{"query":{"parameter":"arsenic","place":"US-CA","medium":null,"statistic":null,"kind":null},"searched":{"places":["US-CA","US"],"parameter_keys":["cas:7440-38-2","name:arsenic (+3)","name:arsenic, cadmium (h), copper (h), lead (h), mercury, zinc","name:arsenic, cadmium (h), copper (h), lead (h), zinc","name:arsenic, dissolved","name:arsenic iii","name:arsenic extractible","name:arsenic - total","name:arsenic, total","name:arsenic v","name:chemical oxygen demand, arsenic, radium (dissolved and total, uranium, zinc","name:total arsenic"],"names_matched":[["arsenic","cas:7440-38-2"],["arsenic 3","name:arsenic (+3)"],["arsenic 3 total recoverable","name:arsenic (+3)"],["arsenic cadmium h copper h lead h mercury zinc","name:arsenic, cadmium (h), copper (h), lead (h), mercury, zinc"],["arsenic cadmium h copper h lead h mercury zinc h","name:arsenic, cadmium (h), copper (h), lead (h), mercury, zinc"],["arsenic cadmium h copper h lead h zinc","name:arsenic, cadmium (h), copper (h), lead (h), zinc"],["arsenic cadmium h copper h lead h zinc h","name:arsenic, cadmium (h), copper (h), lead (h), zinc"],["arsenic dissolved","name:arsenic, dissolved"],["arsenic dissolved trivalent","name:arsenic iii"],["arsenic extractible","name:arsenic extractible"],["arsenic iii","name:arsenic iii"],["arsenic iii dissolved","name:arsenic iii"],["arsenic iii total recoverable","name:arsenic iii"],["arsenic total","name:arsenic - total"],["arsenic total","name:arsenic, total"],["arsenic trivalent","name:arsenic iii"],["arsenic trivalent dissolved","name:arsenic iii"],["arsenic v","name:arsenic v"],["chemical oxygen demand arsenic radium dissolved and total uranium zinc","name:chemical oxygen demand, arsenic, radium (dissolved and total, uranium, zinc"],["chemical oxygen demand arsenic radium dissolved and total uranium zinc h","name:chemical oxygen demand, arsenic, radium (dissolved and total, uranium, zinc"],["total arsenic","name:total arsenic"],["total arsenic freshwater","name:total arsenic"],["total arsenic marine","name:total arsenic"]],"match":"exact+contains","order":"The place's own instruments first, then each place above it, each in its register's order"},"total":470,"offset":0,"returned":50,"next_offset":50,"rows":[{"id":"ea5220bfd0271eb7","parameter":"Arsenic","value":"340 i,m,w","value_num":340,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-38-2","place":["US-CA"],"conditions":["receiving_water is freshwater","inland surface waters and enclosed bays and estuaries of California (not ocean waters, which the Ocean Plan covers) (40 CFR 131.38(a), (d)(1))","freshwater criteria: waters whose salinity is 1 part per thousand or less 95% or more of the time; between 1 and 10 ppt the more stringent of the freshwater and saltwater criteria applies (40 CFR 131.38(c)(3))"],"cite":{"instrument":"us_ca_ctr","title":"California Toxics Rule, 40 CFR 131.38: numeric criteria for priority toxic pollutants for California's inland surface waters and enclosed bays and estuaries (freshwater and saltwater CMC/CCC, human health)","issuer":"US Environmental Protection Agency (promulgated for the State of California)","edition":"40 CFR 131.38(b)(1) Table 1 as republished in full by the final rule 'Water Quality Standards; Establishment of a Numeric Criterion for Selenium for the State of California' (89 FR 101914, December 17, 2024), the table eCFR serves today (as images); paragraphs (c)-(d) from eCFR as of 2026-10-01","source_url":"https://www.govinfo.gov/content/pkg/FR-2024-12-17/pdf/2024-29483.pdf","source_sha256":"563001982d0d74d96f6eb7222df4c125bf5e9809c77ab2f84ff948a3b87edfe2","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 131.38(b)(1) Table 1","page":16,"quote":"2. Arsenic b 7440382 340 i,m,w 150 i,m,w 69i,m 36 i,m","transcription":"OCR text layer of a printed table image (Federal Register); the image itself is the authority"}},{"id":"e83a45f951f8a1a6","parameter":"Arsenic","value":"150 i,m,w","value_num":150,"unit":"µg/L","statistic":"four_day_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-38-2","place":["US-CA"],"conditions":["receiving_water is freshwater","inland surface waters and enclosed bays and estuaries of California (not ocean waters, which the Ocean Plan covers) (40 CFR 131.38(a), (d)(1))","freshwater criteria: waters whose salinity is 1 part per thousand or less 95% or more of the time; between 1 and 10 ppt the more stringent of the freshwater and saltwater criteria applies (40 CFR 131.38(c)(3))"],"cite":{"instrument":"us_ca_ctr","title":"California Toxics Rule, 40 CFR 131.38: numeric criteria for priority toxic pollutants for California's inland surface waters and enclosed bays and estuaries (freshwater and saltwater CMC/CCC, human health)","issuer":"US Environmental Protection Agency (promulgated for the State of California)","edition":"40 CFR 131.38(b)(1) Table 1 as republished in full by the final rule 'Water Quality Standards; Establishment of a Numeric Criterion for Selenium for the State of California' (89 FR 101914, December 17, 2024), the table eCFR serves today (as images); paragraphs (c)-(d) from eCFR as of 2026-10-01","source_url":"https://www.govinfo.gov/content/pkg/FR-2024-12-17/pdf/2024-29483.pdf","source_sha256":"563001982d0d74d96f6eb7222df4c125bf5e9809c77ab2f84ff948a3b87edfe2","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 131.38(b)(1) Table 1","page":16,"quote":"2. Arsenic b 7440382 340 i,m,w 150 i,m,w 69i,m 36 i,m","transcription":"OCR text layer of a printed table image (Federal Register); the image itself is the authority"}},{"id":"006383c352e6bc21","parameter":"Arsenic","value":"69i,m","value_num":69,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-38-2","place":["US-CA"],"conditions":["receiving_water is marine","inland surface waters and enclosed bays and estuaries of California (not ocean waters, which the Ocean Plan covers) (40 CFR 131.38(a), (d)(1))","saltwater criteria: waters whose salinity is 10 parts per thousand or more 95% or more of the time; between 1 and 10 ppt the more stringent of the freshwater and saltwater criteria applies (40 CFR 131.38(c)(3))"],"cite":{"instrument":"us_ca_ctr","title":"California Toxics Rule, 40 CFR 131.38: numeric criteria for priority toxic pollutants for California's inland surface waters and enclosed bays and estuaries (freshwater and saltwater CMC/CCC, human health)","issuer":"US Environmental Protection Agency (promulgated for the State of California)","edition":"40 CFR 131.38(b)(1) Table 1 as republished in full by the final rule 'Water Quality Standards; Establishment of a Numeric Criterion for Selenium for the State of California' (89 FR 101914, December 17, 2024), the table eCFR serves today (as images); paragraphs (c)-(d) from eCFR as of 2026-10-01","source_url":"https://www.govinfo.gov/content/pkg/FR-2024-12-17/pdf/2024-29483.pdf","source_sha256":"563001982d0d74d96f6eb7222df4c125bf5e9809c77ab2f84ff948a3b87edfe2","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 131.38(b)(1) Table 1","page":16,"quote":"2. Arsenic b 7440382 340 i,m,w 150 i,m,w 69i,m 36 i,m","transcription":"OCR text layer of a printed table image (Federal Register); the image itself is the authority"}},{"id":"2aa06d50953908ad","parameter":"Arsenic","value":"36 i,m","value_num":36,"unit":"µg/L","statistic":"four_day_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-38-2","place":["US-CA"],"conditions":["receiving_water is marine","inland surface waters and enclosed bays and estuaries of California (not ocean waters, which the Ocean Plan covers) (40 CFR 131.38(a), (d)(1))","saltwater criteria: waters whose salinity is 10 parts per thousand or more 95% or more of the time; between 1 and 10 ppt the more stringent of the freshwater and saltwater criteria applies (40 CFR 131.38(c)(3))"],"cite":{"instrument":"us_ca_ctr","title":"California Toxics Rule, 40 CFR 131.38: numeric criteria for priority toxic pollutants for California's inland surface waters and enclosed bays and estuaries (freshwater and saltwater CMC/CCC, human health)","issuer":"US Environmental Protection Agency (promulgated for the State of California)","edition":"40 CFR 131.38(b)(1) Table 1 as republished in full by the final rule 'Water Quality Standards; Establishment of a Numeric Criterion for Selenium for the State of California' (89 FR 101914, December 17, 2024), the table eCFR serves today (as images); paragraphs (c)-(d) from eCFR as of 2026-10-01","source_url":"https://www.govinfo.gov/content/pkg/FR-2024-12-17/pdf/2024-29483.pdf","source_sha256":"563001982d0d74d96f6eb7222df4c125bf5e9809c77ab2f84ff948a3b87edfe2","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 131.38(b)(1) Table 1","page":16,"quote":"2. Arsenic b 7440382 340 i,m,w 150 i,m,w 69i,m 36 i,m","transcription":"OCR text layer of a printed table image (Federal Register); the image itself is the authority"}},{"id":"2954140e5b83b429","parameter":"Arsenic","value":"1.4E-01","value_num":0.14,"unit":"µg/L","direction":"max","kind":"guideline","medium":"groundwater","level":"regional","parameter_key":"cas:7440-38-2","place":["US-CA"],"conditions":["Tier 1 ESLs: one level per chemical and medium for a generic site (residential land use, groundwater a drinking-water resource, shallow soil); a screening level is not a cleanup standard"],"cite":{"instrument":"us_ca_esl_groundwater","title":"California, San Francisco Bay RWQCB — Environmental Screening Levels (ESLs), Tier 1, 2025 (Rev. 4) — groundwater","issuer":"San Francisco Bay Regional Water Quality Control Board","edition":"2025 (Rev. 4)","source_url":"https://www.waterboards.ca.gov/sanfranciscobay/water_issues/programs/ESL/ESL_Summary_Tables_Rev4.pdf","source_sha256":null,"fetched_at":"2026-09-30","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":null,"page":null,"quote":null,"table":"eau","column":"tier1"}},{"id":"8d623da50252b5cb","parameter":"Arsenic","value":"3.2E-02","value_num":0.032,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"regional","parameter_key":"cas:7440-38-2","place":["US-CA"],"conditions":["Tier 1 ESLs: one level per chemical and medium for a generic site (residential land use, groundwater a drinking-water resource, shallow soil); a screening level is not a cleanup standard"],"cite":{"instrument":"us_ca_esl_soil","title":"California, San Francisco Bay RWQCB — Environmental Screening Levels (ESLs), Tier 1, 2025 (Rev. 4) — soil","issuer":"San Francisco Bay Regional Water Quality Control Board","edition":"2025 (Rev. 4)","source_url":"https://www.waterboards.ca.gov/sanfranciscobay/water_issues/programs/ESL/ESL_Summary_Tables_Rev4.pdf","source_sha256":null,"fetched_at":"2026-09-30","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":null,"page":null,"quote":null,"table":"sols","column":"tier1"}},{"id":"e3b103e75aa7b965","parameter":"Arsenic","value":"8.","value_num":8,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-38-2","place":["US-CA"],"conditions":["receiving_water is marine","ocean waters of California (the territorial sea and the waters beyond the enclosed bays, estuaries and coastal lagoons): the Ocean Plan's jurisdiction","in the receiving water upon completion of initial dilution (chapter III.C.3)"],"cite":{"instrument":"us_ca_ocean_plan","title":"Water Quality Control Plan for Ocean Waters of California (California Ocean Plan, 2019): Table 3 water quality objectives, Table 4 effluent limitations, and the salinity limitation for desalination brine","issuer":"State of California, State Water Resources Control Board","edition":"California Ocean Plan 2019, effective February 4, 2019 (State Water Resources Control Board; includes the 2015 desalination amendment, effective January 28, 2016), as the State Water Board serves it 2026-10-14","source_url":"https://www.waterboards.ca.gov/water_issues/programs/ocean/docs/oceanplan2019.pdf","source_sha256":"cbff9eaf5b7df1c9b818190851d4196e26c53b56b1860ce11fc44bdf125a5d6c","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"Ocean Plan chapter II.D, Table 3, objectives for protection of marine aquatic life","page":17,"quote":null}},{"id":"d58cb97623e31eda","parameter":"Arsenic","value":"32.","value_num":32,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-38-2","place":["US-CA"],"conditions":["receiving_water is marine","ocean waters of California (the territorial sea and the waters beyond the enclosed bays, estuaries and coastal lagoons): the Ocean Plan's jurisdiction","in the receiving water upon completion of initial dilution (chapter III.C.3)"],"cite":{"instrument":"us_ca_ocean_plan","title":"Water Quality Control Plan for Ocean Waters of California (California Ocean Plan, 2019): Table 3 water quality objectives, Table 4 effluent limitations, and the salinity limitation for desalination brine","issuer":"State of California, State Water Resources Control Board","edition":"California Ocean Plan 2019, effective February 4, 2019 (State Water Resources Control Board; includes the 2015 desalination amendment, effective January 28, 2016), as the State Water Board serves it 2026-10-14","source_url":"https://www.waterboards.ca.gov/water_issues/programs/ocean/docs/oceanplan2019.pdf","source_sha256":"cbff9eaf5b7df1c9b818190851d4196e26c53b56b1860ce11fc44bdf125a5d6c","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"Ocean Plan chapter II.D, Table 3, objectives for protection of marine aquatic life","page":17,"quote":null}},{"id":"223b1d7910325974","parameter":"Arsenic","value":"80.","value_num":80,"unit":"µg/L","statistic":"instant","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-38-2","place":["US-CA"],"conditions":["receiving_water is marine","ocean waters of California (the territorial sea and the waters beyond the enclosed bays, estuaries and coastal lagoons): the Ocean Plan's jurisdiction","in the receiving water upon completion of initial dilution (chapter III.C.3)"],"cite":{"instrument":"us_ca_ocean_plan","title":"Water Quality Control Plan for Ocean Waters of California (California Ocean Plan, 2019): Table 3 water quality objectives, Table 4 effluent limitations, and the salinity limitation for desalination brine","issuer":"State of California, State Water Resources Control Board","edition":"California Ocean Plan 2019, effective February 4, 2019 (State Water Resources Control Board; includes the 2015 desalination amendment, effective January 28, 2016), as the State Water Board serves it 2026-10-14","source_url":"https://www.waterboards.ca.gov/water_issues/programs/ocean/docs/oceanplan2019.pdf","source_sha256":"cbff9eaf5b7df1c9b818190851d4196e26c53b56b1860ce11fc44bdf125a5d6c","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"Ocean Plan chapter II.D, Table 3, objectives for protection of marine aquatic life","page":17,"quote":null}},{"id":"6bf2cf5df76a9ba4","parameter":"Arsenic","value":"5.0","value_num":5,"unit":"mg/L","direction":"max","kind":"threshold","medium":"leachate","level":"national","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["(a) A solid waste (except manufactured gas plant waste) exhibits the characteristic of toxicity if, using the Toxicity Characteristic Leaching Procedure, test Method 1311 in “Test Methods for Evaluating Solid Waste, Physical/Chemical Methods,” EPA Publication SW-846, as incorporated by reference in § 260.11 of this chapter, the extract from a representative sample of the waste contains any of the contaminants listed in table 1 at the concentration equal to or greater than the respective value given in that table. Where the waste contains less than 0.5 percent filterable solids, the waste itself, after filtering using the methodology outlined in Method 1311, is considered to be the extract for the purpose of this section."],"cite":{"instrument":"us_40cfr261_24","title":"40 CFR 261.24 — Toxicity characteristic: Table 1, maximum concentration of contaminants for the toxicity characteristic (TCLP regulatory levels)","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"eCFR, 40 CFR 261.24 as of 2026-10-13 (title 40 up to date as of that day)","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-13/title-40.xml?part=261&section=261.24","source_sha256":"3a1ec9b0d3051c70e471e359275657b0fa6d98e80927d2217e82b2dbbca60961","fetched_at":"2026-10-15","section":"40 CFR 261.24, Table 1","page":null,"quote":"D004 Arsenic 7440-38-2 5.0"}},{"id":"10ce38e3a1e24b12","parameter":"Arsenic","value":"0.0028","value_num":0.0028,"unit":"Kg/kkg (or pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart AB—Boric Acid Production Subcategory","existing sources (BPT)","table: Subpart AB—Boric Acid Mined Borax Process"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.282 (BPT)","page":null,"quote":"Arsenic 0.0028 0.0014"}},{"id":"e7aa0eb80ced1a79","parameter":"Arsenic","value":"0.0014","value_num":0.0014,"unit":"Kg/kkg (or pounds per 1,000 lb) of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart AB—Boric Acid Production Subcategory","existing sources (BPT)","table: Subpart AB—Boric Acid Mined Borax Process"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.282 (BPT)","page":null,"quote":"Arsenic 0.0028 0.0014"}},{"id":"d85505630132fd04","parameter":"Arsenic (T)","value":"3.0","value_num":3,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart BO—Zinc Chloride Production Subcategory","existing sources (BPT)","table: Subpart BO—Zinc Chloride"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.672 (BPT)","page":null,"quote":"Arsenic (T) 3.0 1.0"}},{"id":"6fddf606cf5a4f5c","parameter":"Arsenic (T)","value":"1.0","value_num":1,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart BO—Zinc Chloride Production Subcategory","existing sources (BPT)","table: Subpart BO—Zinc Chloride"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.672 (BPT)","page":null,"quote":"Arsenic (T) 3.0 1.0"}},{"id":"69a7289126d21d9f","parameter":"Arsenic (T)","value":"3.0","value_num":3,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart BO—Zinc Chloride Production Subcategory","existing sources (BAT)","table: Subpart BO—Zinc Chloride"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.673 (BAT)","page":null,"quote":"Arsenic (T) 3.0 1.0"}},{"id":"a2e2255d77c4910d","parameter":"Arsenic (T)","value":"1.0","value_num":1,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart BO—Zinc Chloride Production Subcategory","existing sources (BAT)","table: Subpart BO—Zinc Chloride"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.673 (BAT)","page":null,"quote":"Arsenic (T) 3.0 1.0"}},{"id":"5487bb193ee472a3","parameter":"Arsenic (T)","value":"3.0","value_num":3,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart BO—Zinc Chloride Production Subcategory","existing sources (PSES)","table: Subpart BO—Zinc Chloride"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.674 (PSES)","page":null,"quote":"Arsenic (T) 3.0 1.0"}},{"id":"822660b4b2d41d04","parameter":"Arsenic (T)","value":"1.0","value_num":1,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart BO—Zinc Chloride Production Subcategory","existing sources (PSES)","table: Subpart BO—Zinc Chloride"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.674 (PSES)","page":null,"quote":"Arsenic (T) 3.0 1.0"}},{"id":"a7a75c612965ce37","parameter":"Arsenic (T)","value":"3.0","value_num":3,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart BO—Zinc Chloride Production Subcategory","new sources (NSPS)","Any new source subject to this subpart must achieve the following new source performance standards (NSPS):","table: Subpart BO—Zinc Chloride"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 415.675 (NSPS)","page":null,"quote":"Arsenic (T) 3.0 1.0."}},{"id":"55bd83fbce8453f9","parameter":"Arsenic","value":".692","value_num":0.692,"unit":"mg/kg (pounds per million pounds) of copper cast","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","existing sources (BAT)","(a) Subpart E—Casting Contact Cooling.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.53 (BAT)","page":null,"quote":"Arsenic .692 .309"}},{"id":"bd6c1bac4f0b0565","parameter":"Arsenic","value":".309","value_num":0.309,"unit":"mg/kg (pounds per million pounds) of copper cast","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","existing sources (BAT)","(a) Subpart E—Casting Contact Cooling.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.53 (BAT)","page":null,"quote":"Arsenic .692 .309"}},{"id":"e8ae735e0f11cf63","parameter":"Arsenic","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of cathode copper production","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","existing sources (BAT)","(b) Subpart E—Anode and Cathode Rinse.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.53 (BAT)","page":null,"quote":"Arsenic .000 .000"}},{"id":"bd65104ec3fdc6e8","parameter":"Arsenic","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of cathode copper production","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","existing sources (BAT)","(b) Subpart E—Anode and Cathode Rinse.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.53 (BAT)","page":null,"quote":"Arsenic .000 .000"}},{"id":"77b3a4f99f2e96a6","parameter":"Arsenic","value":".068","value_num":0.068,"unit":"mg/kg (pounds per million pounds) of copper cathode production","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","existing sources (BAT)","(c) Subpart E—Spent Electrolyte.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.53 (BAT)","page":null,"quote":"Arsenic .068 .031"}},{"id":"3bfe2f99d007406e","parameter":"Arsenic","value":".031","value_num":0.031,"unit":"mg/kg (pounds per million pounds) of copper cathode production","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","existing sources (BAT)","(c) Subpart E—Spent Electrolyte.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.53 (BAT)","page":null,"quote":"Arsenic .068 .031"}},{"id":"03b6b3d4f821024e","parameter":"Arsenic","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of casting production","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","existing sources (BAT)","(d) Subpart E—Casting Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.53 (BAT)","page":null,"quote":"Arsenic .000 .000"}},{"id":"527fea9449c591f6","parameter":"Arsenic","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of casting production","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","existing sources (BAT)","(d) Subpart E—Casting Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.53 (BAT)","page":null,"quote":"Arsenic .000 .000"}},{"id":"b7c77b891623af67","parameter":"Arsenic","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of product recovered from electrolytic slimes processing","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","existing sources (BAT)","(e) Subpart E—By-Product Recovery.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.53 (BAT)","page":null,"quote":"Arsenic .000 .000"}},{"id":"0f91575cd889afb3","parameter":"Arsenic","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of product recovered from electrolytic slimes processing","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","existing sources (BAT)","(e) Subpart E—By-Product Recovery.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.53 (BAT)","page":null,"quote":"Arsenic .000 .000"}},{"id":"72f23484c7b2f9d6","parameter":"Arsenic","value":".692","value_num":0.692,"unit":"mg/kg (pounds per million pounds) of copper cast","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (NSPS)","(a) Subpart E—Casting Contact Cooling.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.54 (NSPS)","page":null,"quote":"Arsenic .692 .309"}},{"id":"9fbed9e85cb00bcd","parameter":"Arsenic","value":".309","value_num":0.309,"unit":"mg/kg (pounds per million pounds) of copper cast","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (NSPS)","(a) Subpart E—Casting Contact Cooling.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.54 (NSPS)","page":null,"quote":"Arsenic .692 .309"}},{"id":"cb32624ac96240fb","parameter":"Arsenic","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of cathode copper production","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (NSPS)","(b) Subpart E—Anode and Cathode Rinse.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.54 (NSPS)","page":null,"quote":"Arsenic .000 .000"}},{"id":"0d540255c79182ab","parameter":"Arsenic","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of cathode copper production","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (NSPS)","(b) Subpart E—Anode and Cathode Rinse.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.54 (NSPS)","page":null,"quote":"Arsenic .000 .000"}},{"id":"1e8ffcddf1000b1b","parameter":"Arsenic","value":".068","value_num":0.068,"unit":"mg/kg (pounds per million pounds) of copper cathode production","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (NSPS)","(c) Subpart E—Spent Electrolyte.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.54 (NSPS)","page":null,"quote":"Arsenic .068 .031"}},{"id":"fa83b81b02fa85ba","parameter":"Arsenic","value":".031","value_num":0.031,"unit":"mg/kg (pounds per million pounds) of copper cathode production","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (NSPS)","(c) Subpart E—Spent Electrolyte.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.54 (NSPS)","page":null,"quote":"Arsenic .068 .031"}},{"id":"95c8ea14a97de8e0","parameter":"Arsenic","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of casting production","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (NSPS)","(d) Subpart E—Casting Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.54 (NSPS)","page":null,"quote":"Arsenic .000 .000"}},{"id":"d49b5c6208c1f98a","parameter":"Arsenic","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of casting production","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (NSPS)","(d) Subpart E—Casting Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.54 (NSPS)","page":null,"quote":"Arsenic .000 .000"}},{"id":"d910cca40d8efd71","parameter":"Arsenic","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of product recovered from electrolytic slimes processing","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (NSPS)","(e) Subpart E—By-Product Recovery.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.54 (NSPS)","page":null,"quote":"Arsenic .000 .000"}},{"id":"6783f62d5d7772c7","parameter":"Arsenic","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of product recovered from electrolytic slimes processing","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (NSPS)","(e) Subpart E—By-Product Recovery.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.54 (NSPS)","page":null,"quote":"Arsenic .000 .000"}},{"id":"f65832080bc124b6","parameter":"Arsenic","value":".692","value_num":0.692,"unit":"mg/kg (pounds per million pounds) of copper cast","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (PSNS)","(a) Subpart E—Casting Contact Cooling.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.56 (PSNS)","page":null,"quote":"Arsenic .692 .309"}},{"id":"12a50162d8cf0558","parameter":"Arsenic","value":".309","value_num":0.309,"unit":"mg/kg (pounds per million pounds) of copper cast","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (PSNS)","(a) Subpart E—Casting Contact Cooling.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.56 (PSNS)","page":null,"quote":"Arsenic .692 .309"}},{"id":"451652b932db1d1e","parameter":"Arsenic","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of cathode copper production","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (PSNS)","(b) Subpart E—Anode and Cathode Rinse.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.56 (PSNS)","page":null,"quote":"Arsenic .000 .000"}},{"id":"32d825b41a41d531","parameter":"Arsenic","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of cathode copper production","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (PSNS)","(b) Subpart E—Anode and Cathode Rinse.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.56 (PSNS)","page":null,"quote":"Arsenic .000 .000"}},{"id":"96a34cf81e513792","parameter":"Arsenic","value":".068","value_num":0.068,"unit":"mg/kg (pounds per million pounds) of cathode copper production","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (PSNS)","(c) Subpart E—Spent Electrolyte.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.56 (PSNS)","page":null,"quote":"Arsenic .068 .031"}},{"id":"f422c19eac0edd3a","parameter":"Arsenic","value":".031","value_num":0.031,"unit":"mg/kg (pounds per million pounds) of cathode copper production","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (PSNS)","(c) Subpart E—Spent Electrolyte.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.56 (PSNS)","page":null,"quote":"Arsenic .068 .031"}},{"id":"7cf5aa968065fd07","parameter":"Arsenic","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of casting production","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (PSNS)","(d) Subpart E—Casting Wet Air Pollution Control.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.56 (PSNS)","page":null,"quote":"Arsenic .000 .000"}},{"id":"bc1a4bdb5f0b55b3","parameter":"Arsenic","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of casting production","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (PSNS)","(d) Subpart E—Casting Wet Air Pollution Control.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.56 (PSNS)","page":null,"quote":"Arsenic .000 .000"}},{"id":"23427f9a7dd21699","parameter":"Arsenic","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of product recovered from electrolytic slimes processing","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (PSNS)","(e) Subpart E—By-Product Recovery.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.56 (PSNS)","page":null,"quote":"Arsenic .000 .000"}},{"id":"ab817995fb22164f","parameter":"Arsenic","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of product recovered from electrolytic slimes processing","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (PSNS)","(e) Subpart E—By-Product Recovery.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.56 (PSNS)","page":null,"quote":"Arsenic .000 .000"}},{"id":"70a73ecc43d86311","parameter":"As","value":"0.0016","value_num":0.0016,"unit":"(1) English Units (pounds per 1,000 pounds of product)","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-38-2","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart H—Primary Zinc Subcategory","existing sources (BPT)","table: Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.82 (BPT)","page":null,"quote":"As 0.0016 0.0008"}}],"next":[{"tool":"check_values","says":"Has your user measured this? check_values sets each of their results beside every row held here, with a verdict and the row's cite.","arguments":{"place":"US-CA"},"needs":{"rows":"Your user's measured results, as their table prints them: [{parameter: \"arsenic\", value, unit}, ...], any other parameters too."},"post":"/api/v1/check"},{"tool":"read_certificate","says":"Has your user a laboratory certificate? read_certificate reads every row it prints, each with its page, and checks them against these limits.","arguments":{"place":"US-CA"},"needs":{"content_base64":"The laboratory's certificate (PDF) or its XLSX, XLS or CSV export, as base64; or file_url, a public https address of it."},"post":"/api/v1/certificate"}]}