{"query":{"parameter":"copper","place":"US-LA","medium":null,"statistic":null,"kind":null},"searched":{"places":["US-LA","US"],"parameter_keys":["cas:7440-50-8","name:arsenic, cadmium (h), copper (h), lead (h), mercury, zinc","name:arsenic, cadmium (h), copper (h), lead (h), zinc","name:cadmium (h), copper (h), mercury, lead (h), zinc","cas:68512-13-0","cas:544-92-3","name:copper - total","name:copper, total","name:copper, total recoverable","name:total copper","name:cuivre extractible"],"names_matched":[["copper","cas:7440-50-8"],["arsenic cadmium h copper h lead h mercury zinc","name:arsenic, cadmium (h), copper (h), lead (h), mercury, zinc"],["arsenic cadmium h copper h lead h mercury zinc h","name:arsenic, cadmium (h), copper (h), lead (h), mercury, zinc"],["arsenic cadmium h copper h lead h zinc","name:arsenic, cadmium (h), copper (h), lead (h), zinc"],["arsenic cadmium h copper h lead h zinc h","name:arsenic, cadmium (h), copper (h), lead (h), zinc"],["cadmium h copper h mercury lead h zinc","name:cadmium (h), copper (h), mercury, lead (h), zinc"],["cadmium h copper h mercury lead h zinc h","name:cadmium (h), copper (h), mercury, lead (h), zinc"],["copper 29h 31h phthalocyaninato 2 kappa n29 kappa n30 kappa n31 kappa n32 brominated chlorinated","cas:68512-13-0"],["copper cyanide","cas:544-92-3"],["copper cyanide cu cn","cas:544-92-3"],["copper cyanide cucn","cas:544-92-3"],["copper i cyanide","cas:544-92-3"],["copper total","name:copper - total"],["copper total","name:copper, total"],["copper total recoverable","name:copper, total recoverable"],["total copper","name:total copper"],["total copper freshwater","name:total copper"],["total copper marine","name:total copper"],["cuivre extractible","name:cuivre extractible","cuivre"]],"match":"exact+contains","order":"The place's own instruments first, then each place above it, each in its register's order"},"total":2395,"offset":0,"returned":50,"next_offset":50,"rows":[{"id":"944fb46f8d173851","parameter":"Copper (and compounds)[1]","value":"25.0","value_num":25,"unit":"lb/yr","direction":"max","kind":"threshold","medium":"air_emission","level":"regional","parameter_key":"cas:7440-50-8","place":["US-LA"],"conditions":["the source is a major source of toxic air pollutants (5103)"],"cite":{"instrument":"us_la_lac33_iii_5112","title":"LAC 33:III.5112 — Toxic air pollutants: minimum emission rates (Table 51.1) and ambient air standards (Table 51.2)","issuer":null,"edition":"LII transcription of LAC 33:III.5112 (fetched 2026-09-25)","source_url":"https://www.law.cornell.edu/regulations/louisiana/La-Admin-Code-tit-33-SS-III-5112","source_sha256":"ad168892d6da7f3e8eda05d066b3cf2a0018d9fefcd81676abc7ca5110cca6dc","fetched_at":"2026-09-25","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"Table 51.1 Class II","page":null,"quote":"Copper (and compounds)[1] 7440-50-8  25.0"}},{"id":"caba92cb6528cf34","parameter":"Copper (and compounds) [1]","value":"23.80","value_num":23.8,"unit":"µg/m³","statistic":"eight_hour_avg","direction":"max","kind":"limit","medium":"ambient_air","level":"regional","parameter_key":"cas:7440-50-8","place":["US-LA"],"conditions":["a major source at or above the minimum emission rate demonstrates it (5109.B)"],"cite":{"instrument":"us_la_lac33_iii_5112","title":"LAC 33:III.5112 — Toxic air pollutants: minimum emission rates (Table 51.1) and ambient air standards (Table 51.2)","issuer":null,"edition":"LII transcription of LAC 33:III.5112 (fetched 2026-09-25)","source_url":"https://www.law.cornell.edu/regulations/louisiana/La-Admin-Code-tit-33-SS-III-5112","source_sha256":"ad168892d6da7f3e8eda05d066b3cf2a0018d9fefcd81676abc7ca5110cca6dc","fetched_at":"2026-09-25","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"Table 51.2 Class II","page":null,"quote":"Copper (and compounds) [1] 7440-50-8 II 23.80"}},{"id":"71da32fd3ad06eea","parameter":"Arsenic, Cadmium (H), Copper (H), Lead (H), Mercury, Zinc (H)","value":"Report Values","kind":"benchmark","medium":"water_discharge","level":"regional","stream":"stormwater","parameter_key":"name:arsenic, cadmium (h), copper (h), lead (h), mercury, zinc","place":["US-LA"],"conditions":["coverage is LAR050000","stream is stormwater","sector is G","G3: Discharges from Molybdenum Mining Facilities"],"cite":{"instrument":"us_la_lar050000","title":"LPDES Multi-Sector General Permit LAR050000 — storm water discharges associated with industrial activity (AI# 86163)","issuer":"Louisiana Department of Environmental Quality (LDEQ)","edition":"October 2021 (modified pages)","source_url":"https://www.deq.louisiana.gov/ (LDEQ general permit LAR050000, October 2021, held in the corpus)","source_sha256":"d8dcaa388df45cc4e55bc3b04b2e77808a244d52dba7faeac287f4d24bde3251","fetched_at":"2026-09-23","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"Table 3","page":37,"quote":null}},{"id":"4b5f7c6e4acf1ae6","parameter":"Arsenic, Cadmium (H), Copper (H), Lead (H), Zinc (H)","value":"Report Values","kind":"benchmark","medium":"water_discharge","level":"regional","stream":"stormwater","parameter_key":"name:arsenic, cadmium (h), copper (h), lead (h), zinc","place":["US-LA"],"conditions":["coverage is LAR050000","stream is stormwater","sector is G","G3: Discharges from Tungsten Ore, Nickel Ore, and Vanadium Ore Mining Facilities"],"cite":{"instrument":"us_la_lar050000","title":"LPDES Multi-Sector General Permit LAR050000 — storm water discharges associated with industrial activity (AI# 86163)","issuer":"Louisiana Department of Environmental Quality (LDEQ)","edition":"October 2021 (modified pages)","source_url":"https://www.deq.louisiana.gov/ (LDEQ general permit LAR050000, October 2021, held in the corpus)","source_sha256":"d8dcaa388df45cc4e55bc3b04b2e77808a244d52dba7faeac287f4d24bde3251","fetched_at":"2026-09-23","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"Table 3","page":37,"quote":null}},{"id":"9b66d7aa0b84fa2e","parameter":"Cadmium (H), Copper (H), Mercury, Lead (H), Zinc (H)","value":"Report Values","kind":"benchmark","medium":"water_discharge","level":"regional","stream":"stormwater","parameter_key":"name:cadmium (h), copper (h), mercury, lead (h), zinc","place":["US-LA"],"conditions":["coverage is LAR050000","stream is stormwater","sector is G","G3: Discharges from Platinum Ore Mining Facilities"],"cite":{"instrument":"us_la_lar050000","title":"LPDES Multi-Sector General Permit LAR050000 — storm water discharges associated with industrial activity (AI# 86163)","issuer":"Louisiana Department of Environmental Quality (LDEQ)","edition":"October 2021 (modified pages)","source_url":"https://www.deq.louisiana.gov/ (LDEQ general permit LAR050000, October 2021, held in the corpus)","source_sha256":"d8dcaa388df45cc4e55bc3b04b2e77808a244d52dba7faeac287f4d24bde3251","fetched_at":"2026-09-23","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"Table 3","page":37,"quote":null}},{"id":"da66db0bd8cd1978","parameter":"Total Copper (freshwater)","value":"Hardness Dependent","kind":"benchmark","medium":"water_discharge","level":"regional","stream":"stormwater","parameter_key":"name:total copper","place":["US-LA"],"conditions":["coverage is LAR050000","stream is stormwater","sector is A","sic in 2491","receiving_water is freshwater"],"cite":{"instrument":"us_la_lar050000","title":"LPDES Multi-Sector General Permit LAR050000 — storm water discharges associated with industrial activity (AI# 86163)","issuer":"Louisiana Department of Environmental Quality (LDEQ)","edition":"October 2021 (modified pages)","source_url":"https://www.deq.louisiana.gov/ (LDEQ general permit LAR050000, October 2021, held in the corpus)","source_sha256":"d8dcaa388df45cc4e55bc3b04b2e77808a244d52dba7faeac287f4d24bde3251","fetched_at":"2026-09-23","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"Table 3","page":33,"quote":null}},{"id":"a37df6210a5a2796","parameter":"Total Copper (marine)","value":"0.0048 mg/L","value_num":0.0048,"unit":"mg/L","direction":"max","kind":"benchmark","medium":"water_discharge","level":"regional","stream":"stormwater","parameter_key":"name:total copper","place":["US-LA"],"conditions":["coverage is LAR050000","stream is stormwater","sector is A","sic in 2491","receiving_water is marine"],"cite":{"instrument":"us_la_lar050000","title":"LPDES Multi-Sector General Permit LAR050000 — storm water discharges associated with industrial activity (AI# 86163)","issuer":"Louisiana Department of Environmental Quality (LDEQ)","edition":"October 2021 (modified pages)","source_url":"https://www.deq.louisiana.gov/ (LDEQ general permit LAR050000, October 2021, held in the corpus)","source_sha256":"d8dcaa388df45cc4e55bc3b04b2e77808a244d52dba7faeac287f4d24bde3251","fetched_at":"2026-09-23","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"Table 3","page":33,"quote":null}},{"id":"22d80d38aead5290","parameter":"Total Copper (freshwater)","value":"Hardness Dependent","kind":"benchmark","medium":"water_discharge","level":"regional","stream":"stormwater","parameter_key":"name:total copper","place":["US-LA"],"conditions":["coverage is LAR050000","stream is stormwater","sector is F","sic in ['3321', '3325']","receiving_water is freshwater"],"cite":{"instrument":"us_la_lar050000","title":"LPDES Multi-Sector General Permit LAR050000 — storm water discharges associated with industrial activity (AI# 86163)","issuer":"Louisiana Department of Environmental Quality (LDEQ)","edition":"October 2021 (modified pages)","source_url":"https://www.deq.louisiana.gov/ (LDEQ general permit LAR050000, October 2021, held in the corpus)","source_sha256":"d8dcaa388df45cc4e55bc3b04b2e77808a244d52dba7faeac287f4d24bde3251","fetched_at":"2026-09-23","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"Table 3","page":35,"quote":null}},{"id":"c4e30eb756f7cb59","parameter":"Total Copper (marine)","value":"0.0048 mg/L","value_num":0.0048,"unit":"mg/L","direction":"max","kind":"benchmark","medium":"water_discharge","level":"regional","stream":"stormwater","parameter_key":"name:total copper","place":["US-LA"],"conditions":["coverage is LAR050000","stream is stormwater","sector is F","sic in ['3321', '3325']","receiving_water is marine"],"cite":{"instrument":"us_la_lar050000","title":"LPDES Multi-Sector General Permit LAR050000 — storm water discharges associated with industrial activity (AI# 86163)","issuer":"Louisiana Department of Environmental Quality (LDEQ)","edition":"October 2021 (modified pages)","source_url":"https://www.deq.louisiana.gov/ (LDEQ general permit LAR050000, October 2021, held in the corpus)","source_sha256":"d8dcaa388df45cc4e55bc3b04b2e77808a244d52dba7faeac287f4d24bde3251","fetched_at":"2026-09-23","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"Table 3","page":35,"quote":null}},{"id":"632115d40b46c42c","parameter":"Total Copper (freshwater)","value":"Hardness Dependent","kind":"benchmark","medium":"water_discharge","level":"regional","stream":"stormwater","parameter_key":"name:total copper","place":["US-LA"],"conditions":["coverage is LAR050000","stream is stormwater","sector is F","sic in ['3351', '3357']","receiving_water is freshwater"],"cite":{"instrument":"us_la_lar050000","title":"LPDES Multi-Sector General Permit LAR050000 — storm water discharges associated with industrial activity (AI# 86163)","issuer":"Louisiana Department of Environmental Quality (LDEQ)","edition":"October 2021 (modified pages)","source_url":"https://www.deq.louisiana.gov/ (LDEQ general permit LAR050000, October 2021, held in the corpus)","source_sha256":"d8dcaa388df45cc4e55bc3b04b2e77808a244d52dba7faeac287f4d24bde3251","fetched_at":"2026-09-23","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"Table 3","page":35,"quote":null}},{"id":"9c50af0ba527f9dd","parameter":"Total Copper (marine)","value":"0.0048 mg/L","value_num":0.0048,"unit":"mg/L","direction":"max","kind":"benchmark","medium":"water_discharge","level":"regional","stream":"stormwater","parameter_key":"name:total copper","place":["US-LA"],"conditions":["coverage is LAR050000","stream is stormwater","sector is F","sic in ['3351', '3357']","receiving_water is marine"],"cite":{"instrument":"us_la_lar050000","title":"LPDES Multi-Sector General Permit LAR050000 — storm water discharges associated with industrial activity (AI# 86163)","issuer":"Louisiana Department of Environmental Quality (LDEQ)","edition":"October 2021 (modified pages)","source_url":"https://www.deq.louisiana.gov/ (LDEQ general permit LAR050000, October 2021, held in the corpus)","source_sha256":"d8dcaa388df45cc4e55bc3b04b2e77808a244d52dba7faeac287f4d24bde3251","fetched_at":"2026-09-23","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"Table 3","page":35,"quote":null}},{"id":"829ae817eaa07ed6","parameter":"Total Copper (freshwater)","value":"Hardness Dependent","kind":"benchmark","medium":"water_discharge","level":"regional","stream":"stormwater","parameter_key":"name:total copper","place":["US-LA"],"conditions":["coverage is LAR050000","stream is stormwater","sector is F","sic in ['3363', '3369']","receiving_water is freshwater"],"cite":{"instrument":"us_la_lar050000","title":"LPDES Multi-Sector General Permit LAR050000 — storm water discharges associated with industrial activity (AI# 86163)","issuer":"Louisiana Department of Environmental Quality (LDEQ)","edition":"October 2021 (modified pages)","source_url":"https://www.deq.louisiana.gov/ (LDEQ general permit LAR050000, October 2021, held in the corpus)","source_sha256":"d8dcaa388df45cc4e55bc3b04b2e77808a244d52dba7faeac287f4d24bde3251","fetched_at":"2026-09-23","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"Table 3","page":35,"quote":null}},{"id":"5f5b5b5e76440f50","parameter":"Total Copper (marine)","value":"0.0048 mg/L","value_num":0.0048,"unit":"mg/L","direction":"max","kind":"benchmark","medium":"water_discharge","level":"regional","stream":"stormwater","parameter_key":"name:total copper","place":["US-LA"],"conditions":["coverage is LAR050000","stream is stormwater","sector is F","sic in ['3363', '3369']","receiving_water is marine"],"cite":{"instrument":"us_la_lar050000","title":"LPDES Multi-Sector General Permit LAR050000 — storm water discharges associated with industrial activity (AI# 86163)","issuer":"Louisiana Department of Environmental Quality (LDEQ)","edition":"October 2021 (modified pages)","source_url":"https://www.deq.louisiana.gov/ (LDEQ general permit LAR050000, October 2021, held in the corpus)","source_sha256":"d8dcaa388df45cc4e55bc3b04b2e77808a244d52dba7faeac287f4d24bde3251","fetched_at":"2026-09-23","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"Table 3","page":35,"quote":null}},{"id":"e96eee5885013cbd","parameter":"Total Copper (freshwater)","value":"Hardness Dependent","kind":"benchmark","medium":"water_discharge","level":"regional","stream":"stormwater","parameter_key":"name:total copper","place":["US-LA"],"conditions":["coverage is LAR050000","stream is stormwater","sector is G","sic in 1011, 1021, 1031, 1041, 1044, 1061, 1081, 1094, 1099","receiving_water is freshwater"],"cite":{"instrument":"us_la_lar050000","title":"LPDES Multi-Sector General Permit LAR050000 — storm water discharges associated with industrial activity (AI# 86163)","issuer":"Louisiana Department of Environmental Quality (LDEQ)","edition":"October 2021 (modified pages)","source_url":"https://www.deq.louisiana.gov/ (LDEQ general permit LAR050000, October 2021, held in the corpus)","source_sha256":"d8dcaa388df45cc4e55bc3b04b2e77808a244d52dba7faeac287f4d24bde3251","fetched_at":"2026-09-23","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"Table 3","page":36,"quote":null}},{"id":"1667d0c36813850b","parameter":"Total Copper (marine)","value":"0.0048 mg/L","value_num":0.0048,"unit":"mg/L","direction":"max","kind":"benchmark","medium":"water_discharge","level":"regional","stream":"stormwater","parameter_key":"name:total copper","place":["US-LA"],"conditions":["coverage is LAR050000","stream is stormwater","sector is G","sic in 1011, 1021, 1031, 1041, 1044, 1061, 1081, 1094, 1099","receiving_water is marine"],"cite":{"instrument":"us_la_lar050000","title":"LPDES Multi-Sector General Permit LAR050000 — storm water discharges associated with industrial activity (AI# 86163)","issuer":"Louisiana Department of Environmental Quality (LDEQ)","edition":"October 2021 (modified pages)","source_url":"https://www.deq.louisiana.gov/ (LDEQ general permit LAR050000, October 2021, held in the corpus)","source_sha256":"d8dcaa388df45cc4e55bc3b04b2e77808a244d52dba7faeac287f4d24bde3251","fetched_at":"2026-09-23","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"Table 3","page":36,"quote":null}},{"id":"ed87eee50684ee90","parameter":"Total Copper (freshwater)","value":"Hardness Dependent","kind":"benchmark","medium":"water_discharge","level":"regional","stream":"stormwater","parameter_key":"name:total copper","place":["US-LA"],"conditions":["coverage is LAR050000","stream is stormwater","sector is N","sic in 5093","receiving_water is freshwater"],"cite":{"instrument":"us_la_lar050000","title":"LPDES Multi-Sector General Permit LAR050000 — storm water discharges associated with industrial activity (AI# 86163)","issuer":"Louisiana Department of Environmental Quality (LDEQ)","edition":"October 2021 (modified pages)","source_url":"https://www.deq.louisiana.gov/ (LDEQ general permit LAR050000, October 2021, held in the corpus)","source_sha256":"d8dcaa388df45cc4e55bc3b04b2e77808a244d52dba7faeac287f4d24bde3251","fetched_at":"2026-09-23","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"Table 3","page":43,"quote":null}},{"id":"67b106c6efd2f76b","parameter":"Total Copper (marine)","value":"0.0048 mg/L","value_num":0.0048,"unit":"mg/L","direction":"max","kind":"benchmark","medium":"water_discharge","level":"regional","stream":"stormwater","parameter_key":"name:total copper","place":["US-LA"],"conditions":["coverage is LAR050000","stream is stormwater","sector is N","sic in 5093","receiving_water is marine"],"cite":{"instrument":"us_la_lar050000","title":"LPDES Multi-Sector General Permit LAR050000 — storm water discharges associated with industrial activity (AI# 86163)","issuer":"Louisiana Department of Environmental Quality (LDEQ)","edition":"October 2021 (modified pages)","source_url":"https://www.deq.louisiana.gov/ (LDEQ general permit LAR050000, October 2021, held in the corpus)","source_sha256":"d8dcaa388df45cc4e55bc3b04b2e77808a244d52dba7faeac287f4d24bde3251","fetched_at":"2026-09-23","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"Table 3","page":43,"quote":null}},{"id":"d96d437d02cc8b36","parameter":"Total Copper (freshwater)","value":"Hardness Dependent","kind":"benchmark","medium":"water_discharge","level":"regional","stream":"stormwater","parameter_key":"name:total copper","place":["US-LA"],"conditions":["coverage is LAR050000","stream is stormwater","sector is R","sic in 3731, 3732","receiving_water is freshwater"],"cite":{"instrument":"us_la_lar050000","title":"LPDES Multi-Sector General Permit LAR050000 — storm water discharges associated with industrial activity (AI# 86163)","issuer":"Louisiana Department of Environmental Quality (LDEQ)","edition":"October 2021 (modified pages)","source_url":"https://www.deq.louisiana.gov/ (LDEQ general permit LAR050000, October 2021, held in the corpus)","source_sha256":"d8dcaa388df45cc4e55bc3b04b2e77808a244d52dba7faeac287f4d24bde3251","fetched_at":"2026-09-23","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"Table 3","page":44,"quote":null}},{"id":"f6ccdf05114b26ac","parameter":"Total Copper (marine)","value":"0.0048 mg/L","value_num":0.0048,"unit":"mg/L","direction":"max","kind":"benchmark","medium":"water_discharge","level":"regional","stream":"stormwater","parameter_key":"name:total copper","place":["US-LA"],"conditions":["coverage is LAR050000","stream is stormwater","sector is R","sic in 3731, 3732","receiving_water is marine"],"cite":{"instrument":"us_la_lar050000","title":"LPDES Multi-Sector General Permit LAR050000 — storm water discharges associated with industrial activity (AI# 86163)","issuer":"Louisiana Department of Environmental Quality (LDEQ)","edition":"October 2021 (modified pages)","source_url":"https://www.deq.louisiana.gov/ (LDEQ general permit LAR050000, October 2021, held in the corpus)","source_sha256":"d8dcaa388df45cc4e55bc3b04b2e77808a244d52dba7faeac287f4d24bde3251","fetched_at":"2026-09-23","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"Table 3","page":44,"quote":null}},{"id":"256b028254b2bd82","parameter":"Cu","value":"4.5","value_num":4.5,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"16008a3c68209ada","parameter":"Cu","value":"2.7","value_num":2.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"22cbbea24b9da5bd","parameter":"Cu","value":"176","value_num":176,"unit":"mg/sq m-Operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may be applied in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"e21e1440752d2fc6","parameter":"Cu","value":"105","value_num":105,"unit":"mg/sq m-Operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may be applied in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"6ea14ea54f3404ca","parameter":"Cu","value":"4.5","value_num":4.5,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"40fa2c2f9b66b590","parameter":"Cu","value":"2.7","value_num":2.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"ed2ccb34fe0adb7b","parameter":"Cu","value":"176","value_num":176,"unit":"mg/sq m-Operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"f145e8fc6f26a53d","parameter":"Cu","value":"105","value_num":105,"unit":"mg/sq m-Operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"5c6869e8f7ce9806","parameter":"Cu","value":"4.5","value_num":4.5,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart D—Anodizing Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.44 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"6dd371e566f55874","parameter":"Cu","value":"2.7","value_num":2.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart D—Anodizing Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.44 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"6352db9ea086c87e","parameter":"Cu","value":"176","value_num":176,"unit":"mg/sq m-operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart D—Anodizing Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.44 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"119d18207921d6c5","parameter":"Cu","value":"105","value_num":105,"unit":"mg/sq m-operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart D—Anodizing Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.44 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"a04eb045e0431ca0","parameter":"Cu","value":"4.5","value_num":4.5,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart E—Coatings Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart E—Coatings Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.54 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"d5e0c3452c44b939","parameter":"Cu","value":"2.7","value_num":2.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart E—Coatings Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart E—Coatings Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.54 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"98efabf4c365118e","parameter":"Cu","value":"176","value_num":176,"unit":"mg/sq m-operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart E—Coatings Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart E—Coatings Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.54 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"84cb6bb97d7e1abe","parameter":"Cu","value":"105","value_num":105,"unit":"mg/sq m-operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart E—Coatings Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart E—Coatings Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.54 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"b46fca74c592bbf3","parameter":"Cu","value":"4.5","value_num":4.5,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart F—Chemical Etching and Milling Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal.) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart F—Chemicals Etching and Milling Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.64 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"0a4e32ffeb266cc6","parameter":"Cu","value":"2.7","value_num":2.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart F—Chemical Etching and Milling Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal.) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart F—Chemicals Etching and Milling Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.64 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"26dd6ba74da398d9","parameter":"Cu","value":"176","value_num":176,"unit":"mg/sq m-operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart F—Chemical Etching and Milling Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart F—Chemical Etching and Milling Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.64 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"80c73ca2b7b8171a","parameter":"Cu","value":"105","value_num":105,"unit":"mg/sq m-operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart F—Chemical Etching and Milling Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart F—Chemical Etching and Milling Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.64 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"22bdccfc00a3f2f4","parameter":"Cu","value":"4.5","value_num":4.5,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart G—Electroless Plating Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 l (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart G—Electroless Plating Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.74 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"13e953b81a11b746","parameter":"Cu","value":"2.7","value_num":2.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart G—Electroless Plating Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 l (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart G—Electroless Plating Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.74 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"302ae1967556fe7e","parameter":"Cu","value":"176","value_num":176,"unit":"mg/sq m-operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart G—Electroless Plating Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart G—Electroless Plating Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.74 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"6e74633e7b275fb3","parameter":"Cu","value":"105","value_num":105,"unit":"mg/sq m-operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart G—Electroless Plating Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart G—Electroless Plating Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.74 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"b57973496f4c755d","parameter":"Cu","value":"4.5","value_num":4.5,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart H—Printed Circuit Board Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart H—Printed Circuit Board Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.84 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"6ae65dbc345850e8","parameter":"Cu","value":"2.7","value_num":2.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart H—Printed Circuit Board Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart H—Printed Circuit Board Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.84 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"005c56a3cfc79e0b","parameter":"Cu","value":"401","value_num":401,"unit":"mg/sq m-operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart H—Printed Circuit Board Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart H—Printed Circuit Board Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.84 (PSES)","page":null,"quote":"Cu 401 241"}},{"id":"943febff3ebef50f","parameter":"Cu","value":"241","value_num":241,"unit":"mg/sq m-operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart H—Printed Circuit Board Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart H—Printed Circuit Board Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.84 (PSES)","page":null,"quote":"Cu 401 241"}},{"id":"036e4093649d6c33","parameter":"Total Copper","value":"3,380","value_num":3380,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment","existing sources (BAT)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.91 (BAT)","page":null,"quote":"Total Copper 3,380 1,450"}},{"id":"0470f7ffd030047d","parameter":"Total Copper","value":"3,380","value_num":3380,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment","new sources (NSPS)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.91 (NSPS)","page":null,"quote":"Total Copper 3,380 1,450"}},{"id":"10b18d87908d1d1f","parameter":"Total Copper","value":"1,450","value_num":1450,"unit":"µg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment","existing sources (BAT)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.91 (BAT)","page":null,"quote":"Total Copper 3,380 1,450"}}],"next":[{"tool":"check_values","says":"Has your user measured this? check_values sets each of their results beside every row held here, with a verdict and the row's cite.","arguments":{"place":"US-LA"},"needs":{"rows":"Your user's measured results, as their table prints them: [{parameter: \"copper\", value, unit}, ...], any other parameters too."},"post":"/api/v1/check"},{"tool":"read_certificate","says":"Has your user a laboratory certificate? read_certificate reads every row it prints, each with its page, and checks them against these limits.","arguments":{"place":"US-LA"},"needs":{"content_base64":"The laboratory's certificate (PDF) or its XLSX, XLS or CSV export, as base64; or file_url, a public https address of it."},"post":"/api/v1/certificate"}]}