{"query":{"parameter":"chloride","place":"US-TX","medium":null,"statistic":null,"kind":null},"searched":{"places":["US-TX","US"],"parameter_keys":["cas:16887-00-6","cas:7647-14-5"],"names_matched":[["chloride","cas:16887-00-6"],["chloride","cas:7647-14-5"]],"match":"exact","order":"The place's own instruments first, then each place above it, each in its register's order","not_searched":{"names":105,"parameters":64,"some":["1 1 3 5 tetramethyl piperidinium chloride","1 1 dichlorethane ethylidene chloride","1 1 dichloroethylene 1 1 dichloroethene vinylidene chloride","1 1 dichloroethylene vinylidene chloride","1 decanaminium n decyl n n dimethyl chloride","1 propanaminium 2 3 dihydroxy n n n trimethyl chloride","2 3 dihydroxy n n n trimethyl 1 propanaminium chloride","2 acryloyloxy ethyl trimethylammonium chloride","2 chlorobenzyl chloride","2 ethyl hexanoyl chloride","2 ethylhexyl chloride","2 propen 1 aminium n564n n dimethyl n propenyl chloride homopolymer","3 chloro 2 hydroxypropyltrimethyl ammonium chloride","3 chloro 2 hydroxypropyltrimethylammonium chloride","4 4 4 trifluoroacetoacetyl chloride","4 chlorobenzyl chloride","5 methylene chloride","acetyl chloride","alkyl dimethyl benzyl ammonium chloride","allyl chloride","aluminum chloride hydroxide","ammonium chloride","benzal chloride","benzoyl chloride","benzoyl chloride 2 methyl"],"says":"105 other names contain \"chloride\" (64 parameters, over the 40 searched at once): ask for one of them by name."}},"total":4,"offset":0,"returned":4,"next_offset":null,"rows":[{"id":"24c0fdb9910f5b58","parameter":"Chloride","value":"2.5E+02","value_num":250,"unit":"mg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:16887-00-6","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria."],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 3, Groundwater, Secondary MCL","page":40,"quote":null}},{"id":"b05b51d768cb5142","parameter":"Chloride","value":"860000","value_num":860000,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"national","parameter_key":"cas:16887-00-6","place":["US"],"conditions":["EPA's recommendation under Clean Water Act § 304(a): 'State and Tribal governments may use these criteria or use them as guidance in developing their own' — it binds a water once the state adopts it for the water's designated use","receiving_water is freshwater","Freshwater CMC (acute): criterion maximum concentration, acute"],"cite":{"instrument":"us_nrwqc_aquatic","title":"EPA National Recommended Water Quality Criteria — Aquatic Life Criteria Table (freshwater and saltwater CMC/CCC)","issuer":"U.S. Environmental Protection Agency","edition":"EPA web table, last updated on June 9, 2026 (fetched 2026-10-09); each criterion carries its publication year","source_url":"https://www.epa.gov/wqc/national-recommended-water-quality-criteria-aquatic-life-criteria-table","source_sha256":"be6b429558db9852c3456eb22c17046aa1a3335ee89e702e8afb793f9b5b25ec","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"National Recommended Aquatic Life Criteria table","page":null,"quote":"Chloride 16887006 860000 230000 — — 1988"}},{"id":"29842f23a80f2175","parameter":"Chloride","value":"230000","value_num":230000,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"national","parameter_key":"cas:16887-00-6","place":["US"],"conditions":["EPA's recommendation under Clean Water Act § 304(a): 'State and Tribal governments may use these criteria or use them as guidance in developing their own' — it binds a water once the state adopts it for the water's designated use","receiving_water is freshwater","Freshwater CCC (chronic): criterion continuous concentration, chronic"],"cite":{"instrument":"us_nrwqc_aquatic","title":"EPA National Recommended Water Quality Criteria — Aquatic Life Criteria Table (freshwater and saltwater CMC/CCC)","issuer":"U.S. Environmental Protection Agency","edition":"EPA web table, last updated on June 9, 2026 (fetched 2026-10-09); each criterion carries its publication year","source_url":"https://www.epa.gov/wqc/national-recommended-water-quality-criteria-aquatic-life-criteria-table","source_sha256":"be6b429558db9852c3456eb22c17046aa1a3335ee89e702e8afb793f9b5b25ec","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"National Recommended Aquatic Life Criteria table","page":null,"quote":"Chloride 16887006 860000 230000 — — 1988"}},{"id":"e89292cc53996141","parameter":"Chloride","value":"250 mg/l","value_num":250,"direction":"max","kind":"guideline","medium":"drinking_water","level":"national","parameter_key":"cas:16887-00-6","place":["US"],"conditions":["40 CFR 143.1: The regulations in this subpart are not Federally enforceable but are intended as guidelines for the States."],"cite":{"instrument":"us_nsdwr","title":"40 CFR Part 143 — National Secondary Drinking Water Regulations (eCFR, as of 2026-08-01)","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=143","source_sha256":"a98e8b66948f546c71e119055eff012e6380857a255ec216a4247b658bcf040d","fetched_at":"2026-08-29","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"143.3","page":null,"quote":null,"column":"smcl"}}],"next":[{"tool":"check_values","says":"Has your user measured this? check_values sets each of their results beside every row held here, with a verdict and the row's cite.","arguments":{"place":"US-TX"},"needs":{"rows":"Your user's measured results, as their table prints them: [{parameter: \"chloride\", value, unit}, ...], any other parameters too."},"post":"/api/v1/check"},{"tool":"read_certificate","says":"Has your user a laboratory certificate? read_certificate reads every row it prints, each with its page, and checks them against these limits.","arguments":{"place":"US-TX"},"needs":{"content_base64":"The laboratory's certificate (PDF) or its XLSX, XLS or CSV export, as base64; or file_url, a public https address of it."},"post":"/api/v1/certificate"}]}