{"query":{"parameter":"fluoranthene","place":"US-LA","medium":null,"statistic":null,"kind":null},"searched":{"places":["US-LA","US"],"parameter_keys":["cas:206-44-0","cas:205-99-2","name:benzo(b) fluoranthene","cas:205-82-3","cas:207-08-9","name:benzo(k) fluoranthene","name:polycyclic aromatic hydrocarbons, total of ten (acenaphthylene, benzo(a)anthracene, benzo(a)pyrene, benzo(b)fluoranthene, benzo(ghi)perylene, benzo(k)fluoranthene, chrysene, dibenzo(a,h)anthracene, indeno(1,2,3-cd)pyrene, phenanthrene)","name:sommation de hap","name:benzo (b) fluorantene","name:benzo (k,) fluorantene"],"names_matched":[["fluoranthene","cas:206-44-0"],["3 4 benzo fluoranthene benzo b fluoranthene","cas:205-99-2"],["3 4 benzofluoranthene benzo b fluoranthene","cas:205-99-2"],["benzo b fluoranthene","cas:205-99-2"],["benzo b fluoranthene","name:benzo(b) fluoranthene"],["benzo b fluoranthene 3 4","cas:205-99-2"],["benzo b fluoranthene pah","cas:205-99-2"],["benzo b fluoranthene pah 3 4 benzofluoranthene","cas:205-99-2"],["benzo b fluoranthene pah also known as 3 4 benzofluoranthene","cas:205-99-2"],["benzo j fluoranthene","cas:205-82-3"],["benzo k fluoranthene","cas:207-08-9"],["benzo k fluoranthene","name:benzo(k) fluoranthene"],["benzo k fluoranthene pah","cas:207-08-9"],["benzo k fluoranthene pah 11 12 benzofluoranthene","cas:207-08-9"],["pah benzo b fluoranthene","cas:205-99-2"],["pah benzo k fluoranthene","cas:207-08-9"],["polycyclic aromatic hydrocarbons total of ten acenaphthylene benzo a anthracene benzo a pyrene benzo b fluoranthene benzo ghi perylene benzo k fluoranthene chrysene dibenzo a h anthracene indeno 1 2 3 cd pyrene phenanthrene","name:polycyclic aromatic hydrocarbons, total of ten (acenaphthylene, benzo(a)anthracene, benzo(a)pyrene, benzo(b)fluoranthene, benzo(ghi)perylene, benzo(k)fluoranthene, chrysene, dibenzo(a,h)anthracene, indeno(1,2,3-cd)pyrene, phenanthrene)"],["sommation de hap benzo a anthracene benzo b fluoranthene benzo k fluoranthene benzo a pyrene chrysene dibenzo a h anthracene et indeno 1 2 3 c d pyrene","name:sommation de hap"],["benzo b fluorantene","cas:205-99-2","fluorantene"],["benzo b fluorantene","name:benzo (b) fluorantene","fluorantene"],["benzo k fluorantene","cas:207-08-9","fluorantene"],["benzo k fluorantene","name:benzo (k,) fluorantene","fluorantene"],["benzo b fluoranthen","cas:205-99-2","fluoranthen"],["benzo k fluoranthen","cas:207-08-9","fluoranthen"]],"match":"exact+contains","order":"The place's own instruments first, then each place above it, each in its register's order; rows for a marine receiving water after the rest, as none of the place's own rows names a marine, salt, estuarine, coastal or ocean water","not_sent":{"rows":8,"names":["3,4-Benzofluoranthene"],"says":"8 rows share a parameter key with a longer name holding \"fluoranthene\" but are printed under names without these words (that key is wider than the name): not sent. Ask for one by its name or CAS number."}},"total":76,"offset":0,"returned":50,"next_offset":50,"rows":[{"id":"c6b54516bfa08b38","parameter":"Polynuclear aromatic hydrocarbons [7]","value":"25.0","value_num":25,"unit":"lb/yr","direction":"max","kind":"threshold","medium":"air_emission","level":"regional","parameter_key":"cas:206-44-0","place":["US-LA"],"conditions":["the source is a major source of toxic air pollutants (5103)"],"cite":{"instrument":"us_la_lac33_iii_5112","title":"LAC 33:III.5112 — Toxic air pollutants: minimum emission rates (Table 51.1) and ambient air standards (Table 51.2)","issuer":null,"edition":"LII transcription of LAC 33:III.5112 (fetched 2026-09-25)","source_url":"https://www.law.cornell.edu/regulations/louisiana/La-Admin-Code-tit-33-SS-III-5112","source_sha256":"ad168892d6da7f3e8eda05d066b3cf2a0018d9fefcd81676abc7ca5110cca6dc","fetched_at":"2026-09-25","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"Table 51.1 Class II","page":null,"quote":"Polynuclear aromatic hydrocarbons [7] 206-44-0 PAHs 25.0"}},{"id":"24d26baf1035f366","parameter":"Polynuclear aromatic hydrocarbons [7]","value":"0.06","value_num":0.06,"unit":"µg/m³","statistic":"annual_avg","direction":"max","kind":"limit","medium":"ambient_air","level":"regional","parameter_key":"cas:206-44-0","place":["US-LA"],"conditions":["a major source at or above the minimum emission rate demonstrates it (5109.B)"],"cite":{"instrument":"us_la_lac33_iii_5112","title":"LAC 33:III.5112 — Toxic air pollutants: minimum emission rates (Table 51.1) and ambient air standards (Table 51.2)","issuer":null,"edition":"LII transcription of LAC 33:III.5112 (fetched 2026-09-25)","source_url":"https://www.law.cornell.edu/regulations/louisiana/La-Admin-Code-tit-33-SS-III-5112","source_sha256":"ad168892d6da7f3e8eda05d066b3cf2a0018d9fefcd81676abc7ca5110cca6dc","fetched_at":"2026-09-25","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"Table 51.2 Class II","page":null,"quote":"Polynuclear aromatic hydrocarbons [7] 206-44-0 II 0.06"}},{"id":"d912c7723efbba3d","parameter":"Fluoranthene","value":"68","value_num":68,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:206-44-0","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment","existing sources (BAT)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.91 (BAT)","page":null,"quote":"Fluoranthene 68 25"}},{"id":"6bfeede21e6710cf","parameter":"Fluoranthene","value":"68","value_num":68,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:206-44-0","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment","new sources (NSPS)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.91 (NSPS)","page":null,"quote":"Fluoranthene 68 25"}},{"id":"6861caa9357fc7a8","parameter":"Fluoranthene","value":"25","value_num":25,"unit":"µg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:206-44-0","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment","existing sources (BAT)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.91 (BAT)","page":null,"quote":"Fluoranthene 68 25"}},{"id":"11d2d56fa2f87efd","parameter":"Fluoranthene","value":"25","value_num":25,"unit":"µg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:206-44-0","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment","new sources (NSPS)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.91 (NSPS)","page":null,"quote":"Fluoranthene 68 25"}},{"id":"fe941962ffc913e8","parameter":"Fluoranthene","value":"54","value_num":54,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:206-44-0","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment","existing sources (BAT)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.101 (BAT)","page":null,"quote":"Fluoranthene 54 22"}},{"id":"b8cd7354c4f08bfa","parameter":"Fluoranthene","value":"54","value_num":54,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:206-44-0","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment","new sources (NSPS)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.101 (NSPS)","page":null,"quote":"Fluoranthene 54 22"}},{"id":"b564771202c28705","parameter":"Fluoranthene","value":"22","value_num":22,"unit":"µg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:206-44-0","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment","existing sources (BAT)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.101 (BAT)","page":null,"quote":"Fluoranthene 54 22"}},{"id":"19995596d5eb3787","parameter":"Fluoranthene","value":"22","value_num":22,"unit":"µg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:206-44-0","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment","new sources (NSPS)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.101 (NSPS)","page":null,"quote":"Fluoranthene 54 22"}},{"id":"49d0d4e4b8abb43a","parameter":"Fluoranthene","value":"54","value_num":54,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:206-44-0","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is sewer","cites is 40 CFR 414","the discharge is of the Subpart K—Indirect Discharge Point Sources","new sources (PSNS)","(b) In the case of lead, zinc, and total cyanide the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for metals and times the flow from the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste streams are defined…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.111 (PSNS)","page":null,"quote":"Fluoranthene 54 22"}},{"id":"9f6c813788156e03","parameter":"Fluoranthene","value":"22","value_num":22,"unit":"µg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:206-44-0","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is sewer","cites is 40 CFR 414","the discharge is of the Subpart K—Indirect Discharge Point Sources","new sources (PSNS)","(b) In the case of lead, zinc, and total cyanide the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for metals and times the flow from the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste streams are defined…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.111 (PSNS)","page":null,"quote":"Fluoranthene 54 22"}},{"id":"2548b12262d45317","parameter":"Fluoranthene","value":"0.0537","value_num":0.0537,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:206-44-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 437","the discharge is of the Subpart B—Oils Treatment and Recovery","existing sources (BPT)","table: BPT Limitations"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.21 (BPT)","page":null,"quote":"Fluoranthene 0.0537 0.0268"}},{"id":"a86877e0dec5a591","parameter":"Fluoranthene","value":"0.0268","value_num":0.0268,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:206-44-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 437","the discharge is of the Subpart B—Oils Treatment and Recovery","existing sources (BPT)","table: BPT Limitations"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.21 (BPT)","page":null,"quote":"Fluoranthene 0.0537 0.0268"}},{"id":"83fb7d501b6ed314","parameter":"Fluoranthene","value":"0.787","value_num":0.787,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:206-44-0","place":["US"],"conditions":["route is sewer","cites is 40 CFR 437","the discharge is of the Subpart B—Oils Treatment and Recovery","existing sources (PSES)","table: Pretreatment Standards (PSES)"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.25 (PSES)","page":null,"quote":"Fluoranthene 0.787 0.393"}},{"id":"e5e234a6c01cc588","parameter":"Fluoranthene","value":"0.393","value_num":0.393,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:206-44-0","place":["US"],"conditions":["route is sewer","cites is 40 CFR 437","the discharge is of the Subpart B—Oils Treatment and Recovery","existing sources (PSES)","table: Pretreatment Standards (PSES)"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.25 (PSES)","page":null,"quote":"Fluoranthene 0.787 0.393"}},{"id":"2a69bfb139a46a4a","parameter":"Fluoranthene","value":"0.0537","value_num":0.0537,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:206-44-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","existing sources (BPT)","(b) Combined waste receipts from subparts A, B, and C of this part. (1) As provided in § 437.42(a), any existing point source subject to this paragraph must achieve the following effluent limitations representing the application of BPT:","table: BPT Limitations"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.42 (BPT)","page":null,"quote":"Fluoranthene 0.0537 0.0268"}},{"id":"d0d9f1955773e476","parameter":"Fluoranthene","value":"0.0268","value_num":0.0268,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:206-44-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","existing sources (BPT)","(b) Combined waste receipts from subparts A, B, and C of this part. (1) As provided in § 437.42(a), any existing point source subject to this paragraph must achieve the following effluent limitations representing the application of BPT:","table: BPT Limitations"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.42 (BPT)","page":null,"quote":"Fluoranthene 0.0537 0.0268"}},{"id":"df583ced4acb314f","parameter":"Fluoranthene","value":"0.0537","value_num":0.0537,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:206-44-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","existing sources (BPT)","(c) Combined waste receipts from subparts A and B of this part. (1) As provided in § 437.42(a), any existing point source subject to this paragraph must achieve the following effluent limitations representing the application of BPT:","table: BPT Limitations"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.42 (BPT)","page":null,"quote":"Fluoranthene 0.0537 0.0268"}},{"id":"31cfae03703077f3","parameter":"Fluoranthene","value":"0.0268","value_num":0.0268,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:206-44-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","existing sources (BPT)","(c) Combined waste receipts from subparts A and B of this part. (1) As provided in § 437.42(a), any existing point source subject to this paragraph must achieve the following effluent limitations representing the application of BPT:","table: BPT Limitations"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.42 (BPT)","page":null,"quote":"Fluoranthene 0.0537 0.0268"}},{"id":"fe80c2cdffb616c6","parameter":"Fluoranthene","value":"0.0537","value_num":0.0537,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:206-44-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","existing sources (BPT)","(e) Combined waste receipts from subparts B and C of this part. As provided in § 437.42(a), any existing point source subject to this paragraph must achieve the following effluent limitations representing the application of BPT:","table: BPT Limitations"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.42 (BPT)","page":null,"quote":"Fluoranthene 0.0537 0.0268"}},{"id":"9d054ad4e3affa3a","parameter":"Fluoranthene","value":"0.0268","value_num":0.0268,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:206-44-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","existing sources (BPT)","(e) Combined waste receipts from subparts B and C of this part. As provided in § 437.42(a), any existing point source subject to this paragraph must achieve the following effluent limitations representing the application of BPT:","table: BPT Limitations"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.42 (BPT)","page":null,"quote":"Fluoranthene 0.0537 0.0268"}},{"id":"e8677fd425b7f226","parameter":"Fluoranthene","value":"0.0537","value_num":0.0537,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:206-44-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","new sources (NSPS)","(b) Combined waste receipts from subparts A, B and C of this part. (1) As provided in § 437.45(a), any new source subject to this paragraph must achieve the following performance standards:","table: Performance Standards"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.45 (NSPS)","page":null,"quote":"Fluoranthene 0.0537 0.0268"}},{"id":"9453ebacc05db0b0","parameter":"Fluoranthene","value":"0.0268","value_num":0.0268,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:206-44-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","new sources (NSPS)","(b) Combined waste receipts from subparts A, B and C of this part. (1) As provided in § 437.45(a), any new source subject to this paragraph must achieve the following performance standards:","table: Performance Standards"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.45 (NSPS)","page":null,"quote":"Fluoranthene 0.0537 0.0268"}},{"id":"c01fe71de46e5027","parameter":"Fluoranthene","value":"0.0537","value_num":0.0537,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:206-44-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","new sources (NSPS)","(c) Combined waste receipts from subparts A and B of this part. (1) As provided in § 437.45(a), any new source subject to this paragraph must achieve the following standards:","table: Performance Standards"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.45 (NSPS)","page":null,"quote":"Fluoranthene 0.0537 0.0268"}},{"id":"acf75d7b374891da","parameter":"Fluoranthene","value":"0.0268","value_num":0.0268,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:206-44-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","new sources (NSPS)","(c) Combined waste receipts from subparts A and B of this part. (1) As provided in § 437.45(a), any new source subject to this paragraph must achieve the following standards:","table: Performance Standards"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.45 (NSPS)","page":null,"quote":"Fluoranthene 0.0537 0.0268"}},{"id":"e5d91ff0acd5896f","parameter":"Fluoranthene","value":"0.0537","value_num":0.0537,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:206-44-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","new sources (NSPS)","(e) Combined waste receipts from subparts B and C of this part. As provided in § 437.45(a), any new source subject to this paragraph must achieve the following performance standards:","table: Performance Standards"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.45 (NSPS)","page":null,"quote":"Fluoranthene 0.0537 0.0268"}},{"id":"24131d18527112e1","parameter":"Fluoranthene","value":"0.0268","value_num":0.0268,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:206-44-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","new sources (NSPS)","(e) Combined waste receipts from subparts B and C of this part. As provided in § 437.45(a), any new source subject to this paragraph must achieve the following performance standards:","table: Performance Standards"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.45 (NSPS)","page":null,"quote":"Fluoranthene 0.0537 0.0268"}},{"id":"cc757cd7626cf770","parameter":"Fluoranthene","value":"0.787","value_num":0.787,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:206-44-0","place":["US"],"conditions":["route is sewer","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","existing sources (PSES)","(b) Combined waste receipts from subparts A, B and C of this part. (1) As provided in § 437.46(a), and no later than [Insert date—three years after publication], any existing source subject to this paragraph must achieve the following pretreatment standards:","table: Pretreatment Standards (PSES)"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.46 (PSES)","page":null,"quote":"Fluoranthene 0.787 0.393"}},{"id":"3e815b22467f45bb","parameter":"Fluoranthene","value":"0.393","value_num":0.393,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:206-44-0","place":["US"],"conditions":["route is sewer","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","existing sources (PSES)","(b) Combined waste receipts from subparts A, B and C of this part. (1) As provided in § 437.46(a), and no later than [Insert date—three years after publication], any existing source subject to this paragraph must achieve the following pretreatment standards:","table: Pretreatment Standards (PSES)"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.46 (PSES)","page":null,"quote":"Fluoranthene 0.787 0.393"}},{"id":"94158ca89c7b95b8","parameter":"Fluoranthene","value":"0.787","value_num":0.787,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:206-44-0","place":["US"],"conditions":["route is sewer","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","existing sources (PSES)","(c) Combined waste receipts from subparts A and B of this part. (1) As provided in § 437.46(a), and no later than December 22, 2003, any existing source subject to this paragraph must achieve the following pretreatment standards:","table: Pretreatment Standards (PSES)"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.46 (PSES)","page":null,"quote":"Fluoranthene 0.787 0.393"}},{"id":"de3b473b7402fd52","parameter":"Fluoranthene","value":"0.393","value_num":0.393,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:206-44-0","place":["US"],"conditions":["route is sewer","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","existing sources (PSES)","(c) Combined waste receipts from subparts A and B of this part. (1) As provided in § 437.46(a), and no later than December 22, 2003, any existing source subject to this paragraph must achieve the following pretreatment standards:","table: Pretreatment Standards (PSES)"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.46 (PSES)","page":null,"quote":"Fluoranthene 0.787 0.393"}},{"id":"a2c8b8566e618a73","parameter":"Fluoranthene","value":"0.787","value_num":0.787,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:206-44-0","place":["US"],"conditions":["route is sewer","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","existing sources (PSES)","(e) Combined waste receipts from subparts B and C of this part. As provided in § 437.46(a), and no later than December 22, 2003, any existing source subject to this paragraph must achieve the following pretreatment standards:","table: Pretreatment Standards (PSES)"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.46 (PSES)","page":null,"quote":"Fluoranthene 0.787 0.393"}},{"id":"c48057b0fcad4d34","parameter":"Fluoranthene","value":"0.393","value_num":0.393,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:206-44-0","place":["US"],"conditions":["route is sewer","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","existing sources (PSES)","(e) Combined waste receipts from subparts B and C of this part. As provided in § 437.46(a), and no later than December 22, 2003, any existing source subject to this paragraph must achieve the following pretreatment standards:","table: Pretreatment Standards (PSES)"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.46 (PSES)","page":null,"quote":"Fluoranthene 0.787 0.393"}},{"id":"faa2ccba7acbbff4","parameter":"Fluoranthene","value":"0.0537","value_num":0.0537,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:206-44-0","place":["US"],"conditions":["route is sewer","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","new sources (PSNS)","(b) Combined waste receipts from subparts A, B and C of this part. (1) As provided in § 437.47(a), any new source subject to this paragraph must achieve the following pretreatment standards:","table: Pretreatment Standards (PSNS)"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.47 (PSNS)","page":null,"quote":"Fluoranthene 0.0537 0.0268"}},{"id":"f6c534ca71e352e5","parameter":"Fluoranthene","value":"0.0268","value_num":0.0268,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:206-44-0","place":["US"],"conditions":["route is sewer","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","new sources (PSNS)","(b) Combined waste receipts from subparts A, B and C of this part. (1) As provided in § 437.47(a), any new source subject to this paragraph must achieve the following pretreatment standards:","table: Pretreatment Standards (PSNS)"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.47 (PSNS)","page":null,"quote":"Fluoranthene 0.0537 0.0268"}},{"id":"fe9f3c05b0b7eb86","parameter":"Fluoranthene","value":"0.0537","value_num":0.0537,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:206-44-0","place":["US"],"conditions":["route is sewer","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","new sources (PSNS)","(c) Combined waste receipts from subparts A and B of this part. (1) As provided in § 437.47(a), any new source subject to this paragraph must achieve the following pretreatment standards:","table: Pretreatment Standards (PSNS)"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.47 (PSNS)","page":null,"quote":"Fluoranthene 0.0537 0.0268"}},{"id":"954415e71bdfa939","parameter":"Fluoranthene","value":"0.0268","value_num":0.0268,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:206-44-0","place":["US"],"conditions":["route is sewer","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","new sources (PSNS)","(c) Combined waste receipts from subparts A and B of this part. (1) As provided in § 437.47(a), any new source subject to this paragraph must achieve the following pretreatment standards:","table: Pretreatment Standards (PSNS)"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.47 (PSNS)","page":null,"quote":"Fluoranthene 0.0537 0.0268"}},{"id":"5cd1fb22798f5ebc","parameter":"Fluoranthene","value":"0.0537","value_num":0.0537,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:206-44-0","place":["US"],"conditions":["route is sewer","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","new sources (PSNS)","(e) Combined waste receipts from subparts B and C of this part. As provided in § 437.47(a), any new source subject to this paragraph must achieve the following pretreatment standards:","table: Pretreatment Standards (PSNS)"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.47 (PSNS)","page":null,"quote":"Fluoranthene 0.0537 0.0268"}},{"id":"d8a39f81b418ca55","parameter":"Fluoranthene","value":"0.0268","value_num":0.0268,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:206-44-0","place":["US"],"conditions":["route is sewer","cites is 40 CFR 437","the discharge is of the Subpart D—Multiple Wastestreams","new sources (PSNS)","(e) Combined waste receipts from subparts B and C of this part. As provided in § 437.47(a), any new source subject to this paragraph must achieve the following pretreatment standards:","table: Pretreatment Standards (PSNS)"],"cite":{"instrument":"us_40cfr437","title":"40 CFR Part 437 — PART 437—THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=437","source_sha256":"8e0e010c4a042c3d2350a03bd7a7c8a98559afa3a2ffa45a702685c0621afd01","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 437.47 (PSNS)","page":null,"quote":"Fluoranthene 0.0537 0.0268"}},{"id":"fd6e9bb4988e3aa1","parameter":"Fluoranthene","value":"0.076","value_num":0.076,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:206-44-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 442","the discharge is of the Subpart B—Rail Tank Cars Transporting Chemical and Petroleum Cargos","existing sources (BPT)","table: Table—Effluent Limitations"],"cite":{"instrument":"us_40cfr442","title":"40 CFR Part 442 — PART 442—TRANSPORTATION EQUIPMENT CLEANING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=442","source_sha256":"9330b2255a5f7e74daf9175af898d9d28ae855a2560f50658d1bce4c6b8feded","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 442.21 (BPT)","page":null,"quote":"Fluoranthene 0.076"}},{"id":"571743ce3803001f","parameter":"Fluoranthene","value":"0.076","value_num":0.076,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:206-44-0","place":["US"],"conditions":["route is sewer","cites is 40 CFR 442","the discharge is of the Subpart B—Rail Tank Cars Transporting Chemical and Petroleum Cargos","existing sources (PSES)","table: Table—Pretreatment Standards'"],"cite":{"instrument":"us_40cfr442","title":"40 CFR Part 442 — PART 442—TRANSPORTATION EQUIPMENT CLEANING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=442","source_sha256":"9330b2255a5f7e74daf9175af898d9d28ae855a2560f50658d1bce4c6b8feded","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 442.25 (PSES)","page":null,"quote":"Fluoranthene 0.076"}},{"id":"2ba33199c4a57a9a","parameter":"Fluoranthene","value":"0.076","value_num":0.076,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:206-44-0","place":["US"],"conditions":["route is sewer","cites is 40 CFR 442","the discharge is of the Subpart B—Rail Tank Cars Transporting Chemical and Petroleum Cargos","new sources (PSNS)","table: Table—Pretreatment Standards"],"cite":{"instrument":"us_40cfr442","title":"40 CFR Part 442 — PART 442—TRANSPORTATION EQUIPMENT CLEANING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=442","source_sha256":"9330b2255a5f7e74daf9175af898d9d28ae855a2560f50658d1bce4c6b8feded","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 442.26 (PSNS)","page":null,"quote":"Fluoranthene 0.076"}},{"id":"3f9299a29d074ba0","parameter":"Fluoranthene","value":"20","value_num":20,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"national","parameter_key":"cas:206-44-0","place":["US"],"conditions":["EPA's recommendation under Clean Water Act § 304(a): 'State and Tribal governments may use these criteria or use them as guidance in developing their own' — it binds a water once the state adopts it for the water's designated use","receiving_water is freshwater","consumption of water + organism: a water designated a drinking-water source and for fish and shellfish (a designated use the state assigns)"],"cite":{"instrument":"us_nrwqc_human_health","title":"EPA National Recommended Water Quality Criteria — Human Health Criteria Table (water + organism, organism only)","issuer":"U.S. Environmental Protection Agency","edition":"EPA web table (fetched 2026-10-09); each criterion carries its publication year","source_url":"https://www.epa.gov/wqc/national-recommended-water-quality-criteria-human-health-criteria-table","source_sha256":"a0229d5a613672b46a000c5b9925dd3a23c3e05914bb020b7f739c69cecbb5fe","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"National Recommended Water Quality Criteria — Human Health Criteria Table","page":null,"quote":"Fluoranthene (P) 206440 20 20 2015"}},{"id":"99b3db138442c9f5","parameter":"Fluoranthene","value":"20","value_num":20,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"national","parameter_key":"cas:206-44-0","place":["US"],"conditions":["EPA's recommendation under Clean Water Act § 304(a): 'State and Tribal governments may use these criteria or use them as guidance in developing their own' — it binds a water once the state adopts it for the water's designated use","receiving_water is freshwater","consumption of organism only: a water designated for fish and shellfish taken from it, not a drinking-water source (fresh or salt)"],"cite":{"instrument":"us_nrwqc_human_health","title":"EPA National Recommended Water Quality Criteria — Human Health Criteria Table (water + organism, organism only)","issuer":"U.S. Environmental Protection Agency","edition":"EPA web table (fetched 2026-10-09); each criterion carries its publication year","source_url":"https://www.epa.gov/wqc/national-recommended-water-quality-criteria-human-health-criteria-table","source_sha256":"a0229d5a613672b46a000c5b9925dd3a23c3e05914bb020b7f739c69cecbb5fe","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"National Recommended Water Quality Criteria — Human Health Criteria Table","page":null,"quote":"Fluoranthene (P) 206440 20 20 2015"}},{"id":"2bce771b91a3fe19","parameter":"~Fluoranthene","value":"2400","value_num":2400,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"national","parameter_key":"cas:206-44-0","place":["US"],"conditions":["Resident Soil (mg/kg)"],"cite":{"instrument":"us_rsl_soil","title":"US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Soil","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"November 2024","source_url":"https://semspub.epa.gov/src/document/HQ/405270","source_sha256":"0160dc81b4f55d738a354a74de92488f149946ebfa7c6a6c64592f45348043d7","fetched_at":"2026-09-19","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":null,"page":null,"quote":null,"table":"sols","column":"residentiel"}},{"id":"8c8bf7064ec7c821","parameter":"~Fluoranthene","value":"30000","value_num":30000,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"national","parameter_key":"cas:206-44-0","place":["US"],"conditions":["Industrial Soil (mg/kg)"],"cite":{"instrument":"us_rsl_soil","title":"US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Soil","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"November 2024","source_url":"https://semspub.epa.gov/src/document/HQ/405270","source_sha256":"0160dc81b4f55d738a354a74de92488f149946ebfa7c6a6c64592f45348043d7","fetched_at":"2026-09-19","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":null,"page":null,"quote":null,"table":"sols","column":"industriel"}},{"id":"4fb2814d5e265e6d","parameter":"~Fluoranthene","value":"89","value_num":89,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"national","parameter_key":"cas:206-44-0","place":["US"],"conditions":["Protection of Groundwater SSLs: Risk-based SSL (mg/kg); SSL values are based on DAF=1"],"cite":{"instrument":"us_rsl_soil","title":"US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Soil","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"November 2024","source_url":"https://semspub.epa.gov/src/document/HQ/405270","source_sha256":"0160dc81b4f55d738a354a74de92488f149946ebfa7c6a6c64592f45348043d7","fetched_at":"2026-09-19","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":null,"page":null,"quote":null,"table":"ssl","column":"risque"}},{"id":"74958250f0f678ed","parameter":"~Fluoranthene","value":"800","value_num":800,"unit":"µg/L","direction":"max","kind":"guideline","medium":"drinking_water","level":"national","parameter_key":"cas:206-44-0","place":["US"],"conditions":["Tap Water (ug/L): Regional Screening Level (RSL) Summary Table (TR=1E-06, HQ=1) November 2024"],"cite":{"instrument":"us_rsl_tapwater","title":"US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Tap Water","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"November 2024","source_url":"https://semspub.epa.gov/src/document/HQ/405270","source_sha256":"0160dc81b4f55d738a354a74de92488f149946ebfa7c6a6c64592f45348043d7","fetched_at":"2026-09-19","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":null,"page":null,"quote":null,"table":"eau","column":"eau_robinet"}},{"id":"5ed543335e64327b","parameter":"Benzo(b)fluoranthene","value":"0.0012","value_num":0.0012,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"national","parameter_key":"cas:205-99-2","place":["US"],"conditions":["EPA's recommendation under Clean Water Act § 304(a): 'State and Tribal governments may use these criteria or use them as guidance in developing their own' — it binds a water once the state adopts it for the water's designated use","receiving_water is freshwater","consumption of water + organism: a water designated a drinking-water source and for fish and shellfish (a designated use the state assigns)"],"cite":{"instrument":"us_nrwqc_human_health","title":"EPA National Recommended Water Quality Criteria — Human Health Criteria Table (water + organism, organism only)","issuer":"U.S. Environmental Protection Agency","edition":"EPA web table (fetched 2026-10-09); each criterion carries its publication year","source_url":"https://www.epa.gov/wqc/national-recommended-water-quality-criteria-human-health-criteria-table","source_sha256":"a0229d5a613672b46a000c5b9925dd3a23c3e05914bb020b7f739c69cecbb5fe","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"National Recommended Water Quality Criteria — Human Health Criteria Table","page":null,"quote":"Benzo(b)fluoranthene (P) 205992 0.0012 0.0013 2015"}}],"next":[{"tool":"check_values","says":"Has your user measured this? check_values sets each of their results beside every row held here, with a verdict and the row's cite.","arguments":{"place":"US-LA"},"needs":{"rows":"Your user's measured results, as their table prints them: [{parameter: \"fluoranthene\", value, unit}, ...], any other parameters too."},"post":"/api/v1/check"},{"tool":"read_certificate","says":"Has your user a laboratory certificate? read_certificate reads every row it prints, each with its page, and checks them against these limits.","arguments":{"place":"US-LA"},"needs":{"content_base64":"The laboratory's certificate (PDF) or its XLSX, XLS or CSV export, as base64; or file_url, a public https address of it."},"post":"/api/v1/certificate"}]}