{"query":{"parameter":"giftigkeit gegenuber leuchtbakterien gl","place":"DE","medium":null,"statistic":null,"kind":null},"searched":{"places":["DE","EU"],"parameter_keys":["name:luminescent bacteria toxicity"],"names_matched":[["giftigkeit gegenuber leuchtbakterien gl","name:luminescent bacteria toxicity"]],"match":"exact","order":"The place's own instruments first, then each place above it, each in its register's order"},"total":7,"offset":0,"returned":7,"next_offset":null,"rows":[{"id":"f7effd9ab8c9ae96","parameter":"Giftigkeit gegenüber Leuchtbakterien (GL)","value":"32","value_num":32,"unit":"dilution factor","statistic":"qualified_grab","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:luminescent bacteria toxicity","place":["DE"],"conditions":["cites is AbwV Anhang 22","route is direct"],"cite":{"instrument":"de_abwv_a22","title":"Abwasserverordnung (AbwV), Anhang 22 — Chemische Industrie","issuer":null,"edition":"Fundstelle: BGBl. 2024 I Nr. 66, S. 3 – 11","source_url":"https://www.gesetze-im-internet.de/abwv/anhang_22.html","source_sha256":"7a954426c0eb6e445175543b206c7149c87ddca756780de74638c62b6c023b55","fetched_at":"2026-10-10","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"Teil C Absatz 3 Nr. 3","page":null,"quote":"Giftigkeit gegenüber Leuchtbakterien G L = 32"}},{"id":"ef5ff0dd3575fcbc","parameter":"Giftigkeit gegenüber Leuchtbakterien","value":"4","value_num":4,"unit":"dilution factor","direction":"max","kind":"acceptance","medium":"water_discharge","level":"national","parameter_key":"name:luminescent bacteria toxicity","place":["DE"],"conditions":["cites is AbwV Anhang 23","vor der Vermischung mit anderem Abwasser (Teil D) — bindet die Einleitung in das Gewässer und ebenso die Indirekteinleitung in eine öffentliche Abwasseranlage (WHG § 58 Abs. 1)","Voraussetzung, um das Abwasser mit anderem Abwasser zur gemeinsamen biologischen Behandlung zu vermischen (Teil D Absatz 2): mindestens eine der Voraussetzungen Nr. 1-3 muss zu erwarten sein","nach Durchführung eines Eliminationstestes mit Hilfe einer biologischen Labor-Durchlaufkläranlage (z. B. DIN 38412-L 26)"],"cite":{"instrument":"de_abwv_a23","title":"Abwasserverordnung (AbwV), Anhang 23 — Anlagen zur biologischen Behandlung von Abfällen","issuer":null,"edition":"Fundstelle: BGBl. I 2004, 1137 - 1138; bzgl. der einzelnen Änderungen vgl. Fußnote","source_url":"https://www.gesetze-im-internet.de/abwv/anhang_23.html","source_sha256":"7274f38e6934ea83b788bcd7db92a8010038af728f355624f27a1cb568a91468","fetched_at":"2026-10-10","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"Teil D Absatz 2 Nr. 1","page":null,"quote":"Giftigkeit gegenüber Leuchtbakterien G L = 4."}},{"id":"d7ccef551b42e34a","parameter":"Giftigkeit gegenüber Leuchtbakterien (GL)","value":"4","value_num":4,"unit":"dilution factor","statistic":"qualified_grab","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"name:luminescent bacteria toxicity","place":["DE"],"conditions":["cites is AbwV Anhang 27","route is direct"],"cite":{"instrument":"de_abwv_a27","title":"Abwasserverordnung (AbwV), Anhang 27 — Behandlung von Abfällen durch chemische und physikalische Verfahren (CP-Anlagen) sowie Altölaufarbeitung","issuer":null,"edition":"Fundstelle: BGBl. I 2004, 1142 - 1144; bzgl. der einzelnen Änderungen vgl. Fußnote","source_url":"https://www.gesetze-im-internet.de/abwv/anhang_27.html","source_sha256":"c7ceb1e54e45521c2cd5409685784da4b436d3133db93f0e53aaaefa9a21afec","fetched_at":"2026-10-10","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"Teil C Absatz 1","page":null,"quote":"Giftigkeit gegenüber Leuchtbakterien (G L ) 4"}},{"id":"8ddafcd14fecc884","parameter":"Giftigkeit gegenüber Leuchtbakterien","value":"4","value_num":4,"unit":"dilution factor","direction":"max","kind":"acceptance","medium":"water_discharge","level":"national","parameter_key":"name:luminescent bacteria toxicity","place":["DE"],"conditions":["cites is AbwV Anhang 27","vor der Vermischung mit anderem Abwasser (Teil D) — bindet die Einleitung in das Gewässer und ebenso die Indirekteinleitung in eine öffentliche Abwasseranlage (WHG § 58 Abs. 1)","Voraussetzung, um das Abwasser mit anderem Abwasser zur gemeinsamen biologischen Behandlung zu vermischen (Teil D Absatz 2): mindestens eine der Voraussetzungen Nr. 1-2 muss zu erwarten sein","nach Durchführung eines Eliminationstestes mit Hilfe einer biologischen Labor-Durchlaufkläranlage (z. B. DIN 38412-L 26)"],"cite":{"instrument":"de_abwv_a27","title":"Abwasserverordnung (AbwV), Anhang 27 — Behandlung von Abfällen durch chemische und physikalische Verfahren (CP-Anlagen) sowie Altölaufarbeitung","issuer":null,"edition":"Fundstelle: BGBl. I 2004, 1142 - 1144; bzgl. der einzelnen Änderungen vgl. Fußnote","source_url":"https://www.gesetze-im-internet.de/abwv/anhang_27.html","source_sha256":"c7ceb1e54e45521c2cd5409685784da4b436d3133db93f0e53aaaefa9a21afec","fetched_at":"2026-10-10","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"Teil D Absatz 2 Nr. 1","page":null,"quote":"Giftigkeit gegenüber Leuchtbakterien G L = 4."}},{"id":"843742e82b347a97","parameter":"Giftigkeit gegenüber Leuchtbakterien (GL)","value":"12","value_num":12,"unit":"dilution factor","statistic":"instant","direction":"max","kind":"limit","medium":"water_discharge","level":"national","stream":"cooling","parameter_key":"name:luminescent bacteria toxicity","place":["DE"],"conditions":["cites is AbwV Anhang 31","am Ort des Anfalls (Teil E) — bindet die Einleitung in das Gewässer und ebenso die Indirekteinleitung in eine öffentliche Abwasseranlage (WHG § 58 Abs. 1)","stream is cooling","(1) An das Abwasser aus einem der folgenden Bereiche werden folgende Anforderungen nach Durchführung einer Stoßbehandlung mit mikrobiziden Wirkstoffen gestellt:","Abflutung von Hauptkühlkreisläufen von Kraftwerken (Abflutwasser aus der Umlaufkühlung)"],"cite":{"instrument":"de_abwv_a31","title":"Abwasserverordnung (AbwV), Anhang 31 — Wasseraufbereitung, Kühlsysteme, Dampferzeugung","issuer":null,"edition":"Fundstelle: BGBl. I 2004, 1147 - 1150; bzgl. der einzelnen Änderungen vgl. Fußnote","source_url":"https://www.gesetze-im-internet.de/abwv/anhang_31.html","source_sha256":"dee34048e97bb46ead72a4d01387a01c878d7ed18e5cfcba6a8574bcdaef0367","fetched_at":"2026-10-10","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"Teil E Absatz 1","page":null,"quote":"Giftigkeit gegenüber Leuchtbakterien (G(tief)L) - 12 12"}},{"id":"014fece500fb2da4","parameter":"Giftigkeit gegenüber Leuchtbakterien (GL)","value":"12","value_num":12,"unit":"dilution factor","statistic":"instant","direction":"max","kind":"limit","medium":"water_discharge","level":"national","stream":"cooling","parameter_key":"name:luminescent bacteria toxicity","place":["DE"],"conditions":["cites is AbwV Anhang 31","am Ort des Anfalls (Teil E) — bindet die Einleitung in das Gewässer und ebenso die Indirekteinleitung in eine öffentliche Abwasseranlage (WHG § 58 Abs. 1)","stream is cooling","(1) An das Abwasser aus einem der folgenden Bereiche werden folgende Anforderungen nach Durchführung einer Stoßbehandlung mit mikrobiziden Wirkstoffen gestellt:","Abflutung sonstiger Kühlkreisläufe"],"cite":{"instrument":"de_abwv_a31","title":"Abwasserverordnung (AbwV), Anhang 31 — Wasseraufbereitung, Kühlsysteme, Dampferzeugung","issuer":null,"edition":"Fundstelle: BGBl. I 2004, 1147 - 1150; bzgl. der einzelnen Änderungen vgl. Fußnote","source_url":"https://www.gesetze-im-internet.de/abwv/anhang_31.html","source_sha256":"dee34048e97bb46ead72a4d01387a01c878d7ed18e5cfcba6a8574bcdaef0367","fetched_at":"2026-10-10","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"Teil E Absatz 1","page":null,"quote":"Giftigkeit gegenüber Leuchtbakterien (G(tief)L) - 12 12"}},{"id":"6ae8d47647bdc950","parameter":"Giftigkeit gegenüber Leuchtbakterien","value":"4","value_num":4,"unit":"dilution factor","direction":"max","kind":"acceptance","medium":"water_discharge","level":"national","parameter_key":"name:luminescent bacteria toxicity","place":["DE"],"conditions":["cites is AbwV Anhang 51","vor der Vermischung mit anderem Abwasser (Teil D) — bindet die Einleitung in das Gewässer und ebenso die Indirekteinleitung in eine öffentliche Abwasseranlage (WHG § 58 Abs. 1)","Voraussetzung, um das Abwasser mit anderem Abwasser zur gemeinsamen biologischen Behandlung zu vermischen (Teil D Absatz 2): mindestens eine der Voraussetzungen Nr. 1-3 muss zu erwarten sein","nach Durchführung eines Eliminationstestes mit Hilfe einer biologischen Labor-Durchlaufkläranlage (z. B. DIN 38412-L 26)"],"cite":{"instrument":"de_abwv_a51","title":"Abwasserverordnung (AbwV), Anhang 51 — Oberirdische Ablagerung von Abfällen","issuer":null,"edition":"Fundstelle: BGBl. I 2004, 1175 - 1177; bzgl. der einzelnen Änderungen vgl. Fußnote","source_url":"https://www.gesetze-im-internet.de/abwv/anhang_51.html","source_sha256":"c34ad0067beb8a801d2caca2e7251defdfe35256cfc8ddc978988e9fdc9b432c","fetched_at":"2026-10-10","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"Teil D Absatz 2 Nr. 1","page":null,"quote":"Giftigkeit gegenüber Leuchtbakterien G L = 4."}}],"next":[{"tool":"check_values","says":"Has your user measured this? check_values sets each of their results beside every row held here, with a verdict and the row's cite.","arguments":{"place":"DE"},"needs":{"rows":"Your user's measured results, as their table prints them: [{parameter: \"giftigkeit gegenuber leuchtbakterien gl\", value, unit}, ...], any other parameters too."},"post":"/api/v1/check"},{"tool":"read_certificate","says":"Has your user a laboratory certificate? read_certificate reads every row it prints, each with its page, and checks them against these limits.","arguments":{"place":"DE"},"needs":{"content_base64":"The laboratory's certificate (PDF) or its XLSX, XLS or CSV export, as base64; or file_url, a public https address of it."},"post":"/api/v1/certificate"}]}