{"query":{"parameter":"phenanthrene","place":"US-ME","medium":null,"statistic":null,"kind":null},"searched":{"places":["US-ME","US"],"parameter_keys":["cas:85-01-8","cas:203-64-5","name:benzo[c]phenanthrene","name:polycyclic aromatic hydrocarbons, total of ten (acenaphthylene, benzo(a)anthracene, benzo(a)pyrene, benzo(b)fluoranthene, benzo(ghi)perylene, benzo(k)fluoranthene, chrysene, dibenzo(a,h)anthracene, indeno(1,2,3-cd)pyrene, phenanthrene)"],"names_matched":[["phenanthrene","cas:85-01-8"],["4h cyclopenta def phenanthrene","cas:203-64-5"],["benzo c phenanthrene","name:benzo[c]phenanthrene"],["cyclopenta d e f phenanthrene","cas:203-64-5"],["polycyclic aromatic hydrocarbons total of ten acenaphthylene benzo a anthracene benzo a pyrene benzo b fluoranthene benzo ghi perylene benzo k fluoranthene chrysene dibenzo a h anthracene indeno 1 2 3 cd pyrene phenanthrene","name:polycyclic aromatic hydrocarbons, total of ten (acenaphthylene, benzo(a)anthracene, benzo(a)pyrene, benzo(b)fluoranthene, benzo(ghi)perylene, benzo(k)fluoranthene, chrysene, dibenzo(a,h)anthracene, indeno(1,2,3-cd)pyrene, phenanthrene)"]],"match":"exact+contains","order":"The place's own instruments first, then each place above it, each in its register's order"},"total":15,"offset":0,"returned":15,"next_offset":null,"rows":[{"id":"951d2049707cb585","parameter":"Phenanthrene","value":"0.059","value_num":0.059,"unit":"mg/L","statistic":"composite","direction":"max","kind":"limit","medium":"product","level":"national","parameter_key":"cas:85-01-8","place":["US"],"conditions":["(a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS."],"cite":{"instrument":"us_40cfr268_48","title":"40 CFR 268.48 — Universal treatment standards: Table UTS, wastewater and nonwastewater treatment standards for the hazardous constituents of land-disposal-restricted wastes","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"eCFR, 40 CFR 268.48 as of 2026-10-13 (title 40 up to date as of that day; source note: 59 FR 48103, Sept. 19, 1994, as last amended at 76 FR 34156, June 13, 2011)","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-13/title-40.xml?part=268&section=268.48","source_sha256":"70b2e58a6b1e228e2c204acc69b69fab0d5a0347e35d569959073c3dc3ee4adb","fetched_at":"2026-10-15","section":"40 CFR 268.48, Table UTS, Organic Constituents, wastewater standard","page":null,"quote":"Phenanthrene 85-01-8 0.059 5.6"}},{"id":"33a835e7fa5abdce","parameter":"Phenanthrene","value":"5.6","value_num":5.6,"unit":"mg/kg","statistic":"instant","direction":"max","kind":"limit","medium":"product","level":"national","parameter_key":"cas:85-01-8","place":["US"],"conditions":["(a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS."],"cite":{"instrument":"us_40cfr268_48","title":"40 CFR 268.48 — Universal treatment standards: Table UTS, wastewater and nonwastewater treatment standards for the hazardous constituents of land-disposal-restricted wastes","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"eCFR, 40 CFR 268.48 as of 2026-10-13 (title 40 up to date as of that day; source note: 59 FR 48103, Sept. 19, 1994, as last amended at 76 FR 34156, June 13, 2011)","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-13/title-40.xml?part=268&section=268.48","source_sha256":"70b2e58a6b1e228e2c204acc69b69fab0d5a0347e35d569959073c3dc3ee4adb","fetched_at":"2026-10-15","section":"40 CFR 268.48, Table UTS, Organic Constituents, nonwastewater standard","page":null,"quote":"Phenanthrene 85-01-8 0.059 5.6"}},{"id":"da906d7667085dfb","parameter":"Phenanthrene","value":"59","value_num":59,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:85-01-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment","existing sources (BAT)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.91 (BAT)","page":null,"quote":"Phenanthrene 59 22"}},{"id":"3733bbd40ac1830e","parameter":"Phenanthrene","value":"59","value_num":59,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:85-01-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment","new sources (NSPS)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.91 (NSPS)","page":null,"quote":"Phenanthrene 59 22"}},{"id":"f64d8edfb552beac","parameter":"Phenanthrene","value":"22","value_num":22,"unit":"µg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:85-01-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment","existing sources (BAT)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.91 (BAT)","page":null,"quote":"Phenanthrene 59 22"}},{"id":"a64b6bb0aedcb1ed","parameter":"Phenanthrene","value":"22","value_num":22,"unit":"µg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:85-01-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment","new sources (NSPS)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.91 (NSPS)","page":null,"quote":"Phenanthrene 59 22"}},{"id":"ed0b5d7c1cea51c5","parameter":"Phenanthrene","value":"47","value_num":47,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:85-01-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment","existing sources (BAT)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.101 (BAT)","page":null,"quote":"Phenanthrene 47 19"}},{"id":"f95f5db16280a73a","parameter":"Phenanthrene","value":"47","value_num":47,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:85-01-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment","new sources (NSPS)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.101 (NSPS)","page":null,"quote":"Phenanthrene 47 19"}},{"id":"20be2e5e45a50418","parameter":"Phenanthrene","value":"19","value_num":19,"unit":"µg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:85-01-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment","existing sources (BAT)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.101 (BAT)","page":null,"quote":"Phenanthrene 47 19"}},{"id":"262f5ba1a86a184b","parameter":"Phenanthrene","value":"19","value_num":19,"unit":"µg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:85-01-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment","new sources (NSPS)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.101 (NSPS)","page":null,"quote":"Phenanthrene 47 19"}},{"id":"5d52f229ead5597f","parameter":"Phenanthrene","value":"47","value_num":47,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:85-01-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is sewer","cites is 40 CFR 414","the discharge is of the Subpart K—Indirect Discharge Point Sources","new sources (PSNS)","(b) In the case of lead, zinc, and total cyanide the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for metals and times the flow from the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste streams are defined…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.111 (PSNS)","page":null,"quote":"Phenanthrene 47 19"}},{"id":"fc03959e1d7cc266","parameter":"Phenanthrene","value":"19","value_num":19,"unit":"µg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:85-01-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is sewer","cites is 40 CFR 414","the discharge is of the Subpart K—Indirect Discharge Point Sources","new sources (PSNS)","(b) In the case of lead, zinc, and total cyanide the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for metals and times the flow from the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste streams are defined…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.111 (PSNS)","page":null,"quote":"Phenanthrene 47 19"}},{"id":"d6b28f3da7f821bd","parameter":"Phenanthrene","value":"0.34","value_num":0.34,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:85-01-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 442","the discharge is of the Subpart B—Rail Tank Cars Transporting Chemical and Petroleum Cargos","existing sources (BPT)","table: Table—Effluent Limitations"],"cite":{"instrument":"us_40cfr442","title":"40 CFR Part 442 — PART 442—TRANSPORTATION EQUIPMENT CLEANING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=442","source_sha256":"9330b2255a5f7e74daf9175af898d9d28ae855a2560f50658d1bce4c6b8feded","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 442.21 (BPT)","page":null,"quote":"Phenanthrene 0.34"}},{"id":"d552dfcd765e4119","parameter":"Phenanthrene","value":"0.34","value_num":0.34,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:85-01-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 442","the discharge is of the Subpart B—Rail Tank Cars Transporting Chemical and Petroleum Cargos","existing sources (PSES)","table: Table—Pretreatment Standards'"],"cite":{"instrument":"us_40cfr442","title":"40 CFR Part 442 — PART 442—TRANSPORTATION EQUIPMENT CLEANING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=442","source_sha256":"9330b2255a5f7e74daf9175af898d9d28ae855a2560f50658d1bce4c6b8feded","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 442.25 (PSES)","page":null,"quote":"Phenanthrene 0.34"}},{"id":"ac79bdc949bb5944","parameter":"Phenanthrene","value":"0.34","value_num":0.34,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:85-01-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 442","the discharge is of the Subpart B—Rail Tank Cars Transporting Chemical and Petroleum Cargos","new sources (PSNS)","table: Table—Pretreatment Standards"],"cite":{"instrument":"us_40cfr442","title":"40 CFR Part 442 — PART 442—TRANSPORTATION EQUIPMENT CLEANING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=442","source_sha256":"9330b2255a5f7e74daf9175af898d9d28ae855a2560f50658d1bce4c6b8feded","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 442.26 (PSNS)","page":null,"quote":"Phenanthrene 0.34"}}],"next":[{"tool":"check_values","says":"Has your user measured this? check_values sets each of their results beside every row held here, with a verdict and the row's cite.","arguments":{"place":"US-ME"},"needs":{"rows":"Your user's measured results, as their table prints them: [{parameter: \"phenanthrene\", value, unit}, ...], any other parameters too."},"post":"/api/v1/check"},{"tool":"read_certificate","says":"Has your user a laboratory certificate? read_certificate reads every row it prints, each with its page, and checks them against these limits.","arguments":{"place":"US-ME"},"needs":{"content_base64":"The laboratory's certificate (PDF) or its XLSX, XLS or CSV export, as base64; or file_url, a public https address of it."},"post":"/api/v1/certificate"}]}