{"query":{"parameter":"fluoride","place":"US-FL","medium":null,"statistic":null,"kind":null},"searched":{"places":["US-FL","US"],"parameter_keys":["cas:16984-48-8","cas:7681-49-4","cas:7782-41-4","name:fluoride @ 90°f","cas:7664-39-3","name:fluorures totaux"],"names_matched":[["fluoride","cas:16984-48-8"],["fluoride","cas:7681-49-4"],["fluoride","cas:7782-41-4"],["fluoride 90 f","name:fluoride @ 90°f"],["hydrogen fluoride","cas:7664-39-3"],["fluor und seine gasformigen anorganischen verbindungen angegeben als fluorwasserstoff","cas:7664-39-3","fluor"],["fluor und seine gasformigen verbindungen angegeben als fluorwasserstoff","cas:7664-39-3","fluor"],["fluorwasserstoff und gasformige anorganische fluorverbindungen angegeben als fluor","cas:7664-39-3","fluor"],["fluorides as hf","cas:7664-39-3","fluorides"],["fluorides as hf gaseous growing season","cas:7664-39-3","fluorides"],["fluorides as hf total growing season","cas:7664-39-3","fluorides"],["fluorides as hf total non growing season","cas:7664-39-3","fluorides"],["gaseous fluorides expressed as hf","cas:7664-39-3","fluorides"],["fluorures totaux","name:fluorures totaux","fluorures"],["fluorures totaux f","name:fluorures totaux","fluorures"]],"match":"exact+contains","order":"The place's own instruments first, then each place above it, each in its register's order"},"total":1576,"offset":0,"returned":50,"next_offset":50,"rows":[{"id":"27dc411bf554edd0","parameter":"Fluoride","value":"< 1.5","value_num":1.5,"unit":"mg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:16984-48-8","place":["US-FL"],"conditions":["receiving_water is freshwater","Class I, potable water supplies (waters listed by name in 62-302.400, F.A.C.)"],"cite":{"instrument":"us_fl_wqs","title":"F.A.C. 62-302.530 Table: Surface Water Quality Criteria (Florida) — Class I, II, III fresh, III marine and IV criteria","issuer":"State of Florida, Department of Environmental Protection (Environmental Regulation Commission)","edition":"Chapter 62-302, F.A.C., as US EPA posts it in effect for Clean Water Act purposes; 62-302.530 amended through 11-25-25 (its history note, p. 45); EPA's re-posting of 2026-10-05 (PDF CreationDate), fetched 2026-10-15","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/fl_section62-302.pdf","source_sha256":"9865f1a6486a9332278c619fbcd71dc9f4f19af10e39576eea8ae900136aa284","fetched_at":"2026-10-15","section":"F.A.C. 62-302.530(32)","page":35,"quote":null}},{"id":"48bdfe9f4dfd20e4","parameter":"Fluoride","value":"< 1.5","value_num":1.5,"unit":"mg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:16984-48-8","place":["US-FL"],"conditions":["receiving_water is marine","Class II, shellfish propagation or harvesting (waters listed by name in 62-302.400, F.A.C.)"],"cite":{"instrument":"us_fl_wqs","title":"F.A.C. 62-302.530 Table: Surface Water Quality Criteria (Florida) — Class I, II, III fresh, III marine and IV criteria","issuer":"State of Florida, Department of Environmental Protection (Environmental Regulation Commission)","edition":"Chapter 62-302, F.A.C., as US EPA posts it in effect for Clean Water Act purposes; 62-302.530 amended through 11-25-25 (its history note, p. 45); EPA's re-posting of 2026-10-05 (PDF CreationDate), fetched 2026-10-15","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/fl_section62-302.pdf","source_sha256":"9865f1a6486a9332278c619fbcd71dc9f4f19af10e39576eea8ae900136aa284","fetched_at":"2026-10-15","section":"F.A.C. 62-302.530(32)","page":35,"quote":null}},{"id":"00d9f4d6f633764b","parameter":"Fluoride","value":"< 10.0","value_num":10,"unit":"mg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:16984-48-8","place":["US-FL"],"conditions":["receiving_water is freshwater","Class III and Class III-Limited, predominantly fresh waters (every Florida surface water not listed in 62-302.400, F.A.C., is Class III)"],"cite":{"instrument":"us_fl_wqs","title":"F.A.C. 62-302.530 Table: Surface Water Quality Criteria (Florida) — Class I, II, III fresh, III marine and IV criteria","issuer":"State of Florida, Department of Environmental Protection (Environmental Regulation Commission)","edition":"Chapter 62-302, F.A.C., as US EPA posts it in effect for Clean Water Act purposes; 62-302.530 amended through 11-25-25 (its history note, p. 45); EPA's re-posting of 2026-10-05 (PDF CreationDate), fetched 2026-10-15","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/fl_section62-302.pdf","source_sha256":"9865f1a6486a9332278c619fbcd71dc9f4f19af10e39576eea8ae900136aa284","fetched_at":"2026-10-15","section":"F.A.C. 62-302.530(32)","page":35,"quote":null}},{"id":"7d08c75ac02e6b24","parameter":"Fluoride","value":"< 5.0","value_num":5,"unit":"mg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:16984-48-8","place":["US-FL"],"conditions":["receiving_water is marine","Class III and Class III-Limited, predominantly marine waters (every Florida surface water not listed in 62-302.400, F.A.C., is Class III)"],"cite":{"instrument":"us_fl_wqs","title":"F.A.C. 62-302.530 Table: Surface Water Quality Criteria (Florida) — Class I, II, III fresh, III marine and IV criteria","issuer":"State of Florida, Department of Environmental Protection (Environmental Regulation Commission)","edition":"Chapter 62-302, F.A.C., as US EPA posts it in effect for Clean Water Act purposes; 62-302.530 amended through 11-25-25 (its history note, p. 45); EPA's re-posting of 2026-10-05 (PDF CreationDate), fetched 2026-10-15","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/fl_section62-302.pdf","source_sha256":"9865f1a6486a9332278c619fbcd71dc9f4f19af10e39576eea8ae900136aa284","fetched_at":"2026-10-15","section":"F.A.C. 62-302.530(32)","page":35,"quote":null}},{"id":"b2c257dd60821186","parameter":"Fluoride","value":"< 10.0","value_num":10,"unit":"mg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:16984-48-8","place":["US-FL"],"conditions":["receiving_water is freshwater","Class IV, agricultural water supplies (waters listed by name in 62-302.400, F.A.C.)"],"cite":{"instrument":"us_fl_wqs","title":"F.A.C. 62-302.530 Table: Surface Water Quality Criteria (Florida) — Class I, II, III fresh, III marine and IV criteria","issuer":"State of Florida, Department of Environmental Protection (Environmental Regulation Commission)","edition":"Chapter 62-302, F.A.C., as US EPA posts it in effect for Clean Water Act purposes; 62-302.530 amended through 11-25-25 (its history note, p. 45); EPA's re-posting of 2026-10-05 (PDF CreationDate), fetched 2026-10-15","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/fl_section62-302.pdf","source_sha256":"9865f1a6486a9332278c619fbcd71dc9f4f19af10e39576eea8ae900136aa284","fetched_at":"2026-10-15","section":"F.A.C. 62-302.530(32)","page":35,"quote":null}},{"id":"d77e7e1082d44391","parameter":"Fluoride","value":"2000","value_num":2000,"unit":"µg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:7782-41-4","place":["US-FL"],"conditions":["groundwater (Table I, Groundwater Criteria column)","Note: If more than one contaminant is present at a site, CTLs are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Figure 10 of the February 2005 'Final Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.' However, GCTLs for primary and secondary standards shall not be modified."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","section":"Ch. 62-777 F.A.C. Table I, Groundwater and Surface Water Cleanup Target Levels, Groundwater Criteria (DEP spreadsheet, sheet TTable1, row 278)","page":null,"quote":"row 278: Fluoride | 2000 | 10000 | 5000 | 20000 | -Teeth mottling | 7782-41-4 |  | Secondary Standard | 62-302 | 62-302 |  | Nuisance"}},{"id":"1d12e0978f1fab0a","parameter":"Fluoride","value":"10000","value_num":10000,"unit":"µg/L","direction":"max","kind":"threshold","medium":"surface_water","level":"regional","parameter_key":"cas:7782-41-4","place":["US-FL"],"conditions":["receiving_water is freshwater","freshwater surface water (Table I, Freshwater Surface Water Criteria column)","Note: If more than one contaminant is present at a site, CTLs are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Figure 10 of the February 2005 'Final Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.' However, GCTLs for primary and secondary standards shall not be modified."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","section":"Ch. 62-777 F.A.C. Table I, Groundwater and Surface Water Cleanup Target Levels, Freshwater Surface Water Criteria (DEP spreadsheet, sheet TTable1, row 278)","page":null,"quote":"row 278: Fluoride | 2000 | 10000 | 5000 | 20000 | -Teeth mottling | 7782-41-4 |  | Secondary Standard | 62-302 | 62-302 |  | Nuisance"}},{"id":"fd63395c77c146b0","parameter":"Fluoride","value":"5000","value_num":5000,"unit":"µg/L","direction":"max","kind":"threshold","medium":"surface_water","level":"regional","parameter_key":"cas:7782-41-4","place":["US-FL"],"conditions":["receiving_water is marine","marine surface water (Table I, Marine Surface Water Criteria column)","Note: If more than one contaminant is present at a site, CTLs are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Figure 10 of the February 2005 'Final Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.' However, GCTLs for primary and secondary standards shall not be modified."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","section":"Ch. 62-777 F.A.C. Table I, Groundwater and Surface Water Cleanup Target Levels, Marine Surface Water Criteria (DEP spreadsheet, sheet TTable1, row 278)","page":null,"quote":"row 278: Fluoride | 2000 | 10000 | 5000 | 20000 | -Teeth mottling | 7782-41-4 |  | Secondary Standard | 62-302 | 62-302 |  | Nuisance"}},{"id":"bf2d07671504cc45","parameter":"Fluoride","value":"20000","value_num":20000,"unit":"µg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:7782-41-4","place":["US-FL"],"conditions":["groundwater of low yield/poor quality (Table I, Groundwater of Low Yield/Poor Quality Criteria column)","Note: If more than one contaminant is present at a site, CTLs are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Figure 10 of the February 2005 'Final Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.' However, GCTLs for primary and secondary standards shall not be modified."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","section":"Ch. 62-777 F.A.C. Table I, Groundwater and Surface Water Cleanup Target Levels, Groundwater of Low Yield/Poor Quality Criteria (DEP spreadsheet, sheet TTable1, row 278)","page":null,"quote":"row 278: Fluoride | 2000 | 10000 | 5000 | 20000 | -Teeth mottling | 7782-41-4 |  | Secondary Standard | 62-302 | 62-302 |  | Nuisance"}},{"id":"9ae2ab919225049b","parameter":"Fluoride","value":"840","value_num":840,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7782-41-4","place":["US-FL"],"conditions":["residential direct exposure (Table II, Direct Exposure - Residential column)","** Direct exposure value based on acute toxicity considerations. This criterion is applicable in scenarios where children might be exposed to soils (e.g. residences, schools, playgrounds)","Note: If more than one contaminant is present at a site, the direct exposure values are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Appendix D 'Draft Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.', dated February 2005."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","section":"Ch. 62-777 F.A.C. Table II, Soil Cleanup Target Levels, Direct Exposure - Residential (DEP spreadsheet, sheet TTable2, row 257)","page":null,"quote":"row 257: Fluoride | -Teeth mottling | 7782-41-4 | 840** | 130000 | 6000 | 30000 | 15000 | 60000"}},{"id":"3226c9ba1fdfc06d","parameter":"Fluoride","value":"130000","value_num":130000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7782-41-4","place":["US-FL"],"conditions":["industrial direct exposure (Table II, Direct Exposure - Industrial column)","Note: If more than one contaminant is present at a site, the direct exposure values are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Appendix D 'Draft Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.', dated February 2005."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","section":"Ch. 62-777 F.A.C. Table II, Soil Cleanup Target Levels, Direct Exposure - Industrial (DEP spreadsheet, sheet TTable2, row 257)","page":null,"quote":"row 257: Fluoride | -Teeth mottling | 7782-41-4 | 840** | 130000 | 6000 | 30000 | 15000 | 60000"}},{"id":"ed764bcd0e491e87","parameter":"Fluoride","value":"6000","value_num":6000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7782-41-4","place":["US-FL"],"conditions":["leachability based on groundwater criteria (Table II, Leachability Based on Groundwater column)","Note: If more than one contaminant is present at a site, the direct exposure values are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Appendix D 'Draft Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.', dated February 2005."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","section":"Ch. 62-777 F.A.C. Table II, Soil Cleanup Target Levels, Leachability Based on Groundwater (DEP spreadsheet, sheet TTable2, row 257)","page":null,"quote":"row 257: Fluoride | -Teeth mottling | 7782-41-4 | 840** | 130000 | 6000 | 30000 | 15000 | 60000"}},{"id":"6bc9d1cac4b2f647","parameter":"Fluoride","value":"30000","value_num":30000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7782-41-4","place":["US-FL"],"conditions":["leachability based on freshwater surface water criteria (Table II, Leachability Based on Freshwater SW column)","Note: If more than one contaminant is present at a site, the direct exposure values are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Appendix D 'Draft Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.', dated February 2005."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","section":"Ch. 62-777 F.A.C. Table II, Soil Cleanup Target Levels, Leachability Based on Freshwater SW (DEP spreadsheet, sheet TTable2, row 257)","page":null,"quote":"row 257: Fluoride | -Teeth mottling | 7782-41-4 | 840** | 130000 | 6000 | 30000 | 15000 | 60000"}},{"id":"2fea7e9533932b2d","parameter":"Fluoride","value":"15000","value_num":15000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7782-41-4","place":["US-FL"],"conditions":["leachability based on marine surface water criteria (Table II, Leachability Based on Marine SW column)","Note: If more than one contaminant is present at a site, the direct exposure values are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Appendix D 'Draft Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.', dated February 2005."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","section":"Ch. 62-777 F.A.C. Table II, Soil Cleanup Target Levels, Leachability Based on Marine SW (DEP spreadsheet, sheet TTable2, row 257)","page":null,"quote":"row 257: Fluoride | -Teeth mottling | 7782-41-4 | 840** | 130000 | 6000 | 30000 | 15000 | 60000"}},{"id":"7211af3c3ace8fb0","parameter":"Fluoride","value":"60000","value_num":60000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7782-41-4","place":["US-FL"],"conditions":["leachability based on groundwater of low yield/poor quality criteria (Table II, Leachability based on GW of Low Yield/Poor Quality column)","Note: If more than one contaminant is present at a site, the direct exposure values are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Appendix D 'Draft Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.', dated February 2005."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","section":"Ch. 62-777 F.A.C. Table II, Soil Cleanup Target Levels, Leachability based on GW of Low Yield/Poor Quality (DEP spreadsheet, sheet TTable2, row 257)","page":null,"quote":"row 257: Fluoride | -Teeth mottling | 7782-41-4 | 840** | 130000 | 6000 | 30000 | 15000 | 60000"}},{"id":"90b355b89825f281","parameter":"Fluoride","value":"35","value_num":35,"unit":"mg/L","statistic":"composite","direction":"max","kind":"limit","medium":"product","level":"national","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["(a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS."],"cite":{"instrument":"us_40cfr268_48","title":"40 CFR 268.48 — Universal treatment standards: Table UTS, wastewater and nonwastewater treatment standards for the hazardous constituents of land-disposal-restricted wastes","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"eCFR, 40 CFR 268.48 as of 2026-10-13 (title 40 up to date as of that day; source note: 59 FR 48103, Sept. 19, 1994, as last amended at 76 FR 34156, June 13, 2011)","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-13/title-40.xml?part=268&section=268.48","source_sha256":"70b2e58a6b1e228e2c204acc69b69fab0d5a0347e35d569959073c3dc3ee4adb","fetched_at":"2026-10-15","section":"40 CFR 268.48, Table UTS, Inorganic Constituents, wastewater standard","page":null,"quote":"Fluoride 5 16984-48-8 35 NA"}},{"id":"5755018f973ffbee","parameter":"Fluoride (T)","value":"6.1","value_num":6.1,"unit":"Kg/kkg (or pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart H—Hydrofluoric Acid Production Subcategory","existing sources (BPT)","table: Subpart H—Hydrofluoric Acid"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.82 (BPT)","page":null,"quote":"Fluoride (T) 6.1 2.9"}},{"id":"c7d32fa29b642d12","parameter":"Fluoride (T)","value":"2.9","value_num":2.9,"unit":"Kg/kkg (or pounds per 1,000 lb) of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart H—Hydrofluoric Acid Production Subcategory","existing sources (BPT)","table: Subpart H—Hydrofluoric Acid"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.82 (BPT)","page":null,"quote":"Fluoride (T) 6.1 2.9"}},{"id":"8aa8fae40c3861ae","parameter":"Fluoride (T)","value":"3.4","value_num":3.4,"unit":"Kg/kkg (or pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart H—Hydrofluoric Acid Production Subcategory","existing sources (BAT)","table: Subpart H—Hydrofluoric Acid"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.83 (BAT)","page":null,"quote":"Fluoride (T) 3.4 1.6"}},{"id":"8d8037e5a3fc8de5","parameter":"Fluoride (T)","value":"1.6","value_num":1.6,"unit":"Kg/kkg (or pounds per 1,000 lb) of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart H—Hydrofluoric Acid Production Subcategory","existing sources (BAT)","table: Subpart H—Hydrofluoric Acid"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.83 (BAT)","page":null,"quote":"Fluoride (T) 3.4 1.6"}},{"id":"944f2f7db3e99413","parameter":"Fluoride (T)","value":"3.4","value_num":3.4,"unit":"Kg/kkg (or pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart H—Hydrofluoric Acid Production Subcategory","new sources (NSPS)","Any new source subject to this subpart must achieve the following new source performance standards (NSPS):","table: Subpart H—Hydrofluoric Acid"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.85 (NSPS)","page":null,"quote":"Fluoride (T) 3.4 1.6"}},{"id":"c97d760f0e4660cf","parameter":"Fluoride (T)","value":"1.6","value_num":1.6,"unit":"Kg/kkg (or pounds per 1,000 lb) of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart H—Hydrofluoric Acid Production Subcategory","new sources (NSPS)","Any new source subject to this subpart must achieve the following new source performance standards (NSPS):","table: Subpart H—Hydrofluoric Acid"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.85 (NSPS)","page":null,"quote":"Fluoride (T) 3.4 1.6"}},{"id":"b8673007a19d77b4","parameter":"Fluoride (T)","value":"100","value_num":100,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart H—Hydrofluoric Acid Production Subcategory","new sources (PSNS)","table: Subpart H—Hydrofluoric Acid"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.86 (PSNS)","page":null,"quote":"Fluoride (T) 100 50"}},{"id":"9bdce9ea67024f50","parameter":"Fluoride (T)","value":"50","value_num":50,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart H—Hydrofluoric Acid Production Subcategory","new sources (PSNS)","table: Subpart H—Hydrofluoric Acid"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.86 (PSNS)","page":null,"quote":"Fluoride (T) 100 50"}},{"id":"c99eee425ed0a18a","parameter":"Fluoride (T)","value":"1.3","value_num":1.3,"unit":"Kg/kkg (or pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart W—Aluminum Fluoride Production Subcategory","existing sources (BPT)","table: Subpart W—Aluminum Fluoride","column: Pollutant or pollutant property"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.232 (BPT)","page":null,"quote":"Fluoride (T) 1.3 0.63"}},{"id":"c50d131c3076009a","parameter":"Fluoride (T)","value":"0.63","value_num":0.63,"unit":"Kg/kkg (or pounds per 1,000 lb) of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart W—Aluminum Fluoride Production Subcategory","existing sources (BPT)","table: Subpart W—Aluminum Fluoride","column: Pollutant or pollutant property"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.232 (BPT)","page":null,"quote":"Fluoride (T) 1.3 0.63"}},{"id":"93a74b8f7a9d10af","parameter":"Fluoride","value":"50","value_num":50,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart BC—Sodium Fluoride Production Subcategory","existing sources (PSES)","table: Subpart BC—Sodium Fluoride"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.554 (PSES)","page":null,"quote":"Fluoride 50 25"}},{"id":"555d5928fb73a10f","parameter":"Fluoride","value":"25","value_num":25,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart BC—Sodium Fluoride Production Subcategory","existing sources (PSES)","table: Subpart BC—Sodium Fluoride"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.554 (PSES)","page":null,"quote":"Fluoride 50 25"}},{"id":"78fefd296ee3b542","parameter":"Fluoride","value":"75","value_num":75,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 418","the discharge is of the Subpart A—Phosphate Subcategory","existing sources (BPT)","(c) The concentration of pollutants discharged in process wastewater pursuant to the limitations of paragraph (b) shall not exceed the values listed in the following table:"],"cite":{"instrument":"us_40cfr418","title":"40 CFR Part 418 — PART 418—FERTILIZER MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=418","source_sha256":"881822302cd9912ec4678ba7ccaa00276ff06f33a48ae154f399db6986c1ffda","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 418.12 (BPT)","page":null,"quote":"Fluoride 75 25"}},{"id":"a258d2e3db510666","parameter":"Fluoride","value":"25","value_num":25,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 418","the discharge is of the Subpart A—Phosphate Subcategory","existing sources (BPT)","(c) The concentration of pollutants discharged in process wastewater pursuant to the limitations of paragraph (b) shall not exceed the values listed in the following table:"],"cite":{"instrument":"us_40cfr418","title":"40 CFR Part 418 — PART 418—FERTILIZER MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=418","source_sha256":"881822302cd9912ec4678ba7ccaa00276ff06f33a48ae154f399db6986c1ffda","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 418.12 (BPT)","page":null,"quote":"Fluoride 75 25"}},{"id":"788af66f12cd0dbb","parameter":"Fluoride","value":"75","value_num":75,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 418","the discharge is of the Subpart A—Phosphate Subcategory","existing sources (BPT)","(d) The concentration of pollutants discharged in contaminated non-process wastewater shall not exceed the values listed in the following table:"],"cite":{"instrument":"us_40cfr418","title":"40 CFR Part 418 — PART 418—FERTILIZER MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=418","source_sha256":"881822302cd9912ec4678ba7ccaa00276ff06f33a48ae154f399db6986c1ffda","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 418.12 (BPT)","page":null,"quote":"Fluoride 75 25"}},{"id":"634d0b789c2b1571","parameter":"Fluoride","value":"25","value_num":25,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 418","the discharge is of the Subpart A—Phosphate Subcategory","existing sources (BPT)","(d) The concentration of pollutants discharged in contaminated non-process wastewater shall not exceed the values listed in the following table:"],"cite":{"instrument":"us_40cfr418","title":"40 CFR Part 418 — PART 418—FERTILIZER MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=418","source_sha256":"881822302cd9912ec4678ba7ccaa00276ff06f33a48ae154f399db6986c1ffda","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 418.12 (BPT)","page":null,"quote":"Fluoride 75 25"}},{"id":"659b6e3ec04fba28","parameter":"Fluoride","value":"75","value_num":75,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 418","the discharge is of the Subpart A—Phosphate Subcategory","existing sources (BAT)","(c) The concentration of pollutants discharged in process wastewater pursuant to the limitations of paragraph (b) of this section shall not exceed the values listed in the following table:"],"cite":{"instrument":"us_40cfr418","title":"40 CFR Part 418 — PART 418—FERTILIZER MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=418","source_sha256":"881822302cd9912ec4678ba7ccaa00276ff06f33a48ae154f399db6986c1ffda","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 418.13 (BAT)","page":null,"quote":"Fluoride 75 25"}},{"id":"d75118162142a1e5","parameter":"Fluoride","value":"25","value_num":25,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 418","the discharge is of the Subpart A—Phosphate Subcategory","existing sources (BAT)","(c) The concentration of pollutants discharged in process wastewater pursuant to the limitations of paragraph (b) of this section shall not exceed the values listed in the following table:"],"cite":{"instrument":"us_40cfr418","title":"40 CFR Part 418 — PART 418—FERTILIZER MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=418","source_sha256":"881822302cd9912ec4678ba7ccaa00276ff06f33a48ae154f399db6986c1ffda","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 418.13 (BAT)","page":null,"quote":"Fluoride 75 25"}},{"id":"348ffd17c4893b88","parameter":"Fluoride","value":"75","value_num":75,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 418","the discharge is of the Subpart A—Phosphate Subcategory","existing sources (BAT)","(d) The concentration of pollutants discharged in contaminated non-process wastewater shall not exceed the values listed in the following table:"],"cite":{"instrument":"us_40cfr418","title":"40 CFR Part 418 — PART 418—FERTILIZER MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=418","source_sha256":"881822302cd9912ec4678ba7ccaa00276ff06f33a48ae154f399db6986c1ffda","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 418.13 (BAT)","page":null,"quote":"Fluoride 75 25"}},{"id":"0744bf4cff3eccf0","parameter":"Fluoride","value":"25","value_num":25,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 418","the discharge is of the Subpart A—Phosphate Subcategory","existing sources (BAT)","(d) The concentration of pollutants discharged in contaminated non-process wastewater shall not exceed the values listed in the following table:"],"cite":{"instrument":"us_40cfr418","title":"40 CFR Part 418 — PART 418—FERTILIZER MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=418","source_sha256":"881822302cd9912ec4678ba7ccaa00276ff06f33a48ae154f399db6986c1ffda","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 418.13 (BAT)","page":null,"quote":"Fluoride 75 25"}},{"id":"0793cbb06822cafd","parameter":"Fluoride","value":"75","value_num":75,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 418","the discharge is of the Subpart A—Phosphate Subcategory","new sources (NSPS)","(c) The concentration of pollutants discharged in process wastewater pursuant to the limitations of paragraph (b) shall not exceed the values listed in the following table:"],"cite":{"instrument":"us_40cfr418","title":"40 CFR Part 418 — PART 418—FERTILIZER MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=418","source_sha256":"881822302cd9912ec4678ba7ccaa00276ff06f33a48ae154f399db6986c1ffda","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 418.15 (NSPS)","page":null,"quote":"Fluoride 75 25"}},{"id":"be5e877a22e50baa","parameter":"Fluoride","value":"25","value_num":25,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 418","the discharge is of the Subpart A—Phosphate Subcategory","new sources (NSPS)","(c) The concentration of pollutants discharged in process wastewater pursuant to the limitations of paragraph (b) shall not exceed the values listed in the following table:"],"cite":{"instrument":"us_40cfr418","title":"40 CFR Part 418 — PART 418—FERTILIZER MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=418","source_sha256":"881822302cd9912ec4678ba7ccaa00276ff06f33a48ae154f399db6986c1ffda","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 418.15 (NSPS)","page":null,"quote":"Fluoride 75 25"}},{"id":"7b14c2d38b107652","parameter":"Fluoride","value":"75","value_num":75,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 418","the discharge is of the Subpart A—Phosphate Subcategory","new sources (NSPS)","(d) The concentration of pollutants discharged in contaminated non-process wastewater shall not exceed the values listed in the following table:"],"cite":{"instrument":"us_40cfr418","title":"40 CFR Part 418 — PART 418—FERTILIZER MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=418","source_sha256":"881822302cd9912ec4678ba7ccaa00276ff06f33a48ae154f399db6986c1ffda","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 418.15 (NSPS)","page":null,"quote":"Fluoride 75 25"}},{"id":"951d822c3bd0a149","parameter":"Fluoride","value":"25","value_num":25,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 418","the discharge is of the Subpart A—Phosphate Subcategory","new sources (NSPS)","(d) The concentration of pollutants discharged in contaminated non-process wastewater shall not exceed the values listed in the following table:"],"cite":{"instrument":"us_40cfr418","title":"40 CFR Part 418 — PART 418—FERTILIZER MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=418","source_sha256":"881822302cd9912ec4678ba7ccaa00276ff06f33a48ae154f399db6986c1ffda","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 418.15 (NSPS)","page":null,"quote":"Fluoride 75 25"}},{"id":"49960e705523a119","parameter":"Fluoride","value":"2.0","value_num":2,"unit":"kg/kkg of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.22 (BPT)","page":null,"quote":"Fluoride 2.0 1.0"}},{"id":"66058426c1fc589e","parameter":"Fluoride","value":"1.0","value_num":1,"unit":"kg/kkg of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.22 (BPT)","page":null,"quote":"Fluoride 2.0 1.0"}},{"id":"6b575f865c0406cc","parameter":"Fluoride","value":"8.092","value_num":8.092,"unit":"mg/kg (pounds per million pounds) of paste produced","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(a) Subpart B—Anode and Cathode Paste Plant Wet Air Pollution Control","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 8.092 3.591"}},{"id":"ac694704e8e2fb59","parameter":"Fluoride","value":"3.591","value_num":3.591,"unit":"mg/kg (pounds per million pounds) of paste produced","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(a) Subpart B—Anode and Cathode Paste Plant Wet Air Pollution Control","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 8.092 3.591"}},{"id":"f4502ef6698a6c28","parameter":"Fluoride","value":"12.440","value_num":12.44,"unit":"mg/kg (pounds per million pounds) of anodes cast","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(b) Subpart (B)—Anode Contact Cooling and Briquette Quenching.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 12.440 5.518"}},{"id":"a02eb324dbee535b","parameter":"Fluoride","value":"5.518","value_num":5.518,"unit":"mg/kg (pounds per million pounds) of anodes cast","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(b) Subpart (B)—Anode Contact Cooling and Briquette Quenching.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 12.440 5.518"}},{"id":"6ce05cee1e81bdb2","parameter":"Fluoride","value":"257.300","value_num":257.3,"unit":"mg/kg (pounds per million pounds) of anodes baked","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(c) Subpart (B)—Anode Bake Plant Wet Air Pollution Control (Closed Top Ring Furnace).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 257.300 114.200"}},{"id":"6e25ff9ffa2cd046","parameter":"Fluoride","value":"114.200","value_num":114.2,"unit":"mg/kg (pounds per million pounds) of anodes baked","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(c) Subpart (B)—Anode Bake Plant Wet Air Pollution Control (Closed Top Ring Furnace).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 257.300 114.200"}},{"id":"bd70de9aed434bb3","parameter":"Fluoride","value":"2.975","value_num":2.975,"unit":"mg/kg (pounds per million pounds) of anodes baked","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(d) Subpart B—Anode Bake Plant Wet Air Pollution Control (Open Top Ring Furnace With Spray Tower Only).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 2.975 1.320"}},{"id":"d1e5d91e255886d4","parameter":"Fluoride","value":"1.320","value_num":1.32,"unit":"mg/kg (pounds per million pounds) of anodes baked","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(d) Subpart B—Anode Bake Plant Wet Air Pollution Control (Open Top Ring Furnace With Spray Tower Only).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 2.975 1.320"}}],"next":[{"tool":"check_values","says":"Has your user measured this? check_values sets each of their results beside every row held here, with a verdict and the row's cite.","arguments":{"place":"US-FL"},"needs":{"rows":"Your user's measured results, as their table prints them: [{parameter: \"fluoride\", value, unit}, ...], any other parameters too."},"post":"/api/v1/check"},{"tool":"read_certificate","says":"Has your user a laboratory certificate? read_certificate reads every row it prints, each with its page, and checks them against these limits.","arguments":{"place":"US-FL"},"needs":{"content_base64":"The laboratory's certificate (PDF) or its XLSX, XLS or CSV export, as base64; or file_url, a public https address of it."},"post":"/api/v1/certificate"}]}