{"query":{"parameter":"cadium","place":"US-MO","medium":null,"statistic":null,"kind":null},"searched":{"places":["US-MO","US"],"parameter_keys":["cas:7440-43-9","name:arsenic, cadmium (h), copper (h), lead (h), mercury, zinc","name:arsenic, cadmium (h), copper (h), lead (h), zinc","name:cadmium (h), copper (h), mercury, lead (h), zinc","name:cadmium - total","name:cadmium, total","name:cadmium, total recoverable","name:total cadmium"],"names_matched":[["cadium","cas:7440-43-9"],["arsenic cadmium h copper h lead h mercury zinc","name:arsenic, cadmium (h), copper (h), lead (h), mercury, zinc","cadmium"],["arsenic cadmium h copper h lead h mercury zinc h","name:arsenic, cadmium (h), copper (h), lead (h), mercury, zinc","cadmium"],["arsenic cadmium h copper h lead h zinc","name:arsenic, cadmium (h), copper (h), lead (h), zinc","cadmium"],["arsenic cadmium h copper h lead h zinc h","name:arsenic, cadmium (h), copper (h), lead (h), zinc","cadmium"],["cadmium h copper h mercury lead h zinc","name:cadmium (h), copper (h), mercury, lead (h), zinc","cadmium"],["cadmium h copper h mercury lead h zinc h","name:cadmium (h), copper (h), mercury, lead (h), zinc","cadmium"],["cadmium total","name:cadmium - total","cadmium"],["cadmium total","name:cadmium, total","cadmium"],["cadmium total recoverable","name:cadmium, total recoverable","cadmium"],["total cadmium","name:total cadmium","cadmium"],["total cadmium freshwater","name:total cadmium","cadmium"],["total cadmium marine","name:total cadmium","cadmium"]],"match":"exact+contains","order":"The place's own instruments first, then each place above it, each in its register's order; rows for a marine receiving water after the rest, as none of the place's own rows names a marine, salt, estuarine, coastal or ocean water"},"total":610,"offset":0,"returned":50,"next_offset":50,"rows":[{"id":"5b1f97e91ae21fd8","parameter":"Cadmium","value":"5","value_num":5,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-43-9","place":["US-MO"],"conditions":["receiving_water is freshwater","waters designated for drinking water supply"],"cite":{"instrument":"us_mo_wqs","title":"Missouri 10 CSR 20-7.031 Water Quality Standards: Table A1 criteria for designated uses, Table A2 equations, pH and the chloride-plus-sulfate limit","issuer":"State of Missouri, Clean Water Commission (Department of Natural Resources)","edition":"10 CSR 20-7.010 to 7.050, effective March 8, 2023, as US EPA posts it in effect for CWA purposes (cover July 31, 2023: EPA disapproved Table K's Sni-a-bar Creek dissolved oxygen criteria, the Joplin Turkey Creek zinc variance and some whole-body-contact use removals; no action on the Bolivar variance)","source_url":"https://www.epa.gov/system/files/documents/2023-07/mowqs.pdf","source_sha256":"edc4a64b3e9493d597a1d67fc1d5a3307c70c53cf6f35bfaf252722aba64277d","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"10 CSR 20-7.031 (5) Table A1","page":24,"quote":"Cadmium 7440439 Table A2 Table A2 5"}},{"id":"d0b057060962bf48","parameter":"Cadmium","value":"e(1.0166*ln(Hardness) – 3.062490) * (1.136672 – (ln(Hardness)*0.041838))","unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-43-9","place":["US-MO"],"conditions":["receiving_water is freshwater","waters designated for aquatic life protection (Missouri Use Designation Dataset; Tables G and H)","hardness-dependent: the printed equation; not evaluated"],"cite":{"instrument":"us_mo_wqs","title":"Missouri 10 CSR 20-7.031 Water Quality Standards: Table A1 criteria for designated uses, Table A2 equations, pH and the chloride-plus-sulfate limit","issuer":"State of Missouri, Clean Water Commission (Department of Natural Resources)","edition":"10 CSR 20-7.010 to 7.050, effective March 8, 2023, as US EPA posts it in effect for CWA purposes (cover July 31, 2023: EPA disapproved Table K's Sni-a-bar Creek dissolved oxygen criteria, the Joplin Turkey Creek zinc variance and some whole-body-contact use removals; no action on the Bolivar variance)","source_url":"https://www.epa.gov/system/files/documents/2023-07/mowqs.pdf","source_sha256":"edc4a64b3e9493d597a1d67fc1d5a3307c70c53cf6f35bfaf252722aba64277d","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"10 CSR 20-7.031 (5) Table A2","page":36,"quote":"Cadmium 7440439 Acute = e(1.0166*ln(Hardness) – 3.062490) * (1.136672 – (ln(Hardness)*0.041838)) Chronic = e(0.7977 * ln(Hardness)-3.909) * (1.101672-(ln(Hardness) * 0.041838))"}},{"id":"f85fe4364dfd2775","parameter":"Cadmium","value":"e(0.7977 * ln(Hardness)-3.909) * (1.101672-(ln(Hardness) * 0.041838))","unit":"µg/L","statistic":"four_day_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-43-9","place":["US-MO"],"conditions":["receiving_water is freshwater","waters designated for aquatic life protection (Missouri Use Designation Dataset; Tables G and H)","hardness-dependent: the printed equation; not evaluated"],"cite":{"instrument":"us_mo_wqs","title":"Missouri 10 CSR 20-7.031 Water Quality Standards: Table A1 criteria for designated uses, Table A2 equations, pH and the chloride-plus-sulfate limit","issuer":"State of Missouri, Clean Water Commission (Department of Natural Resources)","edition":"10 CSR 20-7.010 to 7.050, effective March 8, 2023, as US EPA posts it in effect for CWA purposes (cover July 31, 2023: EPA disapproved Table K's Sni-a-bar Creek dissolved oxygen criteria, the Joplin Turkey Creek zinc variance and some whole-body-contact use removals; no action on the Bolivar variance)","source_url":"https://www.epa.gov/system/files/documents/2023-07/mowqs.pdf","source_sha256":"edc4a64b3e9493d597a1d67fc1d5a3307c70c53cf6f35bfaf252722aba64277d","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"10 CSR 20-7.031 (5) Table A2","page":36,"quote":"Cadmium 7440439 Acute = e(1.0166*ln(Hardness) – 3.062490) * (1.136672 – (ln(Hardness)*0.041838)) Chronic = e(0.7977 * ln(Hardness)-3.909) * (1.101672-(ln(Hardness) * 0.041838))"}},{"id":"438d9461762b0a96","parameter":"Cadmium","value":"1.0","value_num":1,"unit":"mg/L","direction":"max","kind":"threshold","medium":"leachate","level":"national","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["(a) A solid waste (except manufactured gas plant waste) exhibits the characteristic of toxicity if, using the Toxicity Characteristic Leaching Procedure, test Method 1311 in “Test Methods for Evaluating Solid Waste, Physical/Chemical Methods,” EPA Publication SW-846, as incorporated by reference in § 260.11 of this chapter, the extract from a representative sample of the waste contains any of the contaminants listed in table 1 at the concentration equal to or greater than the respective value given in that table. Where the waste contains less than 0.5 percent filterable solids, the waste itself, after filtering using the methodology outlined in Method 1311, is considered to be the extract for the purpose of this section."],"cite":{"instrument":"us_40cfr261_24","title":"40 CFR 261.24 — Toxicity characteristic: Table 1, maximum concentration of contaminants for the toxicity characteristic (TCLP regulatory levels)","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"eCFR, 40 CFR 261.24 as of 2026-10-13 (title 40 up to date as of that day)","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-13/title-40.xml?part=261&section=261.24","source_sha256":"3a1ec9b0d3051c70e471e359275657b0fa6d98e80927d2217e82b2dbbca60961","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 261.24, Table 1","page":null,"quote":"D006 Cadmium 7440-43-9 1.0"}},{"id":"61943f113fbd68f0","parameter":"Cadmium","value":"0.69","value_num":0.69,"unit":"mg/L","statistic":"composite","direction":"max","kind":"limit","medium":"product","level":"national","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["(a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS."],"cite":{"instrument":"us_40cfr268_48","title":"40 CFR 268.48 — Universal treatment standards: Table UTS, wastewater and nonwastewater treatment standards for the hazardous constituents of land-disposal-restricted wastes","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"eCFR, 40 CFR 268.48 as of 2026-10-13 (title 40 up to date as of that day; source note: 59 FR 48103, Sept. 19, 1994, as last amended at 76 FR 34156, June 13, 2011)","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-13/title-40.xml?part=268&section=268.48","source_sha256":"70b2e58a6b1e228e2c204acc69b69fab0d5a0347e35d569959073c3dc3ee4adb","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 268.48, Table UTS, Inorganic Constituents, wastewater standard","page":null,"quote":"Cadmium 7440-43-9 0.69 0.11 mg/l TCLP"}},{"id":"dc91caad3b27226c","parameter":"Cadmium","value":"0.11 mg/l TCLP","value_num":0.11,"unit":"mg/L TCLP","statistic":"instant","direction":"max","kind":"limit","medium":"leachate","level":"national","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["(a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS."],"cite":{"instrument":"us_40cfr268_48","title":"40 CFR 268.48 — Universal treatment standards: Table UTS, wastewater and nonwastewater treatment standards for the hazardous constituents of land-disposal-restricted wastes","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"eCFR, 40 CFR 268.48 as of 2026-10-13 (title 40 up to date as of that day; source note: 59 FR 48103, Sept. 19, 1994, as last amended at 76 FR 34156, June 13, 2011)","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-13/title-40.xml?part=268&section=268.48","source_sha256":"70b2e58a6b1e228e2c204acc69b69fab0d5a0347e35d569959073c3dc3ee4adb","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 268.48, Table UTS, Inorganic Constituents, nonwastewater standard","page":null,"quote":"Cadmium 7440-43-9 0.69 0.11 mg/l TCLP"}},{"id":"f4fed814193e1e0d","parameter":"Cd","value":"1.2","value_num":1.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(b) For a source discharging less than 38,000 liters (10,000 gal.) per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart A—Common Metals Facilities Discharging Less Than 38,000 Liters Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Cd 1.2 .7"}},{"id":"dee7a50742a8188b","parameter":"Cd","value":".7","value_num":0.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(b) For a source discharging less than 38,000 liters (10,000 gal.) per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart A—Common Metals Facilities Discharging Less Than 38,000 Liters Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Cd 1.2 .7"}},{"id":"5dd56369591c22c3","parameter":"Cd","value":"1.2","value_num":1.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Cd 1.2 .7"}},{"id":"073ba142673baa6d","parameter":"Cd","value":".7","value_num":0.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Cd 1.2 .7"}},{"id":"53361efaf292ff21","parameter":"Cd","value":"47","value_num":47,"unit":"mg/sq m-Operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may be applied in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Cd 47 29"}},{"id":"262cb4ac49375d1d","parameter":"Cd","value":"29","value_num":29,"unit":"mg/sq m-Operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may be applied in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Cd 47 29"}},{"id":"89c54d05777874ae","parameter":"Cd","value":"1.2","value_num":1.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(e) For wastewater sources regulated under paragraph (c) of this section, the following optional control program may be elected by the source introducing treated process wastewater into a publicly owned treatment works with the concurrence of the control authority. These optional pollutant parameters are not eligible for allowance for removal achieved by the publicly owned treatment works under…","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Cd 1.2 .7"}},{"id":"c2ea7b79f28c3609","parameter":"Cd","value":".7","value_num":0.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(e) For wastewater sources regulated under paragraph (c) of this section, the following optional control program may be elected by the source introducing treated process wastewater into a publicly owned treatment works with the concurrence of the control authority. These optional pollutant parameters are not eligible for allowance for removal achieved by the publicly owned treatment works under…","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Cd 1.2 .7"}},{"id":"1fe2453da17667fa","parameter":"Cd","value":"1.2","value_num":1.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(b) For a source discharging less than 38,000 liters (10,000 gal) per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart B—Precious Metals Facilities Discharging Less Than 38,000 Liters Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Cd 1.2 .7"}},{"id":"8606c2ae6d5b68cd","parameter":"Cd","value":".7","value_num":0.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(b) For a source discharging less than 38,000 liters (10,000 gal) per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart B—Precious Metals Facilities Discharging Less Than 38,000 Liters Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Cd 1.2 .7"}},{"id":"0261da17b29b318e","parameter":"Cd","value":"1.2","value_num":1.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Cd 1.2 .7"}},{"id":"8ee7c192aae25f17","parameter":"Cd","value":".7","value_num":0.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Cd 1.2 .7"}},{"id":"63248eed8a79bee1","parameter":"Cd","value":"47","value_num":47,"unit":"mg/sq m-Operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Cd 47 29"}},{"id":"5447ac0e86953e1d","parameter":"Cd","value":"29","value_num":29,"unit":"mg/sq m-Operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Cd 47 29"}},{"id":"7f441ed38844c3a8","parameter":"Cd","value":"1.2","value_num":1.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(e) For wastewater sources regulated under paragraph (c) of this section, the following optional control program may be elected by the source introducing treated process wastewater into a publicly owned treatment works with the concurrence of the control authority. These optional pollutant parameters are not eligible for allowance for removal achieved by the publicly owned treatment works under…","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Cd 1.2 .7"}},{"id":"7aed455af7bc3890","parameter":"Cd","value":".7","value_num":0.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(e) For wastewater sources regulated under paragraph (c) of this section, the following optional control program may be elected by the source introducing treated process wastewater into a publicly owned treatment works with the concurrence of the control authority. These optional pollutant parameters are not eligible for allowance for removal achieved by the publicly owned treatment works under…","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Cd 1.2 .7"}},{"id":"aa4955f289c91e39","parameter":"Cd","value":"1.2","value_num":1.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart D—Anodizing Subcategory","existing sources (PSES)","(b) For a source discharging less than 38,000 liters (10,000 gal) per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart D—Anodizing Facilities Discharging Less Than 38,000 Liters Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.44 (PSES)","page":null,"quote":"Cd 1.2 0.7"}},{"id":"22c38e002d98b9a5","parameter":"Cd","value":"0.7","value_num":0.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart D—Anodizing Subcategory","existing sources (PSES)","(b) For a source discharging less than 38,000 liters (10,000 gal) per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart D—Anodizing Facilities Discharging Less Than 38,000 Liters Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.44 (PSES)","page":null,"quote":"Cd 1.2 0.7"}},{"id":"2cfdd97ae5d31144","parameter":"Cd","value":"1.2","value_num":1.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart D—Anodizing Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.44 (PSES)","page":null,"quote":"Cd 1.2 0.7"}},{"id":"4d5d1572bb96157a","parameter":"Cd","value":"0.7","value_num":0.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart D—Anodizing Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.44 (PSES)","page":null,"quote":"Cd 1.2 0.7"}},{"id":"08a3456c5098f8d9","parameter":"Cd","value":"47","value_num":47,"unit":"mg/sq m-operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart D—Anodizing Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.44 (PSES)","page":null,"quote":"Cd 47 29"}},{"id":"cad2986421401570","parameter":"Cd","value":"29","value_num":29,"unit":"mg/sq m-operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart D—Anodizing Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.44 (PSES)","page":null,"quote":"Cd 47 29"}},{"id":"107f8bed3b82cede","parameter":"Cd","value":"1.2","value_num":1.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart D—Anodizing Subcategory","existing sources (PSES)","(e) For wastewater sources regulated under paragraph (c) of this section, the following optional control program may be elected by the source introducing treated process wastewater into a publicly owned treatment works with the concurrence of the control authority. These optional pollutant parameters are not eligible for allowance for removal achieved by the publicly owned treatment works under…","table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.44 (PSES)","page":null,"quote":"Cd 1.2 0.7"}},{"id":"98d300b02c6e1d55","parameter":"Cd","value":"0.7","value_num":0.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart D—Anodizing Subcategory","existing sources (PSES)","(e) For wastewater sources regulated under paragraph (c) of this section, the following optional control program may be elected by the source introducing treated process wastewater into a publicly owned treatment works with the concurrence of the control authority. These optional pollutant parameters are not eligible for allowance for removal achieved by the publicly owned treatment works under…","table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.44 (PSES)","page":null,"quote":"Cd 1.2 0.7"}},{"id":"5839e06de4a040ca","parameter":"Cd","value":"1.2","value_num":1.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart E—Coatings Subcategory","existing sources (PSES)","(b) For a source discharging less than 38,000 liters (10,000 gal) per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart E—Coatings Facilities Discharging Less Than 38,000 Liters Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.54 (PSES)","page":null,"quote":"Cd 1.2 0.7"}},{"id":"2c0bdf7d4bdce563","parameter":"Cd","value":"0.7","value_num":0.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart E—Coatings Subcategory","existing sources (PSES)","(b) For a source discharging less than 38,000 liters (10,000 gal) per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart E—Coatings Facilities Discharging Less Than 38,000 Liters Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.54 (PSES)","page":null,"quote":"Cd 1.2 0.7"}},{"id":"57e5aab250720cc8","parameter":"Cd","value":"1.2","value_num":1.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart E—Coatings Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart E—Coatings Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.54 (PSES)","page":null,"quote":"Cd 1.2 0.7"}},{"id":"ea78eaf4a94885c8","parameter":"Cd","value":"0.7","value_num":0.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart E—Coatings Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart E—Coatings Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.54 (PSES)","page":null,"quote":"Cd 1.2 0.7"}},{"id":"29112c33c6520287","parameter":"Cd","value":"47","value_num":47,"unit":"mg/sq m-operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart E—Coatings Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart E—Coatings Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.54 (PSES)","page":null,"quote":"Cd 47 29"}},{"id":"41d896b42eae9328","parameter":"Cd","value":"29","value_num":29,"unit":"mg/sq m-operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart E—Coatings Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart E—Coatings Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.54 (PSES)","page":null,"quote":"Cd 47 29"}},{"id":"4378783f6b9a7f57","parameter":"Cd","value":"1.2","value_num":1.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart E—Coatings Subcategory","existing sources (PSES)","(e) For wastewater sources regulated under paragraph (c) of this section, the following optional control program may be elected by the source introducing treated process wastewater into a publicly owned treatment works with the concurrence of the control authority. These optional pollutant parameters are not eligible for allowance for removal achieved by the publicly owned treatment works under…","table: Subpart E—Coatings Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.54 (PSES)","page":null,"quote":"Cd 1.2 0.7"}},{"id":"4f4056eceab0d639","parameter":"Cd","value":"0.7","value_num":0.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart E—Coatings Subcategory","existing sources (PSES)","(e) For wastewater sources regulated under paragraph (c) of this section, the following optional control program may be elected by the source introducing treated process wastewater into a publicly owned treatment works with the concurrence of the control authority. These optional pollutant parameters are not eligible for allowance for removal achieved by the publicly owned treatment works under…","table: Subpart E—Coatings Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.54 (PSES)","page":null,"quote":"Cd 1.2 0.7"}},{"id":"13ed719924657b1d","parameter":"Cd","value":"1.2","value_num":1.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart F—Chemical Etching and Milling Subcategory","existing sources (PSES)","(b) For a source discharging less than 38,000 liters (10,000 gal.) per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart F—Chemical Etching and Milling Facilities Discharging Less Than 38,000 Liters Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.64 (PSES)","page":null,"quote":"Cd 1.2 0.7"}},{"id":"2b768c7b9feca1e4","parameter":"Cd","value":"0.7","value_num":0.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart F—Chemical Etching and Milling Subcategory","existing sources (PSES)","(b) For a source discharging less than 38,000 liters (10,000 gal.) per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart F—Chemical Etching and Milling Facilities Discharging Less Than 38,000 Liters Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.64 (PSES)","page":null,"quote":"Cd 1.2 0.7"}},{"id":"858b7432fe165b07","parameter":"Cd","value":"1.2","value_num":1.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart F—Chemical Etching and Milling Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal.) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart F—Chemicals Etching and Milling Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.64 (PSES)","page":null,"quote":"Cd 1.2 0.7"}},{"id":"4d8940c9eef42012","parameter":"Cd","value":"0.7","value_num":0.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart F—Chemical Etching and Milling Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal.) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart F—Chemicals Etching and Milling Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.64 (PSES)","page":null,"quote":"Cd 1.2 0.7"}},{"id":"cd7db2711b10e310","parameter":"Cd","value":"47","value_num":47,"unit":"mg/sq m-operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart F—Chemical Etching and Milling Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart F—Chemical Etching and Milling Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.64 (PSES)","page":null,"quote":"Cd 47 29"}},{"id":"ef6ca0599f62850b","parameter":"Cd","value":"29","value_num":29,"unit":"mg/sq m-operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart F—Chemical Etching and Milling Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart F—Chemical Etching and Milling Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.64 (PSES)","page":null,"quote":"Cd 47 29"}},{"id":"6519ef56969b7fca","parameter":"Cd","value":"1.2","value_num":1.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart F—Chemical Etching and Milling Subcategory","existing sources (PSES)","(e) For wastewater sources regulated under paragraph (c) of this section, the following optional control program may be elected by the source introducing treated process wastewater into a publicly owned treatment works with the concurrence of the control authority. These optional pollutant parameters are not eligible for allowance for removal achieved by the publicly owned treatment works under…","table: Subpart F—Chemical Etching and Milling Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.64 (PSES)","page":null,"quote":"Cd 1.2 0.7"}},{"id":"1e3368e4ffe0cf0b","parameter":"Cd","value":"0.7","value_num":0.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart F—Chemical Etching and Milling Subcategory","existing sources (PSES)","(e) For wastewater sources regulated under paragraph (c) of this section, the following optional control program may be elected by the source introducing treated process wastewater into a publicly owned treatment works with the concurrence of the control authority. These optional pollutant parameters are not eligible for allowance for removal achieved by the publicly owned treatment works under…","table: Subpart F—Chemical Etching and Milling Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.64 (PSES)","page":null,"quote":"Cd 1.2 0.7"}},{"id":"9bc7b0674569840d","parameter":"Cd","value":"1.2","value_num":1.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart G—Electroless Plating Subcategory","existing sources (PSES)","(b) For a source discharging less than 38,000 liters (10,000 gal.) per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart G—Electroless Plating Facilities Discharging Less Than 38,000 Liters Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.74 (PSES)","page":null,"quote":"Cd 1.2 0.7"}},{"id":"f1d26ec2db2fa193","parameter":"Cd","value":"0.7","value_num":0.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart G—Electroless Plating Subcategory","existing sources (PSES)","(b) For a source discharging less than 38,000 liters (10,000 gal.) per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart G—Electroless Plating Facilities Discharging Less Than 38,000 Liters Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.74 (PSES)","page":null,"quote":"Cd 1.2 0.7"}},{"id":"149735d6b1bcedb5","parameter":"Cd","value":"1.2","value_num":1.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart G—Electroless Plating Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 l (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart G—Electroless Plating Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.74 (PSES)","page":null,"quote":"Cd 1.2 0.7"}},{"id":"91a6d6c3ac81dd14","parameter":"Cd","value":"0.7","value_num":0.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-43-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart G—Electroless Plating Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 l (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart G—Electroless Plating Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 413.74 (PSES)","page":null,"quote":"Cd 1.2 0.7"}}],"next":[{"tool":"check_values","says":"Has your user measured this? check_values sets each of their results beside every row held here, with a verdict and the row's cite.","arguments":{"place":"US-MO"},"needs":{"rows":"Your user's measured results, as their table prints them: [{parameter: \"cadium\", value, unit}, ...], any other parameters too."},"post":"/api/v1/check"},{"tool":"read_certificate","says":"Has your user a laboratory certificate? read_certificate reads every row it prints, each with its page, and checks them against these limits.","arguments":{"place":"US-MO"},"needs":{"content_base64":"The laboratory's certificate (PDF) or its XLSX, XLS or CSV export, as base64; or file_url, a public https address of it."},"post":"/api/v1/certificate"}]}