5.6"}},{"id":"33a835e7fa5abdce","parameter":"Phenanthrene","value":"5.6","value_num":5.6,"unit":"mg/kg","statistic":"instant","direction":"max","kind":"limit","medium":"product","level":"national","parameter_key":"cas:85-01-8","place":["US"],"conditions":["(a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS."],"cite":{"instrument":"us_40cfr268_48","title":"40 CFR 268.48 — Universal treatment standards: Table UTS, wastewater and nonwastewater treatment standards for the hazardous constituents of land-disposal-restricted wastes","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"eCFR, 40 CFR 268.48 as of 2026-10-13 (title 40 up to date as of that day; source note: 59 FR 48103, Sept. 19, 1994, as last amended at 76 FR 34156, June 13, 2011)","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-13/title-40.xml?part=268&section=268.48","source_sha256":"70b2e58a6b1e228e2c204acc69b69fab0d5a0347e35d569959073c3dc3ee4adb","fetched_at":"2026-10-15","section":"40 CFR 268.48, Table UTS, Organic Constituents, nonwastewater standard","page":null,"quote":"Phenanthrene 85-01-8 0.059 5.6"}},{"id":"da906d7667085dfb","parameter":"Phenanthrene","value":"59","value_num":59,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:85-01-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment","existing sources (BAT)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.91 (BAT)","page":null,"quote":"Phenanthrene 59 22"}},{"id":"3733bbd40ac1830e","parameter":"Phenanthrene","value":"59","value_num":59,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:85-01-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment","new sources (NSPS)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.91 (NSPS)","page":null,"quote":"Phenanthrene 59 22"}},{"id":"f64d8edfb552beac","parameter":"Phenanthrene","value":"22","value_num":22,"unit":"µg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:85-01-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment","existing sources (BAT)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.91 (BAT)","page":null,"quote":"Phenanthrene 59 22"}},{"id":"a64b6bb0aedcb1ed","parameter":"Phenanthrene","value":"22","value_num":22,"unit":"µg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:85-01-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment","new sources (NSPS)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.91 (NSPS)","page":null,"quote":"Phenanthrene 59 22"}},{"id":"ed0b5d7c1cea51c5","parameter":"Phenanthrene","value":"47","value_num":47,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:85-01-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment","existing sources (BAT)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.101 (BAT)","page":null,"quote":"Phenanthrene 47 19"}},{"id":"f95f5db16280a73a","parameter":"Phenanthrene","value":"47","value_num":47,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:85-01-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment","new sources (NSPS)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.101 (NSPS)","page":null,"quote":"Phenanthrene 47 19"}},{"id":"20be2e5e45a50418","parameter":"Phenanthrene","value":"19","value_num":19,"unit":"µg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:85-01-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment","existing sources (BAT)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.101 (BAT)","page":null,"quote":"Phenanthrene 47 19"}},{"id":"262f5ba1a86a184b","parameter":"Phenanthrene","value":"19","value_num":19,"unit":"µg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:85-01-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment","new sources (NSPS)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.101 (NSPS)","page":null,"quote":"Phenanthrene 47 19"}},{"id":"5d52f229ead5597f","parameter":"Phenanthrene","value":"47","value_num":47,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:85-01-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is sewer","cites is 40 CFR 414","the discharge is of the Subpart K—Indirect Discharge Point Sources","new sources (PSNS)","(b) In the case of lead, zinc, and total cyanide the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for metals and times the flow from the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste streams are defined…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.111 (PSNS)","page":null,"quote":"Phenanthrene 47 19"}},{"id":"fc03959e1d7cc266","parameter":"Phenanthrene","value":"19","value_num":19,"unit":"µg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:85-01-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is sewer","cites is 40 CFR 414","the discharge is of the Subpart K—Indirect Discharge Point Sources","new sources (PSNS)","(b) In the case of lead, zinc, and total cyanide the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for metals and times the flow from the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste streams are defined…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.111 (PSNS)","page":null,"quote":"Phenanthrene 47 19"}},{"id":"d6b28f3da7f821bd","parameter":"Phenanthrene","value":"0.34","value_num":0.34,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:85-01-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 442","the discharge is of the Subpart B—Rail Tank Cars Transporting Chemical and Petroleum Cargos","existing sources (BPT)","table: Table—Effluent Limitations"],"cite":{"instrument":"us_40cfr442","title":"40 CFR Part 442 — PART 442—TRANSPORTATION EQUIPMENT CLEANING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=442","source_sha256":"9330b2255a5f7e74daf9175af898d9d28ae855a2560f50658d1bce4c6b8feded","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 442.21 (BPT)","page":null,"quote":"Phenanthrene 0.34"}},{"id":"d552dfcd765e4119","parameter":"Phenanthrene","value":"0.34","value_num":0.34,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:85-01-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 442","the discharge is of the Subpart B—Rail Tank Cars Transporting Chemical and Petroleum Cargos","existing sources (PSES)","table: Table—Pretreatment Standards'"],"cite":{"instrument":"us_40cfr442","title":"40 CFR Part 442 — PART 442—TRANSPORTATION EQUIPMENT CLEANING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=442","source_sha256":"9330b2255a5f7e74daf9175af898d9d28ae855a2560f50658d1bce4c6b8feded","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 442.25 (PSES)","page":null,"quote":"Phenanthrene 0.34"}},{"id":"ac79bdc949bb5944","parameter":"Phenanthrene","value":"0.34","value_num":0.34,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:85-01-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 442","the discharge is of the Subpart B—Rail Tank Cars Transporting Chemical and Petroleum Cargos","new sources (PSNS)","table: Table—Pretreatment Standards"],"cite":{"instrument":"us_40cfr442","title":"40 CFR Part 442 — PART 442—TRANSPORTATION EQUIPMENT CLEANING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=442","source_sha256":"9330b2255a5f7e74daf9175af898d9d28ae855a2560f50658d1bce4c6b8feded","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 442.26 (PSNS)","page":null,"quote":"Phenanthrene 0.34"}}],"next":[{"tool":"check_values","says":"Has your user measured this? check_values sets each of their results beside every row held here, with a verdict and the row's cite.","arguments":{"place":"US-PA"},"needs":{"rows":"Your user's measured results, as their table prints them: [{parameter: \"phenanthrene\", value, unit}, ...], any other parameters too."},"post":"/api/v1/check"},{"tool":"read_certificate","says":"Has your user a laboratory certificate? read_certificate reads every row it prints, each with its page, and checks them against these limits.","arguments":{"place":"US-PA"},"needs":{"content_base64":"The laboratory's certificate (PDF) or its XLSX, XLS or CSV export, as base64; or file_url, a public https address of it."},"post":"/api/v1/certificate"}]}