{"query":{"parameter":"parathion","place":"US-WI","medium":null,"statistic":null,"kind":null},"searched":{"places":["US-WI","US"],"parameter_keys":["cas:56-38-2","cas:298-00-0","name:parathion and methyl parathion"],"names_matched":[["parathion","cas:56-38-2"],["methyl parathion","cas:298-00-0"],["parathion and methyl parathion","name:parathion and methyl parathion"],["parathion methyl","cas:298-00-0"]],"match":"exact+contains","order":"The place's own instruments first, then each place above it, each in its register's order"},"total":16,"offset":0,"returned":16,"next_offset":null,"rows":[{"id":"d5b1806618fe6689","parameter":"Parathion","value":"0.057","value_num":0.057,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:56-38-2","place":["US-WI"],"conditions":["receiving_water is freshwater","cold water community (NR 102.04(3)(a))"],"cite":{"instrument":"us_wi_wqs","title":"Wisconsin Administrative Code ch. NR 105 surface water quality criteria for toxic substances (acute and chronic aquatic life, wildlife, human threshold and human cancer) and ch. NR 102 dissolved oxygen, pH, PFOS/PFOA and total phosphorus criteria","issuer":"State of Wisconsin, Department of Natural Resources","edition":"NR 105 as last amended Register July 2010 No. 655 (eff. 8-1-10) and NR 102 effective April 26, 2024 (Register January 2024 No. 817), as US EPA posts them in effect for CWA purposes; EPA disapproved NR 105's copper and nickel acute and chronic criteria (Tables 2 and 6) and the endrin chronic criterion (Table 5), replaced by 40 CFR 132 Tables 1 and 2","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/wiwqs-nr105.pdf","source_sha256":"c41f1ef79ba951936c9998711fca196f6e6b27dff311ba17b27d938b39cb0063","fetched_at":"2026-10-14","section":"NR 105.05 Table 1","page":9,"quote":"Parathion 0.057 0.057 0.057"}},{"id":"78858d2afd4fad95","parameter":"Parathion","value":"0.057","value_num":0.057,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:56-38-2","place":["US-WI"],"conditions":["receiving_water is freshwater","warm water sport fish community (NR 102.04(3)(b)) or warm water forage fish community (NR 102.04(3)(c)) or limited forage fish community (NR 102.04(3)(d))"],"cite":{"instrument":"us_wi_wqs","title":"Wisconsin Administrative Code ch. NR 105 surface water quality criteria for toxic substances (acute and chronic aquatic life, wildlife, human threshold and human cancer) and ch. NR 102 dissolved oxygen, pH, PFOS/PFOA and total phosphorus criteria","issuer":"State of Wisconsin, Department of Natural Resources","edition":"NR 105 as last amended Register July 2010 No. 655 (eff. 8-1-10) and NR 102 effective April 26, 2024 (Register January 2024 No. 817), as US EPA posts them in effect for CWA purposes; EPA disapproved NR 105's copper and nickel acute and chronic criteria (Tables 2 and 6) and the endrin chronic criterion (Table 5), replaced by 40 CFR 132 Tables 1 and 2","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/wiwqs-nr105.pdf","source_sha256":"c41f1ef79ba951936c9998711fca196f6e6b27dff311ba17b27d938b39cb0063","fetched_at":"2026-10-14","section":"NR 105.05 Table 1","page":9,"quote":"Parathion 0.057 0.057 0.057"}},{"id":"84fd70bae5d944df","parameter":"Parathion","value":"0.057","value_num":0.057,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:56-38-2","place":["US-WI"],"conditions":["receiving_water is freshwater","limited aquatic life (NR 102.04(3)(e))"],"cite":{"instrument":"us_wi_wqs","title":"Wisconsin Administrative Code ch. NR 105 surface water quality criteria for toxic substances (acute and chronic aquatic life, wildlife, human threshold and human cancer) and ch. NR 102 dissolved oxygen, pH, PFOS/PFOA and total phosphorus criteria","issuer":"State of Wisconsin, Department of Natural Resources","edition":"NR 105 as last amended Register July 2010 No. 655 (eff. 8-1-10) and NR 102 effective April 26, 2024 (Register January 2024 No. 817), as US EPA posts them in effect for CWA purposes; EPA disapproved NR 105's copper and nickel acute and chronic criteria (Tables 2 and 6) and the endrin chronic criterion (Table 5), replaced by 40 CFR 132 Tables 1 and 2","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/wiwqs-nr105.pdf","source_sha256":"c41f1ef79ba951936c9998711fca196f6e6b27dff311ba17b27d938b39cb0063","fetched_at":"2026-10-14","section":"NR 105.05 Table 1","page":9,"quote":"Parathion 0.057 0.057 0.057"}},{"id":"67f73e36aaecea6c","parameter":"Parathion","value":"0.011","value_num":0.011,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:56-38-2","place":["US-WI"],"conditions":["receiving_water is freshwater","cold water community (NR 102.04(3)(a))"],"cite":{"instrument":"us_wi_wqs","title":"Wisconsin Administrative Code ch. NR 105 surface water quality criteria for toxic substances (acute and chronic aquatic life, wildlife, human threshold and human cancer) and ch. NR 102 dissolved oxygen, pH, PFOS/PFOA and total phosphorus criteria","issuer":"State of Wisconsin, Department of Natural Resources","edition":"NR 105 as last amended Register July 2010 No. 655 (eff. 8-1-10) and NR 102 effective April 26, 2024 (Register January 2024 No. 817), as US EPA posts them in effect for CWA purposes; EPA disapproved NR 105's copper and nickel acute and chronic criteria (Tables 2 and 6) and the endrin chronic criterion (Table 5), replaced by 40 CFR 132 Tables 1 and 2","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/wiwqs-nr105.pdf","source_sha256":"c41f1ef79ba951936c9998711fca196f6e6b27dff311ba17b27d938b39cb0063","fetched_at":"2026-10-14","section":"NR 105.06 Table 5","page":12,"quote":"Parathion 0.011 0.011 0.011"}},{"id":"1a2c24bcf5cce9cf","parameter":"Parathion","value":"0.011","value_num":0.011,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:56-38-2","place":["US-WI"],"conditions":["receiving_water is freshwater","warm water sport fish community (NR 102.04(3)(b)) or warm water forage fish community (NR 102.04(3)(c))"],"cite":{"instrument":"us_wi_wqs","title":"Wisconsin Administrative Code ch. NR 105 surface water quality criteria for toxic substances (acute and chronic aquatic life, wildlife, human threshold and human cancer) and ch. NR 102 dissolved oxygen, pH, PFOS/PFOA and total phosphorus criteria","issuer":"State of Wisconsin, Department of Natural Resources","edition":"NR 105 as last amended Register July 2010 No. 655 (eff. 8-1-10) and NR 102 effective April 26, 2024 (Register January 2024 No. 817), as US EPA posts them in effect for CWA purposes; EPA disapproved NR 105's copper and nickel acute and chronic criteria (Tables 2 and 6) and the endrin chronic criterion (Table 5), replaced by 40 CFR 132 Tables 1 and 2","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/wiwqs-nr105.pdf","source_sha256":"c41f1ef79ba951936c9998711fca196f6e6b27dff311ba17b27d938b39cb0063","fetched_at":"2026-10-14","section":"NR 105.06 Table 5","page":12,"quote":"Parathion 0.011 0.011 0.011"}},{"id":"f1894bf3e8e5a299","parameter":"Parathion","value":"0.011","value_num":0.011,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:56-38-2","place":["US-WI"],"conditions":["receiving_water is freshwater","limited forage fish community (NR 102.04(3)(d)) or limited aquatic life (NR 102.04(3)(e))"],"cite":{"instrument":"us_wi_wqs","title":"Wisconsin Administrative Code ch. NR 105 surface water quality criteria for toxic substances (acute and chronic aquatic life, wildlife, human threshold and human cancer) and ch. NR 102 dissolved oxygen, pH, PFOS/PFOA and total phosphorus criteria","issuer":"State of Wisconsin, Department of Natural Resources","edition":"NR 105 as last amended Register July 2010 No. 655 (eff. 8-1-10) and NR 102 effective April 26, 2024 (Register January 2024 No. 817), as US EPA posts them in effect for CWA purposes; EPA disapproved NR 105's copper and nickel acute and chronic criteria (Tables 2 and 6) and the endrin chronic criterion (Table 5), replaced by 40 CFR 132 Tables 1 and 2","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/wiwqs-nr105.pdf","source_sha256":"c41f1ef79ba951936c9998711fca196f6e6b27dff311ba17b27d938b39cb0063","fetched_at":"2026-10-14","section":"NR 105.06 Table 5","page":12,"quote":"Parathion 0.011 0.011 0.011"}},{"id":"9159cb0c03457c9a","parameter":"Parathion","value":"0.065","value_num":0.065,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"national","parameter_key":"cas:56-38-2","place":["US"],"conditions":["EPA's recommendation under Clean Water Act § 304(a): 'State and Tribal governments may use these criteria or use them as guidance in developing their own' — it binds a water once the state adopts it for the water's designated use","receiving_water is freshwater","Freshwater CMC (acute): criterion maximum concentration, acute"],"cite":{"instrument":"us_nrwqc_aquatic","title":"EPA National Recommended Water Quality Criteria — Aquatic Life Criteria Table (freshwater and saltwater CMC/CCC)","issuer":"U.S. Environmental Protection Agency","edition":"EPA web table, last updated on June 9, 2026 (fetched 2026-10-09); each criterion carries its publication year","source_url":"https://www.epa.gov/wqc/national-recommended-water-quality-criteria-aquatic-life-criteria-table","source_sha256":"be6b429558db9852c3456eb22c17046aa1a3335ee89e702e8afb793f9b5b25ec","fetched_at":"2026-10-09","section":"National Recommended Aquatic Life Criteria table","page":null,"quote":"Parathion 56382 0.065 0.013 — — 1995"}},{"id":"9fb43bd4944a2fe6","parameter":"Parathion","value":"0.013","value_num":0.013,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"national","parameter_key":"cas:56-38-2","place":["US"],"conditions":["EPA's recommendation under Clean Water Act § 304(a): 'State and Tribal governments may use these criteria or use them as guidance in developing their own' — it binds a water once the state adopts it for the water's designated use","receiving_water is freshwater","Freshwater CCC (chronic): criterion continuous concentration, chronic"],"cite":{"instrument":"us_nrwqc_aquatic","title":"EPA National Recommended Water Quality Criteria — Aquatic Life Criteria Table (freshwater and saltwater CMC/CCC)","issuer":"U.S. Environmental Protection Agency","edition":"EPA web table, last updated on June 9, 2026 (fetched 2026-10-09); each criterion carries its publication year","source_url":"https://www.epa.gov/wqc/national-recommended-water-quality-criteria-aquatic-life-criteria-table","source_sha256":"be6b429558db9852c3456eb22c17046aa1a3335ee89e702e8afb793f9b5b25ec","fetched_at":"2026-10-09","section":"National Recommended Aquatic Life Criteria table","page":null,"quote":"Parathion 56382 0.065 0.013 — — 1995"}},{"id":"3d0e58093a85f406","parameter":"Parathion","value":"380","value_num":380,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"national","parameter_key":"cas:56-38-2","place":["US"],"conditions":["Resident Soil (mg/kg)"],"cite":{"instrument":"us_rsl_soil","title":"US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Soil","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"November 2024","source_url":"https://semspub.epa.gov/src/document/HQ/405270","source_sha256":"0160dc81b4f55d738a354a74de92488f149946ebfa7c6a6c64592f45348043d7","fetched_at":"2026-09-19","section":null,"page":null,"quote":null,"table":"sols","column":"residentiel"}},{"id":"ba56e6f9fc6eaac7","parameter":"Parathion","value":"4900","value_num":4900,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"national","parameter_key":"cas:56-38-2","place":["US"],"conditions":["Industrial Soil (mg/kg)"],"cite":{"instrument":"us_rsl_soil","title":"US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Soil","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"November 2024","source_url":"https://semspub.epa.gov/src/document/HQ/405270","source_sha256":"0160dc81b4f55d738a354a74de92488f149946ebfa7c6a6c64592f45348043d7","fetched_at":"2026-09-19","section":null,"page":null,"quote":null,"table":"sols","column":"industriel"}},{"id":"d608a5b15fadbcc9","parameter":"Parathion","value":"0.43","value_num":0.43,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"national","parameter_key":"cas:56-38-2","place":["US"],"conditions":["Protection of Groundwater SSLs: Risk-based SSL (mg/kg); SSL values are based on DAF=1"],"cite":{"instrument":"us_rsl_soil","title":"US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Soil","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"November 2024","source_url":"https://semspub.epa.gov/src/document/HQ/405270","source_sha256":"0160dc81b4f55d738a354a74de92488f149946ebfa7c6a6c64592f45348043d7","fetched_at":"2026-09-19","section":null,"page":null,"quote":null,"table":"ssl","column":"risque"}},{"id":"4c76d03235e492a5","parameter":"Parathion","value":"86","value_num":86,"unit":"µg/L","direction":"max","kind":"guideline","medium":"drinking_water","level":"national","parameter_key":"cas:56-38-2","place":["US"],"conditions":["Tap Water (ug/L): Regional Screening Level (RSL) Summary Table (TR=1E-06, HQ=1) November 2024"],"cite":{"instrument":"us_rsl_tapwater","title":"US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Tap Water","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"November 2024","source_url":"https://semspub.epa.gov/src/document/HQ/405270","source_sha256":"0160dc81b4f55d738a354a74de92488f149946ebfa7c6a6c64592f45348043d7","fetched_at":"2026-09-19","section":null,"page":null,"quote":null,"table":"eau","column":"eau_robinet"}},{"id":"d6c9684ae42fd7e4","parameter":"Methyl Parathion","value":"16","value_num":16,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"national","parameter_key":"cas:298-00-0","place":["US"],"conditions":["Resident Soil (mg/kg)"],"cite":{"instrument":"us_rsl_soil","title":"US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Soil","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"November 2024","source_url":"https://semspub.epa.gov/src/document/HQ/405270","source_sha256":"0160dc81b4f55d738a354a74de92488f149946ebfa7c6a6c64592f45348043d7","fetched_at":"2026-09-19","section":null,"page":null,"quote":null,"table":"sols","column":"residentiel"}},{"id":"6a57b509d2d415af","parameter":"Methyl Parathion","value":"210","value_num":210,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"national","parameter_key":"cas:298-00-0","place":["US"],"conditions":["Industrial Soil (mg/kg)"],"cite":{"instrument":"us_rsl_soil","title":"US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Soil","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"November 2024","source_url":"https://semspub.epa.gov/src/document/HQ/405270","source_sha256":"0160dc81b4f55d738a354a74de92488f149946ebfa7c6a6c64592f45348043d7","fetched_at":"2026-09-19","section":null,"page":null,"quote":null,"table":"sols","column":"industriel"}},{"id":"9a70b1074fcbd53b","parameter":"Methyl Parathion","value":"0.0074","value_num":0.0074,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"national","parameter_key":"cas:298-00-0","place":["US"],"conditions":["Protection of Groundwater SSLs: Risk-based SSL (mg/kg); SSL values are based on DAF=1"],"cite":{"instrument":"us_rsl_soil","title":"US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Soil","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"November 2024","source_url":"https://semspub.epa.gov/src/document/HQ/405270","source_sha256":"0160dc81b4f55d738a354a74de92488f149946ebfa7c6a6c64592f45348043d7","fetched_at":"2026-09-19","section":null,"page":null,"quote":null,"table":"ssl","column":"risque"}},{"id":"e7b82c123aad58fc","parameter":"Methyl Parathion","value":"4.5","value_num":4.5,"unit":"µg/L","direction":"max","kind":"guideline","medium":"drinking_water","level":"national","parameter_key":"cas:298-00-0","place":["US"],"conditions":["Tap Water (ug/L): Regional Screening Level (RSL) Summary Table (TR=1E-06, HQ=1) November 2024"],"cite":{"instrument":"us_rsl_tapwater","title":"US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Tap Water","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"November 2024","source_url":"https://semspub.epa.gov/src/document/HQ/405270","source_sha256":"0160dc81b4f55d738a354a74de92488f149946ebfa7c6a6c64592f45348043d7","fetched_at":"2026-09-19","section":null,"page":null,"quote":null,"table":"eau","column":"eau_robinet"}}],"next":[{"tool":"check_values","says":"Has your user measured this? check_values sets each of their results beside every row held here, with a verdict and the row's cite.","arguments":{"place":"US-WI"},"needs":{"rows":"Your user's measured results, as their table prints them: [{parameter: \"parathion\", value, unit}, ...], any other parameters too."},"post":"/api/v1/check"},{"tool":"read_certificate","says":"Has your user a laboratory certificate? read_certificate reads every row it prints, each with its page, and checks them against these limits.","arguments":{"place":"US-WI"},"needs":{"content_base64":"The laboratory's certificate (PDF) or its XLSX, XLS or CSV export, as base64; or file_url, a public https address of it."},"post":"/api/v1/certificate"}]}