{"query":{"parameter":"amomonia as n","place":"US-IA","medium":null,"statistic":null,"kind":null},"searched":{"places":["US-IA","US"],"parameter_keys":["name:amomonia"],"names_matched":[["amomonia as n","name:amomonia"]],"match":"exact","order":"The place's own instruments first, then each place above it, each in its register's order"},"total":8,"offset":0,"returned":8,"next_offset":null,"rows":[{"id":"2a2d124335268115","parameter":"Amomonia (as N)","value":"102.800","value_num":102.8,"unit":"mg/kg (lb/million lbs) of aluminum demagged","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"name:amomonia","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","existing sources (PSES)","(d) Subpart C—Demagging Wet Air Pollution Control.","table: PSES"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.35 (PSES)","page":null,"quote":"Amomonia (as N) 102.800 45.180"}},{"id":"59f22daef8ae9236","parameter":"Amomonia (as N)","value":"45.180","value_num":45.18,"unit":"mg/kg (lb/million lbs) of aluminum demagged","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"name:amomonia","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","existing sources (PSES)","(d) Subpart C—Demagging Wet Air Pollution Control.","table: PSES"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.35 (PSES)","page":null,"quote":"Amomonia (as N) 102.800 45.180"}},{"id":"aeb4f65bcf6e64ec","parameter":"Amomonia (as N)","value":"8.931","value_num":8.931,"unit":"mg/kg (lb/million lbs) of aluminum cast","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"name:amomonia","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","existing sources (PSES)","(g) Subpart C—Ingot Conveyor Casting Contact Cooling (When Chlorine Demagging Wet Air Pollution Control is Not Practiced On-Site).","table: PSES"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.35 (PSES)","page":null,"quote":"Amomonia (as N) 8.931 3.926"}},{"id":"7f95e62b27ff3c2a","parameter":"Amomonia (as N)","value":"3.926","value_num":3.926,"unit":"mg/kg (lb/million lbs) of aluminum cast","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"name:amomonia","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","existing sources (PSES)","(g) Subpart C—Ingot Conveyor Casting Contact Cooling (When Chlorine Demagging Wet Air Pollution Control is Not Practiced On-Site).","table: PSES"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.35 (PSES)","page":null,"quote":"Amomonia (as N) 8.931 3.926"}},{"id":"4fac61e9fc4445c5","parameter":"Amomonia (as N)","value":"102.800","value_num":102.8,"unit":"mg/kg (lb/million lbs) of aluminum demagged","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"name:amomonia","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","new sources (PSNS)","(d) Subpart C—Demagging Wet Air Pollution Control.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.36 (PSNS)","page":null,"quote":"Amomonia (as N) 102.800 45.180"}},{"id":"5d01510901ff733b","parameter":"Amomonia (as N)","value":"45.180","value_num":45.18,"unit":"mg/kg (lb/million lbs) of aluminum demagged","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"name:amomonia","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","new sources (PSNS)","(d) Subpart C—Demagging Wet Air Pollution Control.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.36 (PSNS)","page":null,"quote":"Amomonia (as N) 102.800 45.180"}},{"id":"b4338fbc337dc9cb","parameter":"Amomonia (as N)","value":"8.931","value_num":8.931,"unit":"mg/kg (lb/million lbs) of aluminum cast","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"name:amomonia","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","new sources (PSNS)","(g) Subpart C—Ingot Conveyor Casting Control Cooling (When Chlorine Demagging Wet Air Pollution Control is Not Practiced On-Site).","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.36 (PSNS)","page":null,"quote":"Amomonia (as N) 8.931 3.926"}},{"id":"7f0dd66fcf081aaa","parameter":"Amomonia (as N)","value":"3.926","value_num":3.926,"unit":"mg/kg (lb/million lbs) of aluminum cast","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"name:amomonia","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","new sources (PSNS)","(g) Subpart C—Ingot Conveyor Casting Control Cooling (When Chlorine Demagging Wet Air Pollution Control is Not Practiced On-Site).","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"unchanged"},"section":"40 CFR 421.36 (PSNS)","page":null,"quote":"Amomonia (as N) 8.931 3.926"}}],"next":[{"tool":"check_values","says":"Has your user measured this? check_values sets each of their results beside every row held here, with a verdict and the row's cite.","arguments":{"place":"US-IA"},"needs":{"rows":"Your user's measured results, as their table prints them: [{parameter: \"amomonia as n\", value, unit}, ...], any other parameters too."},"post":"/api/v1/check"},{"tool":"read_certificate","says":"Has your user a laboratory certificate? read_certificate reads every row it prints, each with its page, and checks them against these limits.","arguments":{"place":"US-IA"},"needs":{"content_base64":"The laboratory's certificate (PDF) or its XLSX, XLS or CSV export, as base64; or file_url, a public https address of it."},"post":"/api/v1/certificate"}]}