{"query":{"parameter":"copper","place":"US-FL","medium":null,"statistic":null,"kind":null},"searched":{"places":["US-FL","US"],"parameter_keys":["cas:7440-50-8","name:arsenic, cadmium (h), copper (h), lead (h), mercury, zinc","name:arsenic, cadmium (h), copper (h), lead (h), zinc","name:cadmium (h), copper (h), mercury, lead (h), zinc","cas:68512-13-0","cas:544-92-3","name:copper - total","name:copper, total","name:copper, total recoverable","name:total copper","name:cuivre extractible"],"names_matched":[["copper","cas:7440-50-8"],["arsenic cadmium h copper h lead h mercury zinc","name:arsenic, cadmium (h), copper (h), lead (h), mercury, zinc"],["arsenic cadmium h copper h lead h mercury zinc h","name:arsenic, cadmium (h), copper (h), lead (h), mercury, zinc"],["arsenic cadmium h copper h lead h zinc","name:arsenic, cadmium (h), copper (h), lead (h), zinc"],["arsenic cadmium h copper h lead h zinc h","name:arsenic, cadmium (h), copper (h), lead (h), zinc"],["cadmium h copper h mercury lead h zinc","name:cadmium (h), copper (h), mercury, lead (h), zinc"],["cadmium h copper h mercury lead h zinc h","name:cadmium (h), copper (h), mercury, lead (h), zinc"],["copper 29h 31h phthalocyaninato 2 kappa n29 kappa n30 kappa n31 kappa n32 brominated chlorinated","cas:68512-13-0"],["copper cyanide","cas:544-92-3"],["copper cyanide cu cn","cas:544-92-3"],["copper cyanide cucn","cas:544-92-3"],["copper i cyanide","cas:544-92-3"],["copper total","name:copper - total"],["copper total","name:copper, total"],["copper total recoverable","name:copper, total recoverable"],["total copper","name:total copper"],["total copper freshwater","name:total copper"],["total copper marine","name:total copper"],["cuivre extractible","name:cuivre extractible","cuivre"]],"match":"exact+contains","order":"The place's own instruments first, then each place above it, each in its register's order"},"total":2388,"offset":0,"returned":50,"next_offset":50,"rows":[{"id":"9e72ff9627d92568","parameter":"Copper","value":"1000","value_num":1000,"unit":"µg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:7440-50-8","place":["US-FL"],"conditions":["groundwater (Table I, Groundwater Criteria column)","Note: If more than one contaminant is present at a site, CTLs are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Figure 10 of the February 2005 'Final Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.' However, GCTLs for primary and secondary standards shall not be modified."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","section":"Ch. 62-777 F.A.C. Table I, Groundwater and Surface Water Cleanup Target Levels, Groundwater Criteria (DEP spreadsheet, sheet TTable1, row 139)","page":null,"quote":"row 139: Copper | 1000 |  | 2.9 | 10000 | -Gastrointestinal  | 7440-50-8 |  | Secondary Standard | 62-302 | 62-302 |  | Organoleptic & GI irritant | f, g | g"}},{"id":"a54a9ef955c13ef9","parameter":"Copper","value":"2.9","value_num":2.9,"unit":"µg/L","direction":"max","kind":"threshold","medium":"surface_water","level":"regional","parameter_key":"cas:7440-50-8","place":["US-FL"],"conditions":["receiving_water is marine","marine surface water (Table I, Marine Surface Water Criteria column)","Note: If more than one contaminant is present at a site, CTLs are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Figure 10 of the February 2005 'Final Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.' However, GCTLs for primary and secondary standards shall not be modified."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","section":"Ch. 62-777 F.A.C. Table I, Groundwater and Surface Water Cleanup Target Levels, Marine Surface Water Criteria (DEP spreadsheet, sheet TTable1, row 139)","page":null,"quote":"row 139: Copper | 1000 |  | 2.9 | 10000 | -Gastrointestinal  | 7440-50-8 |  | Secondary Standard | 62-302 | 62-302 |  | Organoleptic & GI irritant | f, g | g"}},{"id":"b18730131a5ff450","parameter":"Copper","value":"10000","value_num":10000,"unit":"µg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:7440-50-8","place":["US-FL"],"conditions":["groundwater of low yield/poor quality (Table I, Groundwater of Low Yield/Poor Quality Criteria column)","Note: If more than one contaminant is present at a site, CTLs are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Figure 10 of the February 2005 'Final Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.' However, GCTLs for primary and secondary standards shall not be modified."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","section":"Ch. 62-777 F.A.C. Table I, Groundwater and Surface Water Cleanup Target Levels, Groundwater of Low Yield/Poor Quality Criteria (DEP spreadsheet, sheet TTable1, row 139)","page":null,"quote":"row 139: Copper | 1000 |  | 2.9 | 10000 | -Gastrointestinal  | 7440-50-8 |  | Secondary Standard | 62-302 | 62-302 |  | Organoleptic & GI irritant | f, g | g"}},{"id":"ef71c96b284d377b","parameter":"Copper","value":"150","value_num":150,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7440-50-8","place":["US-FL"],"conditions":["residential direct exposure (Table II, Direct Exposure - Residential column)","** Direct exposure value based on acute toxicity considerations. This criterion is applicable in scenarios where children might be exposed to soils (e.g. residences, schools, playgrounds)","Note: If more than one contaminant is present at a site, the direct exposure values are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Appendix D 'Draft Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.', dated February 2005."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","section":"Ch. 62-777 F.A.C. Table II, Soil Cleanup Target Levels, Direct Exposure - Residential (DEP spreadsheet, sheet TTable2, row 130)","page":null,"quote":"row 130: Copper | -Gastrointestinal  | 7440-50-8 | 150** | 89000 | *** | NA | *** | ***"}},{"id":"a8d63b7b84b41725","parameter":"Copper","value":"89000","value_num":89000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7440-50-8","place":["US-FL"],"conditions":["industrial direct exposure (Table II, Direct Exposure - Industrial column)","Note: If more than one contaminant is present at a site, the direct exposure values are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Appendix D 'Draft Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.', dated February 2005."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","section":"Ch. 62-777 F.A.C. Table II, Soil Cleanup Target Levels, Direct Exposure - Industrial (DEP spreadsheet, sheet TTable2, row 130)","page":null,"quote":"row 130: Copper | -Gastrointestinal  | 7440-50-8 | 150** | 89000 | *** | NA | *** | ***"}},{"id":"a4c0e58c1b6b0c37","parameter":"Copper","value":"Cu ≤ e(0.8545[lnH]- 1.702)","unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-50-8","place":["US-FL"],"conditions":["receiving_water is freshwater","Class I, potable water supplies (waters listed by name in 62-302.400, F.A.C.)"],"cite":{"instrument":"us_fl_wqs","title":"F.A.C. 62-302.530 Table: Surface Water Quality Criteria (Florida) — Class I, II, III fresh, III marine and IV criteria","issuer":"State of Florida, Department of Environmental Protection (Environmental Regulation Commission)","edition":"Chapter 62-302, F.A.C., as US EPA posts it in effect for Clean Water Act purposes; 62-302.530 amended through 11-25-25 (its history note, p. 45); EPA's re-posting of 2026-10-05 (PDF CreationDate), fetched 2026-10-15","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/fl_section62-302.pdf","source_sha256":"9865f1a6486a9332278c619fbcd71dc9f4f19af10e39576eea8ae900136aa284","fetched_at":"2026-10-15","section":"F.A.C. 62-302.530(23)","page":34,"quote":null}},{"id":"60013cd97c3ce9eb","parameter":"Copper","value":"≤ 3.7","value_num":3.7,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-50-8","place":["US-FL"],"conditions":["receiving_water is marine","Class II, shellfish propagation or harvesting (waters listed by name in 62-302.400, F.A.C.)"],"cite":{"instrument":"us_fl_wqs","title":"F.A.C. 62-302.530 Table: Surface Water Quality Criteria (Florida) — Class I, II, III fresh, III marine and IV criteria","issuer":"State of Florida, Department of Environmental Protection (Environmental Regulation Commission)","edition":"Chapter 62-302, F.A.C., as US EPA posts it in effect for Clean Water Act purposes; 62-302.530 amended through 11-25-25 (its history note, p. 45); EPA's re-posting of 2026-10-05 (PDF CreationDate), fetched 2026-10-15","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/fl_section62-302.pdf","source_sha256":"9865f1a6486a9332278c619fbcd71dc9f4f19af10e39576eea8ae900136aa284","fetched_at":"2026-10-15","section":"F.A.C. 62-302.530(23)","page":34,"quote":null}},{"id":"03987d734a3987de","parameter":"Copper","value":"Cu ≤ e(0.8545[lnH]- 1.702)","unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-50-8","place":["US-FL"],"conditions":["receiving_water is freshwater","Class III and Class III-Limited, predominantly fresh waters (every Florida surface water not listed in 62-302.400, F.A.C., is Class III)"],"cite":{"instrument":"us_fl_wqs","title":"F.A.C. 62-302.530 Table: Surface Water Quality Criteria (Florida) — Class I, II, III fresh, III marine and IV criteria","issuer":"State of Florida, Department of Environmental Protection (Environmental Regulation Commission)","edition":"Chapter 62-302, F.A.C., as US EPA posts it in effect for Clean Water Act purposes; 62-302.530 amended through 11-25-25 (its history note, p. 45); EPA's re-posting of 2026-10-05 (PDF CreationDate), fetched 2026-10-15","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/fl_section62-302.pdf","source_sha256":"9865f1a6486a9332278c619fbcd71dc9f4f19af10e39576eea8ae900136aa284","fetched_at":"2026-10-15","section":"F.A.C. 62-302.530(23)","page":34,"quote":null}},{"id":"566c47f49814aeb9","parameter":"Copper","value":"≤ 3.7","value_num":3.7,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-50-8","place":["US-FL"],"conditions":["receiving_water is marine","Class III and Class III-Limited, predominantly marine waters (every Florida surface water not listed in 62-302.400, F.A.C., is Class III)"],"cite":{"instrument":"us_fl_wqs","title":"F.A.C. 62-302.530 Table: Surface Water Quality Criteria (Florida) — Class I, II, III fresh, III marine and IV criteria","issuer":"State of Florida, Department of Environmental Protection (Environmental Regulation Commission)","edition":"Chapter 62-302, F.A.C., as US EPA posts it in effect for Clean Water Act purposes; 62-302.530 amended through 11-25-25 (its history note, p. 45); EPA's re-posting of 2026-10-05 (PDF CreationDate), fetched 2026-10-15","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/fl_section62-302.pdf","source_sha256":"9865f1a6486a9332278c619fbcd71dc9f4f19af10e39576eea8ae900136aa284","fetched_at":"2026-10-15","section":"F.A.C. 62-302.530(23)","page":34,"quote":null}},{"id":"f22a37f25d8d377a","parameter":"Copper","value":"< 500","value_num":500,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-50-8","place":["US-FL"],"conditions":["receiving_water is freshwater","Class IV, agricultural water supplies (waters listed by name in 62-302.400, F.A.C.)"],"cite":{"instrument":"us_fl_wqs","title":"F.A.C. 62-302.530 Table: Surface Water Quality Criteria (Florida) — Class I, II, III fresh, III marine and IV criteria","issuer":"State of Florida, Department of Environmental Protection (Environmental Regulation Commission)","edition":"Chapter 62-302, F.A.C., as US EPA posts it in effect for Clean Water Act purposes; 62-302.530 amended through 11-25-25 (its history note, p. 45); EPA's re-posting of 2026-10-05 (PDF CreationDate), fetched 2026-10-15","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/fl_section62-302.pdf","source_sha256":"9865f1a6486a9332278c619fbcd71dc9f4f19af10e39576eea8ae900136aa284","fetched_at":"2026-10-15","section":"F.A.C. 62-302.530(23)","page":34,"quote":null}},{"id":"9da5e0b2708a22ce","parameter":"Copper cyanide","value":"35","value_num":35,"unit":"µg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:544-92-3","place":["US-FL"],"conditions":["groundwater (Table I, Groundwater Criteria column)","Note: If more than one contaminant is present at a site, CTLs are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Figure 10 of the February 2005 'Final Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.' However, GCTLs for primary and secondary standards shall not be modified."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","section":"Ch. 62-777 F.A.C. Table I, Groundwater and Surface Water Cleanup Target Levels, Groundwater Criteria (DEP spreadsheet, sheet TTable1, row 140)","page":null,"quote":"row 140: Copper cyanide | 35 |  |  | 350 | -Kidney  | 544-92-3 |  | Minimum Criteria | NA | NA |  | Systemic Toxicant"}},{"id":"90ab6e81728b9d5b","parameter":"Copper cyanide","value":"350","value_num":350,"unit":"µg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:544-92-3","place":["US-FL"],"conditions":["groundwater of low yield/poor quality (Table I, Groundwater of Low Yield/Poor Quality Criteria column)","Note: If more than one contaminant is present at a site, CTLs are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Figure 10 of the February 2005 'Final Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.' However, GCTLs for primary and secondary standards shall not be modified."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","section":"Ch. 62-777 F.A.C. Table I, Groundwater and Surface Water Cleanup Target Levels, Groundwater of Low Yield/Poor Quality Criteria (DEP spreadsheet, sheet TTable1, row 140)","page":null,"quote":"row 140: Copper cyanide | 35 |  |  | 350 | -Kidney  | 544-92-3 |  | Minimum Criteria | NA | NA |  | Systemic Toxicant"}},{"id":"256b028254b2bd82","parameter":"Cu","value":"4.5","value_num":4.5,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"16008a3c68209ada","parameter":"Cu","value":"2.7","value_num":2.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"22cbbea24b9da5bd","parameter":"Cu","value":"176","value_num":176,"unit":"mg/sq m-Operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may be applied in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"e21e1440752d2fc6","parameter":"Cu","value":"105","value_num":105,"unit":"mg/sq m-Operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may be applied in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"6ea14ea54f3404ca","parameter":"Cu","value":"4.5","value_num":4.5,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"40fa2c2f9b66b590","parameter":"Cu","value":"2.7","value_num":2.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"ed2ccb34fe0adb7b","parameter":"Cu","value":"176","value_num":176,"unit":"mg/sq m-Operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"f145e8fc6f26a53d","parameter":"Cu","value":"105","value_num":105,"unit":"mg/sq m-Operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"5c6869e8f7ce9806","parameter":"Cu","value":"4.5","value_num":4.5,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart D—Anodizing Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.44 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"6dd371e566f55874","parameter":"Cu","value":"2.7","value_num":2.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart D—Anodizing Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.44 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"6352db9ea086c87e","parameter":"Cu","value":"176","value_num":176,"unit":"mg/sq m-operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart D—Anodizing Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.44 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"119d18207921d6c5","parameter":"Cu","value":"105","value_num":105,"unit":"mg/sq m-operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart D—Anodizing Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.44 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"a04eb045e0431ca0","parameter":"Cu","value":"4.5","value_num":4.5,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart E—Coatings Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart E—Coatings Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.54 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"d5e0c3452c44b939","parameter":"Cu","value":"2.7","value_num":2.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart E—Coatings Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart E—Coatings Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.54 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"98efabf4c365118e","parameter":"Cu","value":"176","value_num":176,"unit":"mg/sq m-operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart E—Coatings Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart E—Coatings Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.54 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"84cb6bb97d7e1abe","parameter":"Cu","value":"105","value_num":105,"unit":"mg/sq m-operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart E—Coatings Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart E—Coatings Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.54 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"b46fca74c592bbf3","parameter":"Cu","value":"4.5","value_num":4.5,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart F—Chemical Etching and Milling Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal.) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart F—Chemicals Etching and Milling Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.64 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"0a4e32ffeb266cc6","parameter":"Cu","value":"2.7","value_num":2.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart F—Chemical Etching and Milling Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal.) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart F—Chemicals Etching and Milling Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.64 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"26dd6ba74da398d9","parameter":"Cu","value":"176","value_num":176,"unit":"mg/sq m-operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart F—Chemical Etching and Milling Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart F—Chemical Etching and Milling Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.64 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"80c73ca2b7b8171a","parameter":"Cu","value":"105","value_num":105,"unit":"mg/sq m-operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart F—Chemical Etching and Milling Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart F—Chemical Etching and Milling Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.64 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"22bdccfc00a3f2f4","parameter":"Cu","value":"4.5","value_num":4.5,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart G—Electroless Plating Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 l (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart G—Electroless Plating Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.74 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"13e953b81a11b746","parameter":"Cu","value":"2.7","value_num":2.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart G—Electroless Plating Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 l (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart G—Electroless Plating Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.74 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"302ae1967556fe7e","parameter":"Cu","value":"176","value_num":176,"unit":"mg/sq m-operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart G—Electroless Plating Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart G—Electroless Plating Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.74 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"6e74633e7b275fb3","parameter":"Cu","value":"105","value_num":105,"unit":"mg/sq m-operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart G—Electroless Plating Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart G—Electroless Plating Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.74 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"b57973496f4c755d","parameter":"Cu","value":"4.5","value_num":4.5,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart H—Printed Circuit Board Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart H—Printed Circuit Board Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.84 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"6ae65dbc345850e8","parameter":"Cu","value":"2.7","value_num":2.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart H—Printed Circuit Board Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart H—Printed Circuit Board Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.84 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"005c56a3cfc79e0b","parameter":"Cu","value":"401","value_num":401,"unit":"mg/sq m-operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart H—Printed Circuit Board Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart H—Printed Circuit Board Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.84 (PSES)","page":null,"quote":"Cu 401 241"}},{"id":"943febff3ebef50f","parameter":"Cu","value":"241","value_num":241,"unit":"mg/sq m-operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart H—Printed Circuit Board Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart H—Printed Circuit Board Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 413.84 (PSES)","page":null,"quote":"Cu 401 241"}},{"id":"036e4093649d6c33","parameter":"Total Copper","value":"3,380","value_num":3380,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment","existing sources (BAT)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.91 (BAT)","page":null,"quote":"Total Copper 3,380 1,450"}},{"id":"0470f7ffd030047d","parameter":"Total Copper","value":"3,380","value_num":3380,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment","new sources (NSPS)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.91 (NSPS)","page":null,"quote":"Total Copper 3,380 1,450"}},{"id":"10b18d87908d1d1f","parameter":"Total Copper","value":"1,450","value_num":1450,"unit":"µg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment","existing sources (BAT)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.91 (BAT)","page":null,"quote":"Total Copper 3,380 1,450"}},{"id":"92494cc88bb23b04","parameter":"Total Copper","value":"1,450","value_num":1450,"unit":"µg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment","new sources (NSPS)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.91 (NSPS)","page":null,"quote":"Total Copper 3,380 1,450"}},{"id":"561dd36d9452bbfe","parameter":"Total Copper","value":"3,380","value_num":3380,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment","existing sources (BAT)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.101 (BAT)","page":null,"quote":"Total Copper 3,380 1,450"}},{"id":"95ee697f99c92d7a","parameter":"Total Copper","value":"3,380","value_num":3380,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment","new sources (NSPS)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.101 (NSPS)","page":null,"quote":"Total Copper 3,380 1,450"}},{"id":"4760e5810eebca73","parameter":"Total Copper","value":"1,450","value_num":1450,"unit":"µg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment","existing sources (BAT)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.101 (BAT)","page":null,"quote":"Total Copper 3,380 1,450"}},{"id":"ca638e1a500d7203","parameter":"Total Copper","value":"1,450","value_num":1450,"unit":"µg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment","new sources (NSPS)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 414.101 (NSPS)","page":null,"quote":"Total Copper 3,380 1,450"}},{"id":"cb2caa88ac7bf5ac","parameter":"Copper (T)","value":"0.018","value_num":0.018,"unit":"Kg/kkg (or pounds per/1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart F—Chlor-alkali Subcategory (Chlorine and Sodium or Potassium Hydroxide Production)","existing sources (BPT)","table: Subpart F—Chlor-Alkali Diaphragm Cells"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.62 (BPT)","page":null,"quote":"Copper (T) 0.018 0.0070"}},{"id":"a65962785d0deea9","parameter":"Copper (T)","value":"0.0070","value_num":0.007,"unit":"Kg/kkg (or pounds per/1,000 lb) of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart F—Chlor-alkali Subcategory (Chlorine and Sodium or Potassium Hydroxide Production)","existing sources (BPT)","table: Subpart F—Chlor-Alkali Diaphragm Cells"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.62 (BPT)","page":null,"quote":"Copper (T) 0.018 0.0070"}}],"next":[{"tool":"check_values","says":"Has your user measured this? check_values sets each of their results beside every row held here, with a verdict and the row's cite.","arguments":{"place":"US-FL"},"needs":{"rows":"Your user's measured results, as their table prints them: [{parameter: \"copper\", value, unit}, ...], any other parameters too."},"post":"/api/v1/check"},{"tool":"read_certificate","says":"Has your user a laboratory certificate? read_certificate reads every row it prints, each with its page, and checks them against these limits.","arguments":{"place":"US-FL"},"needs":{"content_base64":"The laboratory's certificate (PDF) or its XLSX, XLS or CSV export, as base64; or file_url, a public https address of it."},"post":"/api/v1/certificate"}]}