{"query":{"parameter":"demeton","place":"US-NY","medium":null,"statistic":null,"kind":null},"searched":{"places":["US-NY","US"],"parameter_keys":["cas:298-03-3","cas:8065-48-3"],"names_matched":[["demeton","cas:298-03-3"],["demeton","cas:8065-48-3"]],"match":"exact","order":"The place's own instruments first, then each place above it, each in its register's order"},"total":7,"offset":0,"returned":7,"next_offset":null,"rows":[{"id":"2dc28aa2eb73fa11","parameter":"Demeton","value":"0.1*","value_num":0.1,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:8065-48-3","place":["US-NY"],"conditions":["receiving_water is freshwater","New York classes A, A-S, AA, AA-S, B, C (fresh waters; 6 NYCRR Part 701)"],"cite":{"instrument":"us_ny_wqs","title":"6 NYCRR 703.5 Table 1 water quality standards (as DEC TOGS 1.1.1 reprints them) and 703.3 pH, dissolved oxygen and dissolved solids (New York)","issuer":"State of New York, Department of Environmental Conservation","edition":"DEC Division of Water TOGS 1.1.1, reissued June 1998 (the 703.5 standards as revised effective March 12, 1998); 703.3 from 6 NYCRR Parts 700-706 as US EPA posts them in effect for CWA purposes (effective December 20, 2024)","source_url":"https://dec.ny.gov/docs/water_pdf/togs111.pdf","source_sha256":"090692f43a82280ffbf75751ecc52b94fc2d5c78996f9dc2483152343f8f4d59","fetched_at":"2026-10-10","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"6 NYCRR 703.5(f) Table 1","page":28,"quote":"Demeton A, A-S, AA, AA-S, B, C 0.1* A(C)"}},{"id":"743d6fdc9eb0c3c6","parameter":"Demeton","value":"0.1","value_num":0.1,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:8065-48-3","place":["US-NY"],"conditions":["receiving_water is marine","New York classes SA, SB, SC (saline waters; 6 NYCRR Part 701)"],"cite":{"instrument":"us_ny_wqs","title":"6 NYCRR 703.5 Table 1 water quality standards (as DEC TOGS 1.1.1 reprints them) and 703.3 pH, dissolved oxygen and dissolved solids (New York)","issuer":"State of New York, Department of Environmental Conservation","edition":"DEC Division of Water TOGS 1.1.1, reissued June 1998 (the 703.5 standards as revised effective March 12, 1998); 703.3 from 6 NYCRR Parts 700-706 as US EPA posts them in effect for CWA purposes (effective December 20, 2024)","source_url":"https://dec.ny.gov/docs/water_pdf/togs111.pdf","source_sha256":"090692f43a82280ffbf75751ecc52b94fc2d5c78996f9dc2483152343f8f4d59","fetched_at":"2026-10-10","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"6 NYCRR 703.5(f) Table 1","page":28,"quote":"Demeton A, A-S, AA, AA-S, B, C 0.1* A(C) (8065-48-3; 298-03-3; 126-75-0) SA, SB, SC 0.1 A(C)"}},{"id":"26b1d419ef3aaf30","parameter":"Demeton","value":"0.1","value_num":0.1,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"national","parameter_key":"cas:8065-48-3","place":["US"],"conditions":["EPA's recommendation under Clean Water Act § 304(a): 'State and Tribal governments may use these criteria or use them as guidance in developing their own' — it binds a water once the state adopts it for the water's designated use","receiving_water is freshwater","Freshwater CCC (chronic): criterion continuous concentration, chronic"],"cite":{"instrument":"us_nrwqc_aquatic","title":"EPA National Recommended Water Quality Criteria — Aquatic Life Criteria Table (freshwater and saltwater CMC/CCC)","issuer":"U.S. Environmental Protection Agency","edition":"EPA web table, last updated on June 9, 2026 (fetched 2026-10-09); each criterion carries its publication year","source_url":"https://www.epa.gov/wqc/national-recommended-water-quality-criteria-aquatic-life-criteria-table","source_sha256":"be6b429558db9852c3456eb22c17046aa1a3335ee89e702e8afb793f9b5b25ec","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"National Recommended Aquatic Life Criteria table","page":null,"quote":"Demeton 8065483 — 0.1 — 0.1 1985"}},{"id":"82e544dcec6e46bb","parameter":"Demeton","value":"0.1","value_num":0.1,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"national","parameter_key":"cas:8065-48-3","place":["US"],"conditions":["EPA's recommendation under Clean Water Act § 304(a): 'State and Tribal governments may use these criteria or use them as guidance in developing their own' — it binds a water once the state adopts it for the water's designated use","receiving_water is marine","Saltwater CCC (chronic): criterion continuous concentration, chronic"],"cite":{"instrument":"us_nrwqc_aquatic","title":"EPA National Recommended Water Quality Criteria — Aquatic Life Criteria Table (freshwater and saltwater CMC/CCC)","issuer":"U.S. Environmental Protection Agency","edition":"EPA web table, last updated on June 9, 2026 (fetched 2026-10-09); each criterion carries its publication year","source_url":"https://www.epa.gov/wqc/national-recommended-water-quality-criteria-aquatic-life-criteria-table","source_sha256":"be6b429558db9852c3456eb22c17046aa1a3335ee89e702e8afb793f9b5b25ec","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"National Recommended Aquatic Life Criteria table","page":null,"quote":"Demeton 8065483 — 0.1 — 0.1 1985"}},{"id":"439845eeca618043","parameter":"Demeton","value":"2.5","value_num":2.5,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"national","parameter_key":"cas:8065-48-3","place":["US"],"conditions":["Resident Soil (mg/kg)"],"cite":{"instrument":"us_rsl_soil","title":"US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Soil","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"November 2024","source_url":"https://semspub.epa.gov/src/document/HQ/405270","source_sha256":"0160dc81b4f55d738a354a74de92488f149946ebfa7c6a6c64592f45348043d7","fetched_at":"2026-09-19","source_status":{"checked":"2026-10-15","status":"not verified"},"section":null,"page":null,"quote":null,"table":"sols","column":"residentiel"}},{"id":"b32d654bba8eb0f5","parameter":"Demeton","value":"33","value_num":33,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"national","parameter_key":"cas:8065-48-3","place":["US"],"conditions":["Industrial Soil (mg/kg)"],"cite":{"instrument":"us_rsl_soil","title":"US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Soil","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"November 2024","source_url":"https://semspub.epa.gov/src/document/HQ/405270","source_sha256":"0160dc81b4f55d738a354a74de92488f149946ebfa7c6a6c64592f45348043d7","fetched_at":"2026-09-19","source_status":{"checked":"2026-10-15","status":"not verified"},"section":null,"page":null,"quote":null,"table":"sols","column":"industriel"}},{"id":"63bfcdc67e5838b1","parameter":"Demeton","value":"0.42","value_num":0.42,"unit":"µg/L","direction":"max","kind":"guideline","medium":"drinking_water","level":"national","parameter_key":"cas:8065-48-3","place":["US"],"conditions":["Tap Water (ug/L): Regional Screening Level (RSL) Summary Table (TR=1E-06, HQ=1) November 2024"],"cite":{"instrument":"us_rsl_tapwater","title":"US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Tap Water","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"November 2024","source_url":"https://semspub.epa.gov/src/document/HQ/405270","source_sha256":"0160dc81b4f55d738a354a74de92488f149946ebfa7c6a6c64592f45348043d7","fetched_at":"2026-09-19","source_status":{"checked":"2026-10-15","status":"not verified"},"section":null,"page":null,"quote":null,"table":"eau","column":"eau_robinet"}}],"next":[{"tool":"check_values","says":"Has your user measured this? check_values sets each of their results beside every row held here, with a verdict and the row's cite.","arguments":{"place":"US-NY"},"needs":{"rows":"Your user's measured results, as their table prints them: [{parameter: \"demeton\", value, unit}, ...], any other parameters too."},"post":"/api/v1/check"},{"tool":"read_certificate","says":"Has your user a laboratory certificate? read_certificate reads every row it prints, each with its page, and checks them against these limits.","arguments":{"place":"US-NY"},"needs":{"content_base64":"The laboratory's certificate (PDF) or its XLSX, XLS or CSV export, as base64; or file_url, a public https address of it."},"post":"/api/v1/certificate"}]}