{"query":{"parameter":"copper","place":"US-MS","medium":null,"statistic":null,"kind":null},"searched":{"places":["US-MS","US"],"parameter_keys":["cas:7440-50-8","name:arsenic, cadmium (h), copper (h), lead (h), mercury, zinc","name:arsenic, cadmium (h), copper (h), lead (h), zinc","name:cadmium (h), copper (h), mercury, lead (h), zinc","cas:68512-13-0","cas:544-92-3","name:copper - total","name:copper, total","name:copper, total recoverable","name:total copper","name:cuivre extractible"],"names_matched":[["copper","cas:7440-50-8"],["arsenic cadmium h copper h lead h mercury zinc","name:arsenic, cadmium (h), copper (h), lead (h), mercury, zinc"],["arsenic cadmium h copper h lead h mercury zinc h","name:arsenic, cadmium (h), copper (h), lead (h), mercury, zinc"],["arsenic cadmium h copper h lead h zinc","name:arsenic, cadmium (h), copper (h), lead (h), zinc"],["arsenic cadmium h copper h lead h zinc h","name:arsenic, cadmium (h), copper (h), lead (h), zinc"],["cadmium h copper h mercury lead h zinc","name:cadmium (h), copper (h), mercury, lead (h), zinc"],["cadmium h copper h mercury lead h zinc h","name:cadmium (h), copper (h), mercury, lead (h), zinc"],["copper 29h 31h phthalocyaninato 2 kappa n29 kappa n30 kappa n31 kappa n32 brominated chlorinated","cas:68512-13-0"],["copper cyanide","cas:544-92-3"],["copper cyanide cu cn","cas:544-92-3"],["copper cyanide cucn","cas:544-92-3"],["copper i cyanide","cas:544-92-3"],["copper total","name:copper - total"],["copper total","name:copper, total"],["copper total recoverable","name:copper, total recoverable"],["total copper","name:total copper"],["total copper freshwater","name:total copper"],["total copper marine","name:total copper"],["cuivre extractible","name:cuivre extractible","cuivre"]],"match":"exact+contains","order":"The place's own instruments first, then each place above it, each in its register's order"},"total":2383,"offset":0,"returned":50,"next_offset":50,"rows":[{"id":"7877f1f2b52bd47e","parameter":"Copper (dissolved)","value":"7.0 b,e","value_num":7,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-50-8","place":["US-MS"],"conditions":["receiving_water is freshwater","hardness 50 mg/l as CaCO3 (note b: the values in Table 2 are based on an in-stream hardness of 50 mg/l; other hardness takes the equations of EPA's Quality Criteria for Water)"],"cite":{"instrument":"us_ms_wqs","title":"Mississippi 11 Miss. Admin. Code Pt. 6, Ch. 2 Surface Water Quality Criteria for Intrastate, Interstate and Coastal Waters: Table 2 numeric criteria (freshwater and saltwater acute/chronic, human health), dissolved oxygen, pH, class mineral criteria and waterbody-specific criteria","issuer":"State of Mississippi, Commission on Environmental Quality (Department of Environmental Quality)","edition":"effective December 17, 2021, as US EPA posts it in effect for CWA purposes (cover March 18, 2022; EPA requested more information only on definition 27 and the Ephemeral Stream reference)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/ms-wqs.pdf","source_sha256":"272701c5d5a2f8b10cf9c40fc50f5eb52f07753965d4aad7d23d360d4da34264","fetched_at":"2026-10-10","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"11 Miss. Admin. Code Pt. 6, Ch. 2, Rule 2.2.G Table 2","page":18,"quote":null}},{"id":"049851d982eb8d3c","parameter":"Copper (dissolved)","value":"5.0 b,e","value_num":5,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-50-8","place":["US-MS"],"conditions":["receiving_water is freshwater","hardness 50 mg/l as CaCO3 (note b: the values in Table 2 are based on an in-stream hardness of 50 mg/l; other hardness takes the equations of EPA's Quality Criteria for Water)"],"cite":{"instrument":"us_ms_wqs","title":"Mississippi 11 Miss. Admin. Code Pt. 6, Ch. 2 Surface Water Quality Criteria for Intrastate, Interstate and Coastal Waters: Table 2 numeric criteria (freshwater and saltwater acute/chronic, human health), dissolved oxygen, pH, class mineral criteria and waterbody-specific criteria","issuer":"State of Mississippi, Commission on Environmental Quality (Department of Environmental Quality)","edition":"effective December 17, 2021, as US EPA posts it in effect for CWA purposes (cover March 18, 2022; EPA requested more information only on definition 27 and the Ephemeral Stream reference)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/ms-wqs.pdf","source_sha256":"272701c5d5a2f8b10cf9c40fc50f5eb52f07753965d4aad7d23d360d4da34264","fetched_at":"2026-10-10","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"11 Miss. Admin. Code Pt. 6, Ch. 2, Rule 2.2.G Table 2","page":18,"quote":null}},{"id":"737d6c290d5d6e05","parameter":"Copper (dissolved)","value":"4.8","value_num":4.8,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-50-8","place":["US-MS"],"conditions":["receiving_water is marine"],"cite":{"instrument":"us_ms_wqs","title":"Mississippi 11 Miss. Admin. Code Pt. 6, Ch. 2 Surface Water Quality Criteria for Intrastate, Interstate and Coastal Waters: Table 2 numeric criteria (freshwater and saltwater acute/chronic, human health), dissolved oxygen, pH, class mineral criteria and waterbody-specific criteria","issuer":"State of Mississippi, Commission on Environmental Quality (Department of Environmental Quality)","edition":"effective December 17, 2021, as US EPA posts it in effect for CWA purposes (cover March 18, 2022; EPA requested more information only on definition 27 and the Ephemeral Stream reference)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/ms-wqs.pdf","source_sha256":"272701c5d5a2f8b10cf9c40fc50f5eb52f07753965d4aad7d23d360d4da34264","fetched_at":"2026-10-10","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"11 Miss. Admin. Code Pt. 6, Ch. 2, Rule 2.2.G Table 2","page":18,"quote":null}},{"id":"1aace7d64be44629","parameter":"Copper (dissolved)","value":"3.1","value_num":3.1,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-50-8","place":["US-MS"],"conditions":["receiving_water is marine"],"cite":{"instrument":"us_ms_wqs","title":"Mississippi 11 Miss. Admin. Code Pt. 6, Ch. 2 Surface Water Quality Criteria for Intrastate, Interstate and Coastal Waters: Table 2 numeric criteria (freshwater and saltwater acute/chronic, human health), dissolved oxygen, pH, class mineral criteria and waterbody-specific criteria","issuer":"State of Mississippi, Commission on Environmental Quality (Department of Environmental Quality)","edition":"effective December 17, 2021, as US EPA posts it in effect for CWA purposes (cover March 18, 2022; EPA requested more information only on definition 27 and the Ephemeral Stream reference)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/ms-wqs.pdf","source_sha256":"272701c5d5a2f8b10cf9c40fc50f5eb52f07753965d4aad7d23d360d4da34264","fetched_at":"2026-10-10","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"11 Miss. Admin. Code Pt. 6, Ch. 2, Rule 2.2.G Table 2","page":18,"quote":null}},{"id":"02a04d414317b4bb","parameter":"Copper (dissolved)","value":"1000","value_num":1000,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-50-8","place":["US-MS"],"conditions":["receiving_water is freshwater","all waters except those classified Public Water Supply or within 50 stream miles upstream of a drinking water intake, which take the water & organisms criteria (Rule 2.2.F.4(a))"],"cite":{"instrument":"us_ms_wqs","title":"Mississippi 11 Miss. Admin. Code Pt. 6, Ch. 2 Surface Water Quality Criteria for Intrastate, Interstate and Coastal Waters: Table 2 numeric criteria (freshwater and saltwater acute/chronic, human health), dissolved oxygen, pH, class mineral criteria and waterbody-specific criteria","issuer":"State of Mississippi, Commission on Environmental Quality (Department of Environmental Quality)","edition":"effective December 17, 2021, as US EPA posts it in effect for CWA purposes (cover March 18, 2022; EPA requested more information only on definition 27 and the Ephemeral Stream reference)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/ms-wqs.pdf","source_sha256":"272701c5d5a2f8b10cf9c40fc50f5eb52f07753965d4aad7d23d360d4da34264","fetched_at":"2026-10-10","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"11 Miss. Admin. Code Pt. 6, Ch. 2, Rule 2.2.G Table 2","page":18,"quote":null}},{"id":"808577c43da00864","parameter":"Copper (dissolved)","value":"1000","value_num":1000,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-50-8","place":["US-MS"],"conditions":["receiving_water is marine","all waters except those classified Public Water Supply or within 50 stream miles upstream of a drinking water intake, which take the water & organisms criteria (Rule 2.2.F.4(a))"],"cite":{"instrument":"us_ms_wqs","title":"Mississippi 11 Miss. Admin. Code Pt. 6, Ch. 2 Surface Water Quality Criteria for Intrastate, Interstate and Coastal Waters: Table 2 numeric criteria (freshwater and saltwater acute/chronic, human health), dissolved oxygen, pH, class mineral criteria and waterbody-specific criteria","issuer":"State of Mississippi, Commission on Environmental Quality (Department of Environmental Quality)","edition":"effective December 17, 2021, as US EPA posts it in effect for CWA purposes (cover March 18, 2022; EPA requested more information only on definition 27 and the Ephemeral Stream reference)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/ms-wqs.pdf","source_sha256":"272701c5d5a2f8b10cf9c40fc50f5eb52f07753965d4aad7d23d360d4da34264","fetched_at":"2026-10-10","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"11 Miss. Admin. Code Pt. 6, Ch. 2, Rule 2.2.G Table 2","page":18,"quote":null}},{"id":"d44b7d6bcb19ebd8","parameter":"Copper (dissolved)","value":"1300","value_num":1300,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-50-8","place":["US-MS"],"conditions":["receiving_water is freshwater","waters classified Public Water Supply, or stream segments within 50 stream miles upstream of a drinking water intake (Rule 2.2.F.4(a))"],"cite":{"instrument":"us_ms_wqs","title":"Mississippi 11 Miss. Admin. Code Pt. 6, Ch. 2 Surface Water Quality Criteria for Intrastate, Interstate and Coastal Waters: Table 2 numeric criteria (freshwater and saltwater acute/chronic, human health), dissolved oxygen, pH, class mineral criteria and waterbody-specific criteria","issuer":"State of Mississippi, Commission on Environmental Quality (Department of Environmental Quality)","edition":"effective December 17, 2021, as US EPA posts it in effect for CWA purposes (cover March 18, 2022; EPA requested more information only on definition 27 and the Ephemeral Stream reference)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/ms-wqs.pdf","source_sha256":"272701c5d5a2f8b10cf9c40fc50f5eb52f07753965d4aad7d23d360d4da34264","fetched_at":"2026-10-10","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"11 Miss. Admin. Code Pt. 6, Ch. 2, Rule 2.2.G Table 2","page":18,"quote":null}},{"id":"256b028254b2bd82","parameter":"Cu","value":"4.5","value_num":4.5,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"16008a3c68209ada","parameter":"Cu","value":"2.7","value_num":2.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"22cbbea24b9da5bd","parameter":"Cu","value":"176","value_num":176,"unit":"mg/sq m-Operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may be applied in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"e21e1440752d2fc6","parameter":"Cu","value":"105","value_num":105,"unit":"mg/sq m-Operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may be applied in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"6ea14ea54f3404ca","parameter":"Cu","value":"4.5","value_num":4.5,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"40fa2c2f9b66b590","parameter":"Cu","value":"2.7","value_num":2.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"ed2ccb34fe0adb7b","parameter":"Cu","value":"176","value_num":176,"unit":"mg/sq m-Operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"f145e8fc6f26a53d","parameter":"Cu","value":"105","value_num":105,"unit":"mg/sq m-Operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"5c6869e8f7ce9806","parameter":"Cu","value":"4.5","value_num":4.5,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart D—Anodizing Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.44 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"6dd371e566f55874","parameter":"Cu","value":"2.7","value_num":2.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart D—Anodizing Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.44 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"6352db9ea086c87e","parameter":"Cu","value":"176","value_num":176,"unit":"mg/sq m-operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart D—Anodizing Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.44 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"119d18207921d6c5","parameter":"Cu","value":"105","value_num":105,"unit":"mg/sq m-operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart D—Anodizing Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.44 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"a04eb045e0431ca0","parameter":"Cu","value":"4.5","value_num":4.5,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart E—Coatings Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart E—Coatings Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.54 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"d5e0c3452c44b939","parameter":"Cu","value":"2.7","value_num":2.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart E—Coatings Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart E—Coatings Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.54 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"98efabf4c365118e","parameter":"Cu","value":"176","value_num":176,"unit":"mg/sq m-operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart E—Coatings Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart E—Coatings Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.54 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"84cb6bb97d7e1abe","parameter":"Cu","value":"105","value_num":105,"unit":"mg/sq m-operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart E—Coatings Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart E—Coatings Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.54 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"b46fca74c592bbf3","parameter":"Cu","value":"4.5","value_num":4.5,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart F—Chemical Etching and Milling Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal.) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart F—Chemicals Etching and Milling Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.64 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"0a4e32ffeb266cc6","parameter":"Cu","value":"2.7","value_num":2.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart F—Chemical Etching and Milling Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal.) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart F—Chemicals Etching and Milling Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.64 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"26dd6ba74da398d9","parameter":"Cu","value":"176","value_num":176,"unit":"mg/sq m-operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart F—Chemical Etching and Milling Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart F—Chemical Etching and Milling Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.64 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"80c73ca2b7b8171a","parameter":"Cu","value":"105","value_num":105,"unit":"mg/sq m-operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart F—Chemical Etching and Milling Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart F—Chemical Etching and Milling Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.64 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"22bdccfc00a3f2f4","parameter":"Cu","value":"4.5","value_num":4.5,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart G—Electroless Plating Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 l (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart G—Electroless Plating Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.74 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"13e953b81a11b746","parameter":"Cu","value":"2.7","value_num":2.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart G—Electroless Plating Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 l (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart G—Electroless Plating Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.74 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"302ae1967556fe7e","parameter":"Cu","value":"176","value_num":176,"unit":"mg/sq m-operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart G—Electroless Plating Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart G—Electroless Plating Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.74 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"6e74633e7b275fb3","parameter":"Cu","value":"105","value_num":105,"unit":"mg/sq m-operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart G—Electroless Plating Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart G—Electroless Plating Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.74 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"b57973496f4c755d","parameter":"Cu","value":"4.5","value_num":4.5,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart H—Printed Circuit Board Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart H—Printed Circuit Board Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.84 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"6ae65dbc345850e8","parameter":"Cu","value":"2.7","value_num":2.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart H—Printed Circuit Board Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart H—Printed Circuit Board Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.84 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"005c56a3cfc79e0b","parameter":"Cu","value":"401","value_num":401,"unit":"mg/sq m-operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart H—Printed Circuit Board Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart H—Printed Circuit Board Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.84 (PSES)","page":null,"quote":"Cu 401 241"}},{"id":"943febff3ebef50f","parameter":"Cu","value":"241","value_num":241,"unit":"mg/sq m-operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart H—Printed Circuit Board Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart H—Printed Circuit Board Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.84 (PSES)","page":null,"quote":"Cu 401 241"}},{"id":"036e4093649d6c33","parameter":"Total Copper","value":"3,380","value_num":3380,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment","existing sources (BAT)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.91 (BAT)","page":null,"quote":"Total Copper 3,380 1,450"}},{"id":"0470f7ffd030047d","parameter":"Total Copper","value":"3,380","value_num":3380,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment","new sources (NSPS)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.91 (NSPS)","page":null,"quote":"Total Copper 3,380 1,450"}},{"id":"10b18d87908d1d1f","parameter":"Total Copper","value":"1,450","value_num":1450,"unit":"µg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment","existing sources (BAT)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.91 (BAT)","page":null,"quote":"Total Copper 3,380 1,450"}},{"id":"92494cc88bb23b04","parameter":"Total Copper","value":"1,450","value_num":1450,"unit":"µg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment","new sources (NSPS)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.91 (NSPS)","page":null,"quote":"Total Copper 3,380 1,450"}},{"id":"561dd36d9452bbfe","parameter":"Total Copper","value":"3,380","value_num":3380,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment","existing sources (BAT)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.101 (BAT)","page":null,"quote":"Total Copper 3,380 1,450"}},{"id":"95ee697f99c92d7a","parameter":"Total Copper","value":"3,380","value_num":3380,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment","new sources (NSPS)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.101 (NSPS)","page":null,"quote":"Total Copper 3,380 1,450"}},{"id":"4760e5810eebca73","parameter":"Total Copper","value":"1,450","value_num":1450,"unit":"µg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment","existing sources (BAT)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.101 (BAT)","page":null,"quote":"Total Copper 3,380 1,450"}},{"id":"ca638e1a500d7203","parameter":"Total Copper","value":"1,450","value_num":1450,"unit":"µg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment","new sources (NSPS)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.101 (NSPS)","page":null,"quote":"Total Copper 3,380 1,450"}},{"id":"cb2caa88ac7bf5ac","parameter":"Copper (T)","value":"0.018","value_num":0.018,"unit":"Kg/kkg (or pounds per/1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart F—Chlor-alkali Subcategory (Chlorine and Sodium or Potassium Hydroxide Production)","existing sources (BPT)","table: Subpart F—Chlor-Alkali Diaphragm Cells"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.62 (BPT)","page":null,"quote":"Copper (T) 0.018 0.0070"}},{"id":"a65962785d0deea9","parameter":"Copper (T)","value":"0.0070","value_num":0.007,"unit":"Kg/kkg (or pounds per/1,000 lb) of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart F—Chlor-alkali Subcategory (Chlorine and Sodium or Potassium Hydroxide Production)","existing sources (BPT)","table: Subpart F—Chlor-Alkali Diaphragm Cells"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.62 (BPT)","page":null,"quote":"Copper (T) 0.018 0.0070"}},{"id":"38449ffd7cf646c7","parameter":"Copper (T)","value":"0.012","value_num":0.012,"unit":"Kg/kkg (or pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart F—Chlor-alkali Subcategory (Chlorine and Sodium or Potassium Hydroxide Production)","existing sources (BAT)","table: Subpart F—Chlor-Alkali-Diaphragm Cells"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.63 (BAT)","page":null,"quote":"Copper (T) 0.012 0.0049"}},{"id":"78b264935168569c","parameter":"Copper (T)","value":"0.0049","value_num":0.0049,"unit":"Kg/kkg (or pounds per 1,000 lb) of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart F—Chlor-alkali Subcategory (Chlorine and Sodium or Potassium Hydroxide Production)","existing sources (BAT)","table: Subpart F—Chlor-Alkali-Diaphragm Cells"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.63 (BAT)","page":null,"quote":"Copper (T) 0.012 0.0049"}},{"id":"47a7d51859b30e2a","parameter":"Copper (T)","value":"2.1","value_num":2.1,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart F—Chlor-alkali Subcategory (Chlorine and Sodium or Potassium Hydroxide Production)","existing sources (PSES)","table: Subpart F—Chlor-Alkali-Diaphragm Cells"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.64 (PSES)","page":null,"quote":"Copper (T) 2.1 0.80"}},{"id":"eb1d3e19bbda406b","parameter":"Copper (T)","value":"0.80","value_num":0.8,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart F—Chlor-alkali Subcategory (Chlorine and Sodium or Potassium Hydroxide Production)","existing sources (PSES)","table: Subpart F—Chlor-Alkali-Diaphragm Cells"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.64 (PSES)","page":null,"quote":"Copper (T) 2.1 0.80"}},{"id":"90eec067ffd67c55","parameter":"Copper (T)","value":"0.0030","value_num":0.003,"unit":"Kg/kkg (or pounds per/1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart AJ—Copper Salts Production Subcategory","existing sources (BPT)","table: Subpart AJ—Copper Sulfate, Copper Chloride, Copper Iodide, Copper Nitrate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.362 (BPT)","page":null,"quote":"Copper (T) 0.0030 0.0010"}}],"next":[{"tool":"check_values","says":"Has your user measured this? check_values sets each of their results beside every row held here, with a verdict and the row's cite.","arguments":{"place":"US-MS"},"needs":{"rows":"Your user's measured results, as their table prints them: [{parameter: \"copper\", value, unit}, ...], any other parameters too."},"post":"/api/v1/check"},{"tool":"read_certificate","says":"Has your user a laboratory certificate? read_certificate reads every row it prints, each with its page, and checks them against these limits.","arguments":{"place":"US-MS"},"needs":{"content_base64":"The laboratory's certificate (PDF) or its XLSX, XLS or CSV export, as base64; or file_url, a public https address of it."},"post":"/api/v1/certificate"}]}