{"query":{"parameter":"chromium vi","place":"US-NY","medium":null,"statistic":null,"kind":null},"searched":{"places":["US-NY","US"],"parameter_keys":["cas:18540-29-9","name:chromium (vi) (freshwater) chromium (vi) marine","cas:7440-47-3","name:chromium (+6)","name:chromium +6","name:chromium +6, total"],"names_matched":[["chromium vi","cas:18540-29-9"],["chromium vi freshwater chromium vi marine","name:chromium (vi) (freshwater) chromium (vi) marine"],["chromium 6","cas:7440-47-3","chromium 6"],["chromium 6","name:chromium (+6)","chromium 6"],["chromium 6","name:chromium +6","chromium 6"],["chromium 6 total","name:chromium +6, total","chromium 6"],["chromium 6 total recoverable","name:chromium (+6)","chromium 6"]],"match":"exact+contains","order":"The place's own instruments first, then each place above it, each in its register's order","not_sent":{"rows":2525,"names":["Chromium","Chromium (total)","Total chromium","Total Chromium","Chromium (Total)","Chromium (T)","Cr","Chromium, total"],"says":"2525 rows share a parameter key with a longer name holding \"chromium vi\" but are printed under names without these words (that key is wider than the name), or keyed to a CAS number \"chromium vi\" does not name (another substance, whatever words its name holds): not sent. Ask for one by its name or CAS number."}},"total":152,"offset":0,"returned":50,"next_offset":50,"rows":[{"id":"b00730b6c707fbe2","parameter":"Chromium (hexavalent)","value":"11*","value_num":11,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:18540-29-9","place":["US-NY"],"conditions":["receiving_water is freshwater","New York classes A, A-S, AA, AA-S, B, C (fresh waters; 6 NYCRR Part 701)"],"cite":{"instrument":"us_ny_wqs","title":"6 NYCRR 703.5 Table 1 water quality standards (as DEC TOGS 1.1.1 reprints them) and 703.3 pH, dissolved oxygen and dissolved solids (New York)","issuer":"State of New York, Department of Environmental Conservation","edition":"DEC Division of Water TOGS 1.1.1, reissued June 1998 (the 703.5 standards as revised effective March 12, 1998); 703.3 from 6 NYCRR Parts 700-706 as US EPA posts them in effect for CWA purposes (effective December 20, 2024)","source_url":"https://dec.ny.gov/docs/water_pdf/togs111.pdf","source_sha256":"090692f43a82280ffbf75751ecc52b94fc2d5c78996f9dc2483152343f8f4d59","fetched_at":"2026-10-10","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"6 NYCRR 703.5(f) Table 1","page":26,"quote":"Chromium (hexavalent) GA 50 H(WS) F (CAS No. Not Applicable) A, A-S, AA, AA-S, B, C 11* A(C)"}},{"id":"f517a5167fa5be6d","parameter":"Chromium (hexavalent)","value":"16*","value_num":16,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:18540-29-9","place":["US-NY"],"conditions":["receiving_water is freshwater","New York classes A, A-S, AA, AA-S, B, C, D (fresh waters; 6 NYCRR Part 701)"],"cite":{"instrument":"us_ny_wqs","title":"6 NYCRR 703.5 Table 1 water quality standards (as DEC TOGS 1.1.1 reprints them) and 703.3 pH, dissolved oxygen and dissolved solids (New York)","issuer":"State of New York, Department of Environmental Conservation","edition":"DEC Division of Water TOGS 1.1.1, reissued June 1998 (the 703.5 standards as revised effective March 12, 1998); 703.3 from 6 NYCRR Parts 700-706 as US EPA posts them in effect for CWA purposes (effective December 20, 2024)","source_url":"https://dec.ny.gov/docs/water_pdf/togs111.pdf","source_sha256":"090692f43a82280ffbf75751ecc52b94fc2d5c78996f9dc2483152343f8f4d59","fetched_at":"2026-10-10","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"6 NYCRR 703.5(f) Table 1","page":26,"quote":"Chromium (hexavalent) GA 50 H(WS) F (CAS No. Not Applicable) A, A-S, AA, AA-S, B, C 11* A(C) A, A-S, AA, AA-S, B, C, D 16* A(A)"}},{"id":"15c15cb173976c7b","parameter":"Chromium (hexavalent)","value":"54**","value_num":54,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:18540-29-9","place":["US-NY"],"conditions":["receiving_water is marine","New York classes SA, SB, SC (saline waters; 6 NYCRR Part 701)"],"cite":{"instrument":"us_ny_wqs","title":"6 NYCRR 703.5 Table 1 water quality standards (as DEC TOGS 1.1.1 reprints them) and 703.3 pH, dissolved oxygen and dissolved solids (New York)","issuer":"State of New York, Department of Environmental Conservation","edition":"DEC Division of Water TOGS 1.1.1, reissued June 1998 (the 703.5 standards as revised effective March 12, 1998); 703.3 from 6 NYCRR Parts 700-706 as US EPA posts them in effect for CWA purposes (effective December 20, 2024)","source_url":"https://dec.ny.gov/docs/water_pdf/togs111.pdf","source_sha256":"090692f43a82280ffbf75751ecc52b94fc2d5c78996f9dc2483152343f8f4d59","fetched_at":"2026-10-10","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"6 NYCRR 703.5(f) Table 1","page":26,"quote":"Chromium (hexavalent) GA 50 H(WS) F (CAS No. Not Applicable) A, A-S, AA, AA-S, B, C 11* A(C) A, A-S, AA, AA-S, B, C, D 16* A(A) SA, SB, SC 54** A(C)"}},{"id":"41e74e5d3735e216","parameter":"Chromium (hexavalent)","value":"1,200**","value_num":1200,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:18540-29-9","place":["US-NY"],"conditions":["receiving_water is marine","New York classes SD (saline waters; 6 NYCRR Part 701)"],"cite":{"instrument":"us_ny_wqs","title":"6 NYCRR 703.5 Table 1 water quality standards (as DEC TOGS 1.1.1 reprints them) and 703.3 pH, dissolved oxygen and dissolved solids (New York)","issuer":"State of New York, Department of Environmental Conservation","edition":"DEC Division of Water TOGS 1.1.1, reissued June 1998 (the 703.5 standards as revised effective March 12, 1998); 703.3 from 6 NYCRR Parts 700-706 as US EPA posts them in effect for CWA purposes (effective December 20, 2024)","source_url":"https://dec.ny.gov/docs/water_pdf/togs111.pdf","source_sha256":"090692f43a82280ffbf75751ecc52b94fc2d5c78996f9dc2483152343f8f4d59","fetched_at":"2026-10-10","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"6 NYCRR 703.5(f) Table 1","page":26,"quote":"Chromium (hexavalent) GA 50 H(WS) F (CAS No. Not Applicable) A, A-S, AA, AA-S, B, C 11* A(C) A, A-S, AA, AA-S, B, C, D 16* A(A) SA, SB, SC 54** A(C) I 50** A(C) SD 1,200** A(A)"}},{"id":"586a491f98bacb89","parameter":"Hexavalent chromium","value":"0.25","value_num":0.25,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart L—Potassium Dichromate Production Subcategory","existing sources (PSES)","table: Subpart L—Potassium Dichromate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 415.124 (PSES)","page":null,"quote":"Hexavalent chromium 0.25 0.090"}},{"id":"80c65545de24faef","parameter":"Hexavalent chromium","value":"0.090","value_num":0.09,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart L—Potassium Dichromate Production Subcategory","existing sources (PSES)","table: Subpart L—Potassium Dichromate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 415.124 (PSES)","page":null,"quote":"Hexavalent chromium 0.25 0.090"}},{"id":"44301cb82638239a","parameter":"Hexavalent Chromium","value":"0.00090","value_num":0.0009,"unit":"Kg/kkg (or pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart Q—Sodium Dichromate and Sodium Sulfate Production Subcategory","existing sources (BPT)","table: Subpart Q—Sodium Dichromate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 415.172 (BPT)","page":null,"quote":"Hexavalent Chromium 0.00090 0.00050"}},{"id":"e684d0fc30e3fb2e","parameter":"Hexavalent Chromium","value":"0.00050","value_num":0.0005,"unit":"Kg/kkg (or pounds per 1,000 lb) of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart Q—Sodium Dichromate and Sodium Sulfate Production Subcategory","existing sources (BPT)","table: Subpart Q—Sodium Dichromate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 415.172 (BPT)","page":null,"quote":"Hexavalent Chromium 0.00090 0.00050"}},{"id":"e4dade62badb7d43","parameter":"Hexavalent Chromium","value":"0.11","value_num":0.11,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart Q—Sodium Dichromate and Sodium Sulfate Production Subcategory","new sources (PSNS)","table: Subpart Q—Sodium Dichromate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 415.176 (PSNS)","page":null,"quote":"Hexavalent Chromium 0.11 0.060"}},{"id":"3db527f50ed7c0c9","parameter":"Hexavalent Chromium","value":"0.060","value_num":0.06,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart Q—Sodium Dichromate and Sodium Sulfate Production Subcategory","new sources (PSNS)","table: Subpart Q—Sodium Dichromate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 415.176 (PSNS)","page":null,"quote":"Hexavalent Chromium 0.11 0.060"}},{"id":"ac5fe4fc7e451cb8","parameter":"Hexavalent Chromium","value":"0.25","value_num":0.25,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart AL—Ferric Chloride Production Subcategory","existing sources (PSES)","table: Subpart AL—Ferric Chloride"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 415.384 (PSES)","page":null,"quote":"Hexavalent Chromium 0.25 0.09"}},{"id":"bbc4a35bef16796d","parameter":"Hexavalent Chromium","value":"0.09","value_num":0.09,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart AL—Ferric Chloride Production Subcategory","existing sources (PSES)","table: Subpart AL—Ferric Chloride"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 415.384 (PSES)","page":null,"quote":"Hexavalent Chromium 0.25 0.09"}},{"id":"8e0092fd8ade30fc","parameter":"Hexavalent chromium","value":"0.028","value_num":0.028,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.12 (BPT)","page":null,"quote":"Hexavalent chromium 0.028 0.012"}},{"id":"5675ce4c2773c41c","parameter":"Hexavalent chromium","value":"0.012","value_num":0.012,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.12 (BPT)","page":null,"quote":"Hexavalent chromium 0.028 0.012"}},{"id":"a5c170365a595d95","parameter":"Hexavalent chromium","value":"0.062","value_num":0.062,"unit":"kilograms per 1,000 m³ of flow","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BPT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by th…"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.12 (BPT)","page":null,"quote":"Hexavalent chromium 0.062 0.028"}},{"id":"57a3d27a2709f0fb","parameter":"Hexavalent chromium","value":"0.028","value_num":0.028,"unit":"kilograms per 1,000 m³ of flow","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BPT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by th…"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.12 (BPT)","page":null,"quote":"Hexavalent chromium 0.062 0.028"}},{"id":"f7aa6927893b9926","parameter":"Hexavalent chromium","value":"0.0019","value_num":0.0019,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Crude"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Crude 0.0019 0.0009"}},{"id":"a0641b29156d1dcf","parameter":"Hexavalent chromium","value":"0.0009","value_num":0.0009,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Crude"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Crude 0.0019 0.0009"}},{"id":"cb746acdf3ee94fc","parameter":"Hexavalent chromium","value":"0.0218","value_num":0.0218,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Cracking and coking"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Cracking and coking 0.0218 0.0098"}},{"id":"1ddda5fac1059bee","parameter":"Hexavalent chromium","value":"0.0098","value_num":0.0098,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Cracking and coking"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Cracking and coking 0.0218 0.0098"}},{"id":"6861827fb0da18f1","parameter":"Hexavalent chromium","value":"0.0117","value_num":0.0117,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Asphalt"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Asphalt 0.0117 0.0053"}},{"id":"f831dc28ef48615f","parameter":"Hexavalent chromium","value":"0.0053","value_num":0.0053,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Asphalt"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Asphalt 0.0117 0.0053"}},{"id":"52d8f1f5a9e229bf","parameter":"Hexavalent chromium","value":"0.0549","value_num":0.0549,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Lube"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Lube 0.0549 0.0248"}},{"id":"b05e64665a23de5a","parameter":"Hexavalent chromium","value":"0.0248","value_num":0.0248,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Lube"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Lube 0.0549 0.0248"}},{"id":"0019d027dc08b268","parameter":"Hexavalent chromium","value":"0.0196","value_num":0.0196,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Reforming and alkylation"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Reforming and alkylation 0.0196 0.0088"}},{"id":"68fa7b81afc4c94c","parameter":"Hexavalent chromium","value":"0.0088","value_num":0.0088,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Reforming and alkylation"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Reforming and alkylation 0.0196 0.0088"}},{"id":"3a1f5e0f74cba875","parameter":"Hexavalent chromium","value":"0.062","value_num":0.062,"unit":"kilograms per 1,000 m³ of flow","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the permit writer times the …"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Hexavalent chromium 0.062 0.028"}},{"id":"16cc83d20ea9fd1e","parameter":"Hexavalent chromium","value":"0.028","value_num":0.028,"unit":"kilograms per 1,000 m³ of flow","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the permit writer times the …"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Hexavalent chromium 0.062 0.028"}},{"id":"f8ce2214c9c13e87","parameter":"Hexavalent chromium","value":"0.015","value_num":0.015,"unit":"kilograms per cubic meter of flow","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","new sources (NSPS)","(a) Any new source subject to this subpart must achieve the following new source performance standards (NSPS):"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.16 (NSPS)","page":null,"quote":"Hexavalent chromium 0.015 0.0068"}},{"id":"fe6afefbdfe84ab5","parameter":"Hexavalent chromium","value":"0.0068","value_num":0.0068,"unit":"kilograms per cubic meter of flow","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","new sources (NSPS)","(a) Any new source subject to this subpart must achieve the following new source performance standards (NSPS):"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.16 (NSPS)","page":null,"quote":"Hexavalent chromium 0.015 0.0068"}},{"id":"93f79981d38f7f8d","parameter":"Hexavalent chromium","value":"0.035","value_num":0.035,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.22 (BPT)","page":null,"quote":"Hexavalent chromium 0.035 0.016"}},{"id":"fecd421c87b4153a","parameter":"Hexavalent chromium","value":"0.016","value_num":0.016,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.22 (BPT)","page":null,"quote":"Hexavalent chromium 0.035 0.016"}},{"id":"ad4ccebfba672c86","parameter":"Hexavalent chromium","value":"0.062","value_num":0.062,"unit":"kilograms per 1,000 m³ of flow","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BPT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by th…"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.22 (BPT)","page":null,"quote":"Hexavalent chromium 0.062 0.028"}},{"id":"39eb6f7004a4d0da","parameter":"Hexavalent chromium","value":"0.028","value_num":0.028,"unit":"kilograms per 1,000 m³ of flow","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BPT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by th…"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.22 (BPT)","page":null,"quote":"Hexavalent chromium 0.062 0.028"}},{"id":"897bc7314a3e2fe1","parameter":"Hexavalent chromium","value":"0.0019","value_num":0.0019,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Crude"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.23 (BAT)","page":null,"quote":"Crude 0.0019 0.0009"}},{"id":"694830b8e0e244bc","parameter":"Hexavalent chromium","value":"0.0009","value_num":0.0009,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Crude"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.23 (BAT)","page":null,"quote":"Crude 0.0019 0.0009"}},{"id":"1e0569faa1c26e89","parameter":"Hexavalent chromium","value":"0.0218","value_num":0.0218,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Cracking and coking"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.23 (BAT)","page":null,"quote":"Cracking and coking 0.0218 0.0098"}},{"id":"7ae4474e993c1e76","parameter":"Hexavalent chromium","value":"0.0098","value_num":0.0098,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Cracking and coking"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.23 (BAT)","page":null,"quote":"Cracking and coking 0.0218 0.0098"}},{"id":"2413ddaf09abdc6e","parameter":"Hexavalent chromium","value":"0.0117","value_num":0.0117,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Asphalt"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.23 (BAT)","page":null,"quote":"Asphalt 0.0117 0.0053"}},{"id":"a2b9d06774470e48","parameter":"Hexavalent chromium","value":"0.0053","value_num":0.0053,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Asphalt"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.23 (BAT)","page":null,"quote":"Asphalt 0.0117 0.0053"}},{"id":"9589e823087d3b55","parameter":"Hexavalent chromium","value":"0.0549","value_num":0.0549,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Lube"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.23 (BAT)","page":null,"quote":"Lube 0.0549 0.0248"}},{"id":"c62579684af504e1","parameter":"Hexavalent chromium","value":"0.0248","value_num":0.0248,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Lube"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.23 (BAT)","page":null,"quote":"Lube 0.0549 0.0248"}},{"id":"4c88effa896d66e0","parameter":"Hexavalent chromium","value":"0.0196","value_num":0.0196,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Reforming and alkylation"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.23 (BAT)","page":null,"quote":"Reforming and alkylation 0.0196 0.0088"}},{"id":"37ef6dba2f9fc4c9","parameter":"Hexavalent chromium","value":"0.0088","value_num":0.0088,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Reforming and alkylation"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.23 (BAT)","page":null,"quote":"Reforming and alkylation 0.0196 0.0088"}},{"id":"8b6cc9cb3b195338","parameter":"Hexavalent chromium","value":"0.062","value_num":0.062,"unit":"kilograms per 1,000 m³ of flow","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BAT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the permit writer times the …"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.23 (BAT)","page":null,"quote":"Hexavalent chromium 0.062 0.028"}},{"id":"eeec884b37d0a408","parameter":"Hexavalent chromium","value":"0.028","value_num":0.028,"unit":"kilograms per 1,000 m³ of flow","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BAT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the permit writer times the …"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.23 (BAT)","page":null,"quote":"Hexavalent chromium 0.062 0.028"}},{"id":"2bdef93e4fa98984","parameter":"Hexavalent chromium","value":"0.020","value_num":0.02,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","new sources (NSPS)","(a) Any new source subject to this subpart must achieve the following new source performance standards (NSPS):"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.26 (NSPS)","page":null,"quote":"Hexavalent chromium 0.020 0.0088"}},{"id":"881275d31272d0f7","parameter":"Hexavalent chromium","value":"0.0088","value_num":0.0088,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","new sources (NSPS)","(a) Any new source subject to this subpart must achieve the following new source performance standards (NSPS):"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.26 (NSPS)","page":null,"quote":"Hexavalent chromium 0.020 0.0088"}},{"id":"927f186024de7f19","parameter":"Hexavalent chromium","value":"0.046","value_num":0.046,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart C—Petrochemical Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.32 (BPT)","page":null,"quote":"Hexavalent chromium 0.046 0.020"}},{"id":"47ba8ebf0df03275","parameter":"Hexavalent chromium","value":"0.020","value_num":0.02,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart C—Petrochemical Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 419.32 (BPT)","page":null,"quote":"Hexavalent chromium 0.046 0.020"}}],"next":[{"tool":"check_values","says":"Has your user measured this? check_values sets each of their results beside every row held here, with a verdict and the row's cite.","arguments":{"place":"US-NY"},"needs":{"rows":"Your user's measured results, as their table prints them: [{parameter: \"chromium vi\", value, unit}, ...], any other parameters too."},"post":"/api/v1/check"},{"tool":"read_certificate","says":"Has your user a laboratory certificate? read_certificate reads every row it prints, each with its page, and checks them against these limits.","arguments":{"place":"US-NY"},"needs":{"content_base64":"The laboratory's certificate (PDF) or its XLSX, XLS or CSV export, as base64; or file_url, a public https address of it."},"post":"/api/v1/certificate"}]}