{"query":{"parameter":"aluminum","place":"US-TX","medium":null,"statistic":null,"kind":null},"searched":{"places":["US-TX","US"],"parameter_keys":["cas:7429-90-5","cas:139-12-8","cas:1327-41-9","name:aluminum - dissolved","name:aluminum, ionic","cas:13776-88-0","cas:20859-73-8","cas:12736-96-8","name:~aluminum salts of inorganic phosphates","cas:7785-88-8","name:aluminum, total","cas:39148-24-8","cas:7784-30-7","cas:13530-50-2","cas:92203-02-6","cas:10279-59-1","cas:10305-76-7","name:total aluminum","name:total recoverable aluminum","cas:13939-25-8","name:fer, aluminium et composes"],"names_matched":[["aluminum","cas:7429-90-5"],["acetic acid aluminum salt","cas:139-12-8"],["aluminum chloride hydroxide","cas:1327-41-9"],["aluminum dissolved","name:aluminum - dissolved"],["aluminum ionic","name:aluminum, ionic"],["aluminum metaphosphate","cas:13776-88-0"],["aluminum phosphide","cas:20859-73-8"],["aluminum potassium sodium silicate","cas:12736-96-8"],["aluminum salts of inorganic phosphates","name:~aluminum salts of inorganic phosphates"],["aluminum sodium phosphate","cas:7785-88-8"],["aluminum total","name:aluminum, total"],["aluminum tris o ethylphosphonate","cas:39148-24-8"],["metaphosphoric acid hpo3 aluminum salt","cas:13776-88-0"],["phosphoric acid aluminum salt 1 1 aluminum phosphate","cas:7784-30-7"],["phosphoric acid aluminum salt 3 1","cas:13530-50-2"],["phosphoric acid aluminum sodium salt 1 x x sodium aluminum phosphate acidic acidic salp","cas:7785-88-8"],["phosphoric acid reaction products with aluminum hydroxide and chromium oxide cro3","cas:92203-02-6"],["silicic acid aluminum potassium sodium salt","cas:12736-96-8"],["sodium aluminum phosphate anhydrous","cas:10279-59-1"],["sodium aluminum phosphate tetrahydrate","cas:10305-76-7"],["total aluminum","name:total aluminum"],["total recoverable aluminum","name:total recoverable aluminum"],["triphosphoric acid aluminum salt 1 1","cas:13939-25-8"],["triphosphoric acid aluminum salt 1 1 aluminum triphosphate","cas:13939-25-8"],["fer aluminium et composes","name:fer, aluminium et composes","aluminium"],["fer aluminium et composes en fe al","name:fer, aluminium et composes","aluminium"],["triacetate d aluminium","cas:139-12-8","aluminium"]],"match":"exact+contains","order":"The place's own instruments first, then each place above it, each in its register's order","not_sent":{"rows":7,"names":["Fosetyl-AL","~Monoaluminum phosphate"],"says":"7 rows share a parameter key with a longer name holding \"aluminum\" but are printed under names without these words (that key is wider than the name): not sent. Ask for one by its name or CAS number."}},"total":424,"offset":0,"returned":50,"next_offset":50,"rows":[{"id":"689951bb7a61bf18","parameter":"Aluminum","value":"6.5E+04","value_num":65000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7429-90-5","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 1, Residential Soil, TotSoilComb, 0.5 acre source area","page":9,"quote":null}},{"id":"d1667aa7c75b98f9","parameter":"Aluminum","value":"1.7E+05","value_num":170000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7429-90-5","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 1, Residential Soil, GWSoilIng, 0.5 acre source area","page":9,"quote":null}},{"id":"33fab664e355052a","parameter":"Aluminum","value":"1.0E+06","value_num":1000000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7429-90-5","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 1, Residential Soil, GWSoilClass 3, 0.5 acre source area","page":9,"quote":null}},{"id":"7451273f86cee0b5","parameter":"Aluminum","value":"1.4E+03","value_num":1400,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7429-90-5","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 1, Residential Soil, GWSoil for Secondary MCL, 0.5 acre source area","page":9,"quote":null}},{"id":"e19b236a6652625d","parameter":"Aluminum","value":"6.4E+04","value_num":64000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7429-90-5","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 1, Residential Soil, TotSoilComb, 30 acre source area","page":9,"quote":null}},{"id":"53b10a835003f604","parameter":"Aluminum","value":"8.6E+04","value_num":86000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7429-90-5","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 1, Residential Soil, GWSoilIng, 30 acre source area","page":9,"quote":null}},{"id":"8b7fb6b850996f26","parameter":"Aluminum","value":"1.0E+06","value_num":1000000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7429-90-5","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 1, Residential Soil, GWSoilClass 3, 30 acre source area","page":9,"quote":null}},{"id":"39298230a84d697c","parameter":"Aluminum","value":"7.1E+02","value_num":710,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7429-90-5","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 1, Residential Soil, GWSoil for Secondary MCL, 30 acre source area","page":9,"quote":null}},{"id":"f3d96ca284a0f029","parameter":"Aluminum","value":"6.2E+05","value_num":620000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7429-90-5","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 2, Commercial/Industrial Soil, TotSoilComb, 0.5 acre source area","page":24,"quote":null}},{"id":"ee3719bd97fc59d4","parameter":"Aluminum","value":"5.2E+05","value_num":520000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7429-90-5","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 2, Commercial/Industrial Soil, GWSoilIng, 0.5 acre source area","page":24,"quote":null}},{"id":"2a2ef106273acc4b","parameter":"Aluminum","value":"1.0E+06","value_num":1000000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7429-90-5","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 2, Commercial/Industrial Soil, GWSoilClass 3, 0.5 acre source area","page":24,"quote":null}},{"id":"245c4dff74f0b95f","parameter":"Aluminum","value":"1.4E+03","value_num":1400,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7429-90-5","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 0.5 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 2, Commercial/Industrial Soil, GWSoil for Secondary MCL, 0.5 acre source area","page":24,"quote":null}},{"id":"f066280b758326e5","parameter":"Aluminum","value":"5.7E+05","value_num":570000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7429-90-5","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 2, Commercial/Industrial Soil, TotSoilComb, 30 acre source area","page":24,"quote":null}},{"id":"2239ae7df29be408","parameter":"Aluminum","value":"2.6E+05","value_num":260000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7429-90-5","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 2, Commercial/Industrial Soil, GWSoilIng, 30 acre source area","page":24,"quote":null}},{"id":"aea76b9ac7e633fb","parameter":"Aluminum","value":"1.0E+06","value_num":1000000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7429-90-5","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 2, Commercial/Industrial Soil, GWSoilClass 3, 30 acre source area","page":24,"quote":null}},{"id":"69671cbddb3bcbbf","parameter":"Aluminum","value":"7.1E+02","value_num":710,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7429-90-5","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use, 30 acre source area"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 2, Commercial/Industrial Soil, GWSoil for Secondary MCL, 30 acre source area","page":24,"quote":null}},{"id":"d58352ebb109d6f9","parameter":"Aluminum","value":"2.4E+01","value_num":24,"unit":"mg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:7429-90-5","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 3, Groundwater, GWGWIng, Residential","page":39,"quote":null}},{"id":"8a145133ea00688f","parameter":"Aluminum","value":"2.4E+03","value_num":2400,"unit":"mg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:7429-90-5","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","residential land use"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 3, Groundwater, GWGWClass3, Residential","page":39,"quote":null}},{"id":"c83832f34c8db683","parameter":"Aluminum","value":"7.3E+01","value_num":73,"unit":"mg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:7429-90-5","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 3, Groundwater, GWGWIng, Commercial/Industrial","page":39,"quote":null}},{"id":"235c7d7f789d1248","parameter":"Aluminum","value":"7.3E+03","value_num":7300,"unit":"mg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:7429-90-5","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria.","commercial/industrial land use"],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 3, Groundwater, GWGWClass3, Commercial/Industrial","page":39,"quote":null}},{"id":"79f9063f3b2c01b8","parameter":"Aluminum","value":"2.0E-01","value_num":0.2,"unit":"mg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:7429-90-5","place":["US-TX"],"conditions":["1 In accordance with §350.72(b), when establishing Tier 1 PCLs for individual COCs for each of the individual and combined human health exposure pathways, the person must evaluate whether the PCLs need to be adjusted to lower concentrations to meet the cumulative carcinogenic risk level and hazard index criteria specified in §350.72(c). For COCs which exhibit both carcinogenic and noncarcinogenic characteristics, they shall be evaluated as both a carcinogen and noncarcinogen when determining whether the PCL established for an individual COC for each of the individual and combined human health exposure pathways needs to be adjusted to a lower concentration to meet the cumulative risk and hazard criteria. The person shall then use the lower of the carcinogenic or noncarcinogenic PCL as the Tier 1 human health PCL. In other words, the Tier 1 PCLs provided in this table for an individual COC should not be used as the final Tier 1 human health PCL for any of the individual or combined exposure pathways in cases where there are more than 10 carcinogenic and/or more than 10 noncarcinogenic COCs within a source medium unless it can be demonstrated that further downward adjustment is not necessary to meet the cumulative risk and hazard criteria."],"cite":{"instrument":"us_tx_trrp_pcl","title":"Texas Risk Reduction Program (30 TAC Chapter 350): Tier 1 protective concentration levels — Table 1 Residential Soil, Table 2 Commercial/Industrial Soil, Table 3 Groundwater (residential and commercial/industrial)","issuer":"Texas Commission on Environmental Quality (TCEQ)","edition":"TRRP Tier 1 PCL tables, Last Revised: February 6, 2025 (TCEQ, PDF version)","source_url":"https://www.tceq.texas.gov/downloads/remediation/trrp/2025-pcl-tables-6-february-2025-final.pdf","source_sha256":"fb90ae0c95044f80cf21c83087ddbdc18ceee259ef8a6531887cc5c454d67686","fetched_at":"2026-10-15","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"TRRP Table 3, Groundwater, Secondary MCL","page":39,"quote":null}},{"id":"fd0f2206f1f3a803","parameter":"Aluminum","value":"991w","value_num":991,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:7429-90-5","place":["US-TX"],"conditions":["receiving_water is freshwater","water in the state; acute criteria outside zones of initial dilution, chronic criteria in water with an aquatic life use of limited or greater, outside mixing zones and above critical low flow (30 TAC §307.6(c)(6))"],"cite":{"instrument":"us_tx_wqs","title":"Texas Surface Water Quality Standards, 30 TAC Chapter 307 (2022): §307.6 Table 1 aquatic life (freshwater and saltwater acute/chronic) and Table 2 human health; §307.7 Table 3 dissolved oxygen","issuer":"State of Texas, Texas Commission on Environmental Quality (TCEQ)","edition":"2022 Texas Surface Water Quality Standards (Rule Project No. 2020-014-307-OW), effective June 27, 2025, as US EPA posts them (cover dated July 1, 2025) with what EPA has approved for CWA purposes","source_url":"https://www.epa.gov/system/files/documents/2023-12/txwqs-2022.pdf","source_sha256":"88ff93dcfb277feec248541b2aa9a0f01cd3a747cda6e03d958344ee4a34ce5e","fetched_at":"2026-10-14","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"30 TAC §307.6(c) Table 1","page":36,"quote":null}},{"id":"6417c367198e13ad","parameter":"Aluminum","value":".831","value_num":0.831,"unit":"mg/kg (pounds per million pounds) of paste produced","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(a) Subpart B—Anode and Cathode Paste Plant Wet Air Pollution Control","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum .831 .369"}},{"id":"0c254be0e5ee02e5","parameter":"Aluminum","value":".369","value_num":0.369,"unit":"mg/kg (pounds per million pounds) of paste produced","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(a) Subpart B—Anode and Cathode Paste Plant Wet Air Pollution Control","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum .831 .369"}},{"id":"8ad6d4255118afb7","parameter":"Aluminum","value":"1.277","value_num":1.277,"unit":"mg/kg (pounds per million pounds) of anodes cast","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(b) Subpart (B)—Anode Contact Cooling and Briquette Quenching.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 1.277 .566"}},{"id":"91260c4efefe3f85","parameter":"Aluminum","value":".566","value_num":0.566,"unit":"mg/kg (pounds per million pounds) of anodes cast","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(b) Subpart (B)—Anode Contact Cooling and Briquette Quenching.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 1.277 .566"}},{"id":"9d71ef0192a8392e","parameter":"Aluminum","value":"26.420","value_num":26.42,"unit":"mg/kg (pounds per million pounds) of anodes baked","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(c) Subpart (B)—Anode Bake Plant Wet Air Pollution Control (Closed Top Ring Furnace).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 26.420 11.720"}},{"id":"cf103a9ce09caf36","parameter":"Aluminum","value":"11.720","value_num":11.72,"unit":"mg/kg (pounds per million pounds) of anodes baked","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(c) Subpart (B)—Anode Bake Plant Wet Air Pollution Control (Closed Top Ring Furnace).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 26.420 11.720"}},{"id":"a0ffda8996693367","parameter":"Aluminum","value":".306","value_num":0.306,"unit":"mg/kg (pounds per million pounds) of anodes baked","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(d) Subpart B—Anode Bake Plant Wet Air Pollution Control (Open Top Ring Furnace With Spray Tower Only).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum .306 .136"}},{"id":"119d9fe26a8b85f2","parameter":"Aluminum","value":".136","value_num":0.136,"unit":"mg/kg (pounds per million pounds) of anodes baked","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(d) Subpart B—Anode Bake Plant Wet Air Pollution Control (Open Top Ring Furnace With Spray Tower Only).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum .306 .136"}},{"id":"ed78aa40eaaaf1f8","parameter":"Aluminum","value":"4.461","value_num":4.461,"unit":"mg/kg (pounds per million pounds) of anodes baked","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(e) Subpart B—Anode Bake Plant Wet Air Pollution Control (Open Top Ring Furnace With Wet Electrostatic Precipitator and Spray Tower).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 4.461 1.979"}},{"id":"6c15c2aa2071ac07","parameter":"Aluminum","value":"1.979","value_num":1.979,"unit":"mg/kg (pounds per million pounds) of anodes baked","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(e) Subpart B—Anode Bake Plant Wet Air Pollution Control (Open Top Ring Furnace With Wet Electrostatic Precipitator and Spray Tower).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 4.461 1.979"}},{"id":"09196720123d5a14","parameter":"Aluminum","value":"6.953","value_num":6.953,"unit":"mg/kg (pounds per million pounds) of anodes baked","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(f) Subpart B—Anode Bake Plant Wet Air Pollution Control (Tunnel Kiln).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 6.953 3.084"}},{"id":"ee6d11049e6fafa4","parameter":"Aluminum","value":"3.084","value_num":3.084,"unit":"mg/kg (pounds per million pounds) of anodes baked","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(f) Subpart B—Anode Bake Plant Wet Air Pollution Control (Tunnel Kiln).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 6.953 3.084"}},{"id":"e56df52947caa9b5","parameter":"Aluminum","value":"273.200","value_num":273.2,"unit":"mg/kg (pounds per million pounds) of cryolite recovered","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(g) Subpart B—Cathode Reprocessing (Operated With Dry Potline Scrubbing and Not Commingled With Other Process or Nonprocess Waters).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 273.200 122.600"}},{"id":"f2fb9be480698ad4","parameter":"Aluminum","value":"122.600","value_num":122.6,"unit":"mg/kg (pounds per million pounds) of cryolite recovered","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(g) Subpart B—Cathode Reprocessing (Operated With Dry Potline Scrubbing and Not Commingled With Other Process or Nonprocess Waters).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 273.200 122.600"}},{"id":"1dc8e6e54e4f0559","parameter":"Aluminum","value":"214.000","value_num":214,"unit":"mg/kg (pounds per million pounds) of cryolite recovered","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(h) Subpart B—Cathode Reprocessing (Operated With Dry Potline Scrubbing and Commingled With Other Process or Nonprocess Waters).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 214.000 94.930"}},{"id":"88f332a67dbe4506","parameter":"Aluminum","value":"94.930","value_num":94.93,"unit":"mg/kg (pounds per million pounds) of cryolite recovered","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(h) Subpart B—Cathode Reprocessing (Operated With Dry Potline Scrubbing and Commingled With Other Process or Nonprocess Waters).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 214.000 94.930"}},{"id":"b8ec79ce586c54dc","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of cryolite recovered","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(i) Subpart B—Cathode Reprocessing (Operated With Wet Potline Scrubbing).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum .000 .000"}},{"id":"868e17fcf5cc32bf","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of cryolite recovered","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(i) Subpart B—Cathode Reprocessing (Operated With Wet Potline Scrubbing).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum .000 .000"}},{"id":"752d0dbda3a752d1","parameter":"Aluminum","value":"5.120","value_num":5.12,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(j) Subpart B—Potline Wet Air Pollution Control (Operated Without Cathode Reprocessing).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 5.120 2.271"}},{"id":"d5c6a515516f6e53","parameter":"Aluminum","value":"2.271","value_num":2.271,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(j) Subpart B—Potline Wet Air Pollution Control (Operated Without Cathode Reprocessing).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 5.120 2.271"}},{"id":"9a042b1e59b2f62b","parameter":"Aluminum","value":"6.537","value_num":6.537,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(k) Subpart B—Potline Wet Air Pollution Control (Operated With Cathode Reprocessing and Not Commingled With Other Process or Nonprocess Waters).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 6.537 2.933"}},{"id":"7daec4b785ea9b33","parameter":"Aluminum","value":"2.933","value_num":2.933,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(k) Subpart B—Potline Wet Air Pollution Control (Operated With Cathode Reprocessing and Not Commingled With Other Process or Nonprocess Waters).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 6.537 2.933"}},{"id":"8c1a646117c0e71b","parameter":"Aluminum","value":"5.120","value_num":5.12,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(l) Potline Wet Air Pollution Control Cooperated With Cathode Reprocessing and Commingled With Other Process or Nonprocess Wastewaters).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 5.120 2.271"}},{"id":"2836498e56ba8e94","parameter":"Aluminum","value":"2.271","value_num":2.271,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(l) Potline Wet Air Pollution Control Cooperated With Cathode Reprocessing and Commingled With Other Process or Nonprocess Wastewaters).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 5.120 2.271"}},{"id":"710bcff102b223c5","parameter":"Aluminum","value":"10.140","value_num":10.14,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(m) Subpart B—Potroom Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 10.140 4.499"}},{"id":"152fa4844705512e","parameter":"Aluminum","value":"4.499","value_num":4.499,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(m) Subpart B—Potroom Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 10.140 4.499"}},{"id":"f267cfe14cc9d0a1","parameter":"Aluminum","value":"8.194","value_num":8.194,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(n) Subpart B—Potline SO 2 Emissions Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 8.194 3.634"}},{"id":"69fd4d4100461a3b","parameter":"Aluminum","value":"3.634","value_num":3.634,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(n) Subpart B—Potline SO 2 Emissions Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-10-15","status":"not verified"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 8.194 3.634"}}],"next":[{"tool":"check_values","says":"Has your user measured this? check_values sets each of their results beside every row held here, with a verdict and the row's cite.","arguments":{"place":"US-TX"},"needs":{"rows":"Your user's measured results, as their table prints them: [{parameter: \"aluminum\", value, unit}, ...], any other parameters too."},"post":"/api/v1/check"},{"tool":"read_certificate","says":"Has your user a laboratory certificate? read_certificate reads every row it prints, each with its page, and checks them against these limits.","arguments":{"place":"US-TX"},"needs":{"content_base64":"The laboratory's certificate (PDF) or its XLSX, XLS or CSV export, as base64; or file_url, a public https address of it."},"post":"/api/v1/certificate"}]}