{"query":{"parameter":"nitrate nitrite as n","place":"US-FL","medium":null,"statistic":null,"kind":null},"searched":{"places":["US-FL","US"],"parameter_keys":["name:nitrate + nitrite","name:nitrate + nitrite as n","name:nitrate+nitrite","name:nitrate/nitrite","name:nitrate/nitrite as n","name:nitrate and nitrite","name:nitrate plus nitrite"],"names_matched":[["nitrate nitrite as n","name:nitrate + nitrite"],["nitrate nitrite as n","name:nitrate + nitrite as n"],["nitrate nitrite as n","name:nitrate+nitrite"],["nitrate nitrite as n","name:nitrate/nitrite"],["nitrate nitrite as n","name:nitrate/nitrite as n"],["nitrate and nitrite as n","name:nitrate and nitrite"],["nitrate plus nitrite as nitrogen n","name:nitrate plus nitrite"]],"match":"exact+contains","order":"The place's own instruments first, then each place above it, each in its register's order"},"total":8,"offset":0,"returned":8,"next_offset":null,"rows":[{"id":"eb2d6269442184b9","parameter":"Nitrate+Nitrite","value":"10000","value_num":10000,"unit":"µg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"name:nitrate+nitrite","place":["US-FL"],"conditions":["groundwater (Table I, Groundwater Criteria column)","Note: If more than one contaminant is present at a site, CTLs are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Figure 10 of the February 2005 'Final Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.' However, GCTLs for primary and secondary standards shall not be modified."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"Ch. 62-777 F.A.C. Table I, Groundwater and Surface Water Cleanup Target Levels, Groundwater Criteria (DEP spreadsheet, sheet TTable1, row 385)","page":null,"quote":"row 385: Nitrate+Nitrite | 10000 |  |  | 100000 | -Blood  | NOCAS |  | Primary Standard | NA | NA |  | Systemic Toxicant"}},{"id":"f8db6c17123485e3","parameter":"Nitrate+Nitrite","value":"100000","value_num":100000,"unit":"µg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"name:nitrate+nitrite","place":["US-FL"],"conditions":["groundwater of low yield/poor quality (Table I, Groundwater of Low Yield/Poor Quality Criteria column)","Note: If more than one contaminant is present at a site, CTLs are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Figure 10 of the February 2005 'Final Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.' However, GCTLs for primary and secondary standards shall not be modified."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"Ch. 62-777 F.A.C. Table I, Groundwater and Surface Water Cleanup Target Levels, Groundwater of Low Yield/Poor Quality Criteria (DEP spreadsheet, sheet TTable1, row 385)","page":null,"quote":"row 385: Nitrate+Nitrite | 10000 |  |  | 100000 | -Blood  | NOCAS |  | Primary Standard | NA | NA |  | Systemic Toxicant"}},{"id":"ff236569b4a13740","parameter":"Nitrate/Nitrite","value":"2.0","value_num":2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:nitrate/nitrite","place":["US"],"conditions":["route is direct","cites is 40 CFR 423","existing sources (BAT)","(3) Voluntary incentives plan. (i) For dischargers who voluntarily choose to meet the effluent limitations for FGD wastewater in this paragraph (g)(3)(i), the quantity of pollutants in FGD wastewater shall not exceed the quantity determined by multiplying the flow of FGD wastewater times the concentration listed in table 7 to this paragraph (g)(3)(i). Dischargers who choose to meet the effluent…","table: Table 7 to Paragraph ( g )(3)( i )"],"cite":{"instrument":"us_40cfr423","title":"40 CFR Part 423 — PART 423—STEAM ELECTRIC POWER GENERATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=423","source_sha256":"60cadc14b8fc25c39238a9d55cede55743d6b349ca20c8f8158b0f7e5d98fd64","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 423.13 (BAT)","page":null,"quote":"Nitrate/Nitrite (mg/L) 2.0 1.2"}},{"id":"bd56f70d10e7221f","parameter":"Nitrate/Nitrite","value":"1.2","value_num":1.2,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:nitrate/nitrite","place":["US"],"conditions":["route is direct","cites is 40 CFR 423","existing sources (BAT)","(3) Voluntary incentives plan. (i) For dischargers who voluntarily choose to meet the effluent limitations for FGD wastewater in this paragraph (g)(3)(i), the quantity of pollutants in FGD wastewater shall not exceed the quantity determined by multiplying the flow of FGD wastewater times the concentration listed in table 7 to this paragraph (g)(3)(i). Dischargers who choose to meet the effluent…","table: Table 7 to Paragraph ( g )(3)( i )"],"cite":{"instrument":"us_40cfr423","title":"40 CFR Part 423 — PART 423—STEAM ELECTRIC POWER GENERATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=423","source_sha256":"60cadc14b8fc25c39238a9d55cede55743d6b349ca20c8f8158b0f7e5d98fd64","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 423.13 (BAT)","page":null,"quote":"Nitrate/Nitrite (mg/L) 2.0 1.2"}},{"id":"ee7b591236c21357","parameter":"Nitrate/nitrite as N","value":"4","value_num":4,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:nitrate/nitrite as n","place":["US"],"conditions":["route is direct","cites is 40 CFR 423","existing sources (BAT)","(g) FGD wastewater —(1) 2020 BAT. (i) Except for those discharges to which paragraph (g)(2) or (3) of this section applies, the quantity of pollutants in FGD wastewater shall not exceed the quantity determined by multiplying the flow of FGD wastewater times the concentration listed in table 5 to this paragraph (g)(1)(i). Dischargers must meet the effluent limitations for FGD wastewater in this …","table: Table 5 to Paragraph ( g )(1)( i )"],"cite":{"instrument":"us_40cfr423","title":"40 CFR Part 423 — PART 423—STEAM ELECTRIC POWER GENERATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=423","source_sha256":"60cadc14b8fc25c39238a9d55cede55743d6b349ca20c8f8158b0f7e5d98fd64","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 423.13 (BAT)","page":null,"quote":"Nitrate/nitrite as N (mg/L) 4 3"}},{"id":"884b3043b1528c34","parameter":"Nitrate/nitrite as N","value":"3","value_num":3,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:nitrate/nitrite as n","place":["US"],"conditions":["route is direct","cites is 40 CFR 423","existing sources (BAT)","(g) FGD wastewater —(1) 2020 BAT. (i) Except for those discharges to which paragraph (g)(2) or (3) of this section applies, the quantity of pollutants in FGD wastewater shall not exceed the quantity determined by multiplying the flow of FGD wastewater times the concentration listed in table 5 to this paragraph (g)(1)(i). Dischargers must meet the effluent limitations for FGD wastewater in this …","table: Table 5 to Paragraph ( g )(1)( i )"],"cite":{"instrument":"us_40cfr423","title":"40 CFR Part 423 — PART 423—STEAM ELECTRIC POWER GENERATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=423","source_sha256":"60cadc14b8fc25c39238a9d55cede55743d6b349ca20c8f8158b0f7e5d98fd64","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 423.13 (BAT)","page":null,"quote":"Nitrate/nitrite as N (mg/L) 4 3"}},{"id":"53d6d195b2d1b594","parameter":"Nitrate/nitrite as N","value":"4","value_num":4,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"name:nitrate/nitrite as n","place":["US"],"conditions":["route is sewer","cites is 40 CFR 423","existing sources (PSES)","(e) FGD wastewater —(1) 2020 PSES. Except as provided for in paragraph (e)(2) of this section, for any electric generating unit with a total nameplate generating capacity of more than 50 megawatts, that is not an oil-fired unit, and that the owner has not certified that it will cease coal combustion pursuant to § 423.19(g), the quantity of pollutants in FGD wastewater shall not exceed the quant…","table: Table 3 to Paragraph (e)(1)"],"cite":{"instrument":"us_40cfr423","title":"40 CFR Part 423 — PART 423—STEAM ELECTRIC POWER GENERATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=423","source_sha256":"60cadc14b8fc25c39238a9d55cede55743d6b349ca20c8f8158b0f7e5d98fd64","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 423.16 (PSES)","page":null,"quote":"Nitrate/nitrite as N (mg/L) 4 3"}},{"id":"2c560d831e162389","parameter":"Nitrate/nitrite as N","value":"3","value_num":3,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"name:nitrate/nitrite as n","place":["US"],"conditions":["route is sewer","cites is 40 CFR 423","existing sources (PSES)","(e) FGD wastewater —(1) 2020 PSES. Except as provided for in paragraph (e)(2) of this section, for any electric generating unit with a total nameplate generating capacity of more than 50 megawatts, that is not an oil-fired unit, and that the owner has not certified that it will cease coal combustion pursuant to § 423.19(g), the quantity of pollutants in FGD wastewater shall not exceed the quant…","table: Table 3 to Paragraph (e)(1)"],"cite":{"instrument":"us_40cfr423","title":"40 CFR Part 423 — PART 423—STEAM ELECTRIC POWER GENERATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=423","source_sha256":"60cadc14b8fc25c39238a9d55cede55743d6b349ca20c8f8158b0f7e5d98fd64","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 423.16 (PSES)","page":null,"quote":"Nitrate/nitrite as N (mg/L) 4 3"}}],"next":[{"tool":"check_values","says":"Has your user measured this? check_values sets each of their results beside every row held here, with a verdict and the row's cite.","arguments":{"place":"US-FL"},"needs":{"rows":"Your user's measured results, as their table prints them: [{parameter: \"nitrate nitrite as n\", value, unit}, ...], any other parameters too."},"post":"/api/v1/check"},{"tool":"read_certificate","says":"Has your user a laboratory certificate? read_certificate reads every row it prints, each with its page, and checks them against these limits.","arguments":{"place":"US-FL"},"needs":{"content_base64":"The laboratory's certificate (PDF) or its XLSX, XLS or CSV export, as base64; or file_url, a public https address of it."},"post":"/api/v1/certificate"}]}