{"query":{"parameter":"manganese","place":"US-FL","medium":null,"statistic":null,"kind":null},"searched":{"places":["US-FL","US"],"parameter_keys":["cas:7439-96-5","name:manganese-54","name:manganese total"],"names_matched":[["manganese","cas:7439-96-5"],["manganese 54","name:manganese-54"],["manganese total","name:manganese total"]],"match":"exact+contains","order":"The place's own instruments first, then each place above it, each in its register's order"},"total":177,"offset":0,"returned":50,"next_offset":50,"rows":[{"id":"f2024325ec4ccb15","parameter":"Manganese","value":"50","value_num":50,"unit":"µg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:7439-96-5","place":["US-FL"],"conditions":["groundwater (Table I, Groundwater Criteria column)","Note: If more than one contaminant is present at a site, CTLs are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Figure 10 of the February 2005 'Final Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.' However, GCTLs for primary and secondary standards shall not be modified."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","section":"Ch. 62-777 F.A.C. Table I, Groundwater and Surface Water Cleanup Target Levels, Groundwater Criteria (DEP spreadsheet, sheet TTable1, row 328)","page":null,"quote":"row 328: Manganese | 50 |  |  | 500 | -Neurological  | 7439-96-5 |  | Secondary Standard | NA | NA |  | Aesthetic"}},{"id":"51e49a0088107b65","parameter":"Manganese","value":"500","value_num":500,"unit":"µg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:7439-96-5","place":["US-FL"],"conditions":["groundwater of low yield/poor quality (Table I, Groundwater of Low Yield/Poor Quality Criteria column)","Note: If more than one contaminant is present at a site, CTLs are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Figure 10 of the February 2005 'Final Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.' However, GCTLs for primary and secondary standards shall not be modified."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","section":"Ch. 62-777 F.A.C. Table I, Groundwater and Surface Water Cleanup Target Levels, Groundwater of Low Yield/Poor Quality Criteria (DEP spreadsheet, sheet TTable1, row 328)","page":null,"quote":"row 328: Manganese | 50 |  |  | 500 | -Neurological  | 7439-96-5 |  | Secondary Standard | NA | NA |  | Aesthetic"}},{"id":"5a8bdb8dc90bb8d5","parameter":"Manganese","value":"3500","value_num":3500,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7439-96-5","place":["US-FL"],"conditions":["residential direct exposure (Table II, Direct Exposure - Residential column)","Note: If more than one contaminant is present at a site, the direct exposure values are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Appendix D 'Draft Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.', dated February 2005."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","section":"Ch. 62-777 F.A.C. Table II, Soil Cleanup Target Levels, Direct Exposure - Residential (DEP spreadsheet, sheet TTable2, row 299)","page":null,"quote":"row 299: Manganese | -Neurological  | 7439-96-5 | 3500 | 43000 | *** | NA | NA | ***"}},{"id":"0f0c9701e34f387b","parameter":"Manganese","value":"43000","value_num":43000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7439-96-5","place":["US-FL"],"conditions":["industrial direct exposure (Table II, Direct Exposure - Industrial column)","Note: If more than one contaminant is present at a site, the direct exposure values are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Appendix D 'Draft Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.', dated February 2005."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","section":"Ch. 62-777 F.A.C. Table II, Soil Cleanup Target Levels, Direct Exposure - Industrial (DEP spreadsheet, sheet TTable2, row 299)","page":null,"quote":"row 299: Manganese | -Neurological  | 7439-96-5 | 3500 | 43000 | *** | NA | NA | ***"}},{"id":"3c95cad423618b2a","parameter":"Manganese","value":"< 0.1","value_num":0.1,"unit":"mg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7439-96-5","place":["US-FL"],"conditions":["receiving_water is marine","Class II, shellfish propagation or harvesting (waters listed by name in 62-302.400, F.A.C.)"],"cite":{"instrument":"us_fl_wqs","title":"F.A.C. 62-302.530 Table: Surface Water Quality Criteria (Florida) — Class I, II, III fresh, III marine and IV criteria","issuer":"State of Florida, Department of Environmental Protection (Environmental Regulation Commission)","edition":"Chapter 62-302, F.A.C., as US EPA posts it in effect for Clean Water Act purposes; 62-302.530 amended through 11-25-25 (its history note, p. 45); EPA's re-posting of 2026-10-05 (PDF CreationDate), fetched 2026-10-15","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/fl_section62-302.pdf","source_sha256":"9865f1a6486a9332278c619fbcd71dc9f4f19af10e39576eea8ae900136aa284","fetched_at":"2026-10-15","section":"F.A.C. 62-302.530(40)","page":37,"quote":null}},{"id":"2cbc349316fd282e","parameter":"Manganese","value":"2.771","value_num":2.771,"unit":"kg/kkg of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 424","the discharge is of the Subpart F—Electrolytic Manganese Products Subcategory","existing sources (BPT)","(a) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section which may be discharged by a point source subject to the provisions of this subpart producing electrolytic manganese after application of the best practicable control technology currently available:"],"cite":{"instrument":"us_40cfr424","title":"40 CFR Part 424 — PART 424—FERROALLOY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=424","source_sha256":"b9ba02c4f274d6907407c320e0fcce140e72aa79cf2e81ae80ae804f723e7bed","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 424.62 (BPT)","page":null,"quote":"Manganese 2.771 1.356"}},{"id":"2a24a7b45e75a79a","parameter":"Manganese","value":"1.356","value_num":1.356,"unit":"kg/kkg of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 424","the discharge is of the Subpart F—Electrolytic Manganese Products Subcategory","existing sources (BPT)","(a) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section which may be discharged by a point source subject to the provisions of this subpart producing electrolytic manganese after application of the best practicable control technology currently available:"],"cite":{"instrument":"us_40cfr424","title":"40 CFR Part 424 — PART 424—FERROALLOY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=424","source_sha256":"b9ba02c4f274d6907407c320e0fcce140e72aa79cf2e81ae80ae804f723e7bed","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 424.62 (BPT)","page":null,"quote":"Manganese 2.771 1.356"}},{"id":"8eed093e42a27f89","parameter":"Manganese","value":"0.705","value_num":0.705,"unit":"kg/kkg of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 424","the discharge is of the Subpart F—Electrolytic Manganese Products Subcategory","existing sources (BPT)","(b) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart producing electrolytic manganese dioxide after application of the best practicable control technology currently available:"],"cite":{"instrument":"us_40cfr424","title":"40 CFR Part 424 — PART 424—FERROALLOY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=424","source_sha256":"b9ba02c4f274d6907407c320e0fcce140e72aa79cf2e81ae80ae804f723e7bed","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 424.62 (BPT)","page":null,"quote":"Manganese 0.705 .352"}},{"id":"d9706833dddeaaa6","parameter":"Manganese","value":".352","value_num":0.352,"unit":"kg/kkg of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 424","the discharge is of the Subpart F—Electrolytic Manganese Products Subcategory","existing sources (BPT)","(b) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart producing electrolytic manganese dioxide after application of the best practicable control technology currently available:"],"cite":{"instrument":"us_40cfr424","title":"40 CFR Part 424 — PART 424—FERROALLOY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=424","source_sha256":"b9ba02c4f274d6907407c320e0fcce140e72aa79cf2e81ae80ae804f723e7bed","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 424.62 (BPT)","page":null,"quote":"Manganese 0.705 .352"}},{"id":"f0d322e251085023","parameter":"Manganese","value":"0.678","value_num":0.678,"unit":"kg/kkg of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 424","the discharge is of the Subpart F—Electrolytic Manganese Products Subcategory","existing sources (BAT)","(a) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart producing electrolytic manganese after application of the best available technology economically achievable:"],"cite":{"instrument":"us_40cfr424","title":"40 CFR Part 424 — PART 424—FERROALLOY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=424","source_sha256":"b9ba02c4f274d6907407c320e0fcce140e72aa79cf2e81ae80ae804f723e7bed","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 424.63 (BAT)","page":null,"quote":"Manganese 0.678 0.339"}},{"id":"59bedeb6c5b7bf17","parameter":"Manganese","value":"0.339","value_num":0.339,"unit":"kg/kkg of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 424","the discharge is of the Subpart F—Electrolytic Manganese Products Subcategory","existing sources (BAT)","(a) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart producing electrolytic manganese after application of the best available technology economically achievable:"],"cite":{"instrument":"us_40cfr424","title":"40 CFR Part 424 — PART 424—FERROALLOY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=424","source_sha256":"b9ba02c4f274d6907407c320e0fcce140e72aa79cf2e81ae80ae804f723e7bed","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 424.63 (BAT)","page":null,"quote":"Manganese 0.678 0.339"}},{"id":"ea29287299f02ceb","parameter":"Manganese","value":"0.176","value_num":0.176,"unit":"kg/kkg of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 424","the discharge is of the Subpart F—Electrolytic Manganese Products Subcategory","existing sources (BAT)","(b) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart producing electrolytic manganese dioxide after application of the best available technology economically achievable:"],"cite":{"instrument":"us_40cfr424","title":"40 CFR Part 424 — PART 424—FERROALLOY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=424","source_sha256":"b9ba02c4f274d6907407c320e0fcce140e72aa79cf2e81ae80ae804f723e7bed","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 424.63 (BAT)","page":null,"quote":"Manganese 0.176 0.088"}},{"id":"e1230a8e8f90776b","parameter":"Manganese","value":"0.088","value_num":0.088,"unit":"kg/kkg of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 424","the discharge is of the Subpart F—Electrolytic Manganese Products Subcategory","existing sources (BAT)","(b) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart producing electrolytic manganese dioxide after application of the best available technology economically achievable:"],"cite":{"instrument":"us_40cfr424","title":"40 CFR Part 424 — PART 424—FERROALLOY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=424","source_sha256":"b9ba02c4f274d6907407c320e0fcce140e72aa79cf2e81ae80ae804f723e7bed","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 424.63 (BAT)","page":null,"quote":"Manganese 0.176 0.088"}},{"id":"fa01427618d73665","parameter":"Manganese","value":"2.111","value_num":2.111,"unit":"kg/kkg of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 424","the discharge is of the Subpart G—Electrolytic Chromium Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr424","title":"40 CFR Part 424 — PART 424—FERROALLOY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=424","source_sha256":"b9ba02c4f274d6907407c320e0fcce140e72aa79cf2e81ae80ae804f723e7bed","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 424.72 (BPT)","page":null,"quote":"Manganese 2.111 1.055"}},{"id":"bb912991958f9e75","parameter":"Manganese","value":"1.055","value_num":1.055,"unit":"kg/kkg of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 424","the discharge is of the Subpart G—Electrolytic Chromium Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr424","title":"40 CFR Part 424 — PART 424—FERROALLOY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=424","source_sha256":"b9ba02c4f274d6907407c320e0fcce140e72aa79cf2e81ae80ae804f723e7bed","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 424.72 (BPT)","page":null,"quote":"Manganese 2.111 1.055"}},{"id":"ec97191ff2cfa289","parameter":"Manganese","value":"0.530","value_num":0.53,"unit":"kg/kkg of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 424","the discharge is of the Subpart G—Electrolytic Chromium Subcategory","existing sources (BAT)","The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable:"],"cite":{"instrument":"us_40cfr424","title":"40 CFR Part 424 — PART 424—FERROALLOY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=424","source_sha256":"b9ba02c4f274d6907407c320e0fcce140e72aa79cf2e81ae80ae804f723e7bed","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 424.73 (BAT)","page":null,"quote":"Manganese 0.530 0.265"}},{"id":"c1a8c108e1481729","parameter":"Manganese","value":"0.265","value_num":0.265,"unit":"kg/kkg of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 424","the discharge is of the Subpart G—Electrolytic Chromium Subcategory","existing sources (BAT)","The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable:"],"cite":{"instrument":"us_40cfr424","title":"40 CFR Part 424 — PART 424—FERROALLOY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=424","source_sha256":"b9ba02c4f274d6907407c320e0fcce140e72aa79cf2e81ae80ae804f723e7bed","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 424.73 (BAT)","page":null,"quote":"Manganese 0.530 0.265"}},{"id":"7949debf714fe68e","parameter":"Manganese, total","value":"4.0","value_num":4,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 434","the discharge is of the Subpart B—Coal Preparation Plants and Coal Preparation Plant Associated Areas","existing sources (BPT)","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr434","title":"40 CFR Part 434 — PART 434—COAL MINING POINT SOURCE CATEGORY BPT, BAT, BCT LIMITATIONS AND NEW SOURCE PERFORMANCE STANDARDS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=434","source_sha256":"59437ebfad1a7c3090dc8f3f11eac33d1cfa8c81e44baf92b3fcbfc75b584c19","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 434.22 (BPT)","page":null,"quote":"Manganese, total 4.0 2.0"}},{"id":"85ffb05765609e0e","parameter":"Manganese, total","value":"2.0","value_num":2,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 434","the discharge is of the Subpart B—Coal Preparation Plants and Coal Preparation Plant Associated Areas","existing sources (BPT)","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr434","title":"40 CFR Part 434 — PART 434—COAL MINING POINT SOURCE CATEGORY BPT, BAT, BCT LIMITATIONS AND NEW SOURCE PERFORMANCE STANDARDS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=434","source_sha256":"59437ebfad1a7c3090dc8f3f11eac33d1cfa8c81e44baf92b3fcbfc75b584c19","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 434.22 (BPT)","page":null,"quote":"Manganese, total 4.0 2.0"}},{"id":"f4a1f3eab53007f6","parameter":"Manganese, total","value":"4.0","value_num":4,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 434","the discharge is of the Subpart B—Coal Preparation Plants and Coal Preparation Plant Associated Areas","existing sources (BAT)","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr434","title":"40 CFR Part 434 — PART 434—COAL MINING POINT SOURCE CATEGORY BPT, BAT, BCT LIMITATIONS AND NEW SOURCE PERFORMANCE STANDARDS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=434","source_sha256":"59437ebfad1a7c3090dc8f3f11eac33d1cfa8c81e44baf92b3fcbfc75b584c19","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 434.23 (BAT)","page":null,"quote":"Manganese, total 4.0 2.0"}},{"id":"5e30f6040d05a2ac","parameter":"Manganese, total","value":"2.0","value_num":2,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 434","the discharge is of the Subpart B—Coal Preparation Plants and Coal Preparation Plant Associated Areas","existing sources (BAT)","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr434","title":"40 CFR Part 434 — PART 434—COAL MINING POINT SOURCE CATEGORY BPT, BAT, BCT LIMITATIONS AND NEW SOURCE PERFORMANCE STANDARDS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=434","source_sha256":"59437ebfad1a7c3090dc8f3f11eac33d1cfa8c81e44baf92b3fcbfc75b584c19","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 434.23 (BAT)","page":null,"quote":"Manganese, total 4.0 2.0"}},{"id":"85560c86ed4d7992","parameter":"Manganese, total","value":"4.0","value_num":4,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 434","the discharge is of the Subpart B—Coal Preparation Plants and Coal Preparation Plant Associated Areas","new sources (NSPS)","table: NSPS Effluent Limitations (mg/l)"],"cite":{"instrument":"us_40cfr434","title":"40 CFR Part 434 — PART 434—COAL MINING POINT SOURCE CATEGORY BPT, BAT, BCT LIMITATIONS AND NEW SOURCE PERFORMANCE STANDARDS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=434","source_sha256":"59437ebfad1a7c3090dc8f3f11eac33d1cfa8c81e44baf92b3fcbfc75b584c19","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 434.25 (NSPS)","page":null,"quote":"Manganese, total 4.0 2.0"}},{"id":"d1769fd7d38caa2d","parameter":"Manganese, total","value":"2.0","value_num":2,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 434","the discharge is of the Subpart B—Coal Preparation Plants and Coal Preparation Plant Associated Areas","new sources (NSPS)","table: NSPS Effluent Limitations (mg/l)"],"cite":{"instrument":"us_40cfr434","title":"40 CFR Part 434 — PART 434—COAL MINING POINT SOURCE CATEGORY BPT, BAT, BCT LIMITATIONS AND NEW SOURCE PERFORMANCE STANDARDS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=434","source_sha256":"59437ebfad1a7c3090dc8f3f11eac33d1cfa8c81e44baf92b3fcbfc75b584c19","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 434.25 (NSPS)","page":null,"quote":"Manganese, total 4.0 2.0"}},{"id":"d22bdb27bd13e67a","parameter":"Manganese, total","value":"4.0","value_num":4,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 434","the discharge is of the Subpart C—Acid or Ferruginous Mine Drainage","existing sources (BPT)","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr434","title":"40 CFR Part 434 — PART 434—COAL MINING POINT SOURCE CATEGORY BPT, BAT, BCT LIMITATIONS AND NEW SOURCE PERFORMANCE STANDARDS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=434","source_sha256":"59437ebfad1a7c3090dc8f3f11eac33d1cfa8c81e44baf92b3fcbfc75b584c19","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 434.32 (BPT)","page":null,"quote":"Manganese, total 4.0 2.0"}},{"id":"2cd1a020f528ad63","parameter":"Manganese, total","value":"2.0","value_num":2,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 434","the discharge is of the Subpart C—Acid or Ferruginous Mine Drainage","existing sources (BPT)","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr434","title":"40 CFR Part 434 — PART 434—COAL MINING POINT SOURCE CATEGORY BPT, BAT, BCT LIMITATIONS AND NEW SOURCE PERFORMANCE STANDARDS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=434","source_sha256":"59437ebfad1a7c3090dc8f3f11eac33d1cfa8c81e44baf92b3fcbfc75b584c19","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 434.32 (BPT)","page":null,"quote":"Manganese, total 4.0 2.0"}},{"id":"6985fbc99fc043e8","parameter":"Manganese, total","value":"4.0","value_num":4,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 434","the discharge is of the Subpart C—Acid or Ferruginous Mine Drainage","existing sources (BPT)","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr434","title":"40 CFR Part 434 — PART 434—COAL MINING POINT SOURCE CATEGORY BPT, BAT, BCT LIMITATIONS AND NEW SOURCE PERFORMANCE STANDARDS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=434","source_sha256":"59437ebfad1a7c3090dc8f3f11eac33d1cfa8c81e44baf92b3fcbfc75b584c19","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 434.33 (BPT)","page":null,"quote":"Manganese, total 4.0 2.0"}},{"id":"15b59630e17593a6","parameter":"Manganese, total","value":"2.0","value_num":2,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 434","the discharge is of the Subpart C—Acid or Ferruginous Mine Drainage","existing sources (BPT)","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr434","title":"40 CFR Part 434 — PART 434—COAL MINING POINT SOURCE CATEGORY BPT, BAT, BCT LIMITATIONS AND NEW SOURCE PERFORMANCE STANDARDS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=434","source_sha256":"59437ebfad1a7c3090dc8f3f11eac33d1cfa8c81e44baf92b3fcbfc75b584c19","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 434.33 (BPT)","page":null,"quote":"Manganese, total 4.0 2.0"}},{"id":"9480a1a0a7994afe","parameter":"Manganese, total","value":"4.0","value_num":4,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 434","the discharge is of the Subpart C—Acid or Ferruginous Mine Drainage","new sources (NSPS)","table: NSPS Effluent Limitations"],"cite":{"instrument":"us_40cfr434","title":"40 CFR Part 434 — PART 434—COAL MINING POINT SOURCE CATEGORY BPT, BAT, BCT LIMITATIONS AND NEW SOURCE PERFORMANCE STANDARDS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=434","source_sha256":"59437ebfad1a7c3090dc8f3f11eac33d1cfa8c81e44baf92b3fcbfc75b584c19","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 434.35 (NSPS)","page":null,"quote":"Manganese, total 4.0 2.0"}},{"id":"c5592dd64825bac1","parameter":"Manganese, total","value":"2.0","value_num":2,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 434","the discharge is of the Subpart C—Acid or Ferruginous Mine Drainage","new sources (NSPS)","table: NSPS Effluent Limitations"],"cite":{"instrument":"us_40cfr434","title":"40 CFR Part 434 — PART 434—COAL MINING POINT SOURCE CATEGORY BPT, BAT, BCT LIMITATIONS AND NEW SOURCE PERFORMANCE STANDARDS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=434","source_sha256":"59437ebfad1a7c3090dc8f3f11eac33d1cfa8c81e44baf92b3fcbfc75b584c19","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 434.35 (NSPS)","page":null,"quote":"Manganese, total 4.0 2.0"}},{"id":"bd6b0883b0d49881","parameter":"Manganese, total","value":"4.0","value_num":4,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 434","the discharge is of the Subpart E—Post-Mining Areas","existing sources (BPT)","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr434","title":"40 CFR Part 434 — PART 434—COAL MINING POINT SOURCE CATEGORY BPT, BAT, BCT LIMITATIONS AND NEW SOURCE PERFORMANCE STANDARDS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=434","source_sha256":"59437ebfad1a7c3090dc8f3f11eac33d1cfa8c81e44baf92b3fcbfc75b584c19","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 434.52 (BPT)","page":null,"quote":"Manganese, total 4.0 2.0"}},{"id":"1f6a778652e375d4","parameter":"Manganese, total","value":"2.0","value_num":2,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 434","the discharge is of the Subpart E—Post-Mining Areas","existing sources (BPT)","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr434","title":"40 CFR Part 434 — PART 434—COAL MINING POINT SOURCE CATEGORY BPT, BAT, BCT LIMITATIONS AND NEW SOURCE PERFORMANCE STANDARDS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=434","source_sha256":"59437ebfad1a7c3090dc8f3f11eac33d1cfa8c81e44baf92b3fcbfc75b584c19","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 434.52 (BPT)","page":null,"quote":"Manganese, total 4.0 2.0"}},{"id":"ab53c62c2d82515c","parameter":"Manganese, total","value":"4.0","value_num":4,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 434","the discharge is of the Subpart E—Post-Mining Areas","existing sources (BAT)","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr434","title":"40 CFR Part 434 — PART 434—COAL MINING POINT SOURCE CATEGORY BPT, BAT, BCT LIMITATIONS AND NEW SOURCE PERFORMANCE STANDARDS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=434","source_sha256":"59437ebfad1a7c3090dc8f3f11eac33d1cfa8c81e44baf92b3fcbfc75b584c19","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 434.53 (BAT)","page":null,"quote":"Manganese, total 4.0 2.0"}},{"id":"8c953e0e0aa3350f","parameter":"Manganese, total","value":"2.0","value_num":2,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 434","the discharge is of the Subpart E—Post-Mining Areas","existing sources (BAT)","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr434","title":"40 CFR Part 434 — PART 434—COAL MINING POINT SOURCE CATEGORY BPT, BAT, BCT LIMITATIONS AND NEW SOURCE PERFORMANCE STANDARDS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=434","source_sha256":"59437ebfad1a7c3090dc8f3f11eac33d1cfa8c81e44baf92b3fcbfc75b584c19","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 434.53 (BAT)","page":null,"quote":"Manganese, total 4.0 2.0"}},{"id":"dd7029befb569c5f","parameter":"Manganese, total","value":"4.0","value_num":4,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 434","the discharge is of the Subpart E—Post-Mining Areas","new sources (NSPS)","table: NSPS Effluent Limitations"],"cite":{"instrument":"us_40cfr434","title":"40 CFR Part 434 — PART 434—COAL MINING POINT SOURCE CATEGORY BPT, BAT, BCT LIMITATIONS AND NEW SOURCE PERFORMANCE STANDARDS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=434","source_sha256":"59437ebfad1a7c3090dc8f3f11eac33d1cfa8c81e44baf92b3fcbfc75b584c19","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 434.55 (NSPS)","page":null,"quote":"Manganese, total 4.0 2.0"}},{"id":"0c6851d5690e5c6a","parameter":"Manganese, total","value":"2.0","value_num":2,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 434","the discharge is of the Subpart E—Post-Mining Areas","new sources (NSPS)","table: NSPS Effluent Limitations"],"cite":{"instrument":"us_40cfr434","title":"40 CFR Part 434 — PART 434—COAL MINING POINT SOURCE CATEGORY BPT, BAT, BCT LIMITATIONS AND NEW SOURCE PERFORMANCE STANDARDS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=434","source_sha256":"59437ebfad1a7c3090dc8f3f11eac33d1cfa8c81e44baf92b3fcbfc75b584c19","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 434.55 (NSPS)","page":null,"quote":"Manganese, total 4.0 2.0"}},{"id":"99de7a387891e61f","parameter":"Manganese","value":"0.019","value_num":0.019,"unit":"mg/kg of cells produced","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 461","the discharge is of the Subpart D—Leclanche Subcategory","new sources (NSPS)","(1) Subpart D—Foliar Battery Miscellaneous Wash—NSPS."],"cite":{"instrument":"us_40cfr461","title":"40 CFR Part 461 — PART 461—BATTERY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=461","source_sha256":"e9b2ea900bfea837890cb559b8db71416882d7666c81b683b11bdc700efb7b50","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 461.43 (NSPS)","page":null,"quote":"Manganese 0.019 0.015"}},{"id":"5975cc67d4e45323","parameter":"Manganese","value":"0.015","value_num":0.015,"unit":"mg/kg of cells produced","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 461","the discharge is of the Subpart D—Leclanche Subcategory","new sources (NSPS)","(1) Subpart D—Foliar Battery Miscellaneous Wash—NSPS."],"cite":{"instrument":"us_40cfr461","title":"40 CFR Part 461 — PART 461—BATTERY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=461","source_sha256":"e9b2ea900bfea837890cb559b8db71416882d7666c81b683b11bdc700efb7b50","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 461.43 (NSPS)","page":null,"quote":"Manganese 0.019 0.015"}},{"id":"b25e7209e8ce450e","parameter":"Manganese","value":"0.019","value_num":0.019,"unit":"mg/kg of cells produced","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is sewer","cites is 40 CFR 461","the discharge is of the Subpart D—Leclanche Subcategory","existing sources (PSES)","(1) Subpart D—Foliar Battery Miscellaneous Wash—PSES."],"cite":{"instrument":"us_40cfr461","title":"40 CFR Part 461 — PART 461—BATTERY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=461","source_sha256":"e9b2ea900bfea837890cb559b8db71416882d7666c81b683b11bdc700efb7b50","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 461.44 (PSES)","page":null,"quote":"Manganese 0.019 0.015"}},{"id":"e1dd2d3115f01626","parameter":"Manganese","value":"0.015","value_num":0.015,"unit":"mg/kg of cells produced","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is sewer","cites is 40 CFR 461","the discharge is of the Subpart D—Leclanche Subcategory","existing sources (PSES)","(1) Subpart D—Foliar Battery Miscellaneous Wash—PSES."],"cite":{"instrument":"us_40cfr461","title":"40 CFR Part 461 — PART 461—BATTERY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=461","source_sha256":"e9b2ea900bfea837890cb559b8db71416882d7666c81b683b11bdc700efb7b50","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 461.44 (PSES)","page":null,"quote":"Manganese 0.019 0.015"}},{"id":"895d1b520908b554","parameter":"Manganese","value":"0.019","value_num":0.019,"unit":"mg/kg of cells produced","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is sewer","cites is 40 CFR 461","the discharge is of the Subpart D—Leclanche Subcategory","new sources (PSNS)","(1) Subpart D—Foliar Battery Miscellaneous Wash—PSNS."],"cite":{"instrument":"us_40cfr461","title":"40 CFR Part 461 — PART 461—BATTERY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=461","source_sha256":"e9b2ea900bfea837890cb559b8db71416882d7666c81b683b11bdc700efb7b50","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 461.45 (PSNS)","page":null,"quote":"Manganese 0.019 0.015"}},{"id":"f0cee801bafdbf2a","parameter":"Manganese","value":"0.015","value_num":0.015,"unit":"mg/kg of cells produced","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is sewer","cites is 40 CFR 461","the discharge is of the Subpart D—Leclanche Subcategory","new sources (PSNS)","(1) Subpart D—Foliar Battery Miscellaneous Wash—PSNS."],"cite":{"instrument":"us_40cfr461","title":"40 CFR Part 461 — PART 461—BATTERY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=461","source_sha256":"e9b2ea900bfea837890cb559b8db71416882d7666c81b683b11bdc700efb7b50","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 461.45 (PSNS)","page":null,"quote":"Manganese 0.019 0.015"}},{"id":"dbe629f833d82370","parameter":"Manganese","value":"2.58","value_num":2.58,"unit":"mg/kg of Zinc","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 461","the discharge is of the Subpart G—Zinc Subcategory","existing sources (BPT)","(1) Subpart G—Wet Amalgamated Powder Anodes.","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr461","title":"40 CFR Part 461 — PART 461—BATTERY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=461","source_sha256":"e9b2ea900bfea837890cb559b8db71416882d7666c81b683b11bdc700efb7b50","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 461.71 (BPT)","page":null,"quote":"Manganese 2.58 1.10"}},{"id":"0a166ab01b105446","parameter":"Manganese","value":"1.10","value_num":1.1,"unit":"mg/kg of Zinc","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 461","the discharge is of the Subpart G—Zinc Subcategory","existing sources (BPT)","(1) Subpart G—Wet Amalgamated Powder Anodes.","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr461","title":"40 CFR Part 461 — PART 461—BATTERY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=461","source_sha256":"e9b2ea900bfea837890cb559b8db71416882d7666c81b683b11bdc700efb7b50","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 461.71 (BPT)","page":null,"quote":"Manganese 2.58 1.10"}},{"id":"270d799f4fe0a249","parameter":"Manganese","value":"0.46","value_num":0.46,"unit":"mg/kg of Zinc","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 461","the discharge is of the Subpart G—Zinc Subcategory","existing sources (BPT)","(2) Subpart G—Gelled Amalgam Anodes.","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr461","title":"40 CFR Part 461 — PART 461—BATTERY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=461","source_sha256":"e9b2ea900bfea837890cb559b8db71416882d7666c81b683b11bdc700efb7b50","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 461.71 (BPT)","page":null,"quote":"Manganese 0.46 0.20"}},{"id":"09cacac9c202ef2b","parameter":"Manganese","value":"0.20","value_num":0.2,"unit":"mg/kg of Zinc","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 461","the discharge is of the Subpart G—Zinc Subcategory","existing sources (BPT)","(2) Subpart G—Gelled Amalgam Anodes.","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr461","title":"40 CFR Part 461 — PART 461—BATTERY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=461","source_sha256":"e9b2ea900bfea837890cb559b8db71416882d7666c81b683b11bdc700efb7b50","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 461.71 (BPT)","page":null,"quote":"Manganese 0.46 0.20"}},{"id":"2ec672edf2c2854c","parameter":"Manganese","value":"97.2","value_num":97.2,"unit":"mg/kg of Zinc","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 461","the discharge is of the Subpart G—Zinc Subcategory","existing sources (BPT)","(3) Subpart G—Zinc Oxide, Formed Anodes.","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr461","title":"40 CFR Part 461 — PART 461—BATTERY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=461","source_sha256":"e9b2ea900bfea837890cb559b8db71416882d7666c81b683b11bdc700efb7b50","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 461.71 (BPT)","page":null,"quote":"Manganese 97.2 41.5"}},{"id":"7efd3b404a1bdba0","parameter":"Manganese","value":"41.5","value_num":41.5,"unit":"mg/kg of Zinc","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 461","the discharge is of the Subpart G—Zinc Subcategory","existing sources (BPT)","(3) Subpart G—Zinc Oxide, Formed Anodes.","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr461","title":"40 CFR Part 461 — PART 461—BATTERY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=461","source_sha256":"e9b2ea900bfea837890cb559b8db71416882d7666c81b683b11bdc700efb7b50","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 461.71 (BPT)","page":null,"quote":"Manganese 97.2 41.5"}},{"id":"785ec2214fd47c1b","parameter":"Manganese","value":"2,169.0","value_num":2169,"unit":"mg/kg of zinc deposited","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 461","the discharge is of the Subpart G—Zinc Subcategory","existing sources (BPT)","(4) Subpart G—Electrodeposited Anodes.","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr461","title":"40 CFR Part 461 — PART 461—BATTERY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=461","source_sha256":"e9b2ea900bfea837890cb559b8db71416882d7666c81b683b11bdc700efb7b50","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 461.71 (BPT)","page":null,"quote":"Manganese 2,169.0 925.0"}},{"id":"bb2280f325ea4da5","parameter":"Manganese","value":"925.0","value_num":925,"unit":"mg/kg of zinc deposited","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 461","the discharge is of the Subpart G—Zinc Subcategory","existing sources (BPT)","(4) Subpart G—Electrodeposited Anodes.","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr461","title":"40 CFR Part 461 — PART 461—BATTERY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=461","source_sha256":"e9b2ea900bfea837890cb559b8db71416882d7666c81b683b11bdc700efb7b50","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 461.71 (BPT)","page":null,"quote":"Manganese 2,169.0 925.0"}},{"id":"6127eaff156a6308","parameter":"Manganese","value":"133.3","value_num":133.3,"unit":"mg/kg of silver applied","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7439-96-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 461","the discharge is of the Subpart G—Zinc Subcategory","existing sources (BPT)","(5) Subpart G—Silver Powder, Formed Cathodes.","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr461","title":"40 CFR Part 461 — PART 461—BATTERY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=461","source_sha256":"e9b2ea900bfea837890cb559b8db71416882d7666c81b683b11bdc700efb7b50","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 461.71 (BPT)","page":null,"quote":"Manganese 133.3 56.8"}}],"next":[{"tool":"check_values","says":"Has your user measured this? check_values sets each of their results beside every row held here, with a verdict and the row's cite.","arguments":{"place":"US-FL"},"needs":{"rows":"Your user's measured results, as their table prints them: [{parameter: \"manganese\", value, unit}, ...], any other parameters too."},"post":"/api/v1/check"},{"tool":"read_certificate","says":"Has your user a laboratory certificate? read_certificate reads every row it prints, each with its page, and checks them against these limits.","arguments":{"place":"US-FL"},"needs":{"content_base64":"The laboratory's certificate (PDF) or its XLSX, XLS or CSV export, as base64; or file_url, a public https address of it."},"post":"/api/v1/certificate"}]}