{"query":{"parameter":"molybdenum","place":"US-PA","medium":null,"statistic":null,"kind":null},"searched":{"places":["US-PA","US"],"parameter_keys":["cas:7439-98-7","cas:27546-07-2","name:molybdenum-99","cas:68412-26-0","name:molybdenum - total"],"names_matched":[["molybdenum","cas:7439-98-7"],["ammonium molybdenum oxide nh4 2mo2o7","cas:27546-07-2"],["molybdenum 99","name:molybdenum-99"],["molybdenum bis dibutylcarbamodithioato di mu oxodioxodi sulfurized","cas:68412-26-0"],["molybdenum total","name:molybdenum - total"],["total molybdenum","name:molybdenum - total"]],"match":"exact+contains","order":"The place's own instruments first, then each place above it, each in its register's order"},"total":301,"offset":0,"returned":50,"next_offset":50,"rows":[{"id":"5ae5fb0f4f8cd07f","parameter":"MOLYBDENUM","value":"40","value_num":40,"unit":"µg/L","direction":"max","kind":"guideline","medium":"groundwater","level":"regional","parameter_key":"cas:7439-98-7","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","groundwater in an aquifer used or currently planned to be used for drinking water or agriculture, total dissolved solids 2,500 mg/L or less (25 Pa. Code §250.304(c))","residential standard"],"cite":{"instrument":"us_pa_act2_gw","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for groundwater, Appendix A Tables 1-2, as DEP publishes them, with the 2024 PFAS MSCs","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 1 November 2021, Table 2 November 2023; the PFAS MSCs effective June 25, 2024 (DEP, updated 7/10/2024); DEP's bromobenzene correction as its Statewide Health Standards page states it on 2026-10-15","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%201.pdf","source_sha256":"5bc985b6f8b3595b0684a060dbc14d170987bbc89a70737370e1887c3932b13c","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 2 - Medium-Specific Concentrations (MSCs) for Inorganic Regulated Substances in Groundwater (used aquifer, TDS ≤ 2500, R)","page":1,"quote":null}},{"id":"321994b7d8835297","parameter":"MOLYBDENUM","value":"40","value_num":40,"unit":"µg/L","direction":"max","kind":"guideline","medium":"groundwater","level":"regional","parameter_key":"cas:7439-98-7","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","groundwater in an aquifer used or currently planned to be used for drinking water or agriculture, total dissolved solids 2,500 mg/L or less (25 Pa. Code §250.304(c))","nonresidential standard"],"cite":{"instrument":"us_pa_act2_gw","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for groundwater, Appendix A Tables 1-2, as DEP publishes them, with the 2024 PFAS MSCs","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 1 November 2021, Table 2 November 2023; the PFAS MSCs effective June 25, 2024 (DEP, updated 7/10/2024); DEP's bromobenzene correction as its Statewide Health Standards page states it on 2026-10-15","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%201.pdf","source_sha256":"5bc985b6f8b3595b0684a060dbc14d170987bbc89a70737370e1887c3932b13c","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 2 - Medium-Specific Concentrations (MSCs) for Inorganic Regulated Substances in Groundwater (used aquifer, TDS ≤ 2500, NR)","page":1,"quote":null}},{"id":"3de6aa4e819206b6","parameter":"MOLYBDENUM","value":"4000","value_num":4000,"unit":"µg/L","direction":"max","kind":"guideline","medium":"groundwater","level":"regional","parameter_key":"cas:7439-98-7","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","groundwater in an aquifer used or currently planned to be used whose naturally occurring background total dissolved solids exceed 2,500 mg/L (§250.304(e))","residential standard"],"cite":{"instrument":"us_pa_act2_gw","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for groundwater, Appendix A Tables 1-2, as DEP publishes them, with the 2024 PFAS MSCs","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 1 November 2021, Table 2 November 2023; the PFAS MSCs effective June 25, 2024 (DEP, updated 7/10/2024); DEP's bromobenzene correction as its Statewide Health Standards page states it on 2026-10-15","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%201.pdf","source_sha256":"5bc985b6f8b3595b0684a060dbc14d170987bbc89a70737370e1887c3932b13c","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 2 - Medium-Specific Concentrations (MSCs) for Inorganic Regulated Substances in Groundwater (used aquifer, TDS > 2500, R)","page":1,"quote":null}},{"id":"82d6db63095c6572","parameter":"MOLYBDENUM","value":"4000","value_num":4000,"unit":"µg/L","direction":"max","kind":"guideline","medium":"groundwater","level":"regional","parameter_key":"cas:7439-98-7","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","groundwater in an aquifer used or currently planned to be used whose naturally occurring background total dissolved solids exceed 2,500 mg/L (§250.304(e))","nonresidential standard"],"cite":{"instrument":"us_pa_act2_gw","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for groundwater, Appendix A Tables 1-2, as DEP publishes them, with the 2024 PFAS MSCs","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 1 November 2021, Table 2 November 2023; the PFAS MSCs effective June 25, 2024 (DEP, updated 7/10/2024); DEP's bromobenzene correction as its Statewide Health Standards page states it on 2026-10-15","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%201.pdf","source_sha256":"5bc985b6f8b3595b0684a060dbc14d170987bbc89a70737370e1887c3932b13c","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 2 - Medium-Specific Concentrations (MSCs) for Inorganic Regulated Substances in Groundwater (used aquifer, TDS > 2500, NR)","page":1,"quote":null}},{"id":"3f17e90cdefb3792","parameter":"MOLYBDENUM","value":"40000","value_num":40000,"unit":"µg/L","direction":"max","kind":"guideline","medium":"groundwater","level":"regional","parameter_key":"cas:7439-98-7","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","groundwater in an aquifer not used or currently planned to be used (§250.304(d))","residential standard"],"cite":{"instrument":"us_pa_act2_gw","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for groundwater, Appendix A Tables 1-2, as DEP publishes them, with the 2024 PFAS MSCs","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 1 November 2021, Table 2 November 2023; the PFAS MSCs effective June 25, 2024 (DEP, updated 7/10/2024); DEP's bromobenzene correction as its Statewide Health Standards page states it on 2026-10-15","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%201.pdf","source_sha256":"5bc985b6f8b3595b0684a060dbc14d170987bbc89a70737370e1887c3932b13c","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 2 - Medium-Specific Concentrations (MSCs) for Inorganic Regulated Substances in Groundwater (nonuse aquifer, R)","page":1,"quote":null}},{"id":"8fa1285feb3696d8","parameter":"MOLYBDENUM","value":"40000","value_num":40000,"unit":"µg/L","direction":"max","kind":"guideline","medium":"groundwater","level":"regional","parameter_key":"cas:7439-98-7","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","groundwater in an aquifer not used or currently planned to be used (§250.304(d))","nonresidential standard"],"cite":{"instrument":"us_pa_act2_gw","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for groundwater, Appendix A Tables 1-2, as DEP publishes them, with the 2024 PFAS MSCs","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 1 November 2021, Table 2 November 2023; the PFAS MSCs effective June 25, 2024 (DEP, updated 7/10/2024); DEP's bromobenzene correction as its Statewide Health Standards page states it on 2026-10-15","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%201.pdf","source_sha256":"5bc985b6f8b3595b0684a060dbc14d170987bbc89a70737370e1887c3932b13c","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 2 - Medium-Specific Concentrations (MSCs) for Inorganic Regulated Substances in Groundwater (nonuse aquifer, NR)","page":1,"quote":null}},{"id":"5f5155032b1d9e02","parameter":"MOLYBDENUM","value":"1100","value_num":1100,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:7439-98-7","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a direct contact numeric value: the soil MSC is the lowest of it and the soil-to-groundwater numeric value, or it with a soil buffer or equivalency demonstration (§250.305(c)-(e))","residential, soil 0-15 feet from the existing ground surface (§250.305(c))"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, A. Direct Contact Numeric Values (R)","page":1,"quote":null}},{"id":"fc5b043bbd6e284f","parameter":"MOLYBDENUM","value":"16000","value_num":16000,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:7439-98-7","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a direct contact numeric value: the soil MSC is the lowest of it and the soil-to-groundwater numeric value, or it with a soil buffer or equivalency demonstration (§250.305(c)-(e))","nonresidential, surface soil 0-2 feet (§250.305(d))"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, A. Direct Contact Numeric Values (NR 0-2 ft)","page":1,"quote":null}},{"id":"83a9da4554640eda","parameter":"MOLYBDENUM","value":"190000","value_num":190000,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:7439-98-7","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a direct contact numeric value: the soil MSC is the lowest of it and the soil-to-groundwater numeric value, or it with a soil buffer or equivalency demonstration (§250.305(c)-(e))","nonresidential, subsurface soil 2-15 feet (§250.305(e))"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, A. Direct Contact Numeric Values (NR 2-15 ft)","page":1,"quote":null}},{"id":"f6e12af99d967471","parameter":"MOLYBDENUM","value":"4","value_num":4,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:7439-98-7","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))","the option 100 times the applicable groundwater MSC, expressed as mg/kg (§250.308(a)(1))","groundwater in an aquifer used or currently planned to be used for drinking water or agriculture, total dissolved solids 2,500 mg/L or less (25 Pa. Code §250.304(c))","residential standard"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (used aquifer, TDS ≤ 2500, R, 100 X GW MSC)","page":1,"quote":null}},{"id":"aff44eae1a4862bd","parameter":"MOLYBDENUM","value":"650","value_num":650,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:7439-98-7","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))","the generic value of the soil-to-groundwater equation, for soil not in the zone of groundwater saturation; in that zone the value is one tenth of it (§250.308(a)(2)-(4))","groundwater in an aquifer used or currently planned to be used for drinking water or agriculture, total dissolved solids 2,500 mg/L or less (25 Pa. Code §250.304(c))","residential standard"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (used aquifer, TDS ≤ 2500, R, Generic Value)","page":1,"quote":null}},{"id":"2dc2eda63f5b6d01","parameter":"MOLYBDENUM","value":"4","value_num":4,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:7439-98-7","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))","the option 100 times the applicable groundwater MSC, expressed as mg/kg (§250.308(a)(1))","groundwater in an aquifer used or currently planned to be used for drinking water or agriculture, total dissolved solids 2,500 mg/L or less (25 Pa. Code §250.304(c))","nonresidential standard"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (used aquifer, TDS ≤ 2500, NR, 100 X GW MSC)","page":1,"quote":null}},{"id":"f6595c249d1cb4ca","parameter":"MOLYBDENUM","value":"650","value_num":650,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:7439-98-7","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))","the generic value of the soil-to-groundwater equation, for soil not in the zone of groundwater saturation; in that zone the value is one tenth of it (§250.308(a)(2)-(4))","groundwater in an aquifer used or currently planned to be used for drinking water or agriculture, total dissolved solids 2,500 mg/L or less (25 Pa. Code §250.304(c))","nonresidential standard"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (used aquifer, TDS ≤ 2500, NR, Generic Value)","page":1,"quote":null}},{"id":"18435220a91325af","parameter":"MOLYBDENUM","value":"400","value_num":400,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:7439-98-7","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))","the option 100 times the applicable groundwater MSC, expressed as mg/kg (§250.308(a)(1))","groundwater in an aquifer used or currently planned to be used whose naturally occurring background total dissolved solids exceed 2,500 mg/L (§250.304(e))","residential standard"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (used aquifer, TDS > 2500, R, 100 X GW MSC)","page":1,"quote":null}},{"id":"56d1b12a252f5bfc","parameter":"MOLYBDENUM","value":"65000","value_num":65000,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:7439-98-7","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))","the generic value of the soil-to-groundwater equation, for soil not in the zone of groundwater saturation; in that zone the value is one tenth of it (§250.308(a)(2)-(4))","groundwater in an aquifer used or currently planned to be used whose naturally occurring background total dissolved solids exceed 2,500 mg/L (§250.304(e))","residential standard"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (used aquifer, TDS > 2500, R, Generic Value)","page":1,"quote":null}},{"id":"fca53b3f388be96e","parameter":"MOLYBDENUM","value":"400","value_num":400,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:7439-98-7","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))","the option 100 times the applicable groundwater MSC, expressed as mg/kg (§250.308(a)(1))","groundwater in an aquifer used or currently planned to be used whose naturally occurring background total dissolved solids exceed 2,500 mg/L (§250.304(e))","nonresidential standard"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (used aquifer, TDS > 2500, NR, 100 X GW MSC)","page":1,"quote":null}},{"id":"c9811387d056c47d","parameter":"MOLYBDENUM","value":"65000","value_num":65000,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:7439-98-7","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))","the generic value of the soil-to-groundwater equation, for soil not in the zone of groundwater saturation; in that zone the value is one tenth of it (§250.308(a)(2)-(4))","groundwater in an aquifer used or currently planned to be used whose naturally occurring background total dissolved solids exceed 2,500 mg/L (§250.304(e))","nonresidential standard"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (used aquifer, TDS > 2500, NR, Generic Value)","page":1,"quote":null}},{"id":"bce701457aa489ef","parameter":"MOLYBDENUM","value":"4000","value_num":4000,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:7439-98-7","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))","the option 100 times the applicable groundwater MSC, expressed as mg/kg (§250.308(a)(1))","groundwater in an aquifer not used or currently planned to be used (§250.304(d))","residential standard"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (nonuse aquifer, R, 100 X GW MSC)","page":1,"quote":null}},{"id":"619e05d906b454cb","parameter":"MOLYBDENUM","value":"190000","value_num":190000,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:7439-98-7","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))","the generic value of the soil-to-groundwater equation, for soil not in the zone of groundwater saturation; in that zone the value is one tenth of it (§250.308(a)(2)-(4))","groundwater in an aquifer not used or currently planned to be used (§250.304(d))","residential standard"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (nonuse aquifer, R, Generic Value)","page":1,"quote":null}},{"id":"fde21ea99d1f5888","parameter":"MOLYBDENUM","value":"4000","value_num":4000,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:7439-98-7","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))","the option 100 times the applicable groundwater MSC, expressed as mg/kg (§250.308(a)(1))","groundwater in an aquifer not used or currently planned to be used (§250.304(d))","nonresidential standard"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (nonuse aquifer, NR, 100 X GW MSC)","page":1,"quote":null}},{"id":"aec8ec4d65602157","parameter":"MOLYBDENUM","value":"190000","value_num":190000,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:7439-98-7","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))","the generic value of the soil-to-groundwater equation, for soil not in the zone of groundwater saturation; in that zone the value is one tenth of it (§250.308(a)(2)-(4))","groundwater in an aquifer not used or currently planned to be used (§250.304(d))","nonresidential standard"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (nonuse aquifer, NR, Generic Value)","page":1,"quote":null}},{"id":"0ae198264f91a888","parameter":"Molybdenum","value":"40.180","value_num":40.18,"unit":"mg/kg (pounds per million pounds of 100% sulfuric acid capacity","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-98-7","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart I—Metallurgical Acid Plants Subcategory","existing sources (BPT)","table: Subpart I—Metallurgical Acid Plant"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.92 (BPT)","page":null,"quote":"Molybdenum 1 40.180 20.790"}},{"id":"6c06de6b6775da16","parameter":"Molybdenum","value":"20.790","value_num":20.79,"unit":"mg/kg (pounds per million pounds of 100% sulfuric acid capacity","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-98-7","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart I—Metallurgical Acid Plants Subcategory","existing sources (BPT)","table: Subpart I—Metallurgical Acid Plant"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.92 (BPT)","page":null,"quote":"Molybdenum 1 40.180 20.790"}},{"id":"da78e901f6dfac5e","parameter":"Molybdenum","value":"0.000","value_num":0,"unit":"mg/kg (pounds per million pounds) of vanadium produced by decomposition","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-98-7","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart T—Secondary Molybdenum and Vanadium Subcategory","existing sources (BPT)","(c) Vanadium decomposition wet air pollution control.","table: BPT Limitations for the Secondary Molybdenum and Vanadium Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.222 (BPT)","page":null,"quote":"Molybdenum 0.000 0.000"}},{"id":"0fe3f568644c8ce6","parameter":"Molybdenum","value":"0.000","value_num":0,"unit":"mg/kg (pounds per million pounds) of vanadium produced by decomposition","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-98-7","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart T—Secondary Molybdenum and Vanadium Subcategory","existing sources (BPT)","(c) Vanadium decomposition wet air pollution control.","table: BPT Limitations for the Secondary Molybdenum and Vanadium Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.222 (BPT)","page":null,"quote":"Molybdenum 0.000 0.000"}},{"id":"94952aa6c1c63780","parameter":"Molybdenum","value":"0.000","value_num":0,"unit":"mg/kg (pounds per million pounds) of molybdenum produced","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-98-7","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart T—Secondary Molybdenum and Vanadium Subcategory","existing sources (BPT)","(d) Molybdenum drying wet air pollution control.","table: BPT Limitations for the Secondary Molybdenum and Vanadium Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.222 (BPT)","page":null,"quote":"Molybdenum 0.000 0.000"}},{"id":"9509612b136a023d","parameter":"Molybdenum","value":"0.000","value_num":0,"unit":"mg/kg (pounds per million pounds) of molybdenum produced","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-98-7","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart T—Secondary Molybdenum and Vanadium Subcategory","existing sources (BPT)","(d) Molybdenum drying wet air pollution control.","table: BPT Limitations for the Secondary Molybdenum and Vanadium Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.222 (BPT)","page":null,"quote":"Molybdenum 0.000 0.000"}},{"id":"c5ebef23d3ec5fd5","parameter":"Molybdenum","value":"0.000","value_num":0,"unit":"mg/kg (pounds per million pounds) of vanadium produced by decomposition","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-98-7","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart T—Secondary Molybdenum and Vanadium Subcategory","existing sources (BAT)","(c) Vanadium decomposition wet air pollution control.","table: BAT Limitations for the Secondary Molybdenum and Vanadium Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.223 (BAT)","page":null,"quote":"Molybdenum 0.000 0.000"}},{"id":"3b8aea53bb383a4b","parameter":"Molybdenum","value":"0.000","value_num":0,"unit":"mg/kg (pounds per million pounds) of vanadium produced by decomposition","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-98-7","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart T—Secondary Molybdenum and Vanadium Subcategory","existing sources (BAT)","(c) Vanadium decomposition wet air pollution control.","table: BAT Limitations for the Secondary Molybdenum and Vanadium Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.223 (BAT)","page":null,"quote":"Molybdenum 0.000 0.000"}},{"id":"3f6a9d910e980b27","parameter":"Molybdenum","value":"0.000","value_num":0,"unit":"mg/kg (pounds per million pounds) of molybdenum produced","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-98-7","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart T—Secondary Molybdenum and Vanadium Subcategory","existing sources (BAT)","(d) Molybdenum drying wet air pollution control.","table: BAT Limitations for the Secondary Molybdenum and Vanadium Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.223 (BAT)","page":null,"quote":"Molybdenum 0.000 0.000"}},{"id":"4424781af854f73d","parameter":"Molybdenum","value":"0.000","value_num":0,"unit":"mg/kg (pounds per million pounds) of molybdenum produced","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-98-7","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart T—Secondary Molybdenum and Vanadium Subcategory","existing sources (BAT)","(d) Molybdenum drying wet air pollution control.","table: BAT Limitations for the Secondary Molybdenum and Vanadium Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.223 (BAT)","page":null,"quote":"Molybdenum 0.000 0.000"}},{"id":"ff26fc41d36121de","parameter":"Molybdenum","value":"0.000","value_num":0,"unit":"mg/kg (pounds per million pounds) of molybdenum and vanadium produced","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-98-7","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart T—Secondary Molybdenum and Vanadium Subcategory","new sources (NSPS)","(c) Vanadium decomposition wet air pollution control.","table: NSPS for the Secondary Molybdenum and Vanadium Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.224 (NSPS)","page":null,"quote":"Molybdenum 0.000 0.000"}},{"id":"137a1e1828e6c247","parameter":"Molybdenum","value":"0.000","value_num":0,"unit":"mg/kg (pounds per million pounds) of molybdenum and vanadium produced","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-98-7","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart T—Secondary Molybdenum and Vanadium Subcategory","new sources (NSPS)","(c) Vanadium decomposition wet air pollution control.","table: NSPS for the Secondary Molybdenum and Vanadium Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.224 (NSPS)","page":null,"quote":"Molybdenum 0.000 0.000"}},{"id":"ce0efec8f0bbe2ad","parameter":"Molybdenum","value":"0.000","value_num":0,"unit":"mg/kg (pounds per million pounds) of molybdenum and vanadium produced","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-98-7","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart T—Secondary Molybdenum and Vanadium Subcategory","new sources (NSPS)","(d) Molybdenum drying wet air pollution control.","table: NSPS for the Secondary Molybdenum and Vanadium Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.224 (NSPS)","page":null,"quote":"Molybdenum 0.000 0.000"}},{"id":"70a9516e2a47c333","parameter":"Molybdenum","value":"0.000","value_num":0,"unit":"mg/kg (pounds per million pounds) of molybdenum and vanadium produced","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-98-7","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart T—Secondary Molybdenum and Vanadium Subcategory","new sources (NSPS)","(d) Molybdenum drying wet air pollution control.","table: NSPS for the Secondary Molybdenum and Vanadium Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.224 (NSPS)","page":null,"quote":"Molybdenum 0.000 0.000"}},{"id":"18baa6eef53e991e","parameter":"Molybdenum","value":"0.000","value_num":0,"unit":"mg/kg (pounds per million pounds) vanadium produced by decomposition","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7439-98-7","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart T—Secondary Molybdenum and Vanadium Subcategory","new sources (PSNS)","(c) Vanadium decomposition wet air pollution control.","table: PSNS for the Secondary Molybdenum and Vandadium Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.226 (PSNS)","page":null,"quote":"Molybdenum 0.000 0.000"}},{"id":"ad7cd591e827af66","parameter":"Molybdenum","value":"0.000","value_num":0,"unit":"mg/kg (pounds per million pounds) vanadium produced by decomposition","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7439-98-7","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart T—Secondary Molybdenum and Vanadium Subcategory","new sources (PSNS)","(c) Vanadium decomposition wet air pollution control.","table: PSNS for the Secondary Molybdenum and Vandadium Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.226 (PSNS)","page":null,"quote":"Molybdenum 0.000 0.000"}},{"id":"f39ab8e9b076aad2","parameter":"Molybdenum","value":"0.000","value_num":0,"unit":"mg/kg (pounds per million pounds) of molybdenum produced","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7439-98-7","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart T—Secondary Molybdenum and Vanadium Subcategory","new sources (PSNS)","(d) Molybdenum drying wet air pollution control.","table: PSNS for the Secondary Molybdenum and Vandadium Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.226 (PSNS)","page":null,"quote":"Molybdenum 0.000 0.000"}},{"id":"bd53ae5e5923f492","parameter":"Molybdenum","value":"0.000","value_num":0,"unit":"mg/kg (pounds per million pounds) of molybdenum produced","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7439-98-7","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart T—Secondary Molybdenum and Vanadium Subcategory","new sources (PSNS)","(d) Molybdenum drying wet air pollution control.","table: PSNS for the Secondary Molybdenum and Vandadium Subcategory"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.226 (PSNS)","page":null,"quote":"Molybdenum 0.000 0.000"}},{"id":"d6df2c38f5c8c734","parameter":"Molybdenum","value":"2.84","value_num":2.84,"unit":"mg/off-kg (pounds per million off-pounds) of refractory metals rolled with emulsions","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-98-7","place":["US"],"conditions":["route is direct","cites is 40 CFR 471","the discharge is of the Subpart E—Refractory Metals Forming Subcategory","existing sources (BPT)","(b) Rolling spent emulsions.","table: Subpart E—BPT"],"cite":{"instrument":"us_40cfr471","title":"40 CFR Part 471 — PART 471—NONFERROUS METALS FORMING AND METAL POWDERS POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=471","source_sha256":"2133233aad39c4df1dfd22825d228cb8ca25365a51aadadb9aacb46241c2ceea","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 471.51 (BPT)","page":null,"quote":"Molybdenum 2.84 1.47"}},{"id":"189e9440c2516e9d","parameter":"Molybdenum","value":"1.47","value_num":1.47,"unit":"mg/off-kg (pounds per million off-pounds) of refractory metals rolled with emulsions","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-98-7","place":["US"],"conditions":["route is direct","cites is 40 CFR 471","the discharge is of the Subpart E—Refractory Metals Forming Subcategory","existing sources (BPT)","(b) Rolling spent emulsions.","table: Subpart E—BPT"],"cite":{"instrument":"us_40cfr471","title":"40 CFR Part 471 — PART 471—NONFERROUS METALS FORMING AND METAL POWDERS POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=471","source_sha256":"2133233aad39c4df1dfd22825d228cb8ca25365a51aadadb9aacb46241c2ceea","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 471.51 (BPT)","page":null,"quote":"Molybdenum 2.84 1.47"}},{"id":"16cd33a4a2e68294","parameter":"Molybdenum","value":"7.87","value_num":7.87,"unit":"mg/off-kg (pounds per million off-pounds) of refractory metals extruded","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-98-7","place":["US"],"conditions":["route is direct","cites is 40 CFR 471","the discharge is of the Subpart E—Refractory Metals Forming Subcategory","existing sources (BPT)","(e) Extrusion press hydraulic fluid leakage.","table: Subpart E—BPT"],"cite":{"instrument":"us_40cfr471","title":"40 CFR Part 471 — PART 471—NONFERROUS METALS FORMING AND METAL POWDERS POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=471","source_sha256":"2133233aad39c4df1dfd22825d228cb8ca25365a51aadadb9aacb46241c2ceea","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 471.51 (BPT)","page":null,"quote":"Molybdenum 7.87 4.07"}},{"id":"b1e441c6fdd478a1","parameter":"Molybdenum","value":"4.07","value_num":4.07,"unit":"mg/off-kg (pounds per million off-pounds) of refractory metals extruded","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-98-7","place":["US"],"conditions":["route is direct","cites is 40 CFR 471","the discharge is of the Subpart E—Refractory Metals Forming Subcategory","existing sources (BPT)","(e) Extrusion press hydraulic fluid leakage.","table: Subpart E—BPT"],"cite":{"instrument":"us_40cfr471","title":"40 CFR Part 471 — PART 471—NONFERROUS METALS FORMING AND METAL POWDERS POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=471","source_sha256":"2133233aad39c4df1dfd22825d228cb8ca25365a51aadadb9aacb46241c2ceea","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 471.51 (BPT)","page":null,"quote":"Molybdenum 7.87 4.07"}},{"id":"dd888aa2a06ac7a3","parameter":"Molybdenum","value":"2.14","value_num":2.14,"unit":"mg/off-kg (pounds per million off-pounds) of forged refractory metals cooled with water","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-98-7","place":["US"],"conditions":["route is direct","cites is 40 CFR 471","the discharge is of the Subpart E—Refractory Metals Forming Subcategory","existing sources (BPT)","(g) Forging contact cooling water.","table: Subpart E—BPT"],"cite":{"instrument":"us_40cfr471","title":"40 CFR Part 471 — PART 471—NONFERROUS METALS FORMING AND METAL POWDERS POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=471","source_sha256":"2133233aad39c4df1dfd22825d228cb8ca25365a51aadadb9aacb46241c2ceea","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 471.51 (BPT)","page":null,"quote":"Molybdenum 2.14 1.11"}},{"id":"ae9874f7585a2e34","parameter":"Molybdenum","value":"1.11","value_num":1.11,"unit":"mg/off-kg (pounds per million off-pounds) of forged refractory metals cooled with water","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-98-7","place":["US"],"conditions":["route is direct","cites is 40 CFR 471","the discharge is of the Subpart E—Refractory Metals Forming Subcategory","existing sources (BPT)","(g) Forging contact cooling water.","table: Subpart E—BPT"],"cite":{"instrument":"us_40cfr471","title":"40 CFR Part 471 — PART 471—NONFERROUS METALS FORMING AND METAL POWDERS POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=471","source_sha256":"2133233aad39c4df1dfd22825d228cb8ca25365a51aadadb9aacb46241c2ceea","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 471.51 (BPT)","page":null,"quote":"Molybdenum 2.14 1.11"}},{"id":"6b4092748dcc7ee6","parameter":"Molybdenum","value":"8.99","value_num":8.99,"unit":"mg/off-kg (pounds per million off-pounds) of refractory metals formed","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-98-7","place":["US"],"conditions":["route is direct","cites is 40 CFR 471","the discharge is of the Subpart E—Refractory Metals Forming Subcategory","existing sources (BPT)","(h) Equipment cleaning wastewater.","table: Subpart E—BPT"],"cite":{"instrument":"us_40cfr471","title":"40 CFR Part 471 — PART 471—NONFERROUS METALS FORMING AND METAL POWDERS POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=471","source_sha256":"2133233aad39c4df1dfd22825d228cb8ca25365a51aadadb9aacb46241c2ceea","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 471.51 (BPT)","page":null,"quote":"Molybdenum 8.99 4.65"}},{"id":"ba610fcac59d283e","parameter":"Molybdenum","value":"4.65","value_num":4.65,"unit":"mg/off-kg (pounds per million off-pounds) of refractory metals formed","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-98-7","place":["US"],"conditions":["route is direct","cites is 40 CFR 471","the discharge is of the Subpart E—Refractory Metals Forming Subcategory","existing sources (BPT)","(h) Equipment cleaning wastewater.","table: Subpart E—BPT"],"cite":{"instrument":"us_40cfr471","title":"40 CFR Part 471 — PART 471—NONFERROUS METALS FORMING AND METAL POWDERS POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=471","source_sha256":"2133233aad39c4df1dfd22825d228cb8ca25365a51aadadb9aacb46241c2ceea","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 471.51 (BPT)","page":null,"quote":"Molybdenum 8.99 4.65"}},{"id":"76431471e5356ec6","parameter":"Molybdenum","value":"1.86","value_num":1.86,"unit":"mg/off-kg (pounds per million off-pounds) of refractory metals powder produced","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-98-7","place":["US"],"conditions":["route is direct","cites is 40 CFR 471","the discharge is of the Subpart E—Refractory Metals Forming Subcategory","existing sources (BPT)","(i) Metal powder production wastewater.","table: Subpart E—BPT"],"cite":{"instrument":"us_40cfr471","title":"40 CFR Part 471 — PART 471—NONFERROUS METALS FORMING AND METAL POWDERS POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=471","source_sha256":"2133233aad39c4df1dfd22825d228cb8ca25365a51aadadb9aacb46241c2ceea","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 471.51 (BPT)","page":null,"quote":"Molybdenum 1.86 0.961"}},{"id":"0f78061b1ea81906","parameter":"Molybdenum","value":"0.961","value_num":0.961,"unit":"mg/off-kg (pounds per million off-pounds) of refractory metals powder produced","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-98-7","place":["US"],"conditions":["route is direct","cites is 40 CFR 471","the discharge is of the Subpart E—Refractory Metals Forming Subcategory","existing sources (BPT)","(i) Metal powder production wastewater.","table: Subpart E—BPT"],"cite":{"instrument":"us_40cfr471","title":"40 CFR Part 471 — PART 471—NONFERROUS METALS FORMING AND METAL POWDERS POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=471","source_sha256":"2133233aad39c4df1dfd22825d228cb8ca25365a51aadadb9aacb46241c2ceea","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 471.51 (BPT)","page":null,"quote":"Molybdenum 1.86 0.961"}},{"id":"492712cf0137d602","parameter":"Molybdenum","value":"2.57","value_num":2.57,"unit":"mg/off-kg (pounds per million off-pounds) of refractory metals surface treated","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-98-7","place":["US"],"conditions":["route is direct","cites is 40 CFR 471","the discharge is of the Subpart E—Refractory Metals Forming Subcategory","existing sources (BPT)","(l) Surface treatment spent baths.","table: Subpart E—BPT"],"cite":{"instrument":"us_40cfr471","title":"40 CFR Part 471 — PART 471—NONFERROUS METALS FORMING AND METAL POWDERS POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=471","source_sha256":"2133233aad39c4df1dfd22825d228cb8ca25365a51aadadb9aacb46241c2ceea","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 471.51 (BPT)","page":null,"quote":"Molybdenum 2.57 1.33"}}],"next":[{"tool":"check_values","says":"Has your user measured this? check_values sets each of their results beside every row held here, with a verdict and the row's cite.","arguments":{"place":"US-PA"},"needs":{"rows":"Your user's measured results, as their table prints them: [{parameter: \"molybdenum\", value, unit}, ...], any other parameters too."},"post":"/api/v1/check","url":"https://passage-data.com/api/v1/check","page":"https://passage-data.com/limits/US-PA/molybdenum#check"},{"tool":"read_certificate","says":"Has your user a laboratory certificate? read_certificate reads every row it prints, each with its page, and checks them against these limits.","arguments":{"place":"US-PA"},"needs":{"content_base64":"The laboratory's certificate (PDF) or its XLSX, XLS or CSV export, as base64; or file_url, a public https address of it."},"post":"/api/v1/certificate","url":"https://passage-data.com/api/v1/certificate","page":"https://passage-data.com/limits/US-PA/molybdenum#check"}]}