{"query":{"parameter":"cadmium","place":"US-PA","medium":null,"statistic":null,"kind":null},"searched":{"places":["US-PA","US"],"parameter_keys":["cas:7440-43-9","name:arsenic, cadmium (h), copper (h), lead (h), mercury, zinc","name:arsenic, cadmium (h), copper (h), lead (h), zinc","name:cadmium (h), copper (h), mercury, lead (h), zinc","name:cadmium - total","name:cadmium, total","name:cadmium, total recoverable","name:total cadmium"],"names_matched":[["cadmium","cas:7440-43-9"],["arsenic cadmium h copper h lead h mercury zinc","name:arsenic, cadmium (h), copper (h), lead (h), mercury, zinc"],["arsenic cadmium h copper h lead h mercury zinc h","name:arsenic, cadmium (h), copper (h), lead (h), mercury, zinc"],["arsenic cadmium h copper h lead h zinc","name:arsenic, cadmium (h), copper (h), lead (h), zinc"],["arsenic cadmium h copper h lead h zinc h","name:arsenic, cadmium (h), copper (h), lead (h), zinc"],["cadmium h copper h mercury lead h zinc","name:cadmium (h), copper (h), mercury, lead (h), zinc"],["cadmium h copper h mercury lead h zinc h","name:cadmium (h), copper (h), mercury, lead (h), zinc"],["cadmium total","name:cadmium - total"],["cadmium total","name:cadmium, total"],["cadmium total recoverable","name:cadmium, total recoverable"],["total cadmium","name:cadmium - total"],["total cadmium","name:cadmium, total"],["total cadmium","name:total cadmium"],["total cadmium freshwater","name:total cadmium"],["total cadmium marine","name:total cadmium"],["total recoverable cadmium","name:cadmium, total recoverable"]],"match":"exact+contains","order":"The place's own instruments first, then each place above it, each in its register's order; rows for a marine receiving water after the rest, as none of the place's own rows names a marine, salt, estuarine, coastal or ocean water"},"total":636,"offset":0,"returned":50,"next_offset":50,"permits_over":{"state":"PA","parameter":"cadmium","permits":6,"list":"https://passage-data.com/api/v1/permits?state=PA&parameter=cadmium"},"rows":[{"id":"e4d51baea5797012","parameter":"CADMIUM","value":"5","value_num":5,"unit":"µg/L","direction":"max","kind":"guideline","medium":"groundwater","level":"regional","parameter_key":"cas:7440-43-9","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","groundwater in an aquifer used or currently planned to be used for drinking water or agriculture, total dissolved solids 2,500 mg/L or less (25 Pa. Code §250.304(c))","residential standard"],"cite":{"instrument":"us_pa_act2_gw","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for groundwater, Appendix A Tables 1-2, as DEP publishes them, with the 2024 PFAS MSCs","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 1 November 2021, Table 2 November 2023; the PFAS MSCs effective June 25, 2024 (DEP, updated 7/10/2024); DEP's bromobenzene correction as its Statewide Health Standards page states it on 2026-10-15","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%201.pdf","source_sha256":"5bc985b6f8b3595b0684a060dbc14d170987bbc89a70737370e1887c3932b13c","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 2 - Medium-Specific Concentrations (MSCs) for Inorganic Regulated Substances in Groundwater (used aquifer, TDS ≤ 2500, R)","page":1,"quote":null}},{"id":"aa1ba686b271677b","parameter":"CADMIUM","value":"5","value_num":5,"unit":"µg/L","direction":"max","kind":"guideline","medium":"groundwater","level":"regional","parameter_key":"cas:7440-43-9","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","groundwater in an aquifer used or currently planned to be used for drinking water or agriculture, total dissolved solids 2,500 mg/L or less (25 Pa. Code §250.304(c))","nonresidential standard"],"cite":{"instrument":"us_pa_act2_gw","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for groundwater, Appendix A Tables 1-2, as DEP publishes them, with the 2024 PFAS MSCs","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 1 November 2021, Table 2 November 2023; the PFAS MSCs effective June 25, 2024 (DEP, updated 7/10/2024); DEP's bromobenzene correction as its Statewide Health Standards page states it on 2026-10-15","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%201.pdf","source_sha256":"5bc985b6f8b3595b0684a060dbc14d170987bbc89a70737370e1887c3932b13c","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 2 - Medium-Specific Concentrations (MSCs) for Inorganic Regulated Substances in Groundwater (used aquifer, TDS ≤ 2500, NR)","page":1,"quote":null}},{"id":"8d6b36cecc0fd692","parameter":"CADMIUM","value":"500","value_num":500,"unit":"µg/L","direction":"max","kind":"guideline","medium":"groundwater","level":"regional","parameter_key":"cas:7440-43-9","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","groundwater in an aquifer used or currently planned to be used whose naturally occurring background total dissolved solids exceed 2,500 mg/L (§250.304(e))","residential standard"],"cite":{"instrument":"us_pa_act2_gw","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for groundwater, Appendix A Tables 1-2, as DEP publishes them, with the 2024 PFAS MSCs","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 1 November 2021, Table 2 November 2023; the PFAS MSCs effective June 25, 2024 (DEP, updated 7/10/2024); DEP's bromobenzene correction as its Statewide Health Standards page states it on 2026-10-15","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%201.pdf","source_sha256":"5bc985b6f8b3595b0684a060dbc14d170987bbc89a70737370e1887c3932b13c","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 2 - Medium-Specific Concentrations (MSCs) for Inorganic Regulated Substances in Groundwater (used aquifer, TDS > 2500, R)","page":1,"quote":null}},{"id":"3fb74ba0e8e46650","parameter":"CADMIUM","value":"500","value_num":500,"unit":"µg/L","direction":"max","kind":"guideline","medium":"groundwater","level":"regional","parameter_key":"cas:7440-43-9","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","groundwater in an aquifer used or currently planned to be used whose naturally occurring background total dissolved solids exceed 2,500 mg/L (§250.304(e))","nonresidential standard"],"cite":{"instrument":"us_pa_act2_gw","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for groundwater, Appendix A Tables 1-2, as DEP publishes them, with the 2024 PFAS MSCs","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 1 November 2021, Table 2 November 2023; the PFAS MSCs effective June 25, 2024 (DEP, updated 7/10/2024); DEP's bromobenzene correction as its Statewide Health Standards page states it on 2026-10-15","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%201.pdf","source_sha256":"5bc985b6f8b3595b0684a060dbc14d170987bbc89a70737370e1887c3932b13c","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 2 - Medium-Specific Concentrations (MSCs) for Inorganic Regulated Substances in Groundwater (used aquifer, TDS > 2500, NR)","page":1,"quote":null}},{"id":"314028e70bd3b710","parameter":"CADMIUM","value":"5000","value_num":5000,"unit":"µg/L","direction":"max","kind":"guideline","medium":"groundwater","level":"regional","parameter_key":"cas:7440-43-9","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","groundwater in an aquifer not used or currently planned to be used (§250.304(d))","residential standard"],"cite":{"instrument":"us_pa_act2_gw","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for groundwater, Appendix A Tables 1-2, as DEP publishes them, with the 2024 PFAS MSCs","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 1 November 2021, Table 2 November 2023; the PFAS MSCs effective June 25, 2024 (DEP, updated 7/10/2024); DEP's bromobenzene correction as its Statewide Health Standards page states it on 2026-10-15","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%201.pdf","source_sha256":"5bc985b6f8b3595b0684a060dbc14d170987bbc89a70737370e1887c3932b13c","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 2 - Medium-Specific Concentrations (MSCs) for Inorganic Regulated Substances in Groundwater (nonuse aquifer, R)","page":1,"quote":null}},{"id":"43a5040d2ce0a9df","parameter":"CADMIUM","value":"5000","value_num":5000,"unit":"µg/L","direction":"max","kind":"guideline","medium":"groundwater","level":"regional","parameter_key":"cas:7440-43-9","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","groundwater in an aquifer not used or currently planned to be used (§250.304(d))","nonresidential standard"],"cite":{"instrument":"us_pa_act2_gw","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for groundwater, Appendix A Tables 1-2, as DEP publishes them, with the 2024 PFAS MSCs","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 1 November 2021, Table 2 November 2023; the PFAS MSCs effective June 25, 2024 (DEP, updated 7/10/2024); DEP's bromobenzene correction as its Statewide Health Standards page states it on 2026-10-15","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%201.pdf","source_sha256":"5bc985b6f8b3595b0684a060dbc14d170987bbc89a70737370e1887c3932b13c","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 2 - Medium-Specific Concentrations (MSCs) for Inorganic Regulated Substances in Groundwater (nonuse aquifer, NR)","page":1,"quote":null}},{"id":"c94dd1f03741c0db","parameter":"CADMIUM","value":"110","value_num":110,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:7440-43-9","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a direct contact numeric value: the soil MSC is the lowest of it and the soil-to-groundwater numeric value, or it with a soil buffer or equivalency demonstration (§250.305(c)-(e))","residential, soil 0-15 feet from the existing ground surface (§250.305(c))"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, A. Direct Contact Numeric Values (R)","page":1,"quote":null}},{"id":"0b9296784966ce46","parameter":"CADMIUM","value":"1600","value_num":1600,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:7440-43-9","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a direct contact numeric value: the soil MSC is the lowest of it and the soil-to-groundwater numeric value, or it with a soil buffer or equivalency demonstration (§250.305(c)-(e))","nonresidential, surface soil 0-2 feet (§250.305(d))"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, A. Direct Contact Numeric Values (NR 0-2 ft)","page":1,"quote":null}},{"id":"468d60ecf222bdb6","parameter":"CADMIUM","value":"190000","value_num":190000,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:7440-43-9","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a direct contact numeric value: the soil MSC is the lowest of it and the soil-to-groundwater numeric value, or it with a soil buffer or equivalency demonstration (§250.305(c)-(e))","nonresidential, subsurface soil 2-15 feet (§250.305(e))"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, A. Direct Contact Numeric Values (NR 2-15 ft)","page":1,"quote":null}},{"id":"6df84a34bdc8333a","parameter":"CADMIUM","value":"0.5","value_num":0.5,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:7440-43-9","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))","the option 100 times the applicable groundwater MSC, expressed as mg/kg (§250.308(a)(1))","groundwater in an aquifer used or currently planned to be used for drinking water or agriculture, total dissolved solids 2,500 mg/L or less (25 Pa. Code §250.304(c))","residential standard"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (used aquifer, TDS ≤ 2500, R, 100 X GW MSC)","page":1,"quote":null}},{"id":"78c413bd9432e185","parameter":"CADMIUM","value":"38","value_num":38,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:7440-43-9","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))","the generic value of the soil-to-groundwater equation, for soil not in the zone of groundwater saturation; in that zone the value is one tenth of it (§250.308(a)(2)-(4))","groundwater in an aquifer used or currently planned to be used for drinking water or agriculture, total dissolved solids 2,500 mg/L or less (25 Pa. Code §250.304(c))","residential standard"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (used aquifer, TDS ≤ 2500, R, Generic Value)","page":1,"quote":null}},{"id":"2dfd5ef1801a4c96","parameter":"CADMIUM","value":"0.5","value_num":0.5,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:7440-43-9","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))","the option 100 times the applicable groundwater MSC, expressed as mg/kg (§250.308(a)(1))","groundwater in an aquifer used or currently planned to be used for drinking water or agriculture, total dissolved solids 2,500 mg/L or less (25 Pa. Code §250.304(c))","nonresidential standard"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (used aquifer, TDS ≤ 2500, NR, 100 X GW MSC)","page":1,"quote":null}},{"id":"6ec0661aded67ece","parameter":"CADMIUM","value":"38","value_num":38,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:7440-43-9","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))","the generic value of the soil-to-groundwater equation, for soil not in the zone of groundwater saturation; in that zone the value is one tenth of it (§250.308(a)(2)-(4))","groundwater in an aquifer used or currently planned to be used for drinking water or agriculture, total dissolved solids 2,500 mg/L or less (25 Pa. Code §250.304(c))","nonresidential standard"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (used aquifer, TDS ≤ 2500, NR, Generic Value)","page":1,"quote":null}},{"id":"e199ed6e194a232b","parameter":"CADMIUM","value":"50","value_num":50,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:7440-43-9","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))","the option 100 times the applicable groundwater MSC, expressed as mg/kg (§250.308(a)(1))","groundwater in an aquifer used or currently planned to be used whose naturally occurring background total dissolved solids exceed 2,500 mg/L (§250.304(e))","residential standard"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (used aquifer, TDS > 2500, R, 100 X GW MSC)","page":1,"quote":null}},{"id":"7f4afc4ed14ec926","parameter":"CADMIUM","value":"3800","value_num":3800,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:7440-43-9","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))","the generic value of the soil-to-groundwater equation, for soil not in the zone of groundwater saturation; in that zone the value is one tenth of it (§250.308(a)(2)-(4))","groundwater in an aquifer used or currently planned to be used whose naturally occurring background total dissolved solids exceed 2,500 mg/L (§250.304(e))","residential standard"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (used aquifer, TDS > 2500, R, Generic Value)","page":1,"quote":null}},{"id":"048a8584f9bc2f6c","parameter":"CADMIUM","value":"50","value_num":50,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:7440-43-9","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))","the option 100 times the applicable groundwater MSC, expressed as mg/kg (§250.308(a)(1))","groundwater in an aquifer used or currently planned to be used whose naturally occurring background total dissolved solids exceed 2,500 mg/L (§250.304(e))","nonresidential standard"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (used aquifer, TDS > 2500, NR, 100 X GW MSC)","page":1,"quote":null}},{"id":"ff15c0f9faaab1f5","parameter":"CADMIUM","value":"3800","value_num":3800,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:7440-43-9","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))","the generic value of the soil-to-groundwater equation, for soil not in the zone of groundwater saturation; in that zone the value is one tenth of it (§250.308(a)(2)-(4))","groundwater in an aquifer used or currently planned to be used whose naturally occurring background total dissolved solids exceed 2,500 mg/L (§250.304(e))","nonresidential standard"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (used aquifer, TDS > 2500, NR, Generic Value)","page":1,"quote":null}},{"id":"911dd7bd773b240d","parameter":"CADMIUM","value":"500","value_num":500,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:7440-43-9","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))","the option 100 times the applicable groundwater MSC, expressed as mg/kg (§250.308(a)(1))","groundwater in an aquifer not used or currently planned to be used (§250.304(d))","residential standard"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (nonuse aquifer, R, 100 X GW MSC)","page":1,"quote":null}},{"id":"db801149aee4ffa3","parameter":"CADMIUM","value":"38000","value_num":38000,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:7440-43-9","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))","the generic value of the soil-to-groundwater equation, for soil not in the zone of groundwater saturation; in that zone the value is one tenth of it (§250.308(a)(2)-(4))","groundwater in an aquifer not used or currently planned to be used (§250.304(d))","residential standard"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (nonuse aquifer, R, Generic Value)","page":1,"quote":null}},{"id":"2f2c36600722f07f","parameter":"CADMIUM","value":"500","value_num":500,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:7440-43-9","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))","the option 100 times the applicable groundwater MSC, expressed as mg/kg (§250.308(a)(1))","groundwater in an aquifer not used or currently planned to be used (§250.304(d))","nonresidential standard"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (nonuse aquifer, NR, 100 X GW MSC)","page":1,"quote":null}},{"id":"303bbed607cb3a0b","parameter":"CADMIUM","value":"38000","value_num":38000,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:7440-43-9","place":["US-PA"],"conditions":["the Statewide health standard under Act 2 (Land Recycling and Environmental Remediation Standards Act): a person may instead attain the background or a site-specific standard","a soil-to-groundwater numeric value (§250.308(a)): a person may instead show the soil's SPLP leachate does not exceed the groundwater MSC, or use the soil buffer distance (§250.308(b)) or an equivalency demonstration (§250.308(d)); soil below 15 feet takes only this pathway (§250.305(f))","the generic value of the soil-to-groundwater equation, for soil not in the zone of groundwater saturation; in that zone the value is one tenth of it (§250.308(a)(2)-(4))","groundwater in an aquifer not used or currently planned to be used (§250.304(d))","nonresidential standard"],"cite":{"instrument":"us_pa_act2_soil","title":"25 Pa. Code ch. 250 (Act 2) — Statewide health standard MSCs for soil, Appendix A Tables 3-4 (direct contact and soil to groundwater), as DEP publishes them","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection, Land Recycling Program)","edition":"the Appendix A tables in force from November 20, 2021 (51 Pa.B. 7173) as DEP publishes them: Table 3A November 2021, Table 3B January 2022, Tables 4A and 4B November 2023","source_url":"https://files.dep.state.pa.us/EnvironmentalCleanupBrownfields/LandRecyclingProgram/LandRecyclingProgramPortalFiles/GuidanceTechTools/VaporIntrusion/November_2021/Table%203a.pdf","source_sha256":"546e6e1ac858eb7cccc6d8f5a029fa8a9a4f7976e589cf983ef8f359b491dfb7","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"25 Pa. Code ch. 250 Appendix A, Table 4 - MSCs for Inorganic Regulated Substances in Soil, B. Soil to Groundwater Numeric Values (nonuse aquifer, NR, Generic Value)","page":1,"quote":null}},{"id":"40a076564e9893cf","parameter":"CADMIUM","value":"{1.101672-(ln[H]x0.041838)}x Exp(0.7977xln[H]-3.909)","unit":"µg/L","statistic":"four_day_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-43-9","place":["US-PA"],"conditions":[],"cite":{"instrument":"us_pa_wqs","title":"25 Pa. Code §93.8c Table 5 (water quality criteria for toxic substances) and §93.7 Table 3 (specific water quality criteria) — Pennsylvania","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection)","edition":"Pennsylvania Code as served 2026-10-09: §93.8c amended December 19, 2025, effective December 20, 2025, 55 Pa.B. 8596; §93.7 rows name their own page","source_url":"https://www.pacodeandbulletin.gov/Display/pacode?file=/secure/pacode/data/025/chapter93/s93.8c.html","source_sha256":"9f8f9a0d4da400c55be6373f6a6482b24c4fab5c9a4d0c445f3f55c33a799beb","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"changed","changed_on":"2026-11-03","says":"Source changed on or before 2026-11-03, not yet re-read: these rows are as read from Pennsylvania Code as served 2026-10-09: §93.8c amended December 19, 2025, effective December 20, 2025, 55 Pa.B. 8596; §93.7 rows name their own page."},"section":"25 Pa. Code §93.8c Table 5 (criteria continuous concentration (CCC))","page":null,"quote":"4M CADMIUM 7440439 {1.101672-(ln[H]x0.041838)}x {1.136672-(ln[H]x0.041838)}x N/A 3 Exp(0.7977xln[H]-3.909) Exp(0.9789xln[H]-3.866) (ex: @H=100, CCC=0.72) (ex: @H=100, CMC=1.8) (ex: @H=50, CCC=0.43) (ex: @H=50, CMC=0.94) (ex: @H=25, CCC=0.25) (ex: @H=25, CMC=0.49)"}},{"id":"c43d8401bc308619","parameter":"CADMIUM","value":"(ex: @H=100, CCC=0.72)","value_num":0.72,"unit":"µg/L","statistic":"four_day_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-43-9","place":["US-PA"],"conditions":["hardness 100 mg/L as CaCO3: the table's printed example of the equation {1.101672-(ln[H]x0.041838)}x Exp(0.7977xln[H]-3.909)"],"cite":{"instrument":"us_pa_wqs","title":"25 Pa. Code §93.8c Table 5 (water quality criteria for toxic substances) and §93.7 Table 3 (specific water quality criteria) — Pennsylvania","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection)","edition":"Pennsylvania Code as served 2026-10-09: §93.8c amended December 19, 2025, effective December 20, 2025, 55 Pa.B. 8596; §93.7 rows name their own page","source_url":"https://www.pacodeandbulletin.gov/Display/pacode?file=/secure/pacode/data/025/chapter93/s93.8c.html","source_sha256":"9f8f9a0d4da400c55be6373f6a6482b24c4fab5c9a4d0c445f3f55c33a799beb","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"changed","changed_on":"2026-11-03","says":"Source changed on or before 2026-11-03, not yet re-read: these rows are as read from Pennsylvania Code as served 2026-10-09: §93.8c amended December 19, 2025, effective December 20, 2025, 55 Pa.B. 8596; §93.7 rows name their own page."},"section":"25 Pa. Code §93.8c Table 5 (criteria continuous concentration (CCC)), printed example","page":null,"quote":"4M CADMIUM 7440439 {1.101672-(ln[H]x0.041838)}x {1.136672-(ln[H]x0.041838)}x N/A 3 Exp(0.7977xln[H]-3.909) Exp(0.9789xln[H]-3.866) (ex: @H=100, CCC=0.72) (ex: @H=100, CMC=1.8) (ex: @H=50, CCC=0.43) (ex: @H=50, CMC=0.94) (ex: @H=25, CCC=0.25) (ex: @H=25, CMC=0.49)"}},{"id":"98fc216be8fd88ae","parameter":"CADMIUM","value":"(ex: @H=50, CCC=0.43)","value_num":0.43,"unit":"µg/L","statistic":"four_day_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-43-9","place":["US-PA"],"conditions":["hardness 50 mg/L as CaCO3: the table's printed example of the equation {1.101672-(ln[H]x0.041838)}x Exp(0.7977xln[H]-3.909)"],"cite":{"instrument":"us_pa_wqs","title":"25 Pa. Code §93.8c Table 5 (water quality criteria for toxic substances) and §93.7 Table 3 (specific water quality criteria) — Pennsylvania","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection)","edition":"Pennsylvania Code as served 2026-10-09: §93.8c amended December 19, 2025, effective December 20, 2025, 55 Pa.B. 8596; §93.7 rows name their own page","source_url":"https://www.pacodeandbulletin.gov/Display/pacode?file=/secure/pacode/data/025/chapter93/s93.8c.html","source_sha256":"9f8f9a0d4da400c55be6373f6a6482b24c4fab5c9a4d0c445f3f55c33a799beb","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"changed","changed_on":"2026-11-03","says":"Source changed on or before 2026-11-03, not yet re-read: these rows are as read from Pennsylvania Code as served 2026-10-09: §93.8c amended December 19, 2025, effective December 20, 2025, 55 Pa.B. 8596; §93.7 rows name their own page."},"section":"25 Pa. Code §93.8c Table 5 (criteria continuous concentration (CCC)), printed example","page":null,"quote":"4M CADMIUM 7440439 {1.101672-(ln[H]x0.041838)}x {1.136672-(ln[H]x0.041838)}x N/A 3 Exp(0.7977xln[H]-3.909) Exp(0.9789xln[H]-3.866) (ex: @H=100, CCC=0.72) (ex: @H=100, CMC=1.8) (ex: @H=50, CCC=0.43) (ex: @H=50, CMC=0.94) (ex: @H=25, CCC=0.25) (ex: @H=25, CMC=0.49)"}},{"id":"9403eb8b73afd118","parameter":"CADMIUM","value":"(ex: @H=25, CCC=0.25)","value_num":0.25,"unit":"µg/L","statistic":"four_day_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-43-9","place":["US-PA"],"conditions":["hardness 25 mg/L as CaCO3: the table's printed example of the equation {1.101672-(ln[H]x0.041838)}x Exp(0.7977xln[H]-3.909)"],"cite":{"instrument":"us_pa_wqs","title":"25 Pa. Code §93.8c Table 5 (water quality criteria for toxic substances) and §93.7 Table 3 (specific water quality criteria) — Pennsylvania","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection)","edition":"Pennsylvania Code as served 2026-10-09: §93.8c amended December 19, 2025, effective December 20, 2025, 55 Pa.B. 8596; §93.7 rows name their own page","source_url":"https://www.pacodeandbulletin.gov/Display/pacode?file=/secure/pacode/data/025/chapter93/s93.8c.html","source_sha256":"9f8f9a0d4da400c55be6373f6a6482b24c4fab5c9a4d0c445f3f55c33a799beb","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"changed","changed_on":"2026-11-03","says":"Source changed on or before 2026-11-03, not yet re-read: these rows are as read from Pennsylvania Code as served 2026-10-09: §93.8c amended December 19, 2025, effective December 20, 2025, 55 Pa.B. 8596; §93.7 rows name their own page."},"section":"25 Pa. Code §93.8c Table 5 (criteria continuous concentration (CCC)), printed example","page":null,"quote":"4M CADMIUM 7440439 {1.101672-(ln[H]x0.041838)}x {1.136672-(ln[H]x0.041838)}x N/A 3 Exp(0.7977xln[H]-3.909) Exp(0.9789xln[H]-3.866) (ex: @H=100, CCC=0.72) (ex: @H=100, CMC=1.8) (ex: @H=50, CCC=0.43) (ex: @H=50, CMC=0.94) (ex: @H=25, CCC=0.25) (ex: @H=25, CMC=0.49)"}},{"id":"8bd9c400ac67b246","parameter":"CADMIUM","value":"{1.136672-(ln[H]x0.041838)}x Exp(0.9789xln[H]-3.866)","unit":"µg/L","statistic":"hourly_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-43-9","place":["US-PA"],"conditions":[],"cite":{"instrument":"us_pa_wqs","title":"25 Pa. Code §93.8c Table 5 (water quality criteria for toxic substances) and §93.7 Table 3 (specific water quality criteria) — Pennsylvania","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection)","edition":"Pennsylvania Code as served 2026-10-09: §93.8c amended December 19, 2025, effective December 20, 2025, 55 Pa.B. 8596; §93.7 rows name their own page","source_url":"https://www.pacodeandbulletin.gov/Display/pacode?file=/secure/pacode/data/025/chapter93/s93.8c.html","source_sha256":"9f8f9a0d4da400c55be6373f6a6482b24c4fab5c9a4d0c445f3f55c33a799beb","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"changed","changed_on":"2026-11-03","says":"Source changed on or before 2026-11-03, not yet re-read: these rows are as read from Pennsylvania Code as served 2026-10-09: §93.8c amended December 19, 2025, effective December 20, 2025, 55 Pa.B. 8596; §93.7 rows name their own page."},"section":"25 Pa. Code §93.8c Table 5 (criteria maximum concentration (CMC))","page":null,"quote":"4M CADMIUM 7440439 {1.101672-(ln[H]x0.041838)}x {1.136672-(ln[H]x0.041838)}x N/A 3 Exp(0.7977xln[H]-3.909) Exp(0.9789xln[H]-3.866) (ex: @H=100, CCC=0.72) (ex: @H=100, CMC=1.8) (ex: @H=50, CCC=0.43) (ex: @H=50, CMC=0.94) (ex: @H=25, CCC=0.25) (ex: @H=25, CMC=0.49)"}},{"id":"2d1e912085d23330","parameter":"CADMIUM","value":"(ex: @H=100, CMC=1.8)","value_num":1.8,"unit":"µg/L","statistic":"hourly_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-43-9","place":["US-PA"],"conditions":["hardness 100 mg/L as CaCO3: the table's printed example of the equation {1.136672-(ln[H]x0.041838)}x Exp(0.9789xln[H]-3.866)"],"cite":{"instrument":"us_pa_wqs","title":"25 Pa. Code §93.8c Table 5 (water quality criteria for toxic substances) and §93.7 Table 3 (specific water quality criteria) — Pennsylvania","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection)","edition":"Pennsylvania Code as served 2026-10-09: §93.8c amended December 19, 2025, effective December 20, 2025, 55 Pa.B. 8596; §93.7 rows name their own page","source_url":"https://www.pacodeandbulletin.gov/Display/pacode?file=/secure/pacode/data/025/chapter93/s93.8c.html","source_sha256":"9f8f9a0d4da400c55be6373f6a6482b24c4fab5c9a4d0c445f3f55c33a799beb","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"changed","changed_on":"2026-11-03","says":"Source changed on or before 2026-11-03, not yet re-read: these rows are as read from Pennsylvania Code as served 2026-10-09: §93.8c amended December 19, 2025, effective December 20, 2025, 55 Pa.B. 8596; §93.7 rows name their own page."},"section":"25 Pa. Code §93.8c Table 5 (criteria maximum concentration (CMC)), printed example","page":null,"quote":"4M CADMIUM 7440439 {1.101672-(ln[H]x0.041838)}x {1.136672-(ln[H]x0.041838)}x N/A 3 Exp(0.7977xln[H]-3.909) Exp(0.9789xln[H]-3.866) (ex: @H=100, CCC=0.72) (ex: @H=100, CMC=1.8) (ex: @H=50, CCC=0.43) (ex: @H=50, CMC=0.94) (ex: @H=25, CCC=0.25) (ex: @H=25, CMC=0.49)"}},{"id":"4540d8f7a329688f","parameter":"CADMIUM","value":"(ex: @H=50, CMC=0.94)","value_num":0.94,"unit":"µg/L","statistic":"hourly_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-43-9","place":["US-PA"],"conditions":["hardness 50 mg/L as CaCO3: the table's printed example of the equation {1.136672-(ln[H]x0.041838)}x Exp(0.9789xln[H]-3.866)"],"cite":{"instrument":"us_pa_wqs","title":"25 Pa. Code §93.8c Table 5 (water quality criteria for toxic substances) and §93.7 Table 3 (specific water quality criteria) — Pennsylvania","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection)","edition":"Pennsylvania Code as served 2026-10-09: §93.8c amended December 19, 2025, effective December 20, 2025, 55 Pa.B. 8596; §93.7 rows name their own page","source_url":"https://www.pacodeandbulletin.gov/Display/pacode?file=/secure/pacode/data/025/chapter93/s93.8c.html","source_sha256":"9f8f9a0d4da400c55be6373f6a6482b24c4fab5c9a4d0c445f3f55c33a799beb","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"changed","changed_on":"2026-11-03","says":"Source changed on or before 2026-11-03, not yet re-read: these rows are as read from Pennsylvania Code as served 2026-10-09: §93.8c amended December 19, 2025, effective December 20, 2025, 55 Pa.B. 8596; §93.7 rows name their own page."},"section":"25 Pa. Code §93.8c Table 5 (criteria maximum concentration (CMC)), printed example","page":null,"quote":"4M CADMIUM 7440439 {1.101672-(ln[H]x0.041838)}x {1.136672-(ln[H]x0.041838)}x N/A 3 Exp(0.7977xln[H]-3.909) Exp(0.9789xln[H]-3.866) (ex: @H=100, CCC=0.72) (ex: @H=100, CMC=1.8) (ex: @H=50, CCC=0.43) (ex: @H=50, CMC=0.94) (ex: @H=25, CCC=0.25) (ex: @H=25, CMC=0.49)"}},{"id":"60fa86f938a7c0ab","parameter":"CADMIUM","value":"(ex: @H=25, CMC=0.49)","value_num":0.49,"unit":"µg/L","statistic":"hourly_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-43-9","place":["US-PA"],"conditions":["hardness 25 mg/L as CaCO3: the table's printed example of the equation {1.136672-(ln[H]x0.041838)}x Exp(0.9789xln[H]-3.866)"],"cite":{"instrument":"us_pa_wqs","title":"25 Pa. Code §93.8c Table 5 (water quality criteria for toxic substances) and §93.7 Table 3 (specific water quality criteria) — Pennsylvania","issuer":"Commonwealth of Pennsylvania, Environmental Quality Board (Department of Environmental Protection)","edition":"Pennsylvania Code as served 2026-10-09: §93.8c amended December 19, 2025, effective December 20, 2025, 55 Pa.B. 8596; §93.7 rows name their own page","source_url":"https://www.pacodeandbulletin.gov/Display/pacode?file=/secure/pacode/data/025/chapter93/s93.8c.html","source_sha256":"9f8f9a0d4da400c55be6373f6a6482b24c4fab5c9a4d0c445f3f55c33a799beb","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"changed","changed_on":"2026-11-03","says":"Source changed on or before 2026-11-03, not yet re-read: these rows are as read from Pennsylvania Code as served 2026-10-09: §93.8c amended December 19, 2025, effective December 20, 2025, 55 Pa.B. 8596; §93.7 rows name their own page."},"section":"25 Pa. Code §93.8c Table 5 (criteria maximum concentration (CMC)), printed example","page":null,"quote":"4M CADMIUM 7440439 {1.101672-(ln[H]x0.041838)}x {1.136672-(ln[H]x0.041838)}x N/A 3 Exp(0.7977xln[H]-3.909) Exp(0.9789xln[H]-3.866) (ex: @H=100, CCC=0.72) (ex: @H=100, CMC=1.8) (ex: @H=50, CCC=0.43) (ex: @H=50, CMC=0.94) (ex: @H=25, CCC=0.25) (ex: @H=25, CMC=0.49)"}},{"id":"438d9461762b0a96","parameter":"Cadmium","value":"1.0","value_num":1,"unit":"mg/L","direction":"max","kind":"threshold","medium":"leachate","level":"national","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["(a) A solid waste (except manufactured gas plant waste) exhibits the characteristic of toxicity if, using the Toxicity Characteristic Leaching Procedure, test Method 1311 in “Test Methods for Evaluating Solid Waste, Physical/Chemical Methods,” EPA Publication SW-846, as incorporated by reference in § 260.11 of this chapter, the extract from a representative sample of the waste contains any of the contaminants listed in table 1 at the concentration equal to or greater than the respective value given in that table. Where the waste contains less than 0.5 percent filterable solids, the waste itself, after filtering using the methodology outlined in Method 1311, is considered to be the extract for the purpose of this section."],"cite":{"instrument":"us_40cfr261_24","title":"40 CFR 261.24 — Toxicity characteristic: Table 1, maximum concentration of contaminants for the toxicity characteristic (TCLP regulatory levels)","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"eCFR, 40 CFR 261.24 as of 2026-10-13 (title 40 up to date as of that day)","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-13/title-40.xml?part=261&section=261.24","source_sha256":"3a1ec9b0d3051c70e471e359275657b0fa6d98e80927d2217e82b2dbbca60961","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 261.24, Table 1","page":null,"quote":"D006 Cadmium 7440-43-9 1.0"}},{"id":"61943f113fbd68f0","parameter":"Cadmium","value":"0.69","value_num":0.69,"unit":"mg/L","statistic":"composite","direction":"max","kind":"limit","medium":"product","level":"national","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["(a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS."],"cite":{"instrument":"us_40cfr268_48","title":"40 CFR 268.48 — Universal treatment standards: Table UTS, wastewater and nonwastewater treatment standards for the hazardous constituents of land-disposal-restricted wastes","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"eCFR, 40 CFR 268.48 as of 2026-10-13 (title 40 up to date as of that day; source note: 59 FR 48103, Sept. 19, 1994, as last amended at 76 FR 34156, June 13, 2011)","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-13/title-40.xml?part=268&section=268.48","source_sha256":"70b2e58a6b1e228e2c204acc69b69fab0d5a0347e35d569959073c3dc3ee4adb","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 268.48, Table UTS, Inorganic Constituents, wastewater standard","page":null,"quote":"Cadmium 7440-43-9 0.69 0.11 mg/l TCLP"}},{"id":"dc91caad3b27226c","parameter":"Cadmium","value":"0.11 mg/l TCLP","value_num":0.11,"unit":"mg/L TCLP","statistic":"instant","direction":"max","kind":"limit","medium":"leachate","level":"national","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["(a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS."],"cite":{"instrument":"us_40cfr268_48","title":"40 CFR 268.48 — Universal treatment standards: Table UTS, wastewater and nonwastewater treatment standards for the hazardous constituents of land-disposal-restricted wastes","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"eCFR, 40 CFR 268.48 as of 2026-10-13 (title 40 up to date as of that day; source note: 59 FR 48103, Sept. 19, 1994, as last amended at 76 FR 34156, June 13, 2011)","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-13/title-40.xml?part=268&section=268.48","source_sha256":"70b2e58a6b1e228e2c204acc69b69fab0d5a0347e35d569959073c3dc3ee4adb","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 268.48, Table UTS, Inorganic Constituents, nonwastewater standard","page":null,"quote":"Cadmium 7440-43-9 0.69 0.11 mg/l TCLP"}},{"id":"f4fed814193e1e0d","parameter":"Cd","value":"1.2","value_num":1.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(b) For a source discharging less than 38,000 liters (10,000 gal.) per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart A—Common Metals Facilities Discharging Less Than 38,000 Liters Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Cd 1.2 .7"}},{"id":"dee7a50742a8188b","parameter":"Cd","value":".7","value_num":0.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(b) For a source discharging less than 38,000 liters (10,000 gal.) per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart A—Common Metals Facilities Discharging Less Than 38,000 Liters Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Cd 1.2 .7"}},{"id":"5dd56369591c22c3","parameter":"Cd","value":"1.2","value_num":1.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Cd 1.2 .7"}},{"id":"073ba142673baa6d","parameter":"Cd","value":".7","value_num":0.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Cd 1.2 .7"}},{"id":"53361efaf292ff21","parameter":"Cd","value":"47","value_num":47,"unit":"mg/sq m-Operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may be applied in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Cd 47 29"}},{"id":"262cb4ac49375d1d","parameter":"Cd","value":"29","value_num":29,"unit":"mg/sq m-Operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may be applied in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Cd 47 29"}},{"id":"89c54d05777874ae","parameter":"Cd","value":"1.2","value_num":1.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(e) For wastewater sources regulated under paragraph (c) of this section, the following optional control program may be elected by the source introducing treated process wastewater into a publicly owned treatment works with the concurrence of the control authority. These optional pollutant parameters are not eligible for allowance for removal achieved by the publicly owned treatment works under…","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Cd 1.2 .7"}},{"id":"c2ea7b79f28c3609","parameter":"Cd","value":".7","value_num":0.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(e) For wastewater sources regulated under paragraph (c) of this section, the following optional control program may be elected by the source introducing treated process wastewater into a publicly owned treatment works with the concurrence of the control authority. These optional pollutant parameters are not eligible for allowance for removal achieved by the publicly owned treatment works under…","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Cd 1.2 .7"}},{"id":"1fe2453da17667fa","parameter":"Cd","value":"1.2","value_num":1.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(b) For a source discharging less than 38,000 liters (10,000 gal) per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart B—Precious Metals Facilities Discharging Less Than 38,000 Liters Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Cd 1.2 .7"}},{"id":"8606c2ae6d5b68cd","parameter":"Cd","value":".7","value_num":0.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(b) For a source discharging less than 38,000 liters (10,000 gal) per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart B—Precious Metals Facilities Discharging Less Than 38,000 Liters Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Cd 1.2 .7"}},{"id":"0261da17b29b318e","parameter":"Cd","value":"1.2","value_num":1.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Cd 1.2 .7"}},{"id":"8ee7c192aae25f17","parameter":"Cd","value":".7","value_num":0.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Cd 1.2 .7"}},{"id":"63248eed8a79bee1","parameter":"Cd","value":"47","value_num":47,"unit":"mg/sq m-Operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Cd 47 29"}},{"id":"5447ac0e86953e1d","parameter":"Cd","value":"29","value_num":29,"unit":"mg/sq m-Operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Cd 47 29"}},{"id":"7f441ed38844c3a8","parameter":"Cd","value":"1.2","value_num":1.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(e) For wastewater sources regulated under paragraph (c) of this section, the following optional control program may be elected by the source introducing treated process wastewater into a publicly owned treatment works with the concurrence of the control authority. These optional pollutant parameters are not eligible for allowance for removal achieved by the publicly owned treatment works under…","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Cd 1.2 .7"}},{"id":"7aed455af7bc3890","parameter":"Cd","value":".7","value_num":0.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(e) For wastewater sources regulated under paragraph (c) of this section, the following optional control program may be elected by the source introducing treated process wastewater into a publicly owned treatment works with the concurrence of the control authority. These optional pollutant parameters are not eligible for allowance for removal achieved by the publicly owned treatment works under…","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Cd 1.2 .7"}},{"id":"aa4955f289c91e39","parameter":"Cd","value":"1.2","value_num":1.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart D—Anodizing Subcategory","existing sources (PSES)","(b) For a source discharging less than 38,000 liters (10,000 gal) per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart D—Anodizing Facilities Discharging Less Than 38,000 Liters Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.44 (PSES)","page":null,"quote":"Cd 1.2 0.7"}},{"id":"22c38e002d98b9a5","parameter":"Cd","value":"0.7","value_num":0.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart D—Anodizing Subcategory","existing sources (PSES)","(b) For a source discharging less than 38,000 liters (10,000 gal) per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart D—Anodizing Facilities Discharging Less Than 38,000 Liters Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.44 (PSES)","page":null,"quote":"Cd 1.2 0.7"}}],"next":[{"tool":"list_permits","says":"Who in this state went over on it? list_permits lists the state's permits whose last 12 months went over a limit on it, each with its record and its get_permit address; `get` is the address to fetch.","arguments":{"state":"PA","parameter":"cadmium"},"needs":{},"get":"https://passage-data.com/api/v1/permits?state=PA&parameter=cadmium","url":"https://passage-data.com/api/v1/permits?state=PA&parameter=cadmium"},{"tool":"check_values","says":"Has your user measured this? check_values sets each of their results beside every row held here, with a verdict and the row's cite.","arguments":{"place":"US-PA"},"needs":{"rows":"Your user's measured results, as their table prints them: [{parameter: \"cadmium\", value, unit}, ...], any other parameters too."},"post":"/api/v1/check","url":"https://passage-data.com/api/v1/check","page":"https://passage-data.com/limits/US-PA/cadmium#check"},{"tool":"read_certificate","says":"Has your user a laboratory certificate? read_certificate reads every row it prints, each with its page, and checks them against these limits.","arguments":{"place":"US-PA"},"needs":{"content_base64":"The laboratory's certificate (PDF) or its XLSX, XLS or CSV export, as base64; or file_url, a public https address of it."},"post":"/api/v1/certificate","url":"https://passage-data.com/api/v1/certificate","page":"https://passage-data.com/limits/US-PA/cadmium#check"}]}