{"query":{"parameter":"chromium vi","place":"US-TX","medium":null,"statistic":null,"kind":null},"searched":{"places":["US-TX","US"],"parameter_keys":["cas:18540-29-9","name:chromium (vi) (freshwater) chromium (vi) marine","cas:7440-47-3","name:chromium (+6)","name:chromium +6","name:chromium +6, total"],"names_matched":[["chromium vi","cas:18540-29-9"],["chromium vi freshwater chromium vi marine","name:chromium (vi) (freshwater) chromium (vi) marine"],["chromium 6","cas:7440-47-3","chromium 6"],["chromium 6","name:chromium (+6)","chromium 6"],["chromium 6","name:chromium +6","chromium 6"],["chromium 6 total","name:chromium +6, total","chromium 6"],["chromium 6 total recoverable","name:chromium (+6)","chromium 6"]],"match":"exact+contains","order":"The place's own instruments first, then each place above it, each in its register's order","not_sent":{"rows":2538,"names":["Chromium","Chromium (total)","Total chromium","Total Chromium","Chromium (Total)","Chromium (T)","Cr","Chromium, total"],"says":"2538 rows share a parameter key with a longer name holding \"chromium vi\" but are printed under names without these words (that key is wider than the name), or keyed to a CAS number \"chromium vi\" does not name (another substance, whatever words its name holds): not sent. Ask for one by its name or CAS number."}},"total":170,"offset":0,"returned":50,"next_offset":50,"rows":[{"id":"e7c422a6fe1edfd1","parameter":"Chromium (VI)","value":"1.2E+02","value_num":120,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:18540-29-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 1, Residential Soil, TotSoilComb, 0.5 acre source area","page":12,"quote":null}},{"id":"756e26e060174d19","parameter":"Chromium (VI)","value":"2.8E+01","value_num":28,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:18540-29-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 1, Residential Soil, GWSoilIng, 0.5 acre source area","page":12,"quote":null}},{"id":"9f866b49c751e693","parameter":"Chromium (VI)","value":"2.8E+03","value_num":2800,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:18540-29-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 1, Residential Soil, GWSoilClass 3, 0.5 acre source area","page":12,"quote":null}},{"id":"694b48d7d7300d06","parameter":"Chromium (VI)","value":"1.2E+02","value_num":120,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:18540-29-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 1, Residential Soil, TotSoilComb, 30 acre source area","page":12,"quote":null}},{"id":"9b33ae6d14e28a52","parameter":"Chromium (VI)","value":"1.4E+01","value_num":14,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:18540-29-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 1, Residential Soil, GWSoilIng, 30 acre source area","page":12,"quote":null}},{"id":"e36b96e2bf67716a","parameter":"Chromium (VI)","value":"1.4E+03","value_num":1400,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:18540-29-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 1, Residential Soil, GWSoilClass 3, 30 acre source area","page":12,"quote":null}},{"id":"7531b063895dbee0","parameter":"Chromium (VI)","value":"1.0E+03","value_num":1000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:18540-29-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 2, Commercial/Industrial Soil, TotSoilComb, 0.5 acre source area","page":27,"quote":null}},{"id":"19f107f5628c947c","parameter":"Chromium (VI)","value":"2.8E+01","value_num":28,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:18540-29-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 2, Commercial/Industrial Soil, GWSoilIng, 0.5 acre source area","page":27,"quote":null}},{"id":"df679f1b67f1e77e","parameter":"Chromium (VI)","value":"2.8E+03","value_num":2800,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:18540-29-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 2, Commercial/Industrial Soil, GWSoilClass 3, 0.5 acre source area","page":27,"quote":null}},{"id":"db826709900857d5","parameter":"Chromium (VI)","value":"1.0E+03","value_num":1000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:18540-29-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 2, Commercial/Industrial Soil, TotSoilComb, 30 acre source area","page":27,"quote":null}},{"id":"bcaba6e9241069d6","parameter":"Chromium (VI)","value":"1.4E+01","value_num":14,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:18540-29-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 2, Commercial/Industrial Soil, GWSoilIng, 30 acre source area","page":27,"quote":null}},{"id":"f9c825b0fe7a81e3","parameter":"Chromium (VI)","value":"1.4E+03","value_num":1400,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:18540-29-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 2, Commercial/Industrial Soil, GWSoilClass 3, 30 acre source area","page":27,"quote":null}},{"id":"5e85990500b92a79","parameter":"Chromium (VI)","value":"1.0E-01","value_num":0.1,"unit":"mg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:18540-29-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 3, Groundwater, GWGWIng, Residential","page":41,"quote":null}},{"id":"f5f266b16c833291","parameter":"Chromium (VI)","value":"1.0E+01","value_num":10,"unit":"mg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:18540-29-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 3, Groundwater, GWGWClass3, Residential","page":41,"quote":null}},{"id":"15552112c9d62068","parameter":"Chromium (VI)","value":"1.0E-01","value_num":0.1,"unit":"mg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:18540-29-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 3, Groundwater, GWGWIng, Commercial/Industrial","page":41,"quote":null}},{"id":"5738b715b4612bd8","parameter":"Chromium (VI)","value":"1.0E+01","value_num":10,"unit":"mg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:18540-29-9","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 3, Groundwater, GWGWClass3, Commercial/Industrial","page":41,"quote":null}},{"id":"9b0f495eb2ca03a5","parameter":"Chromium (Hex)","value":"15.7w","value_num":15.7,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:18540-29-9","place":["US-TX"],"conditions":["receiving_water is freshwater","water in the state; acute criteria outside zones of initial dilution, chronic criteria in water with an aquatic life use of limited or greater, outside mixing zones and above critical low flow (30 TAC §307.6(c)(6))"],"cite":{"instrument":"us_tx_wqs","title":"Texas Surface Water Quality Standards, 30 TAC Chapter 307 (2022): §307.6 Table 1 aquatic life (freshwater and saltwater acute/chronic) and Table 2 human health; §307.7 Table 3 dissolved oxygen","issuer":"State of Texas, Texas Commission on Environmental Quality (TCEQ)","edition":"2022 Texas Surface Water Quality Standards (Rule Project No. 2020-014-307-OW), effective June 27, 2025, as US EPA posts them (cover dated July 1, 2025) with what EPA has approved for CWA purposes","source_url":"https://www.epa.gov/system/files/documents/2023-12/txwqs-2022.pdf","source_sha256":"88ff93dcfb277feec248541b2aa9a0f01cd3a747cda6e03d958344ee4a34ce5e","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"30 TAC §307.6(c) Table 1","page":37,"quote":null}},{"id":"0bee20c3ec523158","parameter":"Chromium (Hex)","value":"10.6w","value_num":10.6,"unit":"µg/L","statistic":"weekly_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:18540-29-9","place":["US-TX"],"conditions":["receiving_water is freshwater","water in the state; acute criteria outside zones of initial dilution, chronic criteria in water with an aquatic life use of limited or greater, outside mixing zones and above critical low flow (30 TAC §307.6(c)(6))"],"cite":{"instrument":"us_tx_wqs","title":"Texas Surface Water Quality Standards, 30 TAC Chapter 307 (2022): §307.6 Table 1 aquatic life (freshwater and saltwater acute/chronic) and Table 2 human health; §307.7 Table 3 dissolved oxygen","issuer":"State of Texas, Texas Commission on Environmental Quality (TCEQ)","edition":"2022 Texas Surface Water Quality Standards (Rule Project No. 2020-014-307-OW), effective June 27, 2025, as US EPA posts them (cover dated July 1, 2025) with what EPA has approved for CWA purposes","source_url":"https://www.epa.gov/system/files/documents/2023-12/txwqs-2022.pdf","source_sha256":"88ff93dcfb277feec248541b2aa9a0f01cd3a747cda6e03d958344ee4a34ce5e","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"30 TAC §307.6(c) Table 1","page":37,"quote":null}},{"id":"a757f02b71631ae3","parameter":"Chromium (Hex)","value":"1,090w","value_num":1090,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:18540-29-9","place":["US-TX"],"conditions":["receiving_water is marine","water in the state; acute criteria outside zones of initial dilution, chronic criteria in water with an aquatic life use of limited or greater, outside mixing zones and above critical low flow (30 TAC §307.6(c)(6))"],"cite":{"instrument":"us_tx_wqs","title":"Texas Surface Water Quality Standards, 30 TAC Chapter 307 (2022): §307.6 Table 1 aquatic life (freshwater and saltwater acute/chronic) and Table 2 human health; §307.7 Table 3 dissolved oxygen","issuer":"State of Texas, Texas Commission on Environmental Quality (TCEQ)","edition":"2022 Texas Surface Water Quality Standards (Rule Project No. 2020-014-307-OW), effective June 27, 2025, as US EPA posts them (cover dated July 1, 2025) with what EPA has approved for CWA purposes","source_url":"https://www.epa.gov/system/files/documents/2023-12/txwqs-2022.pdf","source_sha256":"88ff93dcfb277feec248541b2aa9a0f01cd3a747cda6e03d958344ee4a34ce5e","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"30 TAC §307.6(c) Table 1","page":37,"quote":null}},{"id":"3621fe8ef2fcd72b","parameter":"Chromium (Hex)","value":"49.6w","value_num":49.6,"unit":"µg/L","statistic":"weekly_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:18540-29-9","place":["US-TX"],"conditions":["receiving_water is marine","water in the state; acute criteria outside zones of initial dilution, chronic criteria in water with an aquatic life use of limited or greater, outside mixing zones and above critical low flow (30 TAC §307.6(c)(6))"],"cite":{"instrument":"us_tx_wqs","title":"Texas Surface Water Quality Standards, 30 TAC Chapter 307 (2022): §307.6 Table 1 aquatic life (freshwater and saltwater acute/chronic) and Table 2 human health; §307.7 Table 3 dissolved oxygen","issuer":"State of Texas, Texas Commission on Environmental Quality (TCEQ)","edition":"2022 Texas Surface Water Quality Standards (Rule Project No. 2020-014-307-OW), effective June 27, 2025, as US EPA posts them (cover dated July 1, 2025) with what EPA has approved for CWA purposes","source_url":"https://www.epa.gov/system/files/documents/2023-12/txwqs-2022.pdf","source_sha256":"88ff93dcfb277feec248541b2aa9a0f01cd3a747cda6e03d958344ee4a34ce5e","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"30 TAC §307.6(c) Table 1","page":37,"quote":null}},{"id":"9ac4245cf0fac257","parameter":"Chromium (Hex)","value":"62","value_num":62,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:18540-29-9","place":["US-TX"],"conditions":["surface water designated or used for public drinking water supply, or a sole-source surface drinking water supply (30 TAC §307.6(d)(2)(A), Column A)"],"cite":{"instrument":"us_tx_wqs","title":"Texas Surface Water Quality Standards, 30 TAC Chapter 307 (2022): §307.6 Table 1 aquatic life (freshwater and saltwater acute/chronic) and Table 2 human health; §307.7 Table 3 dissolved oxygen","issuer":"State of Texas, Texas Commission on Environmental Quality (TCEQ)","edition":"2022 Texas Surface Water Quality Standards (Rule Project No. 2020-014-307-OW), effective June 27, 2025, as US EPA posts them (cover dated July 1, 2025) with what EPA has approved for CWA purposes","source_url":"https://www.epa.gov/system/files/documents/2023-12/txwqs-2022.pdf","source_sha256":"88ff93dcfb277feec248541b2aa9a0f01cd3a747cda6e03d958344ee4a34ce5e","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"30 TAC §307.6(d) Table 2","page":47,"quote":null}},{"id":"aef93a4ddae74394","parameter":"Chromium (Hex)","value":"502","value_num":502,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:18540-29-9","place":["US-TX"],"conditions":["surface water with a sustainable fishery not designated or used for public water supply (30 TAC §307.6(d)(2)(B), Column B); in an incidental fishery the criterion is ten times this value (30 TAC §307.6(d)(6))"],"cite":{"instrument":"us_tx_wqs","title":"Texas Surface Water Quality Standards, 30 TAC Chapter 307 (2022): §307.6 Table 1 aquatic life (freshwater and saltwater acute/chronic) and Table 2 human health; §307.7 Table 3 dissolved oxygen","issuer":"State of Texas, Texas Commission on Environmental Quality (TCEQ)","edition":"2022 Texas Surface Water Quality Standards (Rule Project No. 2020-014-307-OW), effective June 27, 2025, as US EPA posts them (cover dated July 1, 2025) with what EPA has approved for CWA purposes","source_url":"https://www.epa.gov/system/files/documents/2023-12/txwqs-2022.pdf","source_sha256":"88ff93dcfb277feec248541b2aa9a0f01cd3a747cda6e03d958344ee4a34ce5e","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"30 TAC §307.6(d) Table 2","page":47,"quote":null}},{"id":"586a491f98bacb89","parameter":"Hexavalent chromium","value":"0.25","value_num":0.25,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart L—Potassium Dichromate Production Subcategory","existing sources (PSES)","table: Subpart L—Potassium Dichromate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 415.124 (PSES)","page":null,"quote":"Hexavalent chromium 0.25 0.090"}},{"id":"80c65545de24faef","parameter":"Hexavalent chromium","value":"0.090","value_num":0.09,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart L—Potassium Dichromate Production Subcategory","existing sources (PSES)","table: Subpart L—Potassium Dichromate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 415.124 (PSES)","page":null,"quote":"Hexavalent chromium 0.25 0.090"}},{"id":"44301cb82638239a","parameter":"Hexavalent Chromium","value":"0.00090","value_num":0.0009,"unit":"Kg/kkg (or pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart Q—Sodium Dichromate and Sodium Sulfate Production Subcategory","existing sources (BPT)","table: Subpart Q—Sodium Dichromate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 415.172 (BPT)","page":null,"quote":"Hexavalent Chromium 0.00090 0.00050"}},{"id":"e684d0fc30e3fb2e","parameter":"Hexavalent Chromium","value":"0.00050","value_num":0.0005,"unit":"Kg/kkg (or pounds per 1,000 lb) of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart Q—Sodium Dichromate and Sodium Sulfate Production Subcategory","existing sources (BPT)","table: Subpart Q—Sodium Dichromate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 415.172 (BPT)","page":null,"quote":"Hexavalent Chromium 0.00090 0.00050"}},{"id":"e4dade62badb7d43","parameter":"Hexavalent Chromium","value":"0.11","value_num":0.11,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart Q—Sodium Dichromate and Sodium Sulfate Production Subcategory","new sources (PSNS)","table: Subpart Q—Sodium Dichromate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 415.176 (PSNS)","page":null,"quote":"Hexavalent Chromium 0.11 0.060"}},{"id":"3db527f50ed7c0c9","parameter":"Hexavalent Chromium","value":"0.060","value_num":0.06,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart Q—Sodium Dichromate and Sodium Sulfate Production Subcategory","new sources (PSNS)","table: Subpart Q—Sodium Dichromate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 415.176 (PSNS)","page":null,"quote":"Hexavalent Chromium 0.11 0.060"}},{"id":"ac5fe4fc7e451cb8","parameter":"Hexavalent Chromium","value":"0.25","value_num":0.25,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart AL—Ferric Chloride Production Subcategory","existing sources (PSES)","table: Subpart AL—Ferric Chloride"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 415.384 (PSES)","page":null,"quote":"Hexavalent Chromium 0.25 0.09"}},{"id":"bbc4a35bef16796d","parameter":"Hexavalent Chromium","value":"0.09","value_num":0.09,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart AL—Ferric Chloride Production Subcategory","existing sources (PSES)","table: Subpart AL—Ferric Chloride"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 415.384 (PSES)","page":null,"quote":"Hexavalent Chromium 0.25 0.09"}},{"id":"8e0092fd8ade30fc","parameter":"Hexavalent chromium","value":"0.028","value_num":0.028,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.12 (BPT)","page":null,"quote":"Hexavalent chromium 0.028 0.012"}},{"id":"5675ce4c2773c41c","parameter":"Hexavalent chromium","value":"0.012","value_num":0.012,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.12 (BPT)","page":null,"quote":"Hexavalent chromium 0.028 0.012"}},{"id":"a5c170365a595d95","parameter":"Hexavalent chromium","value":"0.062","value_num":0.062,"unit":"kilograms per 1,000 m³ of flow","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BPT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by th…"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.12 (BPT)","page":null,"quote":"Hexavalent chromium 0.062 0.028"}},{"id":"57a3d27a2709f0fb","parameter":"Hexavalent chromium","value":"0.028","value_num":0.028,"unit":"kilograms per 1,000 m³ of flow","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BPT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by th…"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.12 (BPT)","page":null,"quote":"Hexavalent chromium 0.062 0.028"}},{"id":"f7aa6927893b9926","parameter":"Hexavalent chromium","value":"0.0019","value_num":0.0019,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Crude"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Crude 0.0019 0.0009"}},{"id":"a0641b29156d1dcf","parameter":"Hexavalent chromium","value":"0.0009","value_num":0.0009,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Crude"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Crude 0.0019 0.0009"}},{"id":"cb746acdf3ee94fc","parameter":"Hexavalent chromium","value":"0.0218","value_num":0.0218,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Cracking and coking"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Cracking and coking 0.0218 0.0098"}},{"id":"1ddda5fac1059bee","parameter":"Hexavalent chromium","value":"0.0098","value_num":0.0098,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Cracking and coking"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Cracking and coking 0.0218 0.0098"}},{"id":"6861827fb0da18f1","parameter":"Hexavalent chromium","value":"0.0117","value_num":0.0117,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Asphalt"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Asphalt 0.0117 0.0053"}},{"id":"f831dc28ef48615f","parameter":"Hexavalent chromium","value":"0.0053","value_num":0.0053,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Asphalt"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Asphalt 0.0117 0.0053"}},{"id":"52d8f1f5a9e229bf","parameter":"Hexavalent chromium","value":"0.0549","value_num":0.0549,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Lube"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Lube 0.0549 0.0248"}},{"id":"b05e64665a23de5a","parameter":"Hexavalent chromium","value":"0.0248","value_num":0.0248,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Lube"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Lube 0.0549 0.0248"}},{"id":"0019d027dc08b268","parameter":"Hexavalent chromium","value":"0.0196","value_num":0.0196,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Reforming and alkylation"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Reforming and alkylation 0.0196 0.0088"}},{"id":"68fa7b81afc4c94c","parameter":"Hexavalent chromium","value":"0.0088","value_num":0.0088,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Reforming and alkylation"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Reforming and alkylation 0.0196 0.0088"}},{"id":"3a1f5e0f74cba875","parameter":"Hexavalent chromium","value":"0.062","value_num":0.062,"unit":"kilograms per 1,000 m³ of flow","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the permit writer times the …"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Hexavalent chromium 0.062 0.028"}},{"id":"16cc83d20ea9fd1e","parameter":"Hexavalent chromium","value":"0.028","value_num":0.028,"unit":"kilograms per 1,000 m³ of flow","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the permit writer times the …"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Hexavalent chromium 0.062 0.028"}},{"id":"f8ce2214c9c13e87","parameter":"Hexavalent chromium","value":"0.015","value_num":0.015,"unit":"kilograms per cubic meter of flow","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","new sources (NSPS)","(a) Any new source subject to this subpart must achieve the following new source performance standards (NSPS):"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.16 (NSPS)","page":null,"quote":"Hexavalent chromium 0.015 0.0068"}},{"id":"fe6afefbdfe84ab5","parameter":"Hexavalent chromium","value":"0.0068","value_num":0.0068,"unit":"kilograms per cubic meter of flow","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","new sources (NSPS)","(a) Any new source subject to this subpart must achieve the following new source performance standards (NSPS):"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.16 (NSPS)","page":null,"quote":"Hexavalent chromium 0.015 0.0068"}},{"id":"93f79981d38f7f8d","parameter":"Hexavalent chromium","value":"0.035","value_num":0.035,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.22 (BPT)","page":null,"quote":"Hexavalent chromium 0.035 0.016"}},{"id":"fecd421c87b4153a","parameter":"Hexavalent chromium","value":"0.016","value_num":0.016,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.22 (BPT)","page":null,"quote":"Hexavalent chromium 0.035 0.016"}}],"next":[{"tool":"check_values","says":"Has your user measured this? check_values sets each of their results beside every row held here, with a verdict and the row's cite.","arguments":{"place":"US-TX"},"needs":{"rows":"Your user's measured results, as their table prints them: [{parameter: \"chromium vi\", value, unit}, ...], any other parameters too."},"post":"/api/v1/check"},{"tool":"read_certificate","says":"Has your user a laboratory certificate? read_certificate reads every row it prints, each with its page, and checks them against these limits.","arguments":{"place":"US-TX"},"needs":{"content_base64":"The laboratory's certificate (PDF) or its XLSX, XLS or CSV export, as base64; or file_url, a public https address of it."},"post":"/api/v1/certificate"}]}