{"query":{"parameter":"nickel","place":"US-OH","medium":null,"statistic":null,"kind":null},"searched":{"places":["US-OH","US"],"parameter_keys":["cas:7440-02-0","name:iron, nickel (h), zinc","cas:373-02-4","cas:3333-67-3","cas:13463-39-3","name:nickel extractible","cas:12054-48-7","cas:1313-99-1","name:nickel refinery dust","cas:12035-72-2","name:nickel - total","name:nickel, total","name:total nickel"],"names_matched":[["nickel","cas:7440-02-0"],["iron nickel h zinc","name:iron, nickel (h), zinc"],["iron nickel h zinc h","name:iron, nickel (h), zinc"],["nickel acetate","cas:373-02-4"],["nickel carbonate","cas:3333-67-3"],["nickel carbonyl","cas:13463-39-3"],["nickel carbonyl ni co 4 t 4","cas:13463-39-3"],["nickel extractible","name:nickel extractible"],["nickel hydroxide","cas:12054-48-7"],["nickel hydroxide ni oh 2","cas:12054-48-7"],["nickel ii acetate","cas:373-02-4"],["nickel ii oxide","cas:1313-99-1"],["nickel oxide","cas:1313-99-1"],["nickel refinery dust","name:nickel refinery dust"],["nickel subsulfide","cas:12035-72-2"],["nickel total","name:nickel - total"],["nickel total","name:nickel, total"],["total nickel","name:total nickel"],["total nickel freshwater","name:total nickel"],["total nickel marine","name:total nickel"]],"match":"exact+contains","order":"The place's own instruments first, then each place above it, each in its register's order; rows for a marine receiving water after the rest, as none of the place's own rows names a marine, salt, estuarine, coastal or ocean water"},"total":2138,"offset":0,"returned":50,"next_offset":50,"rows":[{"id":"7cab501cdef40da1","parameter":"Nickel (dissolved)","value":"e(0.846 [ln H] + 2.946)","unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-02-0","place":["US-OH"],"conditions":["receiving_water is freshwater","hardness-dependent: the row's equation of the receiving water's hardness (up to 400 mg/l CaCO3; above 400 the 400 value)"],"cite":{"instrument":"us_oh_wqs","title":"Ohio Administrative Code Chapter 3745-1 Water Quality Standards: statewide aquatic life (Table 35-1, hardness and pH equations 35-9/35-10), wildlife (35-12), public water supply (33-1), agricultural supply (33-3), fish consumption (34-1), aesthetic (37-1) and Ohio river (32-1/32-2) criteria","issuer":"State of Ohio, Environmental Protection Agency","edition":"OAC 3745-1-01 to -44 and -50 to -54, effective March 16, 2026, as US EPA posts it in effect for CWA purposes (cover letter March 25, 2026: EPA disapproved, April 27, 2021, 44 lake Erie public water supply criteria of Table 33-1)","source_url":"https://www.epa.gov/sites/default/files/2015-09/documents/oh_34751_1_to_40.pdf","source_sha256":"129b8170e3fe705fd7b0be22d6ca7eb6bf37bfc003df0348bb42b8e67c60f9d0","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"OAC 3745-1-35 Table 35-9","page":481,"quote":"IMZM3 D4 µg/l e(0.846 [ln H] + 2.946) 940 1700 2400 3000"}},{"id":"2371bf6b1ae90a1a","parameter":"Nickel (dissolved)","value":"940","value_num":940,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-02-0","place":["US-OH"],"conditions":["receiving_water is freshwater","hardness 100 mg/l CaCO3 (Table 35-9's example)"],"cite":{"instrument":"us_oh_wqs","title":"Ohio Administrative Code Chapter 3745-1 Water Quality Standards: statewide aquatic life (Table 35-1, hardness and pH equations 35-9/35-10), wildlife (35-12), public water supply (33-1), agricultural supply (33-3), fish consumption (34-1), aesthetic (37-1) and Ohio river (32-1/32-2) criteria","issuer":"State of Ohio, Environmental Protection Agency","edition":"OAC 3745-1-01 to -44 and -50 to -54, effective March 16, 2026, as US EPA posts it in effect for CWA purposes (cover letter March 25, 2026: EPA disapproved, April 27, 2021, 44 lake Erie public water supply criteria of Table 33-1)","source_url":"https://www.epa.gov/sites/default/files/2015-09/documents/oh_34751_1_to_40.pdf","source_sha256":"129b8170e3fe705fd7b0be22d6ca7eb6bf37bfc003df0348bb42b8e67c60f9d0","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"OAC 3745-1-35 Table 35-9","page":481,"quote":"IMZM3 D4 µg/l e(0.846 [ln H] + 2.946) 940 1700 2400 3000"}},{"id":"ceec09f687790b34","parameter":"Nickel (dissolved)","value":"1700","value_num":1700,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-02-0","place":["US-OH"],"conditions":["receiving_water is freshwater","hardness 200 mg/l CaCO3 (Table 35-9's example)"],"cite":{"instrument":"us_oh_wqs","title":"Ohio Administrative Code Chapter 3745-1 Water Quality Standards: statewide aquatic life (Table 35-1, hardness and pH equations 35-9/35-10), wildlife (35-12), public water supply (33-1), agricultural supply (33-3), fish consumption (34-1), aesthetic (37-1) and Ohio river (32-1/32-2) criteria","issuer":"State of Ohio, Environmental Protection Agency","edition":"OAC 3745-1-01 to -44 and -50 to -54, effective March 16, 2026, as US EPA posts it in effect for CWA purposes (cover letter March 25, 2026: EPA disapproved, April 27, 2021, 44 lake Erie public water supply criteria of Table 33-1)","source_url":"https://www.epa.gov/sites/default/files/2015-09/documents/oh_34751_1_to_40.pdf","source_sha256":"129b8170e3fe705fd7b0be22d6ca7eb6bf37bfc003df0348bb42b8e67c60f9d0","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"OAC 3745-1-35 Table 35-9","page":481,"quote":"IMZM3 D4 µg/l e(0.846 [ln H] + 2.946) 940 1700 2400 3000"}},{"id":"671c10019445e420","parameter":"Nickel (dissolved)","value":"2400","value_num":2400,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-02-0","place":["US-OH"],"conditions":["receiving_water is freshwater","hardness 300 mg/l CaCO3 (Table 35-9's example)"],"cite":{"instrument":"us_oh_wqs","title":"Ohio Administrative Code Chapter 3745-1 Water Quality Standards: statewide aquatic life (Table 35-1, hardness and pH equations 35-9/35-10), wildlife (35-12), public water supply (33-1), agricultural supply (33-3), fish consumption (34-1), aesthetic (37-1) and Ohio river (32-1/32-2) criteria","issuer":"State of Ohio, Environmental Protection Agency","edition":"OAC 3745-1-01 to -44 and -50 to -54, effective March 16, 2026, as US EPA posts it in effect for CWA purposes (cover letter March 25, 2026: EPA disapproved, April 27, 2021, 44 lake Erie public water supply criteria of Table 33-1)","source_url":"https://www.epa.gov/sites/default/files/2015-09/documents/oh_34751_1_to_40.pdf","source_sha256":"129b8170e3fe705fd7b0be22d6ca7eb6bf37bfc003df0348bb42b8e67c60f9d0","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"OAC 3745-1-35 Table 35-9","page":481,"quote":"IMZM3 D4 µg/l e(0.846 [ln H] + 2.946) 940 1700 2400 3000"}},{"id":"dbaa451b94e56cc7","parameter":"Nickel (dissolved)","value":"3000","value_num":3000,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-02-0","place":["US-OH"],"conditions":["receiving_water is freshwater","hardness 400 mg/l CaCO3 or above (note 6: the 400 mg/l criteria are used above 400)"],"cite":{"instrument":"us_oh_wqs","title":"Ohio Administrative Code Chapter 3745-1 Water Quality Standards: statewide aquatic life (Table 35-1, hardness and pH equations 35-9/35-10), wildlife (35-12), public water supply (33-1), agricultural supply (33-3), fish consumption (34-1), aesthetic (37-1) and Ohio river (32-1/32-2) criteria","issuer":"State of Ohio, Environmental Protection Agency","edition":"OAC 3745-1-01 to -44 and -50 to -54, effective March 16, 2026, as US EPA posts it in effect for CWA purposes (cover letter March 25, 2026: EPA disapproved, April 27, 2021, 44 lake Erie public water supply criteria of Table 33-1)","source_url":"https://www.epa.gov/sites/default/files/2015-09/documents/oh_34751_1_to_40.pdf","source_sha256":"129b8170e3fe705fd7b0be22d6ca7eb6bf37bfc003df0348bb42b8e67c60f9d0","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"OAC 3745-1-35 Table 35-9","page":481,"quote":"IMZM3 D4 µg/l e(0.846 [ln H] + 2.946) 940 1700 2400 3000"}},{"id":"c483a80ced1ca256","parameter":"Nickel (dissolved)","value":"e(0.846 [ln H] + 2.253)","unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-02-0","place":["US-OH"],"conditions":["receiving_water is freshwater","hardness-dependent: the row's equation of the receiving water's hardness (up to 400 mg/l CaCO3; above 400 the 400 value)"],"cite":{"instrument":"us_oh_wqs","title":"Ohio Administrative Code Chapter 3745-1 Water Quality Standards: statewide aquatic life (Table 35-1, hardness and pH equations 35-9/35-10), wildlife (35-12), public water supply (33-1), agricultural supply (33-3), fish consumption (34-1), aesthetic (37-1) and Ohio river (32-1/32-2) criteria","issuer":"State of Ohio, Environmental Protection Agency","edition":"OAC 3745-1-01 to -44 and -50 to -54, effective March 16, 2026, as US EPA posts it in effect for CWA purposes (cover letter March 25, 2026: EPA disapproved, April 27, 2021, 44 lake Erie public water supply criteria of Table 33-1)","source_url":"https://www.epa.gov/sites/default/files/2015-09/documents/oh_34751_1_to_40.pdf","source_sha256":"129b8170e3fe705fd7b0be22d6ca7eb6bf37bfc003df0348bb42b8e67c60f9d0","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"OAC 3745-1-35 Table 35-9","page":481,"quote":"OMZM3 D4 µg/l e(0.846 [ln H] + 2.253) 470 840 1200 1500"}},{"id":"5bbb8aaf17d79d8a","parameter":"Nickel (dissolved)","value":"470","value_num":470,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-02-0","place":["US-OH"],"conditions":["receiving_water is freshwater","hardness 100 mg/l CaCO3 (Table 35-9's example)"],"cite":{"instrument":"us_oh_wqs","title":"Ohio Administrative Code Chapter 3745-1 Water Quality Standards: statewide aquatic life (Table 35-1, hardness and pH equations 35-9/35-10), wildlife (35-12), public water supply (33-1), agricultural supply (33-3), fish consumption (34-1), aesthetic (37-1) and Ohio river (32-1/32-2) criteria","issuer":"State of Ohio, Environmental Protection Agency","edition":"OAC 3745-1-01 to -44 and -50 to -54, effective March 16, 2026, as US EPA posts it in effect for CWA purposes (cover letter March 25, 2026: EPA disapproved, April 27, 2021, 44 lake Erie public water supply criteria of Table 33-1)","source_url":"https://www.epa.gov/sites/default/files/2015-09/documents/oh_34751_1_to_40.pdf","source_sha256":"129b8170e3fe705fd7b0be22d6ca7eb6bf37bfc003df0348bb42b8e67c60f9d0","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"OAC 3745-1-35 Table 35-9","page":481,"quote":"OMZM3 D4 µg/l e(0.846 [ln H] + 2.253) 470 840 1200 1500"}},{"id":"31bf8133087cc7a0","parameter":"Nickel (dissolved)","value":"840","value_num":840,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-02-0","place":["US-OH"],"conditions":["receiving_water is freshwater","hardness 200 mg/l CaCO3 (Table 35-9's example)"],"cite":{"instrument":"us_oh_wqs","title":"Ohio Administrative Code Chapter 3745-1 Water Quality Standards: statewide aquatic life (Table 35-1, hardness and pH equations 35-9/35-10), wildlife (35-12), public water supply (33-1), agricultural supply (33-3), fish consumption (34-1), aesthetic (37-1) and Ohio river (32-1/32-2) criteria","issuer":"State of Ohio, Environmental Protection Agency","edition":"OAC 3745-1-01 to -44 and -50 to -54, effective March 16, 2026, as US EPA posts it in effect for CWA purposes (cover letter March 25, 2026: EPA disapproved, April 27, 2021, 44 lake Erie public water supply criteria of Table 33-1)","source_url":"https://www.epa.gov/sites/default/files/2015-09/documents/oh_34751_1_to_40.pdf","source_sha256":"129b8170e3fe705fd7b0be22d6ca7eb6bf37bfc003df0348bb42b8e67c60f9d0","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"OAC 3745-1-35 Table 35-9","page":481,"quote":"OMZM3 D4 µg/l e(0.846 [ln H] + 2.253) 470 840 1200 1500"}},{"id":"ce1aa3085dc5feab","parameter":"Nickel (dissolved)","value":"1200","value_num":1200,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-02-0","place":["US-OH"],"conditions":["receiving_water is freshwater","hardness 300 mg/l CaCO3 (Table 35-9's example)"],"cite":{"instrument":"us_oh_wqs","title":"Ohio Administrative Code Chapter 3745-1 Water Quality Standards: statewide aquatic life (Table 35-1, hardness and pH equations 35-9/35-10), wildlife (35-12), public water supply (33-1), agricultural supply (33-3), fish consumption (34-1), aesthetic (37-1) and Ohio river (32-1/32-2) criteria","issuer":"State of Ohio, Environmental Protection Agency","edition":"OAC 3745-1-01 to -44 and -50 to -54, effective March 16, 2026, as US EPA posts it in effect for CWA purposes (cover letter March 25, 2026: EPA disapproved, April 27, 2021, 44 lake Erie public water supply criteria of Table 33-1)","source_url":"https://www.epa.gov/sites/default/files/2015-09/documents/oh_34751_1_to_40.pdf","source_sha256":"129b8170e3fe705fd7b0be22d6ca7eb6bf37bfc003df0348bb42b8e67c60f9d0","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"OAC 3745-1-35 Table 35-9","page":481,"quote":"OMZM3 D4 µg/l e(0.846 [ln H] + 2.253) 470 840 1200 1500"}},{"id":"43b82afaf693e0bb","parameter":"Nickel (dissolved)","value":"1500","value_num":1500,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-02-0","place":["US-OH"],"conditions":["receiving_water is freshwater","hardness 400 mg/l CaCO3 or above (note 6: the 400 mg/l criteria are used above 400)"],"cite":{"instrument":"us_oh_wqs","title":"Ohio Administrative Code Chapter 3745-1 Water Quality Standards: statewide aquatic life (Table 35-1, hardness and pH equations 35-9/35-10), wildlife (35-12), public water supply (33-1), agricultural supply (33-3), fish consumption (34-1), aesthetic (37-1) and Ohio river (32-1/32-2) criteria","issuer":"State of Ohio, Environmental Protection Agency","edition":"OAC 3745-1-01 to -44 and -50 to -54, effective March 16, 2026, as US EPA posts it in effect for CWA purposes (cover letter March 25, 2026: EPA disapproved, April 27, 2021, 44 lake Erie public water supply criteria of Table 33-1)","source_url":"https://www.epa.gov/sites/default/files/2015-09/documents/oh_34751_1_to_40.pdf","source_sha256":"129b8170e3fe705fd7b0be22d6ca7eb6bf37bfc003df0348bb42b8e67c60f9d0","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"OAC 3745-1-35 Table 35-9","page":481,"quote":"OMZM3 D4 µg/l e(0.846 [ln H] + 2.253) 470 840 1200 1500"}},{"id":"cf397db6e3901c6d","parameter":"Nickel (dissolved)","value":"e(0.846 [ln H] + 0.0554)","unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-02-0","place":["US-OH"],"conditions":["receiving_water is freshwater","hardness-dependent: the row's equation of the receiving water's hardness (up to 400 mg/l CaCO3; above 400 the 400 value)"],"cite":{"instrument":"us_oh_wqs","title":"Ohio Administrative Code Chapter 3745-1 Water Quality Standards: statewide aquatic life (Table 35-1, hardness and pH equations 35-9/35-10), wildlife (35-12), public water supply (33-1), agricultural supply (33-3), fish consumption (34-1), aesthetic (37-1) and Ohio river (32-1/32-2) criteria","issuer":"State of Ohio, Environmental Protection Agency","edition":"OAC 3745-1-01 to -44 and -50 to -54, effective March 16, 2026, as US EPA posts it in effect for CWA purposes (cover letter March 25, 2026: EPA disapproved, April 27, 2021, 44 lake Erie public water supply criteria of Table 33-1)","source_url":"https://www.epa.gov/sites/default/files/2015-09/documents/oh_34751_1_to_40.pdf","source_sha256":"129b8170e3fe705fd7b0be22d6ca7eb6bf37bfc003df0348bb42b8e67c60f9d0","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"OAC 3745-1-35 Table 35-9","page":481,"quote":"OMZA3 D4 µg/l e(0.846 [ln H] + 0.0554) 52 93 130 170"}},{"id":"5679ff513cce1fc0","parameter":"Nickel (dissolved)","value":"52","value_num":52,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-02-0","place":["US-OH"],"conditions":["receiving_water is freshwater","hardness 100 mg/l CaCO3 (Table 35-9's example)"],"cite":{"instrument":"us_oh_wqs","title":"Ohio Administrative Code Chapter 3745-1 Water Quality Standards: statewide aquatic life (Table 35-1, hardness and pH equations 35-9/35-10), wildlife (35-12), public water supply (33-1), agricultural supply (33-3), fish consumption (34-1), aesthetic (37-1) and Ohio river (32-1/32-2) criteria","issuer":"State of Ohio, Environmental Protection Agency","edition":"OAC 3745-1-01 to -44 and -50 to -54, effective March 16, 2026, as US EPA posts it in effect for CWA purposes (cover letter March 25, 2026: EPA disapproved, April 27, 2021, 44 lake Erie public water supply criteria of Table 33-1)","source_url":"https://www.epa.gov/sites/default/files/2015-09/documents/oh_34751_1_to_40.pdf","source_sha256":"129b8170e3fe705fd7b0be22d6ca7eb6bf37bfc003df0348bb42b8e67c60f9d0","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"OAC 3745-1-35 Table 35-9","page":481,"quote":"OMZA3 D4 µg/l e(0.846 [ln H] + 0.0554) 52 93 130 170"}},{"id":"36228b2577514e18","parameter":"Nickel (dissolved)","value":"93","value_num":93,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-02-0","place":["US-OH"],"conditions":["receiving_water is freshwater","hardness 200 mg/l CaCO3 (Table 35-9's example)"],"cite":{"instrument":"us_oh_wqs","title":"Ohio Administrative Code Chapter 3745-1 Water Quality Standards: statewide aquatic life (Table 35-1, hardness and pH equations 35-9/35-10), wildlife (35-12), public water supply (33-1), agricultural supply (33-3), fish consumption (34-1), aesthetic (37-1) and Ohio river (32-1/32-2) criteria","issuer":"State of Ohio, Environmental Protection Agency","edition":"OAC 3745-1-01 to -44 and -50 to -54, effective March 16, 2026, as US EPA posts it in effect for CWA purposes (cover letter March 25, 2026: EPA disapproved, April 27, 2021, 44 lake Erie public water supply criteria of Table 33-1)","source_url":"https://www.epa.gov/sites/default/files/2015-09/documents/oh_34751_1_to_40.pdf","source_sha256":"129b8170e3fe705fd7b0be22d6ca7eb6bf37bfc003df0348bb42b8e67c60f9d0","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"OAC 3745-1-35 Table 35-9","page":481,"quote":"OMZA3 D4 µg/l e(0.846 [ln H] + 0.0554) 52 93 130 170"}},{"id":"61729081b40bde8c","parameter":"Nickel (dissolved)","value":"130","value_num":130,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-02-0","place":["US-OH"],"conditions":["receiving_water is freshwater","hardness 300 mg/l CaCO3 (Table 35-9's example)"],"cite":{"instrument":"us_oh_wqs","title":"Ohio Administrative Code Chapter 3745-1 Water Quality Standards: statewide aquatic life (Table 35-1, hardness and pH equations 35-9/35-10), wildlife (35-12), public water supply (33-1), agricultural supply (33-3), fish consumption (34-1), aesthetic (37-1) and Ohio river (32-1/32-2) criteria","issuer":"State of Ohio, Environmental Protection Agency","edition":"OAC 3745-1-01 to -44 and -50 to -54, effective March 16, 2026, as US EPA posts it in effect for CWA purposes (cover letter March 25, 2026: EPA disapproved, April 27, 2021, 44 lake Erie public water supply criteria of Table 33-1)","source_url":"https://www.epa.gov/sites/default/files/2015-09/documents/oh_34751_1_to_40.pdf","source_sha256":"129b8170e3fe705fd7b0be22d6ca7eb6bf37bfc003df0348bb42b8e67c60f9d0","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"OAC 3745-1-35 Table 35-9","page":481,"quote":"OMZA3 D4 µg/l e(0.846 [ln H] + 0.0554) 52 93 130 170"}},{"id":"c62ec283f3cf403c","parameter":"Nickel (dissolved)","value":"170","value_num":170,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-02-0","place":["US-OH"],"conditions":["receiving_water is freshwater","hardness 400 mg/l CaCO3 or above (note 6: the 400 mg/l criteria are used above 400)"],"cite":{"instrument":"us_oh_wqs","title":"Ohio Administrative Code Chapter 3745-1 Water Quality Standards: statewide aquatic life (Table 35-1, hardness and pH equations 35-9/35-10), wildlife (35-12), public water supply (33-1), agricultural supply (33-3), fish consumption (34-1), aesthetic (37-1) and Ohio river (32-1/32-2) criteria","issuer":"State of Ohio, Environmental Protection Agency","edition":"OAC 3745-1-01 to -44 and -50 to -54, effective March 16, 2026, as US EPA posts it in effect for CWA purposes (cover letter March 25, 2026: EPA disapproved, April 27, 2021, 44 lake Erie public water supply criteria of Table 33-1)","source_url":"https://www.epa.gov/sites/default/files/2015-09/documents/oh_34751_1_to_40.pdf","source_sha256":"129b8170e3fe705fd7b0be22d6ca7eb6bf37bfc003df0348bb42b8e67c60f9d0","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"OAC 3745-1-35 Table 35-9","page":481,"quote":"OMZA3 D4 µg/l e(0.846 [ln H] + 0.0554) 52 93 130 170"}},{"id":"245bf418c774fb4b","parameter":"Nickel (total recoverable)","value":"e(0.846 [ln H] + 2.948)","unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-02-0","place":["US-OH"],"conditions":["receiving_water is freshwater","hardness-dependent: the row's equation of the receiving water's hardness (up to 400 mg/l CaCO3; above 400 the 400 value)"],"cite":{"instrument":"us_oh_wqs","title":"Ohio Administrative Code Chapter 3745-1 Water Quality Standards: statewide aquatic life (Table 35-1, hardness and pH equations 35-9/35-10), wildlife (35-12), public water supply (33-1), agricultural supply (33-3), fish consumption (34-1), aesthetic (37-1) and Ohio river (32-1/32-2) criteria","issuer":"State of Ohio, Environmental Protection Agency","edition":"OAC 3745-1-01 to -44 and -50 to -54, effective March 16, 2026, as US EPA posts it in effect for CWA purposes (cover letter March 25, 2026: EPA disapproved, April 27, 2021, 44 lake Erie public water supply criteria of Table 33-1)","source_url":"https://www.epa.gov/sites/default/files/2015-09/documents/oh_34751_1_to_40.pdf","source_sha256":"129b8170e3fe705fd7b0be22d6ca7eb6bf37bfc003df0348bb42b8e67c60f9d0","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"OAC 3745-1-35 Table 35-9","page":481,"quote":"IMZM3 TR5 µg/l e(0.846 [ln H] + 2.948) 940 1700 2400 3000"}},{"id":"5a0ac15e3531f1d9","parameter":"Nickel (total recoverable)","value":"940","value_num":940,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-02-0","place":["US-OH"],"conditions":["receiving_water is freshwater","hardness 100 mg/l CaCO3 (Table 35-9's example)"],"cite":{"instrument":"us_oh_wqs","title":"Ohio Administrative Code Chapter 3745-1 Water Quality Standards: statewide aquatic life (Table 35-1, hardness and pH equations 35-9/35-10), wildlife (35-12), public water supply (33-1), agricultural supply (33-3), fish consumption (34-1), aesthetic (37-1) and Ohio river (32-1/32-2) criteria","issuer":"State of Ohio, Environmental Protection Agency","edition":"OAC 3745-1-01 to -44 and -50 to -54, effective March 16, 2026, as US EPA posts it in effect for CWA purposes (cover letter March 25, 2026: EPA disapproved, April 27, 2021, 44 lake Erie public water supply criteria of Table 33-1)","source_url":"https://www.epa.gov/sites/default/files/2015-09/documents/oh_34751_1_to_40.pdf","source_sha256":"129b8170e3fe705fd7b0be22d6ca7eb6bf37bfc003df0348bb42b8e67c60f9d0","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"OAC 3745-1-35 Table 35-9","page":481,"quote":"IMZM3 TR5 µg/l e(0.846 [ln H] + 2.948) 940 1700 2400 3000"}},{"id":"dc9a91a79a2cab4c","parameter":"Nickel (total recoverable)","value":"1700","value_num":1700,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-02-0","place":["US-OH"],"conditions":["receiving_water is freshwater","hardness 200 mg/l CaCO3 (Table 35-9's example)"],"cite":{"instrument":"us_oh_wqs","title":"Ohio Administrative Code Chapter 3745-1 Water Quality Standards: statewide aquatic life (Table 35-1, hardness and pH equations 35-9/35-10), wildlife (35-12), public water supply (33-1), agricultural supply (33-3), fish consumption (34-1), aesthetic (37-1) and Ohio river (32-1/32-2) criteria","issuer":"State of Ohio, Environmental Protection Agency","edition":"OAC 3745-1-01 to -44 and -50 to -54, effective March 16, 2026, as US EPA posts it in effect for CWA purposes (cover letter March 25, 2026: EPA disapproved, April 27, 2021, 44 lake Erie public water supply criteria of Table 33-1)","source_url":"https://www.epa.gov/sites/default/files/2015-09/documents/oh_34751_1_to_40.pdf","source_sha256":"129b8170e3fe705fd7b0be22d6ca7eb6bf37bfc003df0348bb42b8e67c60f9d0","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"OAC 3745-1-35 Table 35-9","page":481,"quote":"IMZM3 TR5 µg/l e(0.846 [ln H] + 2.948) 940 1700 2400 3000"}},{"id":"84b19eb182c232b5","parameter":"Nickel (total recoverable)","value":"2400","value_num":2400,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-02-0","place":["US-OH"],"conditions":["receiving_water is freshwater","hardness 300 mg/l CaCO3 (Table 35-9's example)"],"cite":{"instrument":"us_oh_wqs","title":"Ohio Administrative Code Chapter 3745-1 Water Quality Standards: statewide aquatic life (Table 35-1, hardness and pH equations 35-9/35-10), wildlife (35-12), public water supply (33-1), agricultural supply (33-3), fish consumption (34-1), aesthetic (37-1) and Ohio river (32-1/32-2) criteria","issuer":"State of Ohio, Environmental Protection Agency","edition":"OAC 3745-1-01 to -44 and -50 to -54, effective March 16, 2026, as US EPA posts it in effect for CWA purposes (cover letter March 25, 2026: EPA disapproved, April 27, 2021, 44 lake Erie public water supply criteria of Table 33-1)","source_url":"https://www.epa.gov/sites/default/files/2015-09/documents/oh_34751_1_to_40.pdf","source_sha256":"129b8170e3fe705fd7b0be22d6ca7eb6bf37bfc003df0348bb42b8e67c60f9d0","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"OAC 3745-1-35 Table 35-9","page":481,"quote":"IMZM3 TR5 µg/l e(0.846 [ln H] + 2.948) 940 1700 2400 3000"}},{"id":"ce54ff3d33986df5","parameter":"Nickel (total recoverable)","value":"3000","value_num":3000,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-02-0","place":["US-OH"],"conditions":["receiving_water is freshwater","hardness 400 mg/l CaCO3 or above (note 6: the 400 mg/l criteria are used above 400)"],"cite":{"instrument":"us_oh_wqs","title":"Ohio Administrative Code Chapter 3745-1 Water Quality Standards: statewide aquatic life (Table 35-1, hardness and pH equations 35-9/35-10), wildlife (35-12), public water supply (33-1), agricultural supply (33-3), fish consumption (34-1), aesthetic (37-1) and Ohio river (32-1/32-2) criteria","issuer":"State of Ohio, Environmental Protection Agency","edition":"OAC 3745-1-01 to -44 and -50 to -54, effective March 16, 2026, as US EPA posts it in effect for CWA purposes (cover letter March 25, 2026: EPA disapproved, April 27, 2021, 44 lake Erie public water supply criteria of Table 33-1)","source_url":"https://www.epa.gov/sites/default/files/2015-09/documents/oh_34751_1_to_40.pdf","source_sha256":"129b8170e3fe705fd7b0be22d6ca7eb6bf37bfc003df0348bb42b8e67c60f9d0","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"OAC 3745-1-35 Table 35-9","page":481,"quote":"IMZM3 TR5 µg/l e(0.846 [ln H] + 2.948) 940 1700 2400 3000"}},{"id":"7186a3c6a1b8c5b4","parameter":"Nickel (total recoverable)","value":"e(0.846 [ln H] + 2.255)","unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-02-0","place":["US-OH"],"conditions":["receiving_water is freshwater","hardness-dependent: the row's equation of the receiving water's hardness (up to 400 mg/l CaCO3; above 400 the 400 value)"],"cite":{"instrument":"us_oh_wqs","title":"Ohio Administrative Code Chapter 3745-1 Water Quality Standards: statewide aquatic life (Table 35-1, hardness and pH equations 35-9/35-10), wildlife (35-12), public water supply (33-1), agricultural supply (33-3), fish consumption (34-1), aesthetic (37-1) and Ohio river (32-1/32-2) criteria","issuer":"State of Ohio, Environmental Protection Agency","edition":"OAC 3745-1-01 to -44 and -50 to -54, effective March 16, 2026, as US EPA posts it in effect for CWA purposes (cover letter March 25, 2026: EPA disapproved, April 27, 2021, 44 lake Erie public water supply criteria of Table 33-1)","source_url":"https://www.epa.gov/sites/default/files/2015-09/documents/oh_34751_1_to_40.pdf","source_sha256":"129b8170e3fe705fd7b0be22d6ca7eb6bf37bfc003df0348bb42b8e67c60f9d0","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"OAC 3745-1-35 Table 35-9","page":481,"quote":"OMZM3 TR5 µg/l e(0.846 [ln H] + 2.255) 470 840 1200 1500"}},{"id":"1509f3f6840da2ac","parameter":"Nickel (total recoverable)","value":"470","value_num":470,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-02-0","place":["US-OH"],"conditions":["receiving_water is freshwater","hardness 100 mg/l CaCO3 (Table 35-9's example)"],"cite":{"instrument":"us_oh_wqs","title":"Ohio Administrative Code Chapter 3745-1 Water Quality Standards: statewide aquatic life (Table 35-1, hardness and pH equations 35-9/35-10), wildlife (35-12), public water supply (33-1), agricultural supply (33-3), fish consumption (34-1), aesthetic (37-1) and Ohio river (32-1/32-2) criteria","issuer":"State of Ohio, Environmental Protection Agency","edition":"OAC 3745-1-01 to -44 and -50 to -54, effective March 16, 2026, as US EPA posts it in effect for CWA purposes (cover letter March 25, 2026: EPA disapproved, April 27, 2021, 44 lake Erie public water supply criteria of Table 33-1)","source_url":"https://www.epa.gov/sites/default/files/2015-09/documents/oh_34751_1_to_40.pdf","source_sha256":"129b8170e3fe705fd7b0be22d6ca7eb6bf37bfc003df0348bb42b8e67c60f9d0","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"OAC 3745-1-35 Table 35-9","page":481,"quote":"OMZM3 TR5 µg/l e(0.846 [ln H] + 2.255) 470 840 1200 1500"}},{"id":"95b85123a6c885e3","parameter":"Nickel (total recoverable)","value":"840","value_num":840,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-02-0","place":["US-OH"],"conditions":["receiving_water is freshwater","hardness 200 mg/l CaCO3 (Table 35-9's example)"],"cite":{"instrument":"us_oh_wqs","title":"Ohio Administrative Code Chapter 3745-1 Water Quality Standards: statewide aquatic life (Table 35-1, hardness and pH equations 35-9/35-10), wildlife (35-12), public water supply (33-1), agricultural supply (33-3), fish consumption (34-1), aesthetic (37-1) and Ohio river (32-1/32-2) criteria","issuer":"State of Ohio, Environmental Protection Agency","edition":"OAC 3745-1-01 to -44 and -50 to -54, effective March 16, 2026, as US EPA posts it in effect for CWA purposes (cover letter March 25, 2026: EPA disapproved, April 27, 2021, 44 lake Erie public water supply criteria of Table 33-1)","source_url":"https://www.epa.gov/sites/default/files/2015-09/documents/oh_34751_1_to_40.pdf","source_sha256":"129b8170e3fe705fd7b0be22d6ca7eb6bf37bfc003df0348bb42b8e67c60f9d0","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"OAC 3745-1-35 Table 35-9","page":481,"quote":"OMZM3 TR5 µg/l e(0.846 [ln H] + 2.255) 470 840 1200 1500"}},{"id":"21f0aaa24ced4891","parameter":"Nickel (total recoverable)","value":"1200","value_num":1200,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-02-0","place":["US-OH"],"conditions":["receiving_water is freshwater","hardness 300 mg/l CaCO3 (Table 35-9's example)"],"cite":{"instrument":"us_oh_wqs","title":"Ohio Administrative Code Chapter 3745-1 Water Quality Standards: statewide aquatic life (Table 35-1, hardness and pH equations 35-9/35-10), wildlife (35-12), public water supply (33-1), agricultural supply (33-3), fish consumption (34-1), aesthetic (37-1) and Ohio river (32-1/32-2) criteria","issuer":"State of Ohio, Environmental Protection Agency","edition":"OAC 3745-1-01 to -44 and -50 to -54, effective March 16, 2026, as US EPA posts it in effect for CWA purposes (cover letter March 25, 2026: EPA disapproved, April 27, 2021, 44 lake Erie public water supply criteria of Table 33-1)","source_url":"https://www.epa.gov/sites/default/files/2015-09/documents/oh_34751_1_to_40.pdf","source_sha256":"129b8170e3fe705fd7b0be22d6ca7eb6bf37bfc003df0348bb42b8e67c60f9d0","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"OAC 3745-1-35 Table 35-9","page":481,"quote":"OMZM3 TR5 µg/l e(0.846 [ln H] + 2.255) 470 840 1200 1500"}},{"id":"da3bda06f7d87a83","parameter":"Nickel (total recoverable)","value":"1500","value_num":1500,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-02-0","place":["US-OH"],"conditions":["receiving_water is freshwater","hardness 400 mg/l CaCO3 or above (note 6: the 400 mg/l criteria are used above 400)"],"cite":{"instrument":"us_oh_wqs","title":"Ohio Administrative Code Chapter 3745-1 Water Quality Standards: statewide aquatic life (Table 35-1, hardness and pH equations 35-9/35-10), wildlife (35-12), public water supply (33-1), agricultural supply (33-3), fish consumption (34-1), aesthetic (37-1) and Ohio river (32-1/32-2) criteria","issuer":"State of Ohio, Environmental Protection Agency","edition":"OAC 3745-1-01 to -44 and -50 to -54, effective March 16, 2026, as US EPA posts it in effect for CWA purposes (cover letter March 25, 2026: EPA disapproved, April 27, 2021, 44 lake Erie public water supply criteria of Table 33-1)","source_url":"https://www.epa.gov/sites/default/files/2015-09/documents/oh_34751_1_to_40.pdf","source_sha256":"129b8170e3fe705fd7b0be22d6ca7eb6bf37bfc003df0348bb42b8e67c60f9d0","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"OAC 3745-1-35 Table 35-9","page":481,"quote":"OMZM3 TR5 µg/l e(0.846 [ln H] + 2.255) 470 840 1200 1500"}},{"id":"4e179d27892fc2e2","parameter":"Nickel (total recoverable)","value":"e(0.846 [ln H] + 0.0584)","unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-02-0","place":["US-OH"],"conditions":["receiving_water is freshwater","hardness-dependent: the row's equation of the receiving water's hardness (up to 400 mg/l CaCO3; above 400 the 400 value)"],"cite":{"instrument":"us_oh_wqs","title":"Ohio Administrative Code Chapter 3745-1 Water Quality Standards: statewide aquatic life (Table 35-1, hardness and pH equations 35-9/35-10), wildlife (35-12), public water supply (33-1), agricultural supply (33-3), fish consumption (34-1), aesthetic (37-1) and Ohio river (32-1/32-2) criteria","issuer":"State of Ohio, Environmental Protection Agency","edition":"OAC 3745-1-01 to -44 and -50 to -54, effective March 16, 2026, as US EPA posts it in effect for CWA purposes (cover letter March 25, 2026: EPA disapproved, April 27, 2021, 44 lake Erie public water supply criteria of Table 33-1)","source_url":"https://www.epa.gov/sites/default/files/2015-09/documents/oh_34751_1_to_40.pdf","source_sha256":"129b8170e3fe705fd7b0be22d6ca7eb6bf37bfc003df0348bb42b8e67c60f9d0","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"OAC 3745-1-35 Table 35-9","page":481,"quote":"OMZA3 TR5 µg/l e(0.846 [ln H] + 0.0584) 52 94 130 170"}},{"id":"2f590b5043105d74","parameter":"Nickel (total recoverable)","value":"52","value_num":52,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-02-0","place":["US-OH"],"conditions":["receiving_water is freshwater","hardness 100 mg/l CaCO3 (Table 35-9's example)"],"cite":{"instrument":"us_oh_wqs","title":"Ohio Administrative Code Chapter 3745-1 Water Quality Standards: statewide aquatic life (Table 35-1, hardness and pH equations 35-9/35-10), wildlife (35-12), public water supply (33-1), agricultural supply (33-3), fish consumption (34-1), aesthetic (37-1) and Ohio river (32-1/32-2) criteria","issuer":"State of Ohio, Environmental Protection Agency","edition":"OAC 3745-1-01 to -44 and -50 to -54, effective March 16, 2026, as US EPA posts it in effect for CWA purposes (cover letter March 25, 2026: EPA disapproved, April 27, 2021, 44 lake Erie public water supply criteria of Table 33-1)","source_url":"https://www.epa.gov/sites/default/files/2015-09/documents/oh_34751_1_to_40.pdf","source_sha256":"129b8170e3fe705fd7b0be22d6ca7eb6bf37bfc003df0348bb42b8e67c60f9d0","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"OAC 3745-1-35 Table 35-9","page":481,"quote":"OMZA3 TR5 µg/l e(0.846 [ln H] + 0.0584) 52 94 130 170"}},{"id":"b0757611eacd377b","parameter":"Nickel (total recoverable)","value":"94","value_num":94,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-02-0","place":["US-OH"],"conditions":["receiving_water is freshwater","hardness 200 mg/l CaCO3 (Table 35-9's example)"],"cite":{"instrument":"us_oh_wqs","title":"Ohio Administrative Code Chapter 3745-1 Water Quality Standards: statewide aquatic life (Table 35-1, hardness and pH equations 35-9/35-10), wildlife (35-12), public water supply (33-1), agricultural supply (33-3), fish consumption (34-1), aesthetic (37-1) and Ohio river (32-1/32-2) criteria","issuer":"State of Ohio, Environmental Protection Agency","edition":"OAC 3745-1-01 to -44 and -50 to -54, effective March 16, 2026, as US EPA posts it in effect for CWA purposes (cover letter March 25, 2026: EPA disapproved, April 27, 2021, 44 lake Erie public water supply criteria of Table 33-1)","source_url":"https://www.epa.gov/sites/default/files/2015-09/documents/oh_34751_1_to_40.pdf","source_sha256":"129b8170e3fe705fd7b0be22d6ca7eb6bf37bfc003df0348bb42b8e67c60f9d0","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"OAC 3745-1-35 Table 35-9","page":481,"quote":"OMZA3 TR5 µg/l e(0.846 [ln H] + 0.0584) 52 94 130 170"}},{"id":"552c41d4c40605ba","parameter":"Nickel (total recoverable)","value":"130","value_num":130,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-02-0","place":["US-OH"],"conditions":["receiving_water is freshwater","hardness 300 mg/l CaCO3 (Table 35-9's example)"],"cite":{"instrument":"us_oh_wqs","title":"Ohio Administrative Code Chapter 3745-1 Water Quality Standards: statewide aquatic life (Table 35-1, hardness and pH equations 35-9/35-10), wildlife (35-12), public water supply (33-1), agricultural supply (33-3), fish consumption (34-1), aesthetic (37-1) and Ohio river (32-1/32-2) criteria","issuer":"State of Ohio, Environmental Protection Agency","edition":"OAC 3745-1-01 to -44 and -50 to -54, effective March 16, 2026, as US EPA posts it in effect for CWA purposes (cover letter March 25, 2026: EPA disapproved, April 27, 2021, 44 lake Erie public water supply criteria of Table 33-1)","source_url":"https://www.epa.gov/sites/default/files/2015-09/documents/oh_34751_1_to_40.pdf","source_sha256":"129b8170e3fe705fd7b0be22d6ca7eb6bf37bfc003df0348bb42b8e67c60f9d0","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"OAC 3745-1-35 Table 35-9","page":481,"quote":"OMZA3 TR5 µg/l e(0.846 [ln H] + 0.0584) 52 94 130 170"}},{"id":"2a3bc9c3c2e6fa59","parameter":"Nickel (total recoverable)","value":"170","value_num":170,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-02-0","place":["US-OH"],"conditions":["receiving_water is freshwater","hardness 400 mg/l CaCO3 or above (note 6: the 400 mg/l criteria are used above 400)"],"cite":{"instrument":"us_oh_wqs","title":"Ohio Administrative Code Chapter 3745-1 Water Quality Standards: statewide aquatic life (Table 35-1, hardness and pH equations 35-9/35-10), wildlife (35-12), public water supply (33-1), agricultural supply (33-3), fish consumption (34-1), aesthetic (37-1) and Ohio river (32-1/32-2) criteria","issuer":"State of Ohio, Environmental Protection Agency","edition":"OAC 3745-1-01 to -44 and -50 to -54, effective March 16, 2026, as US EPA posts it in effect for CWA purposes (cover letter March 25, 2026: EPA disapproved, April 27, 2021, 44 lake Erie public water supply criteria of Table 33-1)","source_url":"https://www.epa.gov/sites/default/files/2015-09/documents/oh_34751_1_to_40.pdf","source_sha256":"129b8170e3fe705fd7b0be22d6ca7eb6bf37bfc003df0348bb42b8e67c60f9d0","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"OAC 3745-1-35 Table 35-9","page":481,"quote":"OMZA3 TR5 µg/l e(0.846 [ln H] + 0.0584) 52 94 130 170"}},{"id":"1482b65b26e737dc","parameter":"Nickel (total recoverable)","value":"610","value_num":610,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-02-0","place":["US-OH"],"conditions":["receiving_water is freshwater","water bodies within five hundred yards of drinking water intakes (OAC 3745-1-33(A)(1))","water bodies in the Ohio river drainage basin"],"cite":{"instrument":"us_oh_wqs","title":"Ohio Administrative Code Chapter 3745-1 Water Quality Standards: statewide aquatic life (Table 35-1, hardness and pH equations 35-9/35-10), wildlife (35-12), public water supply (33-1), agricultural supply (33-3), fish consumption (34-1), aesthetic (37-1) and Ohio river (32-1/32-2) criteria","issuer":"State of Ohio, Environmental Protection Agency","edition":"OAC 3745-1-01 to -44 and -50 to -54, effective March 16, 2026, as US EPA posts it in effect for CWA purposes (cover letter March 25, 2026: EPA disapproved, April 27, 2021, 44 lake Erie public water supply criteria of Table 33-1)","source_url":"https://www.epa.gov/sites/default/files/2015-09/documents/oh_34751_1_to_40.pdf","source_sha256":"129b8170e3fe705fd7b0be22d6ca7eb6bf37bfc003df0348bb42b8e67c60f9d0","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"OAC 3745-1-33 Table 33-1","page":459,"quote":"Nickel TR µg/l 610"}},{"id":"25ddffcba56e5f90","parameter":"Nickel (total recoverable)","value":"200","value_num":200,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-02-0","place":["US-OH"],"conditions":["receiving_water is freshwater","water bodies assigned the agricultural water supply use designation (OAC 3745-1-33(B)(2))"],"cite":{"instrument":"us_oh_wqs","title":"Ohio Administrative Code Chapter 3745-1 Water Quality Standards: statewide aquatic life (Table 35-1, hardness and pH equations 35-9/35-10), wildlife (35-12), public water supply (33-1), agricultural supply (33-3), fish consumption (34-1), aesthetic (37-1) and Ohio river (32-1/32-2) criteria","issuer":"State of Ohio, Environmental Protection Agency","edition":"OAC 3745-1-01 to -44 and -50 to -54, effective March 16, 2026, as US EPA posts it in effect for CWA purposes (cover letter March 25, 2026: EPA disapproved, April 27, 2021, 44 lake Erie public water supply criteria of Table 33-1)","source_url":"https://www.epa.gov/sites/default/files/2015-09/documents/oh_34751_1_to_40.pdf","source_sha256":"129b8170e3fe705fd7b0be22d6ca7eb6bf37bfc003df0348bb42b8e67c60f9d0","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"OAC 3745-1-33 Table 33-3","page":462,"quote":"Nickel TR µg/l 200"}},{"id":"b19574438d97506e","parameter":"Nickel (total recoverable)","value":"4,600","value_num":4600,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-02-0","place":["US-OH"],"conditions":["receiving_water is freshwater","water bodies in the Ohio river drainage basin"],"cite":{"instrument":"us_oh_wqs","title":"Ohio Administrative Code Chapter 3745-1 Water Quality Standards: statewide aquatic life (Table 35-1, hardness and pH equations 35-9/35-10), wildlife (35-12), public water supply (33-1), agricultural supply (33-3), fish consumption (34-1), aesthetic (37-1) and Ohio river (32-1/32-2) criteria","issuer":"State of Ohio, Environmental Protection Agency","edition":"OAC 3745-1-01 to -44 and -50 to -54, effective March 16, 2026, as US EPA posts it in effect for CWA purposes (cover letter March 25, 2026: EPA disapproved, April 27, 2021, 44 lake Erie public water supply criteria of Table 33-1)","source_url":"https://www.epa.gov/sites/default/files/2015-09/documents/oh_34751_1_to_40.pdf","source_sha256":"129b8170e3fe705fd7b0be22d6ca7eb6bf37bfc003df0348bb42b8e67c60f9d0","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"OAC 3745-1-34 Table 34-1","page":466,"quote":"Nickel TR µg/l 4,600 --"}},{"id":"9866cdc49954f840","parameter":"Nickel (total recoverable)","value":"610","value_num":610,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-02-0","place":["US-OH"],"conditions":["receiving_water is freshwater","the Ohio river mainstem (OAC 3745-1-32)","the Ohio river within five hundred yards of drinking water intakes (Table 32-2 note 3)"],"cite":{"instrument":"us_oh_wqs","title":"Ohio Administrative Code Chapter 3745-1 Water Quality Standards: statewide aquatic life (Table 35-1, hardness and pH equations 35-9/35-10), wildlife (35-12), public water supply (33-1), agricultural supply (33-3), fish consumption (34-1), aesthetic (37-1) and Ohio river (32-1/32-2) criteria","issuer":"State of Ohio, Environmental Protection Agency","edition":"OAC 3745-1-01 to -44 and -50 to -54, effective March 16, 2026, as US EPA posts it in effect for CWA purposes (cover letter March 25, 2026: EPA disapproved, April 27, 2021, 44 lake Erie public water supply criteria of Table 33-1)","source_url":"https://www.epa.gov/sites/default/files/2015-09/documents/oh_34751_1_to_40.pdf","source_sha256":"129b8170e3fe705fd7b0be22d6ca7eb6bf37bfc003df0348bb42b8e67c60f9d0","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"OAC 3745-1-32 Table 32-2","page":453,"quote":"Nickel TR µg/l 610 610"}},{"id":"3da40d98fc063b9b","parameter":"Nickel (total recoverable)","value":"610","value_num":610,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-02-0","place":["US-OH"],"conditions":["receiving_water is freshwater","the Ohio river mainstem (OAC 3745-1-32)","the Ohio river at all other locations (Table 32-2 note 3)"],"cite":{"instrument":"us_oh_wqs","title":"Ohio Administrative Code Chapter 3745-1 Water Quality Standards: statewide aquatic life (Table 35-1, hardness and pH equations 35-9/35-10), wildlife (35-12), public water supply (33-1), agricultural supply (33-3), fish consumption (34-1), aesthetic (37-1) and Ohio river (32-1/32-2) criteria","issuer":"State of Ohio, Environmental Protection Agency","edition":"OAC 3745-1-01 to -44 and -50 to -54, effective March 16, 2026, as US EPA posts it in effect for CWA purposes (cover letter March 25, 2026: EPA disapproved, April 27, 2021, 44 lake Erie public water supply criteria of Table 33-1)","source_url":"https://www.epa.gov/sites/default/files/2015-09/documents/oh_34751_1_to_40.pdf","source_sha256":"129b8170e3fe705fd7b0be22d6ca7eb6bf37bfc003df0348bb42b8e67c60f9d0","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"OAC 3745-1-32 Table 32-2","page":453,"quote":"Nickel TR µg/l 610 610"}},{"id":"dfd52c8ea54a53b2","parameter":"Nickel","value":"3.98","value_num":3.98,"unit":"mg/L","statistic":"composite","direction":"max","kind":"limit","medium":"product","level":"national","parameter_key":"cas:7440-02-0","place":["US"],"conditions":["(a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS."],"cite":{"instrument":"us_40cfr268_48","title":"40 CFR 268.48 — Universal treatment standards: Table UTS, wastewater and nonwastewater treatment standards for the hazardous constituents of land-disposal-restricted wastes","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"eCFR, 40 CFR 268.48 as of 2026-10-13 (title 40 up to date as of that day; source note: 59 FR 48103, Sept. 19, 1994, as last amended at 76 FR 34156, June 13, 2011)","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-13/title-40.xml?part=268&section=268.48","source_sha256":"70b2e58a6b1e228e2c204acc69b69fab0d5a0347e35d569959073c3dc3ee4adb","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 268.48, Table UTS, Inorganic Constituents, wastewater standard","page":null,"quote":"Nickel 7440-02-0 3.98 11 mg/l TCLP"}},{"id":"f0ba512ccced7861","parameter":"Nickel","value":"11 mg/l TCLP","value_num":11,"unit":"mg/L TCLP","statistic":"instant","direction":"max","kind":"limit","medium":"leachate","level":"national","parameter_key":"cas:7440-02-0","place":["US"],"conditions":["(a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS."],"cite":{"instrument":"us_40cfr268_48","title":"40 CFR 268.48 — Universal treatment standards: Table UTS, wastewater and nonwastewater treatment standards for the hazardous constituents of land-disposal-restricted wastes","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"eCFR, 40 CFR 268.48 as of 2026-10-13 (title 40 up to date as of that day; source note: 59 FR 48103, Sept. 19, 1994, as last amended at 76 FR 34156, June 13, 2011)","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-13/title-40.xml?part=268&section=268.48","source_sha256":"70b2e58a6b1e228e2c204acc69b69fab0d5a0347e35d569959073c3dc3ee4adb","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 268.48, Table UTS, Inorganic Constituents, nonwastewater standard","page":null,"quote":"Nickel 7440-02-0 3.98 11 mg/l TCLP"}},{"id":"e9e4b2e224ee4582","parameter":"Ni","value":"4.1","value_num":4.1,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-02-0","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Ni 4.1 2.6"}},{"id":"83d66936aa5ea4b0","parameter":"Ni","value":"2.6","value_num":2.6,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-02-0","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Ni 4.1 2.6"}},{"id":"3ef1d5e5c8e2c5eb","parameter":"Ni","value":"160","value_num":160,"unit":"mg/sq m-Operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-02-0","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may be applied in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Ni 160 100"}},{"id":"7160cf8b37b75373","parameter":"Ni","value":"100","value_num":100,"unit":"mg/sq m-Operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-02-0","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may be applied in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Ni 160 100"}},{"id":"d195b740acb82c9f","parameter":"Ni","value":"4.1","value_num":4.1,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-02-0","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Ni 4.1 2.6"}},{"id":"8d3bc58efb9b0dac","parameter":"Ni","value":"2.6","value_num":2.6,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-02-0","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Ni 4.1 2.6"}},{"id":"059272820af749ac","parameter":"Ni","value":"160","value_num":160,"unit":"mg/sq m-Operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-02-0","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Ni 160 100"}},{"id":"9495e70aca040bfa","parameter":"Ni","value":"100","value_num":100,"unit":"mg/sq m-Operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-02-0","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Ni 160 100"}},{"id":"fa70800dac350263","parameter":"Ni","value":"4.1","value_num":4.1,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-02-0","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart D—Anodizing Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.44 (PSES)","page":null,"quote":"Ni 4.1 2.6"}},{"id":"cdf6e5a239c167d1","parameter":"Ni","value":"2.6","value_num":2.6,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-02-0","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart D—Anodizing Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.44 (PSES)","page":null,"quote":"Ni 4.1 2.6"}},{"id":"46650ac4bafcafc2","parameter":"Ni","value":"160","value_num":160,"unit":"mg/sq m-operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-02-0","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart D—Anodizing Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.44 (PSES)","page":null,"quote":"Ni 160 100"}},{"id":"a0ae21aa2bd08ade","parameter":"Ni","value":"100","value_num":100,"unit":"mg/sq m-operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-02-0","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart D—Anodizing Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.44 (PSES)","page":null,"quote":"Ni 160 100"}},{"id":"ffff2fe16cd086c0","parameter":"Ni","value":"4.1","value_num":4.1,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-02-0","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart E—Coatings Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart E—Coatings Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.54 (PSES)","page":null,"quote":"Ni 4.1 2.6"}}],"next":[{"tool":"check_values","says":"Has your user measured this? check_values sets each of their results beside every row held here, with a verdict and the row's cite.","arguments":{"place":"US-OH"},"needs":{"rows":"Your user's measured results, as their table prints them: [{parameter: \"nickel\", value, unit}, ...], any other parameters too."},"post":"/api/v1/check"},{"tool":"read_certificate","says":"Has your user a laboratory certificate? read_certificate reads every row it prints, each with its page, and checks them against these limits.","arguments":{"place":"US-OH"},"needs":{"content_base64":"The laboratory's certificate (PDF) or its XLSX, XLS or CSV export, as base64; or file_url, a public https address of it."},"post":"/api/v1/certificate"}]}