{"query":{"parameter":"cyanures totaux","place":"CA-QC","medium":null,"statistic":null,"kind":null},"searched":{"places":["CA-QC","CA"],"parameter_keys":["name:cyanures totaux","cas:57-12-5"],"names_matched":[["cyanures totaux","name:cyanures totaux"],["indice cyanures totaux","cas:57-12-5"]],"match":"exact+contains","order":"The place's own instruments first, then each place above it, each in its register's order","not_sent":{"rows":23,"names":["Cyanide","cyanures libres","Cyanure (sels solubles en CN)","Cyanures"],"says":"23 rows share a parameter key with a longer name holding \"cyanures totaux\" but are printed under names without these words (that key is wider than the name), or keyed to a CAS number \"cyanures totaux\" does not name (another substance, whatever words its name holds): not sent. Ask for one by its name or CAS number."}},"total":2,"offset":0,"returned":2,"next_offset":null,"rows":[{"id":"5a36ab494430f4f1","parameter":"Cyanures totaux","value":"0,5 mg/l","value_num":0.5,"unit":"mg/l","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"regional","route":"direct","stream":"any","parameter_key":"name:cyanures totaux","place":["CA-QC"],"conditions":["cites is Directive 019"],"cite":{"instrument":"ca_qc_d019","title":"Directive 019 sur l'industrie minière (février 2025) — tableau 3.1, exigences au point de rejet de l'effluent final","issuer":"Ministère de l'Environnement, de la Lutte contre les changements climatiques, de la Faune et des Parcs (MELCCFP)","edition":"février 2025","source_url":"https://www.environnement.gouv.qc.ca/milieu_ind/directive019/directive-019-2025.pdf","source_sha256":"3e46363df79aa14b684f360dc9b7f6172537079907e7bee50d0555abcbebe743","fetched_at":"2026-08-28","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":null,"page":19,"quote":null,"table":"tableau_3_1","column":"moyenne_mensuelle"}},{"id":"b82abee555385fba","parameter":"Cyanures totaux","value":"1 mg/l","value_num":1,"unit":"mg/l","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"regional","route":"direct","stream":"any","parameter_key":"name:cyanures totaux","place":["CA-QC"],"conditions":["cites is Directive 019"],"cite":{"instrument":"ca_qc_d019","title":"Directive 019 sur l'industrie minière (février 2025) — tableau 3.1, exigences au point de rejet de l'effluent final","issuer":"Ministère de l'Environnement, de la Lutte contre les changements climatiques, de la Faune et des Parcs (MELCCFP)","edition":"février 2025","source_url":"https://www.environnement.gouv.qc.ca/milieu_ind/directive019/directive-019-2025.pdf","source_sha256":"3e46363df79aa14b684f360dc9b7f6172537079907e7bee50d0555abcbebe743","fetched_at":"2026-08-28","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":null,"page":19,"quote":null,"table":"tableau_3_1","column":"quotidienne_max"}}],"next":[{"tool":"check_values","says":"Has your user measured this? check_values sets each of their results beside every row held here, with a verdict and the row's cite.","arguments":{"place":"CA-QC"},"needs":{"rows":"Your user's measured results, as their table prints them: [{parameter: \"cyanures totaux\", value, unit}, ...], any other parameters too."},"post":"/api/v1/check"},{"tool":"read_certificate","says":"Has your user a laboratory certificate? read_certificate reads every row it prints, each with its page, and checks them against these limits.","arguments":{"place":"CA-QC"},"needs":{"content_base64":"The laboratory's certificate (PDF) or its XLSX, XLS or CSV export, as base64; or file_url, a public https address of it."},"post":"/api/v1/certificate"}]}