{"query":{"parameter":"antimony","place":"US-CO","medium":null,"statistic":null,"kind":null},"searched":{"places":["US-CO","US"],"parameter_keys":["cas:7440-36-0","name:antimony-122","name:antimony-124","name:antimony-125","cas:1332-81-6","cas:1314-60-9","name:antimony, total","cas:1309-64-4"],"names_matched":[["antimony","cas:7440-36-0"],["antimony 122","name:antimony-122"],["antimony 124","name:antimony-124"],["antimony 125","name:antimony-125"],["antimony oxide sb2o4","cas:1332-81-6"],["antimony oxide sb2o5","cas:1314-60-9"],["antimony pentoxide","cas:1314-60-9"],["antimony tetroxide","cas:1332-81-6"],["antimony total","name:antimony, total"],["antimony trioxide","cas:1309-64-4"]],"match":"exact+contains","order":"The place's own instruments first, then each place above it, each in its register's order; rows for a marine receiving water after the rest, as none of the place's own rows names a marine, salt, estuarine, coastal or ocean water"},"total":389,"offset":0,"returned":50,"next_offset":50,"rows":[{"id":"25a52f38fbc70e4f","parameter":"Antimony","value":"6.0 (chronic)","value_num":6,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-36-0","place":["US-CO"],"conditions":["receiving_water is freshwater","a segment whose standards adopt the table value standards (TVS) of Table III (segment tables in Regulations 32 to 38)","segments classified for domestic water supply"],"cite":{"instrument":"us_co_wqs","title":"Colorado Regulation No. 31 (5 CCR 1002-31) Basic Standards and Methodologies for Surface Water: Table B organic chemicals, Table III metals, Table IV metals at selected hardness","issuer":"State of Colorado, Water Quality Control Commission (Department of Public Health and Environment)","edition":"5 CCR 1002-31 effective December 31, 2024 (adopted August 21, 2024), the Secretary of State's official PDF; US EPA posts the same compilation in effect for CWA purposes (cover January 28, 2025: no action on the phased TN/TP provisions only)","source_url":"https://www.coloradosos.gov/CCR/GenerateRulePdf.do?ruleVersionId=11749&fileName=5%20CCR%201002-31","source_sha256":"af2f5ee73f74fa7f1cb168059b88977c13a07369665f6dc9b96633ff189855f9","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"5 CCR 1002-31 31.16 Table III","page":58,"quote":null}},{"id":"257d316abd9a83a1","parameter":"Antimony","value":"5.6","value_num":5.6,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-36-0","place":["US-CO"],"conditions":["receiving_water is freshwater","a segment whose standards adopt the table value standards (TVS) of Table III (segment tables in Regulations 32 to 38)","segments classified for Class 1 or 2 aquatic life with water supply"],"cite":{"instrument":"us_co_wqs","title":"Colorado Regulation No. 31 (5 CCR 1002-31) Basic Standards and Methodologies for Surface Water: Table B organic chemicals, Table III metals, Table IV metals at selected hardness","issuer":"State of Colorado, Water Quality Control Commission (Department of Public Health and Environment)","edition":"5 CCR 1002-31 effective December 31, 2024 (adopted August 21, 2024), the Secretary of State's official PDF; US EPA posts the same compilation in effect for CWA purposes (cover January 28, 2025: no action on the phased TN/TP provisions only)","source_url":"https://www.coloradosos.gov/CCR/GenerateRulePdf.do?ruleVersionId=11749&fileName=5%20CCR%201002-31","source_sha256":"af2f5ee73f74fa7f1cb168059b88977c13a07369665f6dc9b96633ff189855f9","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"5 CCR 1002-31 31.16 Table III","page":58,"quote":null}},{"id":"bd91ca6ff54b5871","parameter":"Antimony","value":"640","value_num":640,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7440-36-0","place":["US-CO"],"conditions":["receiving_water is freshwater","a segment whose standards adopt the table value standards (TVS) of Table III (segment tables in Regulations 32 to 38)","segments classified for Class 1 or 2 aquatic life without water supply"],"cite":{"instrument":"us_co_wqs","title":"Colorado Regulation No. 31 (5 CCR 1002-31) Basic Standards and Methodologies for Surface Water: Table B organic chemicals, Table III metals, Table IV metals at selected hardness","issuer":"State of Colorado, Water Quality Control Commission (Department of Public Health and Environment)","edition":"5 CCR 1002-31 effective December 31, 2024 (adopted August 21, 2024), the Secretary of State's official PDF; US EPA posts the same compilation in effect for CWA purposes (cover January 28, 2025: no action on the phased TN/TP provisions only)","source_url":"https://www.coloradosos.gov/CCR/GenerateRulePdf.do?ruleVersionId=11749&fileName=5%20CCR%201002-31","source_sha256":"af2f5ee73f74fa7f1cb168059b88977c13a07369665f6dc9b96633ff189855f9","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"5 CCR 1002-31 31.16 Table III","page":58,"quote":null}},{"id":"711be53dfd38af1e","parameter":"Antimony","value":"1.9","value_num":1.9,"unit":"mg/L","statistic":"composite","direction":"max","kind":"limit","medium":"product","level":"national","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["(a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS."],"cite":{"instrument":"us_40cfr268_48","title":"40 CFR 268.48 — Universal treatment standards: Table UTS, wastewater and nonwastewater treatment standards for the hazardous constituents of land-disposal-restricted wastes","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"eCFR, 40 CFR 268.48 as of 2026-10-13 (title 40 up to date as of that day; source note: 59 FR 48103, Sept. 19, 1994, as last amended at 76 FR 34156, June 13, 2011)","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-13/title-40.xml?part=268&section=268.48","source_sha256":"70b2e58a6b1e228e2c204acc69b69fab0d5a0347e35d569959073c3dc3ee4adb","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 268.48, Table UTS, Inorganic Constituents, wastewater standard","page":null,"quote":"Antimony 7440-36-0 1.9 1.15 mg/l TCLP"}},{"id":"2273032396effd79","parameter":"Antimony","value":"1.15 mg/l TCLP","value_num":1.15,"unit":"mg/L TCLP","statistic":"instant","direction":"max","kind":"limit","medium":"leachate","level":"national","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["(a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS."],"cite":{"instrument":"us_40cfr268_48","title":"40 CFR 268.48 — Universal treatment standards: Table UTS, wastewater and nonwastewater treatment standards for the hazardous constituents of land-disposal-restricted wastes","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"eCFR, 40 CFR 268.48 as of 2026-10-13 (title 40 up to date as of that day; source note: 59 FR 48103, Sept. 19, 1994, as last amended at 76 FR 34156, June 13, 2011)","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-13/title-40.xml?part=268&section=268.48","source_sha256":"70b2e58a6b1e228e2c204acc69b69fab0d5a0347e35d569959073c3dc3ee4adb","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 268.48, Table UTS, Inorganic Constituents, nonwastewater standard","page":null,"quote":"Antimony 7440-36-0 1.9 1.15 mg/l TCLP"}},{"id":"7add8daef8f889b6","parameter":"Antimony (T)","value":"0.0086","value_num":0.0086,"unit":"Kg/kkg (or pounds per/1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart BN—Sodium Chlorate Production Subcategory","existing sources (BPT)","table: Subpart BN—Sodium Chlorate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 415.662 (BPT)","page":null,"quote":"Antimony (T) 0.0086 0.0043"}},{"id":"fe8d182baa5d20b7","parameter":"Antimony (T)","value":"0.0043","value_num":0.0043,"unit":"Kg/kkg (or pounds per/1,000 lb) of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart BN—Sodium Chlorate Production Subcategory","existing sources (BPT)","table: Subpart BN—Sodium Chlorate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 415.662 (BPT)","page":null,"quote":"Antimony (T) 0.0086 0.0043"}},{"id":"58b30ca6cea6e5b7","parameter":"Antimony (T)","value":"0.0043","value_num":0.0043,"unit":"Kg/kkg (or pounds per/1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart BN—Sodium Chlorate Production Subcategory","existing sources (BAT)","table: Subpart BN—Sodium Chlorate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 415.663 (BAT)","page":null,"quote":"Antimony (T) 0.0043 0.0022"}},{"id":"b86a5f26374d9f13","parameter":"Antimony (T)","value":"0.0022","value_num":0.0022,"unit":"Kg/kkg (or pounds per/1,000 lb) of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart BN—Sodium Chlorate Production Subcategory","existing sources (BAT)","table: Subpart BN—Sodium Chlorate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 415.663 (BAT)","page":null,"quote":"Antimony (T) 0.0043 0.0022"}},{"id":"6bff6df73c50deee","parameter":"Antimony (T)","value":"0.0043","value_num":0.0043,"unit":"Kg/kkg (or pounds per/1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart BN—Sodium Chlorate Production Subcategory","new sources (NSPS)","Any new source subject to this subpart must achieve the following new source performance standards (NSPS):","table: Subpart BN—Sodium Chlorate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 415.665 (NSPS)","page":null,"quote":"Antimony (T) 0.0043 0.0022"}},{"id":"14b494880b069fcd","parameter":"Antimony (T)","value":"0.0022","value_num":0.0022,"unit":"Kg/kkg (or pounds per/1,000 lb) of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart BN—Sodium Chlorate Production Subcategory","new sources (NSPS)","Any new source subject to this subpart must achieve the following new source performance standards (NSPS):","table: Subpart BN—Sodium Chlorate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 415.665 (NSPS)","page":null,"quote":"Antimony (T) 0.0043 0.0022"}},{"id":"6c770df37bad51bf","parameter":"Antimony (T)","value":"1.6","value_num":1.6,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart BN—Sodium Chlorate Production Subcategory","new sources (PSNS)","table: Subpart BN—Sodium Chlorate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 415.666 (PSNS)","page":null,"quote":"Antimony (T) 1.6 0.8"}},{"id":"5fb8a9dade015558","parameter":"Antimony (T)","value":"0.8","value_num":0.8,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart BN—Sodium Chlorate Production Subcategory","new sources (PSNS)","table: Subpart BN—Sodium Chlorate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 415.666 (PSNS)","page":null,"quote":"Antimony (T) 1.6 0.8"}},{"id":"f9911a04c1d453ec","parameter":"Antimony","value":".263","value_num":0.263,"unit":"mg/kg (pounds per million pounds) of paste produced","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(a) Subpart B—Anode and Cathode Paste Plant Wet Air Pollution Control","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Antimony .263 .117"}},{"id":"353ee4f5188cb809","parameter":"Antimony","value":".117","value_num":0.117,"unit":"mg/kg (pounds per million pounds) of paste produced","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(a) Subpart B—Anode and Cathode Paste Plant Wet Air Pollution Control","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Antimony .263 .117"}},{"id":"63c1c5b54fcefc78","parameter":"Antimony","value":".403","value_num":0.403,"unit":"mg/kg (pounds per million pounds) of anodes cast","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(b) Subpart (B)—Anode Contact Cooling and Briquette Quenching.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Antimony .403 .180"}},{"id":"1a59da072faf478d","parameter":"Antimony","value":".180","value_num":0.18,"unit":"mg/kg (pounds per million pounds) of anodes cast","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(b) Subpart (B)—Anode Contact Cooling and Briquette Quenching.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Antimony .403 .180"}},{"id":"22bfb365def9072a","parameter":"Antimony","value":"8.346","value_num":8.346,"unit":"mg/kg (pounds per million pounds) of anodes baked","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(c) Subpart (B)—Anode Bake Plant Wet Air Pollution Control (Closed Top Ring Furnace).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Antimony 8.346 3.719"}},{"id":"3ff96851c03695ae","parameter":"Antimony","value":"3.719","value_num":3.719,"unit":"mg/kg (pounds per million pounds) of anodes baked","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(c) Subpart (B)—Anode Bake Plant Wet Air Pollution Control (Closed Top Ring Furnace).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Antimony 8.346 3.719"}},{"id":"870730e69f491886","parameter":"Antimony","value":".097","value_num":0.097,"unit":"mg/kg (pounds per million pounds) of anodes baked","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(d) Subpart B—Anode Bake Plant Wet Air Pollution Control (Open Top Ring Furnace With Spray Tower Only).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Antimony .097 .043"}},{"id":"9020dce67fcefda6","parameter":"Antimony","value":".043","value_num":0.043,"unit":"mg/kg (pounds per million pounds) of anodes baked","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(d) Subpart B—Anode Bake Plant Wet Air Pollution Control (Open Top Ring Furnace With Spray Tower Only).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Antimony .097 .043"}},{"id":"e7974dfb20c4f22f","parameter":"Antimony","value":"1.409","value_num":1.409,"unit":"mg/kg (pounds per million pounds) of anodes baked","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(e) Subpart B—Anode Bake Plant Wet Air Pollution Control (Open Top Ring Furnace With Wet Electrostatic Precipitator and Spray Tower).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Antimony 1.409 .628"}},{"id":"8fb82b413d0dd03a","parameter":"Antimony","value":".628","value_num":0.628,"unit":"mg/kg (pounds per million pounds) of anodes baked","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(e) Subpart B—Anode Bake Plant Wet Air Pollution Control (Open Top Ring Furnace With Wet Electrostatic Precipitator and Spray Tower).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Antimony 1.409 .628"}},{"id":"4a83ccb0c0742da1","parameter":"Antimony","value":"2.197","value_num":2.197,"unit":"mg/kg (pounds per million pounds) of anodes baked","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(f) Subpart B—Anode Bake Plant Wet Air Pollution Control (Tunnel Kiln).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Antimony 2.197 .979"}},{"id":"a5ee2ff16121458c","parameter":"Antimony","value":".979","value_num":0.979,"unit":"mg/kg (pounds per million pounds) of anodes baked","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(f) Subpart B—Anode Bake Plant Wet Air Pollution Control (Tunnel Kiln).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Antimony 2.197 .979"}},{"id":"b1bbefbae593f5e9","parameter":"Antimony","value":"420.400","value_num":420.4,"unit":"mg/kg (pounds per million pounds) of cryolite recovered","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(g) Subpart B—Cathode Reprocessing (Operated With Dry Potline Scrubbing and Not Commingled With Other Process or Nonprocess Waters).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Antimony 420.400 189.200"}},{"id":"3a309e11e6e23668","parameter":"Antimony","value":"189.200","value_num":189.2,"unit":"mg/kg (pounds per million pounds) of cryolite recovered","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(g) Subpart B—Cathode Reprocessing (Operated With Dry Potline Scrubbing and Not Commingled With Other Process or Nonprocess Waters).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Antimony 420.400 189.200"}},{"id":"cb2ec0d7ae2c3c49","parameter":"Antimony","value":"67.610","value_num":67.61,"unit":"mg/kg (pounds per million pounds) of cryolite recovered","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(h) Subpart B—Cathode Reprocessing (Operated With Dry Potline Scrubbing and Commingled With Other Process or Nonprocess Waters).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Antimony 67.610 30.120"}},{"id":"7fecb6482c2f3aae","parameter":"Antimony","value":"30.120","value_num":30.12,"unit":"mg/kg (pounds per million pounds) of cryolite recovered","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(h) Subpart B—Cathode Reprocessing (Operated With Dry Potline Scrubbing and Commingled With Other Process or Nonprocess Waters).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Antimony 67.610 30.120"}},{"id":"33ca20f21cb059f4","parameter":"Antimony","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of cryolite recovered","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(i) Subpart B—Cathode Reprocessing (Operated With Wet Potline Scrubbing).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Antimony .000 .000"}},{"id":"3c88267964bc7d8d","parameter":"Antimony","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of cryolite recovered","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(i) Subpart B—Cathode Reprocessing (Operated With Wet Potline Scrubbing).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Antimony .000 .000"}},{"id":"8002e85b488b6622","parameter":"Antimony","value":"1.618","value_num":1.618,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(j) Subpart B—Potline Wet Air Pollution Control (Operated Without Cathode Reprocessing).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Antimony 1.618 .721"}},{"id":"f9157732bff13a5c","parameter":"Antimony","value":".721","value_num":0.721,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(j) Subpart B—Potline Wet Air Pollution Control (Operated Without Cathode Reprocessing).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Antimony 1.618 .721"}},{"id":"3719698fb6531726","parameter":"Antimony","value":"10.060","value_num":10.06,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(k) Subpart B—Potline Wet Air Pollution Control (Operated With Cathode Reprocessing and Not Commingled With Other Process or Nonprocess Waters).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Antimony 10.060 4.525"}},{"id":"c52efb82ea04c3e5","parameter":"Antimony","value":"4.525","value_num":4.525,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(k) Subpart B—Potline Wet Air Pollution Control (Operated With Cathode Reprocessing and Not Commingled With Other Process or Nonprocess Waters).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Antimony 10.060 4.525"}},{"id":"21f4d963a31a3055","parameter":"Antimony","value":"1.618","value_num":1.618,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(l) Potline Wet Air Pollution Control Cooperated With Cathode Reprocessing and Commingled With Other Process or Nonprocess Wastewaters).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Antimony 1.618 .721"}},{"id":"6da834f3e3a9b724","parameter":"Antimony","value":".721","value_num":0.721,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(l) Potline Wet Air Pollution Control Cooperated With Cathode Reprocessing and Commingled With Other Process or Nonprocess Wastewaters).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Antimony 1.618 .721"}},{"id":"70d6d8452814b5b6","parameter":"Antimony","value":"3.204","value_num":3.204,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(m) Subpart B—Potroom Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Antimony 3.204 1.428"}},{"id":"6e66b71fb6103589","parameter":"Antimony","value":"1.428","value_num":1.428,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(m) Subpart B—Potroom Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Antimony 3.204 1.428"}},{"id":"e79e4ba5544cea22","parameter":"Antimony","value":"2.588","value_num":2.588,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(n) Subpart B—Potline SO 2 Emissions Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Antimony 2.588 1.153"}},{"id":"c5e743c0e0393348","parameter":"Antimony","value":"1.153","value_num":1.153,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(n) Subpart B—Potline SO 2 Emissions Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Antimony 2.588 1.153"}},{"id":"488af29a948e546b","parameter":"Antimony","value":"5.036","value_num":5.036,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(o) Subpart B—Degassing Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Antimony 5.036 2.244"}},{"id":"fbe660745a2efee6","parameter":"Antimony","value":"2.244","value_num":2.244,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(o) Subpart B—Degassing Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Antimony 5.036 2.244"}},{"id":"e863b77303cbcfc9","parameter":"Antimony","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(p) Subpart B—Pot Repair and Pot Soaking.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Antimony .000 .000"}},{"id":"bd7f7e048027d92d","parameter":"Antimony","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(p) Subpart B—Pot Repair and Pot Soaking.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Antimony .000 .000"}},{"id":"f5b59181d3f803b9","parameter":"Antimony","value":"2.565","value_num":2.565,"unit":"mg/kg (pound per million pounds) of aluminum product from direct chill casting","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(q) Subpart B—Direct Chill Casting Contact Cooling.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Antimony 2.565 1.143"}},{"id":"ab69df783286a492","parameter":"Antimony","value":"1.143","value_num":1.143,"unit":"mg/kg (pound per million pounds) of aluminum product from direct chill casting","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(q) Subpart B—Direct Chill Casting Contact Cooling.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Antimony 2.565 1.143"}},{"id":"19785c5b9e88cd54","parameter":"Antimony","value":".201","value_num":0.201,"unit":"mg/kg (pound per million pounds) of aluminum product from rod casting","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(r) Subpart B—Continuous Rod Casting Contact Cooling.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Antimony .201 .089"}},{"id":"2a31cbbfa010b72d","parameter":"Antimony","value":".089","value_num":0.089,"unit":"mg/kg (pound per million pounds) of aluminum product from rod casting","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(r) Subpart B—Continuous Rod Casting Contact Cooling.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Antimony .201 .089"}},{"id":"68801f581b72c004","parameter":"Antimony","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of aluminum product from stationary casting or shot casting","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-36-0","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(s) Subpart B—Stationary Casting or Shot Casting Contact Cooling.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Antimony .000 .000"}}],"next":[{"tool":"check_values","says":"Has your user measured this? check_values sets each of their results beside every row held here, with a verdict and the row's cite.","arguments":{"place":"US-CO"},"needs":{"rows":"Your user's measured results, as their table prints them: [{parameter: \"antimony\", value, unit}, ...], any other parameters too."},"post":"/api/v1/check"},{"tool":"read_certificate","says":"Has your user a laboratory certificate? read_certificate reads every row it prints, each with its page, and checks them against these limits.","arguments":{"place":"US-CO"},"needs":{"content_base64":"The laboratory's certificate (PDF) or its XLSX, XLS or CSV export, as base64; or file_url, a public https address of it."},"post":"/api/v1/certificate"}]}