{"query":{"parameter":"fluoride","place":"US-FL","medium":null,"statistic":null,"kind":null},"searched":{"places":["US-FL","US"],"parameter_keys":["cas:16984-48-8","cas:7681-49-4","cas:7782-41-4","name:fluoride @ 90°f","cas:7664-39-3","name:fluorures totaux"],"names_matched":[["fluoride","cas:16984-48-8"],["fluoride","cas:7681-49-4"],["fluoride","cas:7782-41-4"],["fluoride 90 f","name:fluoride @ 90°f"],["hydrogen fluoride","cas:7664-39-3"],["fluor und seine gasformigen anorganischen verbindungen angegeben als fluorwasserstoff","cas:7664-39-3","fluor"],["fluor und seine gasformigen verbindungen angegeben als fluorwasserstoff","cas:7664-39-3","fluor"],["fluorwasserstoff und gasformige anorganische fluorverbindungen angegeben als fluor","cas:7664-39-3","fluor"],["fluorides as hf","cas:7664-39-3","fluorides"],["fluorides as hf gaseous growing season","cas:7664-39-3","fluorides"],["fluorides as hf total growing season","cas:7664-39-3","fluorides"],["fluorides as hf total non growing season","cas:7664-39-3","fluorides"],["gaseous fluorides expressed as hf","cas:7664-39-3","fluorides"],["fluorures totaux","name:fluorures totaux","fluorures"],["fluorures totaux f","name:fluorures totaux","fluorures"]],"match":"exact+contains","order":"The place's own instruments first, then each place above it, each in its register's order"},"total":1576,"offset":0,"returned":200,"next_offset":200,"permits_over":{"state":"FL","parameter":"fluoride","permits":1,"list":"https://passage-data.com/api/v1/permits?state=FL&parameter=fluoride"},"rows":[{"id":"27dc411bf554edd0","parameter":"Fluoride","value":"< 1.5","value_num":1.5,"unit":"mg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:16984-48-8","place":["US-FL"],"conditions":["receiving_water is freshwater","Class I, potable water supplies (waters listed by name in 62-302.400, F.A.C.)"],"cite":{"instrument":"us_fl_wqs","title":"F.A.C. 62-302.530 Table: Surface Water Quality Criteria (Florida) — Class I, II, III fresh, III marine and IV criteria","issuer":"State of Florida, Department of Environmental Protection (Environmental Regulation Commission)","edition":"Chapter 62-302, F.A.C., as US EPA posts it in effect for Clean Water Act purposes; 62-302.530 amended through 11-25-25 (its history note, p. 45); EPA's re-posting of 2026-10-05 (PDF CreationDate), fetched 2026-10-15","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/fl_section62-302.pdf","source_sha256":"9865f1a6486a9332278c619fbcd71dc9f4f19af10e39576eea8ae900136aa284","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"F.A.C. 62-302.530(32)","page":35,"quote":null}},{"id":"48bdfe9f4dfd20e4","parameter":"Fluoride","value":"< 1.5","value_num":1.5,"unit":"mg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:16984-48-8","place":["US-FL"],"conditions":["receiving_water is marine","Class II, shellfish propagation or harvesting (waters listed by name in 62-302.400, F.A.C.)"],"cite":{"instrument":"us_fl_wqs","title":"F.A.C. 62-302.530 Table: Surface Water Quality Criteria (Florida) — Class I, II, III fresh, III marine and IV criteria","issuer":"State of Florida, Department of Environmental Protection (Environmental Regulation Commission)","edition":"Chapter 62-302, F.A.C., as US EPA posts it in effect for Clean Water Act purposes; 62-302.530 amended through 11-25-25 (its history note, p. 45); EPA's re-posting of 2026-10-05 (PDF CreationDate), fetched 2026-10-15","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/fl_section62-302.pdf","source_sha256":"9865f1a6486a9332278c619fbcd71dc9f4f19af10e39576eea8ae900136aa284","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"F.A.C. 62-302.530(32)","page":35,"quote":null}},{"id":"00d9f4d6f633764b","parameter":"Fluoride","value":"< 10.0","value_num":10,"unit":"mg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:16984-48-8","place":["US-FL"],"conditions":["receiving_water is freshwater","Class III and Class III-Limited, predominantly fresh waters (every Florida surface water not listed in 62-302.400, F.A.C., is Class III)"],"cite":{"instrument":"us_fl_wqs","title":"F.A.C. 62-302.530 Table: Surface Water Quality Criteria (Florida) — Class I, II, III fresh, III marine and IV criteria","issuer":"State of Florida, Department of Environmental Protection (Environmental Regulation Commission)","edition":"Chapter 62-302, F.A.C., as US EPA posts it in effect for Clean Water Act purposes; 62-302.530 amended through 11-25-25 (its history note, p. 45); EPA's re-posting of 2026-10-05 (PDF CreationDate), fetched 2026-10-15","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/fl_section62-302.pdf","source_sha256":"9865f1a6486a9332278c619fbcd71dc9f4f19af10e39576eea8ae900136aa284","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"F.A.C. 62-302.530(32)","page":35,"quote":null}},{"id":"7d08c75ac02e6b24","parameter":"Fluoride","value":"< 5.0","value_num":5,"unit":"mg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:16984-48-8","place":["US-FL"],"conditions":["receiving_water is marine","Class III and Class III-Limited, predominantly marine waters (every Florida surface water not listed in 62-302.400, F.A.C., is Class III)"],"cite":{"instrument":"us_fl_wqs","title":"F.A.C. 62-302.530 Table: Surface Water Quality Criteria (Florida) — Class I, II, III fresh, III marine and IV criteria","issuer":"State of Florida, Department of Environmental Protection (Environmental Regulation Commission)","edition":"Chapter 62-302, F.A.C., as US EPA posts it in effect for Clean Water Act purposes; 62-302.530 amended through 11-25-25 (its history note, p. 45); EPA's re-posting of 2026-10-05 (PDF CreationDate), fetched 2026-10-15","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/fl_section62-302.pdf","source_sha256":"9865f1a6486a9332278c619fbcd71dc9f4f19af10e39576eea8ae900136aa284","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"F.A.C. 62-302.530(32)","page":35,"quote":null}},{"id":"b2c257dd60821186","parameter":"Fluoride","value":"< 10.0","value_num":10,"unit":"mg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:16984-48-8","place":["US-FL"],"conditions":["receiving_water is freshwater","Class IV, agricultural water supplies (waters listed by name in 62-302.400, F.A.C.)"],"cite":{"instrument":"us_fl_wqs","title":"F.A.C. 62-302.530 Table: Surface Water Quality Criteria (Florida) — Class I, II, III fresh, III marine and IV criteria","issuer":"State of Florida, Department of Environmental Protection (Environmental Regulation Commission)","edition":"Chapter 62-302, F.A.C., as US EPA posts it in effect for Clean Water Act purposes; 62-302.530 amended through 11-25-25 (its history note, p. 45); EPA's re-posting of 2026-10-05 (PDF CreationDate), fetched 2026-10-15","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/fl_section62-302.pdf","source_sha256":"9865f1a6486a9332278c619fbcd71dc9f4f19af10e39576eea8ae900136aa284","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"F.A.C. 62-302.530(32)","page":35,"quote":null}},{"id":"d77e7e1082d44391","parameter":"Fluoride","value":"2000","value_num":2000,"unit":"µg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:7782-41-4","place":["US-FL"],"conditions":["groundwater (Table I, Groundwater Criteria column)","Note: If more than one contaminant is present at a site, CTLs are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Figure 10 of the February 2005 'Final Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.' However, GCTLs for primary and secondary standards shall not be modified."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"changed","changed_on":"2026-10-16","says":"Source changed on or before 2026-10-16, not yet re-read: these rows are as read from Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'."},"section":"Ch. 62-777 F.A.C. Table I, Groundwater and Surface Water Cleanup Target Levels, Groundwater Criteria (DEP spreadsheet, sheet TTable1, row 278)","page":null,"quote":"row 278: Fluoride | 2000 | 10000 | 5000 | 20000 | -Teeth mottling | 7782-41-4 |  | Secondary Standard | 62-302 | 62-302 |  | Nuisance"}},{"id":"1d12e0978f1fab0a","parameter":"Fluoride","value":"10000","value_num":10000,"unit":"µg/L","direction":"max","kind":"threshold","medium":"surface_water","level":"regional","parameter_key":"cas:7782-41-4","place":["US-FL"],"conditions":["receiving_water is freshwater","freshwater surface water (Table I, Freshwater Surface Water Criteria column)","Note: If more than one contaminant is present at a site, CTLs are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Figure 10 of the February 2005 'Final Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.' However, GCTLs for primary and secondary standards shall not be modified."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"changed","changed_on":"2026-10-16","says":"Source changed on or before 2026-10-16, not yet re-read: these rows are as read from Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'."},"section":"Ch. 62-777 F.A.C. Table I, Groundwater and Surface Water Cleanup Target Levels, Freshwater Surface Water Criteria (DEP spreadsheet, sheet TTable1, row 278)","page":null,"quote":"row 278: Fluoride | 2000 | 10000 | 5000 | 20000 | -Teeth mottling | 7782-41-4 |  | Secondary Standard | 62-302 | 62-302 |  | Nuisance"}},{"id":"fd63395c77c146b0","parameter":"Fluoride","value":"5000","value_num":5000,"unit":"µg/L","direction":"max","kind":"threshold","medium":"surface_water","level":"regional","parameter_key":"cas:7782-41-4","place":["US-FL"],"conditions":["receiving_water is marine","marine surface water (Table I, Marine Surface Water Criteria column)","Note: If more than one contaminant is present at a site, CTLs are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Figure 10 of the February 2005 'Final Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.' However, GCTLs for primary and secondary standards shall not be modified."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"changed","changed_on":"2026-10-16","says":"Source changed on or before 2026-10-16, not yet re-read: these rows are as read from Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'."},"section":"Ch. 62-777 F.A.C. Table I, Groundwater and Surface Water Cleanup Target Levels, Marine Surface Water Criteria (DEP spreadsheet, sheet TTable1, row 278)","page":null,"quote":"row 278: Fluoride | 2000 | 10000 | 5000 | 20000 | -Teeth mottling | 7782-41-4 |  | Secondary Standard | 62-302 | 62-302 |  | Nuisance"}},{"id":"bf2d07671504cc45","parameter":"Fluoride","value":"20000","value_num":20000,"unit":"µg/L","direction":"max","kind":"threshold","medium":"groundwater","level":"regional","parameter_key":"cas:7782-41-4","place":["US-FL"],"conditions":["groundwater of low yield/poor quality (Table I, Groundwater of Low Yield/Poor Quality Criteria column)","Note: If more than one contaminant is present at a site, CTLs are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Figure 10 of the February 2005 'Final Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.' However, GCTLs for primary and secondary standards shall not be modified."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"changed","changed_on":"2026-10-16","says":"Source changed on or before 2026-10-16, not yet re-read: these rows are as read from Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'."},"section":"Ch. 62-777 F.A.C. Table I, Groundwater and Surface Water Cleanup Target Levels, Groundwater of Low Yield/Poor Quality Criteria (DEP spreadsheet, sheet TTable1, row 278)","page":null,"quote":"row 278: Fluoride | 2000 | 10000 | 5000 | 20000 | -Teeth mottling | 7782-41-4 |  | Secondary Standard | 62-302 | 62-302 |  | Nuisance"}},{"id":"9ae2ab919225049b","parameter":"Fluoride","value":"840","value_num":840,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7782-41-4","place":["US-FL"],"conditions":["residential direct exposure (Table II, Direct Exposure - Residential column)","** Direct exposure value based on acute toxicity considerations. This criterion is applicable in scenarios where children might be exposed to soils (e.g. residences, schools, playgrounds)","Note: If more than one contaminant is present at a site, the direct exposure values are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Appendix D 'Draft Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.', dated February 2005."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"changed","changed_on":"2026-10-16","says":"Source changed on or before 2026-10-16, not yet re-read: these rows are as read from Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'."},"section":"Ch. 62-777 F.A.C. Table II, Soil Cleanup Target Levels, Direct Exposure - Residential (DEP spreadsheet, sheet TTable2, row 257)","page":null,"quote":"row 257: Fluoride | -Teeth mottling | 7782-41-4 | 840** | 130000 | 6000 | 30000 | 15000 | 60000"}},{"id":"3226c9ba1fdfc06d","parameter":"Fluoride","value":"130000","value_num":130000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7782-41-4","place":["US-FL"],"conditions":["industrial direct exposure (Table II, Direct Exposure - Industrial column)","Note: If more than one contaminant is present at a site, the direct exposure values are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Appendix D 'Draft Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.', dated February 2005."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"changed","changed_on":"2026-10-16","says":"Source changed on or before 2026-10-16, not yet re-read: these rows are as read from Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'."},"section":"Ch. 62-777 F.A.C. Table II, Soil Cleanup Target Levels, Direct Exposure - Industrial (DEP spreadsheet, sheet TTable2, row 257)","page":null,"quote":"row 257: Fluoride | -Teeth mottling | 7782-41-4 | 840** | 130000 | 6000 | 30000 | 15000 | 60000"}},{"id":"ed764bcd0e491e87","parameter":"Fluoride","value":"6000","value_num":6000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7782-41-4","place":["US-FL"],"conditions":["leachability based on groundwater criteria (Table II, Leachability Based on Groundwater column)","Note: If more than one contaminant is present at a site, the direct exposure values are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Appendix D 'Draft Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.', dated February 2005."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"changed","changed_on":"2026-10-16","says":"Source changed on or before 2026-10-16, not yet re-read: these rows are as read from Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'."},"section":"Ch. 62-777 F.A.C. Table II, Soil Cleanup Target Levels, Leachability Based on Groundwater (DEP spreadsheet, sheet TTable2, row 257)","page":null,"quote":"row 257: Fluoride | -Teeth mottling | 7782-41-4 | 840** | 130000 | 6000 | 30000 | 15000 | 60000"}},{"id":"6bc9d1cac4b2f647","parameter":"Fluoride","value":"30000","value_num":30000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7782-41-4","place":["US-FL"],"conditions":["leachability based on freshwater surface water criteria (Table II, Leachability Based on Freshwater SW column)","Note: If more than one contaminant is present at a site, the direct exposure values are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Appendix D 'Draft Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.', dated February 2005."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"changed","changed_on":"2026-10-16","says":"Source changed on or before 2026-10-16, not yet re-read: these rows are as read from Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'."},"section":"Ch. 62-777 F.A.C. Table II, Soil Cleanup Target Levels, Leachability Based on Freshwater SW (DEP spreadsheet, sheet TTable2, row 257)","page":null,"quote":"row 257: Fluoride | -Teeth mottling | 7782-41-4 | 840** | 130000 | 6000 | 30000 | 15000 | 60000"}},{"id":"2fea7e9533932b2d","parameter":"Fluoride","value":"15000","value_num":15000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7782-41-4","place":["US-FL"],"conditions":["leachability based on marine surface water criteria (Table II, Leachability Based on Marine SW column)","Note: If more than one contaminant is present at a site, the direct exposure values are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Appendix D 'Draft Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.', dated February 2005."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"changed","changed_on":"2026-10-16","says":"Source changed on or before 2026-10-16, not yet re-read: these rows are as read from Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'."},"section":"Ch. 62-777 F.A.C. Table II, Soil Cleanup Target Levels, Leachability Based on Marine SW (DEP spreadsheet, sheet TTable2, row 257)","page":null,"quote":"row 257: Fluoride | -Teeth mottling | 7782-41-4 | 840** | 130000 | 6000 | 30000 | 15000 | 60000"}},{"id":"7211af3c3ace8fb0","parameter":"Fluoride","value":"60000","value_num":60000,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:7782-41-4","place":["US-FL"],"conditions":["leachability based on groundwater of low yield/poor quality criteria (Table II, Leachability based on GW of Low Yield/Poor Quality column)","Note: If more than one contaminant is present at a site, the direct exposure values are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Appendix D 'Draft Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.', dated February 2005."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"changed","changed_on":"2026-10-16","says":"Source changed on or before 2026-10-16, not yet re-read: these rows are as read from Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'."},"section":"Ch. 62-777 F.A.C. Table II, Soil Cleanup Target Levels, Leachability based on GW of Low Yield/Poor Quality (DEP spreadsheet, sheet TTable2, row 257)","page":null,"quote":"row 257: Fluoride | -Teeth mottling | 7782-41-4 | 840** | 130000 | 6000 | 30000 | 15000 | 60000"}},{"id":"90b355b89825f281","parameter":"Fluoride","value":"35","value_num":35,"unit":"mg/L","statistic":"composite","direction":"max","kind":"limit","medium":"product","level":"national","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["(a) Table UTS identifies the hazardous constituents, along with the nonwastewater and wastewater treatment standard levels, that are used to regulate most prohibited hazardous wastes with numerical limits. For determining compliance with treatment standards for underlying hazardous constituents as defined in § 268.2(i), these treatment standards may not be exceeded. Compliance with these treatment standards is measured by an analysis of grab samples, unless otherwise noted in the following Table UTS."],"cite":{"instrument":"us_40cfr268_48","title":"40 CFR 268.48 — Universal treatment standards: Table UTS, wastewater and nonwastewater treatment standards for the hazardous constituents of land-disposal-restricted wastes","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"eCFR, 40 CFR 268.48 as of 2026-10-13 (title 40 up to date as of that day; source note: 59 FR 48103, Sept. 19, 1994, as last amended at 76 FR 34156, June 13, 2011)","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-13/title-40.xml?part=268&section=268.48","source_sha256":"70b2e58a6b1e228e2c204acc69b69fab0d5a0347e35d569959073c3dc3ee4adb","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 268.48, Table UTS, Inorganic Constituents, wastewater standard","page":null,"quote":"Fluoride 5 16984-48-8 35 NA"}},{"id":"5755018f973ffbee","parameter":"Fluoride (T)","value":"6.1","value_num":6.1,"unit":"Kg/kkg (or pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart H—Hydrofluoric Acid Production Subcategory","existing sources (BPT)","table: Subpart H—Hydrofluoric Acid"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.82 (BPT)","page":null,"quote":"Fluoride (T) 6.1 2.9"}},{"id":"c7d32fa29b642d12","parameter":"Fluoride (T)","value":"2.9","value_num":2.9,"unit":"Kg/kkg (or pounds per 1,000 lb) of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart H—Hydrofluoric Acid Production Subcategory","existing sources (BPT)","table: Subpart H—Hydrofluoric Acid"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.82 (BPT)","page":null,"quote":"Fluoride (T) 6.1 2.9"}},{"id":"8aa8fae40c3861ae","parameter":"Fluoride (T)","value":"3.4","value_num":3.4,"unit":"Kg/kkg (or pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart H—Hydrofluoric Acid Production Subcategory","existing sources (BAT)","table: Subpart H—Hydrofluoric Acid"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.83 (BAT)","page":null,"quote":"Fluoride (T) 3.4 1.6"}},{"id":"8d8037e5a3fc8de5","parameter":"Fluoride (T)","value":"1.6","value_num":1.6,"unit":"Kg/kkg (or pounds per 1,000 lb) of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart H—Hydrofluoric Acid Production Subcategory","existing sources (BAT)","table: Subpart H—Hydrofluoric Acid"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.83 (BAT)","page":null,"quote":"Fluoride (T) 3.4 1.6"}},{"id":"944f2f7db3e99413","parameter":"Fluoride (T)","value":"3.4","value_num":3.4,"unit":"Kg/kkg (or pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart H—Hydrofluoric Acid Production Subcategory","new sources (NSPS)","Any new source subject to this subpart must achieve the following new source performance standards (NSPS):","table: Subpart H—Hydrofluoric Acid"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.85 (NSPS)","page":null,"quote":"Fluoride (T) 3.4 1.6"}},{"id":"c97d760f0e4660cf","parameter":"Fluoride (T)","value":"1.6","value_num":1.6,"unit":"Kg/kkg (or pounds per 1,000 lb) of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart H—Hydrofluoric Acid Production Subcategory","new sources (NSPS)","Any new source subject to this subpart must achieve the following new source performance standards (NSPS):","table: Subpart H—Hydrofluoric Acid"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.85 (NSPS)","page":null,"quote":"Fluoride (T) 3.4 1.6"}},{"id":"b8673007a19d77b4","parameter":"Fluoride (T)","value":"100","value_num":100,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart H—Hydrofluoric Acid Production Subcategory","new sources (PSNS)","table: Subpart H—Hydrofluoric Acid"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.86 (PSNS)","page":null,"quote":"Fluoride (T) 100 50"}},{"id":"9bdce9ea67024f50","parameter":"Fluoride (T)","value":"50","value_num":50,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart H—Hydrofluoric Acid Production Subcategory","new sources (PSNS)","table: Subpart H—Hydrofluoric Acid"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.86 (PSNS)","page":null,"quote":"Fluoride (T) 100 50"}},{"id":"c99eee425ed0a18a","parameter":"Fluoride (T)","value":"1.3","value_num":1.3,"unit":"Kg/kkg (or pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart W—Aluminum Fluoride Production Subcategory","existing sources (BPT)","table: Subpart W—Aluminum Fluoride","column: Pollutant or pollutant property"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.232 (BPT)","page":null,"quote":"Fluoride (T) 1.3 0.63"}},{"id":"c50d131c3076009a","parameter":"Fluoride (T)","value":"0.63","value_num":0.63,"unit":"Kg/kkg (or pounds per 1,000 lb) of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart W—Aluminum Fluoride Production Subcategory","existing sources (BPT)","table: Subpart W—Aluminum Fluoride","column: Pollutant or pollutant property"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.232 (BPT)","page":null,"quote":"Fluoride (T) 1.3 0.63"}},{"id":"93a74b8f7a9d10af","parameter":"Fluoride","value":"50","value_num":50,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart BC—Sodium Fluoride Production Subcategory","existing sources (PSES)","table: Subpart BC—Sodium Fluoride"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.554 (PSES)","page":null,"quote":"Fluoride 50 25"}},{"id":"555d5928fb73a10f","parameter":"Fluoride","value":"25","value_num":25,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart BC—Sodium Fluoride Production Subcategory","existing sources (PSES)","table: Subpart BC—Sodium Fluoride"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.554 (PSES)","page":null,"quote":"Fluoride 50 25"}},{"id":"78fefd296ee3b542","parameter":"Fluoride","value":"75","value_num":75,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 418","the discharge is of the Subpart A—Phosphate Subcategory","existing sources (BPT)","(c) The concentration of pollutants discharged in process wastewater pursuant to the limitations of paragraph (b) shall not exceed the values listed in the following table:"],"cite":{"instrument":"us_40cfr418","title":"40 CFR Part 418 — PART 418—FERTILIZER MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=418","source_sha256":"881822302cd9912ec4678ba7ccaa00276ff06f33a48ae154f399db6986c1ffda","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 418.12 (BPT)","page":null,"quote":"Fluoride 75 25"}},{"id":"a258d2e3db510666","parameter":"Fluoride","value":"25","value_num":25,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 418","the discharge is of the Subpart A—Phosphate Subcategory","existing sources (BPT)","(c) The concentration of pollutants discharged in process wastewater pursuant to the limitations of paragraph (b) shall not exceed the values listed in the following table:"],"cite":{"instrument":"us_40cfr418","title":"40 CFR Part 418 — PART 418—FERTILIZER MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=418","source_sha256":"881822302cd9912ec4678ba7ccaa00276ff06f33a48ae154f399db6986c1ffda","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 418.12 (BPT)","page":null,"quote":"Fluoride 75 25"}},{"id":"788af66f12cd0dbb","parameter":"Fluoride","value":"75","value_num":75,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 418","the discharge is of the Subpart A—Phosphate Subcategory","existing sources (BPT)","(d) The concentration of pollutants discharged in contaminated non-process wastewater shall not exceed the values listed in the following table:"],"cite":{"instrument":"us_40cfr418","title":"40 CFR Part 418 — PART 418—FERTILIZER MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=418","source_sha256":"881822302cd9912ec4678ba7ccaa00276ff06f33a48ae154f399db6986c1ffda","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 418.12 (BPT)","page":null,"quote":"Fluoride 75 25"}},{"id":"634d0b789c2b1571","parameter":"Fluoride","value":"25","value_num":25,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 418","the discharge is of the Subpart A—Phosphate Subcategory","existing sources (BPT)","(d) The concentration of pollutants discharged in contaminated non-process wastewater shall not exceed the values listed in the following table:"],"cite":{"instrument":"us_40cfr418","title":"40 CFR Part 418 — PART 418—FERTILIZER MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=418","source_sha256":"881822302cd9912ec4678ba7ccaa00276ff06f33a48ae154f399db6986c1ffda","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 418.12 (BPT)","page":null,"quote":"Fluoride 75 25"}},{"id":"659b6e3ec04fba28","parameter":"Fluoride","value":"75","value_num":75,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 418","the discharge is of the Subpart A—Phosphate Subcategory","existing sources (BAT)","(c) The concentration of pollutants discharged in process wastewater pursuant to the limitations of paragraph (b) of this section shall not exceed the values listed in the following table:"],"cite":{"instrument":"us_40cfr418","title":"40 CFR Part 418 — PART 418—FERTILIZER MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=418","source_sha256":"881822302cd9912ec4678ba7ccaa00276ff06f33a48ae154f399db6986c1ffda","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 418.13 (BAT)","page":null,"quote":"Fluoride 75 25"}},{"id":"d75118162142a1e5","parameter":"Fluoride","value":"25","value_num":25,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 418","the discharge is of the Subpart A—Phosphate Subcategory","existing sources (BAT)","(c) The concentration of pollutants discharged in process wastewater pursuant to the limitations of paragraph (b) of this section shall not exceed the values listed in the following table:"],"cite":{"instrument":"us_40cfr418","title":"40 CFR Part 418 — PART 418—FERTILIZER MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=418","source_sha256":"881822302cd9912ec4678ba7ccaa00276ff06f33a48ae154f399db6986c1ffda","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 418.13 (BAT)","page":null,"quote":"Fluoride 75 25"}},{"id":"348ffd17c4893b88","parameter":"Fluoride","value":"75","value_num":75,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 418","the discharge is of the Subpart A—Phosphate Subcategory","existing sources (BAT)","(d) The concentration of pollutants discharged in contaminated non-process wastewater shall not exceed the values listed in the following table:"],"cite":{"instrument":"us_40cfr418","title":"40 CFR Part 418 — PART 418—FERTILIZER MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=418","source_sha256":"881822302cd9912ec4678ba7ccaa00276ff06f33a48ae154f399db6986c1ffda","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 418.13 (BAT)","page":null,"quote":"Fluoride 75 25"}},{"id":"0744bf4cff3eccf0","parameter":"Fluoride","value":"25","value_num":25,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 418","the discharge is of the Subpart A—Phosphate Subcategory","existing sources (BAT)","(d) The concentration of pollutants discharged in contaminated non-process wastewater shall not exceed the values listed in the following table:"],"cite":{"instrument":"us_40cfr418","title":"40 CFR Part 418 — PART 418—FERTILIZER MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=418","source_sha256":"881822302cd9912ec4678ba7ccaa00276ff06f33a48ae154f399db6986c1ffda","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 418.13 (BAT)","page":null,"quote":"Fluoride 75 25"}},{"id":"0793cbb06822cafd","parameter":"Fluoride","value":"75","value_num":75,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 418","the discharge is of the Subpart A—Phosphate Subcategory","new sources (NSPS)","(c) The concentration of pollutants discharged in process wastewater pursuant to the limitations of paragraph (b) shall not exceed the values listed in the following table:"],"cite":{"instrument":"us_40cfr418","title":"40 CFR Part 418 — PART 418—FERTILIZER MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=418","source_sha256":"881822302cd9912ec4678ba7ccaa00276ff06f33a48ae154f399db6986c1ffda","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 418.15 (NSPS)","page":null,"quote":"Fluoride 75 25"}},{"id":"be5e877a22e50baa","parameter":"Fluoride","value":"25","value_num":25,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 418","the discharge is of the Subpart A—Phosphate Subcategory","new sources (NSPS)","(c) The concentration of pollutants discharged in process wastewater pursuant to the limitations of paragraph (b) shall not exceed the values listed in the following table:"],"cite":{"instrument":"us_40cfr418","title":"40 CFR Part 418 — PART 418—FERTILIZER MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=418","source_sha256":"881822302cd9912ec4678ba7ccaa00276ff06f33a48ae154f399db6986c1ffda","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 418.15 (NSPS)","page":null,"quote":"Fluoride 75 25"}},{"id":"7b14c2d38b107652","parameter":"Fluoride","value":"75","value_num":75,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 418","the discharge is of the Subpart A—Phosphate Subcategory","new sources (NSPS)","(d) The concentration of pollutants discharged in contaminated non-process wastewater shall not exceed the values listed in the following table:"],"cite":{"instrument":"us_40cfr418","title":"40 CFR Part 418 — PART 418—FERTILIZER MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=418","source_sha256":"881822302cd9912ec4678ba7ccaa00276ff06f33a48ae154f399db6986c1ffda","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 418.15 (NSPS)","page":null,"quote":"Fluoride 75 25"}},{"id":"951d822c3bd0a149","parameter":"Fluoride","value":"25","value_num":25,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 418","the discharge is of the Subpart A—Phosphate Subcategory","new sources (NSPS)","(d) The concentration of pollutants discharged in contaminated non-process wastewater shall not exceed the values listed in the following table:"],"cite":{"instrument":"us_40cfr418","title":"40 CFR Part 418 — PART 418—FERTILIZER MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=418","source_sha256":"881822302cd9912ec4678ba7ccaa00276ff06f33a48ae154f399db6986c1ffda","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 418.15 (NSPS)","page":null,"quote":"Fluoride 75 25"}},{"id":"49960e705523a119","parameter":"Fluoride","value":"2.0","value_num":2,"unit":"kg/kkg of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.22 (BPT)","page":null,"quote":"Fluoride 2.0 1.0"}},{"id":"66058426c1fc589e","parameter":"Fluoride","value":"1.0","value_num":1,"unit":"kg/kkg of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.22 (BPT)","page":null,"quote":"Fluoride 2.0 1.0"}},{"id":"6b575f865c0406cc","parameter":"Fluoride","value":"8.092","value_num":8.092,"unit":"mg/kg (pounds per million pounds) of paste produced","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(a) Subpart B—Anode and Cathode Paste Plant Wet Air Pollution Control","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 8.092 3.591"}},{"id":"ac694704e8e2fb59","parameter":"Fluoride","value":"3.591","value_num":3.591,"unit":"mg/kg (pounds per million pounds) of paste produced","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(a) Subpart B—Anode and Cathode Paste Plant Wet Air Pollution Control","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 8.092 3.591"}},{"id":"f4502ef6698a6c28","parameter":"Fluoride","value":"12.440","value_num":12.44,"unit":"mg/kg (pounds per million pounds) of anodes cast","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(b) Subpart (B)—Anode Contact Cooling and Briquette Quenching.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 12.440 5.518"}},{"id":"a02eb324dbee535b","parameter":"Fluoride","value":"5.518","value_num":5.518,"unit":"mg/kg (pounds per million pounds) of anodes cast","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(b) Subpart (B)—Anode Contact Cooling and Briquette Quenching.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 12.440 5.518"}},{"id":"6ce05cee1e81bdb2","parameter":"Fluoride","value":"257.300","value_num":257.3,"unit":"mg/kg (pounds per million pounds) of anodes baked","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(c) Subpart (B)—Anode Bake Plant Wet Air Pollution Control (Closed Top Ring Furnace).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 257.300 114.200"}},{"id":"6e25ff9ffa2cd046","parameter":"Fluoride","value":"114.200","value_num":114.2,"unit":"mg/kg (pounds per million pounds) of anodes baked","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(c) Subpart (B)—Anode Bake Plant Wet Air Pollution Control (Closed Top Ring Furnace).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 257.300 114.200"}},{"id":"bd70de9aed434bb3","parameter":"Fluoride","value":"2.975","value_num":2.975,"unit":"mg/kg (pounds per million pounds) of anodes baked","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(d) Subpart B—Anode Bake Plant Wet Air Pollution Control (Open Top Ring Furnace With Spray Tower Only).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 2.975 1.320"}},{"id":"d1e5d91e255886d4","parameter":"Fluoride","value":"1.320","value_num":1.32,"unit":"mg/kg (pounds per million pounds) of anodes baked","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(d) Subpart B—Anode Bake Plant Wet Air Pollution Control (Open Top Ring Furnace With Spray Tower Only).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 2.975 1.320"}},{"id":"d989352fb20c52a0","parameter":"Fluoride","value":"43.440","value_num":43.44,"unit":"mg/kg (pounds per million pounds) of anodes baked","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(e) Subpart B—Anode Bake Plant Wet Air Pollution Control (Open Top Ring Furnace With Wet Electrostatic Precipitator and Spray Tower).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 43.440 19.270"}},{"id":"5636734529de525c","parameter":"Fluoride","value":"19.270","value_num":19.27,"unit":"mg/kg (pounds per million pounds) of anodes baked","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(e) Subpart B—Anode Bake Plant Wet Air Pollution Control (Open Top Ring Furnace With Wet Electrostatic Precipitator and Spray Tower).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 43.440 19.270"}},{"id":"30a94e116a0f0a81","parameter":"Fluoride","value":"67.710","value_num":67.71,"unit":"mg/kg (pounds per million pounds) of anodes baked","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(f) Subpart B—Anode Bake Plant Wet Air Pollution Control (Tunnel Kiln).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 67.710 30.050"}},{"id":"b0ec389291df69cb","parameter":"Fluoride","value":"30.050","value_num":30.05,"unit":"mg/kg (pounds per million pounds) of anodes baked","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(f) Subpart B—Anode Bake Plant Wet Air Pollution Control (Tunnel Kiln).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 67.710 30.050"}},{"id":"b7487f0860a22b58","parameter":"Fluoride","value":"29,430.000","value_num":29430,"unit":"mg/kg (pounds per million pounds) of cryolite recovered","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(g) Subpart B—Cathode Reprocessing (Operated With Dry Potline Scrubbing and Not Commingled With Other Process or Nonprocess Waters).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 29,430.000 13,310.000"}},{"id":"80b5bb507d77beff","parameter":"Fluoride","value":"13,310.000","value_num":13310,"unit":"mg/kg (pounds per million pounds) of cryolite recovered","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(g) Subpart B—Cathode Reprocessing (Operated With Dry Potline Scrubbing and Not Commingled With Other Process or Nonprocess Waters).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 29,430.000 13,310.000"}},{"id":"4b97b670227e2195","parameter":"Fluoride","value":"2,084.000","value_num":2084,"unit":"mg/kg (pounds per million pounds) of cryolite recovered","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(h) Subpart B—Cathode Reprocessing (Operated With Dry Potline Scrubbing and Commingled With Other Process or Nonprocess Waters).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 2,084.000 924.800"}},{"id":"a622241c6f3ee9f5","parameter":"Fluoride","value":"924.800","value_num":924.8,"unit":"mg/kg (pounds per million pounds) of cryolite recovered","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(h) Subpart B—Cathode Reprocessing (Operated With Dry Potline Scrubbing and Commingled With Other Process or Nonprocess Waters).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 2,084.000 924.800"}},{"id":"7917c17e3ad94857","parameter":"Fluoride","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of cryolite recovered","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(i) Subpart B—Cathode Reprocessing (Operated With Wet Potline Scrubbing).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride .000 .000"}},{"id":"650a89bbad7eccf0","parameter":"Fluoride","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of cryolite recovered","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(i) Subpart B—Cathode Reprocessing (Operated With Wet Potline Scrubbing).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride .000 .000"}},{"id":"5dec7c5c657faaa1","parameter":"Fluoride","value":"49.860","value_num":49.86,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(j) Subpart B—Potline Wet Air Pollution Control (Operated Without Cathode Reprocessing).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 49.860 22.130"}},{"id":"3962a4dafbfffd93","parameter":"Fluoride","value":"22.130","value_num":22.13,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(j) Subpart B—Potline Wet Air Pollution Control (Operated Without Cathode Reprocessing).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 49.860 22.130"}},{"id":"89297c154ed18ee8","parameter":"Fluoride","value":"703.900","value_num":703.9,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(k) Subpart B—Potline Wet Air Pollution Control (Operated With Cathode Reprocessing and Not Commingled With Other Process or Nonprocess Waters).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 703.900 318.500"}},{"id":"a07c32c82ac4117f","parameter":"Fluoride","value":"318.500","value_num":318.5,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(k) Subpart B—Potline Wet Air Pollution Control (Operated With Cathode Reprocessing and Not Commingled With Other Process or Nonprocess Waters).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 703.900 318.500"}},{"id":"7948aa2e19e60dba","parameter":"Fluoride","value":"49.860","value_num":49.86,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(l) Potline Wet Air Pollution Control Cooperated With Cathode Reprocessing and Commingled With Other Process or Nonprocess Wastewaters).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 49.860 22.130"}},{"id":"d327b237f828be3b","parameter":"Fluoride","value":"22.130","value_num":22.13,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(l) Potline Wet Air Pollution Control Cooperated With Cathode Reprocessing and Commingled With Other Process or Nonprocess Wastewaters).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 49.860 22.130"}},{"id":"358c1ec7001f6267","parameter":"Fluoride","value":"98.770","value_num":98.77,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(m) Subpart B—Potroom Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 98.770 43.830"}},{"id":"d736a74f97eb596a","parameter":"Fluoride","value":"43.830","value_num":43.83,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(m) Subpart B—Potroom Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 98.770 43.830"}},{"id":"3995dbce864a5784","parameter":"Fluoride","value":"79.790","value_num":79.79,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(n) Subpart B—Potline SO 2 Emissions Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 79.790 35.400"}},{"id":"906308e65ffb6c69","parameter":"Fluoride","value":"35.400","value_num":35.4,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(n) Subpart B—Potline SO 2 Emissions Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 79.790 35.400"}},{"id":"10aa13871a8f4744","parameter":"Fluoride","value":"155.300","value_num":155.3,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(o) Subpart B—Degassing Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 155.300 68.880"}},{"id":"0a744a6ddfaa4736","parameter":"Fluoride","value":"68.880","value_num":68.88,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(o) Subpart B—Degassing Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 155.300 68.880"}},{"id":"b1f558a09a0d5efb","parameter":"Fluoride","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(p) Subpart B—Pot Repair and Pot Soaking.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride .000 .000"}},{"id":"3bd4ca6586aa22ac","parameter":"Fluoride","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(p) Subpart B—Pot Repair and Pot Soaking.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride .000 .000"}},{"id":"aa5302ef53d069b2","parameter":"Fluoride","value":"79.080","value_num":79.08,"unit":"mg/kg (pound per million pounds) of aluminum product from direct chill casting","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(q) Subpart B—Direct Chill Casting Contact Cooling.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 79.080 35.090"}},{"id":"f32001cb98aa4626","parameter":"Fluoride","value":"35.090","value_num":35.09,"unit":"mg/kg (pound per million pounds) of aluminum product from direct chill casting","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(q) Subpart B—Direct Chill Casting Contact Cooling.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 79.080 35.090"}},{"id":"55aaed3134d349c5","parameter":"Fluoride","value":"6.188","value_num":6.188,"unit":"mg/kg (pound per million pounds) of aluminum product from rod casting","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(r) Subpart B—Continuous Rod Casting Contact Cooling.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 6.188 2.746"}},{"id":"8e96b666f8ea26d1","parameter":"Fluoride","value":"2.746","value_num":2.746,"unit":"mg/kg (pound per million pounds) of aluminum product from rod casting","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(r) Subpart B—Continuous Rod Casting Contact Cooling.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride 6.188 2.746"}},{"id":"85a35e4de5cc95e3","parameter":"Fluoride","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of aluminum product from stationary casting or shot casting","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(s) Subpart B—Stationary Casting or Shot Casting Contact Cooling.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride .000 .000"}},{"id":"0d90418c52a0259f","parameter":"Fluoride","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of aluminum product from stationary casting or shot casting","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(s) Subpart B—Stationary Casting or Shot Casting Contact Cooling.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Fluoride .000 .000"}},{"id":"09a455d1b91396ed","parameter":"Fluoride","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of paste produced","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(a) Subpart B—Anode and Cathode Paste Plant Wet Air.","table: Pollution Control—NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Fluoride .000 .000"}},{"id":"6fb129bef3cf7161","parameter":"Fluoride","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of paste produced","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(a) Subpart B—Anode and Cathode Paste Plant Wet Air.","table: Pollution Control—NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Fluoride .000 .000"}},{"id":"407566c73ff481ea","parameter":"Fluoride","value":"12.440","value_num":12.44,"unit":"mg/kg (pound per million pounds) of anodes cast","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(b) Subpart B—Anode Contact Cooling and Briquette Quenching.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Fluoride 12.440 5.518"}},{"id":"b1b32e691b169600","parameter":"Fluoride","value":"5.518","value_num":5.518,"unit":"mg/kg (pound per million pounds) of anodes cast","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(b) Subpart B—Anode Contact Cooling and Briquette Quenching.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Fluoride 12.440 5.518"}},{"id":"3e7013fdc6155424","parameter":"Fluoride","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of anodes baked","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(c) Subpart B—Anode Bake Plant Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Fluoride .000 .000"}},{"id":"4e2cb16f0e2100e5","parameter":"Fluoride","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of anodes baked","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(c) Subpart B—Anode Bake Plant Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Fluoride .000 .000"}},{"id":"8ead77fd96aec24c","parameter":"Fluoride","value":"29,430.000","value_num":29430,"unit":"mg/kg (pound per million pounds) of cryolite recovered","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(d) Subpart B—Cathode Reprocessing (Operated With Dry Potline Scrubbing and Not Commingled With Other Process or Nonprocess Waters).","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Fluoride 29,430.000 13,310.000"}},{"id":"3a812376db76c032","parameter":"Fluoride","value":"13,310.000","value_num":13310,"unit":"mg/kg (pound per million pounds) of cryolite recovered","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(d) Subpart B—Cathode Reprocessing (Operated With Dry Potline Scrubbing and Not Commingled With Other Process or Nonprocess Waters).","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Fluoride 29,430.000 13,310.000"}},{"id":"adb6486f9fdb6a2b","parameter":"Fluoride","value":"2,084.000","value_num":2084,"unit":"mg/kg (pound per million pounds) of cryolite recovered","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(e) Subpart B—Cathode Reprocessing (Operated With Dry Potline Scrubbing and Commingled With Other Process or Nonprocess Waters).","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Fluoride 2,084.000 924.800"}},{"id":"c3663f27fc0a9628","parameter":"Fluoride","value":"924.800","value_num":924.8,"unit":"mg/kg (pound per million pounds) of cryolite recovered","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(e) Subpart B—Cathode Reprocessing (Operated With Dry Potline Scrubbing and Commingled With Other Process or Nonprocess Waters).","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Fluoride 2,084.000 924.800"}},{"id":"569ca884171d4e7c","parameter":"Fluoride","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(f) Subpart B—Potline Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Fluoride .000 .000"}},{"id":"5341e0e3d6f6dc12","parameter":"Fluoride","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(f) Subpart B—Potline Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Fluoride .000 .000"}},{"id":"64fb652398a0d217","parameter":"Fluoride","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(g) Subpart B—Potroom Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Fluoride .000 .000"}},{"id":"2e8eaf3ed2bad025","parameter":"Fluoride","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(g) Subpart B—Potroom Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Fluoride .000 .000"}},{"id":"ac32fb740694c001","parameter":"Fluoride","value":"79.790","value_num":79.79,"unit":"mg/kg (pound per million pounds) aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(h) Subpart B—Potline SO 2 Emissions Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Fluoride 79.790 35.400"}},{"id":"119ea30e08407b5d","parameter":"Fluoride","value":"35.400","value_num":35.4,"unit":"mg/kg (pound per million pounds) aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(h) Subpart B—Potline SO 2 Emissions Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Fluoride 79.790 35.400"}},{"id":"6e642c3af4fd4f18","parameter":"Fluoride","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(i) Subpart B—Degassing Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Fluoride .000 .000"}},{"id":"9c4dfaa9e5e6f50f","parameter":"Fluoride","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(i) Subpart B—Degassing Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Fluoride .000 .000"}},{"id":"513f408579c162da","parameter":"Fluoride","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(j) Subpart B—Pot Repair and Pot Soaking.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Fluoride .000 .000"}},{"id":"1d83cbd4fbc11def","parameter":"Fluoride","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(j) Subpart B—Pot Repair and Pot Soaking.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Fluoride .000 .000"}},{"id":"ab7eeed5f412cb10","parameter":"Fluoride","value":"79.080","value_num":79.08,"unit":"mg/kg (pound per million pounds) of aluminum product from direct chill casting","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(k) Subpart B—Direct Chill Casting Contact Cooling.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Fluoride 79.080 35.090"}},{"id":"5f4a56515074ec88","parameter":"Fluoride","value":"35.090","value_num":35.09,"unit":"mg/kg (pound per million pounds) of aluminum product from direct chill casting","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(k) Subpart B—Direct Chill Casting Contact Cooling.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Fluoride 79.080 35.090"}},{"id":"3a1649365545262a","parameter":"Fluoride","value":"6.188","value_num":6.188,"unit":"mg/kg (pound per million pounds) of aluminum product from rod casting","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(l) Subpart B—Continuous Rod Casting Contact Cooling.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Fluoride 6.188 2.746"}},{"id":"a8ee478e21b736e6","parameter":"Fluoride","value":"2.746","value_num":2.746,"unit":"mg/kg (pound per million pounds) of aluminum product from rod casting","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(l) Subpart B—Continuous Rod Casting Contact Cooling.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Fluoride 6.188 2.746"}},{"id":"1b8f3e63486033ee","parameter":"Fluoride","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of aluminum product from stationary casting or shot casting","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(m) Subpart B—Stationary Casting or Shot Casting Contact Cooling.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Fluoride .000 .000"}},{"id":"8521dbf1037fadaf","parameter":"Fluoride","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of aluminum product from stationary casting or shot casting","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(m) Subpart B—Stationary Casting or Shot Casting Contact Cooling.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Fluoride .000 .000"}},{"id":"5a2a2538628d3bb3","parameter":"Fluoride","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of paste produced","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (PSNS)","(a) Subpart B—Anode and Cathode Paste Plant Wet Air Pollution Control.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.26 (PSNS)","page":null,"quote":"Fluoride .000 .000"}},{"id":"08828ad745db35aa","parameter":"Fluoride","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of paste produced","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (PSNS)","(a) Subpart B—Anode and Cathode Paste Plant Wet Air Pollution Control.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.26 (PSNS)","page":null,"quote":"Fluoride .000 .000"}},{"id":"6c0d8dfb3b1eff80","parameter":"Fluoride","value":"12.440","value_num":12.44,"unit":"mg/kg (pounds per million pounds) of anodes cast","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (PSNS)","(b) Subpart B—Anode Contact Cooling and Briquette Quenching.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.26 (PSNS)","page":null,"quote":"Fluoride 12.440 5.518"}},{"id":"c2ba62bd49c0d748","parameter":"Fluoride","value":"5.518","value_num":5.518,"unit":"mg/kg (pounds per million pounds) of anodes cast","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (PSNS)","(b) Subpart B—Anode Contact Cooling and Briquette Quenching.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.26 (PSNS)","page":null,"quote":"Fluoride 12.440 5.518"}},{"id":"82e834329c6da3e3","parameter":"Fluoride","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of anodes baked","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (PSNS)","(c) Subpart B—Anode Bake Plant Wet Air Pollution Control.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.26 (PSNS)","page":null,"quote":"Fluoride .000 .000"}},{"id":"2992e029782dd737","parameter":"Fluoride","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of anodes baked","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (PSNS)","(c) Subpart B—Anode Bake Plant Wet Air Pollution Control.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.26 (PSNS)","page":null,"quote":"Fluoride .000 .000"}},{"id":"81ee4a12f07eba12","parameter":"Fluoride","value":"29,430.000","value_num":29430,"unit":"mg/kg (pounds per million pounds) of cryolite recovered","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (PSNS)","(d) Subpart B—Cathode Reprocessing (Operated With Dry Potline Scrubbing and Not Commingled With Other Process or Nonprocess Waters).","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.26 (PSNS)","page":null,"quote":"Fluoride 29,430.000 13,310.000"}},{"id":"b371a91b117c35e7","parameter":"Fluoride","value":"13,310.000","value_num":13310,"unit":"mg/kg (pounds per million pounds) of cryolite recovered","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (PSNS)","(d) Subpart B—Cathode Reprocessing (Operated With Dry Potline Scrubbing and Not Commingled With Other Process or Nonprocess Waters).","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.26 (PSNS)","page":null,"quote":"Fluoride 29,430.000 13,310.000"}},{"id":"2b03881d661c451a","parameter":"Fluoride","value":"2,084.000","value_num":2084,"unit":"mg/kg (pounds per million pounds) of cryolite recovered","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (PSNS)","(e) Subpart B—Cathode Reprocessing (Operated With Dry Potline Scrubbing and Commingled With Other Process or Nonprocess Waters).","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.26 (PSNS)","page":null,"quote":"Fluoride 2,084.000 924.800"}},{"id":"270139d98d4de514","parameter":"Fluoride","value":"924.800","value_num":924.8,"unit":"mg/kg (pounds per million pounds) of cryolite recovered","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (PSNS)","(e) Subpart B—Cathode Reprocessing (Operated With Dry Potline Scrubbing and Commingled With Other Process or Nonprocess Waters).","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.26 (PSNS)","page":null,"quote":"Fluoride 2,084.000 924.800"}},{"id":"026392fbb43baabc","parameter":"Fluoride","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (PSNS)","(f) Subpart B—Potline Wet Air Pollution Control.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.26 (PSNS)","page":null,"quote":"Fluoride .000 .000"}},{"id":"417b8f27b1e67ed0","parameter":"Fluoride","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (PSNS)","(f) Subpart B—Potline Wet Air Pollution Control.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.26 (PSNS)","page":null,"quote":"Fluoride .000 .000"}},{"id":"40c6e1bc64377495","parameter":"Fluoride","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (PSNS)","(g) Subpart B—Potroom Wet Air Pollution Control.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.26 (PSNS)","page":null,"quote":"Fluoride .000 .000"}},{"id":"59be0e9abf49e7ce","parameter":"Fluoride","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (PSNS)","(g) Subpart B—Potroom Wet Air Pollution Control.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.26 (PSNS)","page":null,"quote":"Fluoride .000 .000"}},{"id":"602246c5d4c7dd27","parameter":"Fluoride","value":"79.790","value_num":79.79,"unit":"mg/kg (pounds per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (PSNS)","(h) Subpart B—Potline SO 2 Emissions Wet Air Pollution Control.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.26 (PSNS)","page":null,"quote":"Fluoride 79.790 35.400"}},{"id":"7afe048945857884","parameter":"Fluoride","value":"35.400","value_num":35.4,"unit":"mg/kg (pounds per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (PSNS)","(h) Subpart B—Potline SO 2 Emissions Wet Air Pollution Control.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.26 (PSNS)","page":null,"quote":"Fluoride 79.790 35.400"}},{"id":"0543f4a4bc58d3ec","parameter":"Fluoride","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (PSNS)","(i) Subpart B—Degassing Wet Air Pollution Control.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.26 (PSNS)","page":null,"quote":"Fluoride .000 .000"}},{"id":"aa1bc7642096aad4","parameter":"Fluoride","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (PSNS)","(i) Subpart B—Degassing Wet Air Pollution Control.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.26 (PSNS)","page":null,"quote":"Fluoride .000 .000"}},{"id":"2583f4fa24df10b9","parameter":"Fluoride","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (PSNS)","(j) Subpart B—Pot Repair and Pot Soaking.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.26 (PSNS)","page":null,"quote":"Fluoride .000 .000"}},{"id":"8ea3da3a49b25fe3","parameter":"Fluoride","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (PSNS)","(j) Subpart B—Pot Repair and Pot Soaking.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.26 (PSNS)","page":null,"quote":"Fluoride .000 .000"}},{"id":"dc80d7e417d8214f","parameter":"Fluoride","value":"79.080","value_num":79.08,"unit":"mg/kg (pounds per million pounds) of aluminum product from direct chill casting","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (PSNS)","(k) Subpart B—Direct Chill Casting Contact Cooling.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.26 (PSNS)","page":null,"quote":"Fluoride 79.080 35.090"}},{"id":"def41e8eb6dcc935","parameter":"Fluoride","value":"35.090","value_num":35.09,"unit":"mg/kg (pounds per million pounds) of aluminum product from direct chill casting","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (PSNS)","(k) Subpart B—Direct Chill Casting Contact Cooling.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.26 (PSNS)","page":null,"quote":"Fluoride 79.080 35.090"}},{"id":"c02a3086633f27f4","parameter":"Fluoride","value":"6.188","value_num":6.188,"unit":"mg/kg (pound per million pounds) of aluminum product from rod casting","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (PSNS)","(l) Subpart B—Continuous Rod Casting Contact Cooling.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.26 (PSNS)","page":null,"quote":"Fluoride 6.188 2.746"}},{"id":"667f21a874a54357","parameter":"Fluoride","value":"2.746","value_num":2.746,"unit":"mg/kg (pound per million pounds) of aluminum product from rod casting","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (PSNS)","(l) Subpart B—Continuous Rod Casting Contact Cooling.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.26 (PSNS)","page":null,"quote":"Fluoride 6.188 2.746"}},{"id":"3b15a4d4425be7b9","parameter":"Fluoride","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of aluminum product from stationary casting or shot casting","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (PSNS)","(m) Subpart B—Stationary Casting or Shot Casting Contact Cooling.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.26 (PSNS)","page":null,"quote":"Fluoride .000 .000"}},{"id":"418913f1c2ccdb8a","parameter":"Fluoride","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of aluminum product from stationary casting or shot casting","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (PSNS)","(m) Subpart B—Stationary Casting or Shot Casting Contact Cooling.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.26 (PSNS)","page":null,"quote":"Fluoride .000 .000"}},{"id":"fb94c22e573b87f6","parameter":"Fluoride","value":"0.4","value_num":0.4,"unit":"kilograms per 1,000 kg of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","existing sources (BPT)","(d) The following limitations establish the quantity or quality of pollutants or pollutant properties which may be discharged by a point source subject to the provisions of this subpart and which processes residues by wet methods, after application of the best practical control technology currently available:","table: Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.32 (BPT)","page":null,"quote":"Fluoride 0.4"}},{"id":"b19cd310aa50c779","parameter":"Fluoride","value":"212.800","value_num":212.8,"unit":"mg/kg (pounds per million pounds of 100% sulfuric acid capacity","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart I—Metallurgical Acid Plants Subcategory","existing sources (BPT)","table: Subpart I—Metallurgical Acid Plant"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.92 (BPT)","page":null,"quote":"Fluoride 1 212.800 121.000"}},{"id":"5264237eb3d1132a","parameter":"Fluoride","value":"121.000","value_num":121,"unit":"mg/kg (pounds per million pounds of 100% sulfuric acid capacity","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart I—Metallurgical Acid Plants Subcategory","existing sources (BPT)","table: Subpart I—Metallurgical Acid Plant"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.92 (BPT)","page":null,"quote":"Fluoride 1 212.800 121.000"}},{"id":"d3dca2cdfd0574ce","parameter":"Fluoride","value":"89.390","value_num":89.39,"unit":"mg/kg (pounds per/million pounds) of 100 pct sulfuric acid capacity","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart I—Metallurgical Acid Plants Subcategory","existing sources (BAT)","table: Subpart I—Metallurgical Acid Plant—BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.93 (BAT)","page":null,"quote":"Fluoride 1 89.390 50.820"}},{"id":"87b694bd19679247","parameter":"Fluoride","value":"50.820","value_num":50.82,"unit":"mg/kg (pounds per/million pounds) of 100 pct sulfuric acid capacity","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart I—Metallurgical Acid Plants Subcategory","existing sources (BAT)","table: Subpart I—Metallurgical Acid Plant—BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.93 (BAT)","page":null,"quote":"Fluoride 1 89.390 50.820"}},{"id":"4397479bdb19db3c","parameter":"Fluoride","value":"89.390","value_num":89.39,"unit":"mg/kg (pounds per/million pounds) of 100 pct sulfuric acid capacity","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart I—Metallurgical Acid Plants Subcategory","new sources (NSPS)","Any new source subject to this subpart shall achieve the following new source performance standards:","table: Subpart I—Metallurgical Acid Plant—NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.94 (NSPS)","page":null,"quote":"Fluoride 1 89.390 50.820"}},{"id":"b4e744927b97ddaf","parameter":"Fluoride","value":"50.820","value_num":50.82,"unit":"mg/kg (pounds per/million pounds) of 100 pct sulfuric acid capacity","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart I—Metallurgical Acid Plants Subcategory","new sources (NSPS)","Any new source subject to this subpart shall achieve the following new source performance standards:","table: Subpart I—Metallurgical Acid Plant—NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.94 (NSPS)","page":null,"quote":"Fluoride 1 89.390 50.820"}},{"id":"6a1c362f16f2613e","parameter":"Fluoride","value":"89.390","value_num":89.39,"unit":"mg/kg (pounds per million pounds) of 100 pct sulfuric acid capacity","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart I—Metallurgical Acid Plants Subcategory","new sources (PSNS)","table: Subpart I—Metallurgical Acid Plant—PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.96 (PSNS)","page":null,"quote":"Fluoride 1 89.390 50.820"}},{"id":"8c7b1458bf7e3f20","parameter":"Fluoride","value":"50.820","value_num":50.82,"unit":"mg/kg (pounds per million pounds) of 100 pct sulfuric acid capacity","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart I—Metallurgical Acid Plants Subcategory","new sources (PSNS)","table: Subpart I—Metallurgical Acid Plant—PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.96 (PSNS)","page":null,"quote":"Fluoride 1 89.390 50.820"}},{"id":"aa49b85ccf25bb9d","parameter":"Fluoride","value":"217.700","value_num":217.7,"unit":"mg/kg (pounds per million pounds) of concentrate digested","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BPT)","(a) Subpart K—Concentrate Digestion Wet Air Pollution Control.","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.112 (BPT)","page":null,"quote":"Fluoride 217.700 124.400"}},{"id":"939d9f81b6356a84","parameter":"Fluoride","value":"124.400","value_num":124.4,"unit":"mg/kg (pounds per million pounds) of concentrate digested","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BPT)","(a) Subpart K—Concentrate Digestion Wet Air Pollution Control.","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.112 (BPT)","page":null,"quote":"Fluoride 217.700 124.400"}},{"id":"5679873f8839f966","parameter":"Fluoride","value":"324.000","value_num":324,"unit":"mg/kg (pounds per million pounds) of concentrate digested","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BPT)","(b) Subpart K—Solvent Extraction Raffinate.","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.112 (BPT)","page":null,"quote":"Fluoride 324.000 185.100"}},{"id":"4b75f722798921e6","parameter":"Fluoride","value":"185.100","value_num":185.1,"unit":"mg/kg (pounds per million pounds) of concentrate digested","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BPT)","(b) Subpart K—Solvent Extraction Raffinate.","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.112 (BPT)","page":null,"quote":"Fluoride 324.000 185.100"}},{"id":"658ef500a78a108c","parameter":"Fluoride","value":"85.960","value_num":85.96,"unit":"mg/kg (pounds per million pounds) of concentrate digested","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BPT)","(c) Subpart K—Solvent Extraction Wet Air Pollution Control.","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.112 (BPT)","page":null,"quote":"Fluoride 85.960 49.120"}},{"id":"ef6eab2ac04ffb74","parameter":"Fluoride","value":"49.120","value_num":49.12,"unit":"mg/kg (pounds per million pounds) of concentrate digested","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BPT)","(c) Subpart K—Solvent Extraction Wet Air Pollution Control.","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.112 (BPT)","page":null,"quote":"Fluoride 85.960 49.120"}},{"id":"4fe4ff6eb8c03548","parameter":"Fluoride","value":"479.100","value_num":479.1,"unit":"mg/kg (pounds per million pounds) of concentrate digested","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BPT)","(d) Subpart K—Precipitation and Filtration.","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.112 (BPT)","page":null,"quote":"Fluoride 479.100 273.800"}},{"id":"dda4b38a53a5ef45","parameter":"Fluoride","value":"273.800","value_num":273.8,"unit":"mg/kg (pounds per million pounds) of concentrate digested","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BPT)","(d) Subpart K—Precipitation and Filtration.","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.112 (BPT)","page":null,"quote":"Fluoride 479.100 273.800"}},{"id":"e0b19eb45bfc71da","parameter":"Fluoride","value":"2,223.000","value_num":2223,"unit":"mg/kg (pounds per million pounds) of concentrate digested","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BPT)","(e) Subpart K—Precipitation and Filtration Wet Air Pollution Control.","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.112 (BPT)","page":null,"quote":"Fluoride 2,223.000 1,270.000"}},{"id":"3743ec840742eab0","parameter":"Fluoride","value":"1,270.000","value_num":1270,"unit":"mg/kg (pounds per million pounds) of concentrate digested","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BPT)","(e) Subpart K—Precipitation and Filtration Wet Air Pollution Control.","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.112 (BPT)","page":null,"quote":"Fluoride 2,223.000 1,270.000"}},{"id":"85190c5e8e04c96f","parameter":"Fluoride","value":"2,119.000","value_num":2119,"unit":"mg/kg (pounds per million pounds) of tantalum salt dried","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BPT)","(f) Subpart K—Tantalum Salt Drying.","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.112 (BPT)","page":null,"quote":"Fluoride 2,119.000 1,211.000"}},{"id":"9b62f0076c9115f4","parameter":"Fluoride","value":"1,211.000","value_num":1211,"unit":"mg/kg (pounds per million pounds) of tantalum salt dried","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BPT)","(f) Subpart K—Tantalum Salt Drying.","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.112 (BPT)","page":null,"quote":"Fluoride 2,119.000 1,211.000"}},{"id":"345eb1a923c89444","parameter":"Fluoride","value":"1,345.000","value_num":1345,"unit":"mg/kg (pounds per million pounds) of columbium-tantalum oxide dried","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BPT)","(g) Subpart K—Oxides Calcining Wet Air Pollution Control.","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.112 (BPT)","page":null,"quote":"Fluoride 1,345.000 768.500"}},{"id":"e21201075098b38e","parameter":"Fluoride","value":"768.500","value_num":768.5,"unit":"mg/kg (pounds per million pounds) of columbium-tantalum oxide dried","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BPT)","(g) Subpart K—Oxides Calcining Wet Air Pollution Control.","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.112 (BPT)","page":null,"quote":"Fluoride 1,345.000 768.500"}},{"id":"34df94145466dd58","parameter":"Fluoride","value":"5,813.000","value_num":5813,"unit":"mg/kg (pounds per million pounds) of tantalum salt reduced","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BPT)","(h) Subpart K—Reduction of Tantalum Salt to Metal.","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.112 (BPT)","page":null,"quote":"Fluoride 5,813.000 3,322.000"}},{"id":"fbc3175256202155","parameter":"Fluoride","value":"3,322.000","value_num":3322,"unit":"mg/kg (pounds per million pounds) of tantalum salt reduced","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BPT)","(h) Subpart K—Reduction of Tantalum Salt to Metal.","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.112 (BPT)","page":null,"quote":"Fluoride 5,813.000 3,322.000"}},{"id":"81890243ec777a82","parameter":"Fluoride","value":"71.510","value_num":71.51,"unit":"mg/kg (pounds per million pounds) of tantalum salt reduced","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BPT)","(i) Subpart K—Reduction of Tantalum Salt to Metal Wet Air Pollution Control.","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.112 (BPT)","page":null,"quote":"Fluoride 71.510 40.860"}},{"id":"aa99a1d02b09622f","parameter":"Fluoride","value":"40.860","value_num":40.86,"unit":"mg/kg (pounds per million pounds) of tantalum salt reduced","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BPT)","(i) Subpart K—Reduction of Tantalum Salt to Metal Wet Air Pollution Control.","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.112 (BPT)","page":null,"quote":"Fluoride 71.510 40.860"}},{"id":"b0c0d89a40798f9c","parameter":"Fluoride","value":"715.200","value_num":715.2,"unit":"mg/kg (pounds per million pounds) of tantalum power washed","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BPT)","(j) Subpart K—Tantalum Powder Wash.","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.112 (BPT)","page":null,"quote":"Fluoride 715.200 408.700"}},{"id":"0b5431c68ba0a747","parameter":"Fluoride","value":"408.700","value_num":408.7,"unit":"mg/kg (pounds per million pounds) of tantalum power washed","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BPT)","(j) Subpart K—Tantalum Powder Wash.","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.112 (BPT)","page":null,"quote":"Fluoride 715.200 408.700"}},{"id":"fee3d57e20c0f65e","parameter":"Fluoride","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of columbium or tantalum cast or consolidated","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BPT)","(k) Subpart K—Consolidation and Casting Contact Cooling.","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.112 (BPT)","page":null,"quote":"Fluoride .000 .000"}},{"id":"32522079a7d72560","parameter":"Fluoride","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of columbium or tantalum cast or consolidated","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BPT)","(k) Subpart K—Consolidation and Casting Contact Cooling.","table: BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.112 (BPT)","page":null,"quote":"Fluoride .000 .000"}},{"id":"838a9c7cac5e18fd","parameter":"Fluoride","value":"21.770","value_num":21.77,"unit":"mg/kg (pounds per million pounds) of concentrate digested","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BAT)","(a) Subpart K—Concentrate Digestion Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.113 (BAT)","page":null,"quote":"Fluoride 21.770 12.440"}},{"id":"20586405ed82c60f","parameter":"Fluoride","value":"12.440","value_num":12.44,"unit":"mg/kg (pounds per million pounds) of concentrate digested","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BAT)","(a) Subpart K—Concentrate Digestion Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.113 (BAT)","page":null,"quote":"Fluoride 21.770 12.440"}},{"id":"aec2301b003d9dd6","parameter":"Fluoride","value":"324.000","value_num":324,"unit":"mg/Kg (pounds per million pounds) of concentrate digested","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BAT)","(b) Subpart K—Solvent Extraction Raffinate.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.113 (BAT)","page":null,"quote":"Fluoride 324.000 185.100"}},{"id":"c3c017cf8b347fa8","parameter":"Fluoride","value":"185.100","value_num":185.1,"unit":"mg/Kg (pounds per million pounds) of concentrate digested","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BAT)","(b) Subpart K—Solvent Extraction Raffinate.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.113 (BAT)","page":null,"quote":"Fluoride 324.000 185.100"}},{"id":"c29beefd9afd347b","parameter":"Fluoride","value":"8.610","value_num":8.61,"unit":"mg/kg (pounds per million pounds) of concentrate digested","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BAT)","(c) Subpart K—Solvent Extraction Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.113 (BAT)","page":null,"quote":"Fluoride 8.610 4.920"}},{"id":"dd247aecac57f656","parameter":"Fluoride","value":"4.920","value_num":4.92,"unit":"mg/kg (pounds per million pounds) of concentrate digested","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BAT)","(c) Subpart K—Solvent Extraction Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.113 (BAT)","page":null,"quote":"Fluoride 8.610 4.920"}},{"id":"9c714d9e08e093b1","parameter":"Fluoride","value":"479.100","value_num":479.1,"unit":"mg/kg (pounds per million pounds) of concentrate digested","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BAT)","(d) Subpart K—Precipitation and Filtration.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.113 (BAT)","page":null,"quote":"Fluoride 479.100 273.800"}},{"id":"17cd959446efbcc8","parameter":"Fluoride","value":"273.800","value_num":273.8,"unit":"mg/kg (pounds per million pounds) of concentrate digested","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BAT)","(d) Subpart K—Precipitation and Filtration.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.113 (BAT)","page":null,"quote":"Fluoride 479.100 273.800"}},{"id":"9b08865ab7b126ea","parameter":"Fluoride","value":"222.300","value_num":222.3,"unit":"mg/kg (pounds per million pounds) of concentrate digested","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BAT)","(e) Subpart K—Precipitation and Filtration Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.113 (BAT)","page":null,"quote":"Fluoride 222.300 127.000"}},{"id":"e59c33e465531b1e","parameter":"Fluoride","value":"127.000","value_num":127,"unit":"mg/kg (pounds per million pounds) of concentrate digested","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BAT)","(e) Subpart K—Precipitation and Filtration Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.113 (BAT)","page":null,"quote":"Fluoride 222.300 127.000"}},{"id":"bf87c1f8f3d4aaa1","parameter":"Fluoride","value":"2,119.000","value_num":2119,"unit":"mg/kg (pounds per million pounds) of tantalum salt dried","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BAT)","(f) Subpart K—Tantalum Salt Drying.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.113 (BAT)","page":null,"quote":"Fluoride 2,119.000 1,211.000"}},{"id":"d1fcb1ecbfccfec5","parameter":"Fluoride","value":"1,211.000","value_num":1211,"unit":"mg/kg (pounds per million pounds) of tantalum salt dried","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BAT)","(f) Subpart K—Tantalum Salt Drying.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.113 (BAT)","page":null,"quote":"Fluoride 2,119.000 1,211.000"}},{"id":"b01d89ac75044975","parameter":"Fluoride","value":"134.500","value_num":134.5,"unit":"mg/kg (pounds per million pounds) of columbium-tantalum oxide","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BAT)","(g) Subpart K—Oxides Calcining Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.113 (BAT)","page":null,"quote":"Fluoride 134.500 76.840"}},{"id":"763c7d48103cdd74","parameter":"Fluoride","value":"76.840","value_num":76.84,"unit":"mg/kg (pounds per million pounds) of columbium-tantalum oxide","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BAT)","(g) Subpart K—Oxides Calcining Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.113 (BAT)","page":null,"quote":"Fluoride 134.500 76.840"}},{"id":"acbe9d722a420df4","parameter":"Fluoride","value":"5,813.000","value_num":5813,"unit":"mg/kg (pounds per million pounds) of tantalum salt reduced","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BAT)","(h) Subpart K—Reduction of Tantalum Salt to Metal.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.113 (BAT)","page":null,"quote":"Fluoride 5,813.000 3,322.000"}},{"id":"d4603882eb68328e","parameter":"Fluoride","value":"3,322.000","value_num":3322,"unit":"mg/kg (pounds per million pounds) of tantalum salt reduced","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BAT)","(h) Subpart K—Reduction of Tantalum Salt to Metal.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.113 (BAT)","page":null,"quote":"Fluoride 5,813.000 3,322.000"}},{"id":"004f1c49833429d7","parameter":"Fluoride","value":"71.510","value_num":71.51,"unit":"mg/kg (pounds per million pounds) of tantalum salt reduced","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BAT)","(i) Subpart K—Reduction of Tantalum Salt to Metal Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.113 (BAT)","page":null,"quote":"Fluoride 71.510 40.860"}},{"id":"58db98fe0a9bd520","parameter":"Fluoride","value":"40.860","value_num":40.86,"unit":"mg/kg (pounds per million pounds) of tantalum salt reduced","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BAT)","(i) Subpart K—Reduction of Tantalum Salt to Metal Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.113 (BAT)","page":null,"quote":"Fluoride 71.510 40.860"}},{"id":"42234bec853f4f7e","parameter":"Fluoride","value":"715.200","value_num":715.2,"unit":"mg/kg (pounds per million pounds) of tantalum powder washed","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BAT)","(j) Subpart K—Tantalum Powder Wash.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.113 (BAT)","page":null,"quote":"Fluoride 715.200 408.700"}},{"id":"0d4415547a12dbb8","parameter":"Fluoride","value":"408.700","value_num":408.7,"unit":"mg/kg (pounds per million pounds) of tantalum powder washed","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BAT)","(j) Subpart K—Tantalum Powder Wash.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.113 (BAT)","page":null,"quote":"Fluoride 715.200 408.700"}},{"id":"0f1c3fcf7aeb1751","parameter":"Fluoride","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of columbium or tantalum cast or consolidated","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BAT)","(k) Subpart K—Consolidation and Casting Contact Cooling.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.113 (BAT)","page":null,"quote":"Fluoride .000 .000"}},{"id":"c2b9d48b4afa1e96","parameter":"Fluoride","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of columbium or tantalum cast or consolidated","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","existing sources (BAT)","(k) Subpart K—Consolidation and Casting Contact Cooling.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.113 (BAT)","page":null,"quote":"Fluoride .000 .000"}},{"id":"fb5a788717706c0c","parameter":"Fluoride","value":"21.770","value_num":21.77,"unit":"mg/kg (pounds per million pounds) of concentrate digested","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","new sources (NSPS)","(a) Subpart K—Concentrate Digestion Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.114 (NSPS)","page":null,"quote":"Fluoride 21.770 12.440"}},{"id":"c93b61ee31f00305","parameter":"Fluoride","value":"12.440","value_num":12.44,"unit":"mg/kg (pounds per million pounds) of concentrate digested","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","new sources (NSPS)","(a) Subpart K—Concentrate Digestion Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.114 (NSPS)","page":null,"quote":"Fluoride 21.770 12.440"}},{"id":"ef20059ee53fba41","parameter":"Fluoride","value":"324.000","value_num":324,"unit":"mg/kg (pounds per million pounds) of concentrate digested","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","new sources (NSPS)","(b) Subpart K—Solvent Extraction Raffinate.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.114 (NSPS)","page":null,"quote":"Fluoride 324.000 185.100"}},{"id":"0fbbd9e6e8fb402d","parameter":"Fluoride","value":"185.100","value_num":185.1,"unit":"mg/kg (pounds per million pounds) of concentrate digested","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","new sources (NSPS)","(b) Subpart K—Solvent Extraction Raffinate.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.114 (NSPS)","page":null,"quote":"Fluoride 324.000 185.100"}},{"id":"3262633f2b13f7fa","parameter":"Fluoride","value":"8.610","value_num":8.61,"unit":"mg/kg (pounds per million pounds) of concentrate digested","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","new sources (NSPS)","(c) Subpart K—Solvent Extraction Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.114 (NSPS)","page":null,"quote":"Fluoride 8.610 4.920"}},{"id":"711a67d12cb8038b","parameter":"Fluoride","value":"4.920","value_num":4.92,"unit":"mg/kg (pounds per million pounds) of concentrate digested","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","new sources (NSPS)","(c) Subpart K—Solvent Extraction Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.114 (NSPS)","page":null,"quote":"Fluoride 8.610 4.920"}},{"id":"d43f0592de38a8e9","parameter":"Fluoride","value":"479.100","value_num":479.1,"unit":"mg/kg (pounds per million pounds) of concentrate digested","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","new sources (NSPS)","(d) Subpart K—Precipitation and Filtration.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.114 (NSPS)","page":null,"quote":"Fluoride 479.100 273.800"}},{"id":"bed8e1eb6dace4a8","parameter":"Fluoride","value":"273.800","value_num":273.8,"unit":"mg/kg (pounds per million pounds) of concentrate digested","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","new sources (NSPS)","(d) Subpart K—Precipitation and Filtration.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.114 (NSPS)","page":null,"quote":"Fluoride 479.100 273.800"}},{"id":"092bd9017a9e7f24","parameter":"Fluoride","value":"222.300","value_num":222.3,"unit":"mg/kg (pounds per million pounds) of concentrate digested","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","new sources (NSPS)","(e) Subpart K—Precipitation and Filtration Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.114 (NSPS)","page":null,"quote":"Fluoride 222.300 127.000"}},{"id":"f63a788d2f12f6e9","parameter":"Fluoride","value":"127.000","value_num":127,"unit":"mg/kg (pounds per million pounds) of concentrate digested","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","new sources (NSPS)","(e) Subpart K—Precipitation and Filtration Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.114 (NSPS)","page":null,"quote":"Fluoride 222.300 127.000"}},{"id":"0882f889af49b8ee","parameter":"Fluoride","value":"2,119.000","value_num":2119,"unit":"mg/kg (pounds per million pounds) of tantalum salt dried","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","new sources (NSPS)","(f) Subpart K—Tantalum Salt Drying.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.114 (NSPS)","page":null,"quote":"Fluoride 2,119.000 1,211.000"}},{"id":"8efb5838e2c28a7f","parameter":"Fluoride","value":"1,211.000","value_num":1211,"unit":"mg/kg (pounds per million pounds) of tantalum salt dried","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","new sources (NSPS)","(f) Subpart K—Tantalum Salt Drying.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.114 (NSPS)","page":null,"quote":"Fluoride 2,119.000 1,211.000"}},{"id":"646ca9ed09639db6","parameter":"Fluoride","value":"134.500","value_num":134.5,"unit":"mg/kg (pounds per million pounds) of columbium-tantalum oxide dried","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","new sources (NSPS)","(g) Subpart K—Oxides Calcining Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.114 (NSPS)","page":null,"quote":"Fluoride 134.500 76.840"}},{"id":"76153b4f7d90fa72","parameter":"Fluoride","value":"76.840","value_num":76.84,"unit":"mg/kg (pounds per million pounds) of columbium-tantalum oxide dried","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","new sources (NSPS)","(g) Subpart K—Oxides Calcining Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.114 (NSPS)","page":null,"quote":"Fluoride 134.500 76.840"}},{"id":"5efb08013bd7eaac","parameter":"Fluoride","value":"5,813.000","value_num":5813,"unit":"mg/kg (pounds per million pounds) of tantalum salt reduced","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:16984-48-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart K—Primary Columbium-Tantalum Subcategory","new sources (NSPS)","(h) Subpart K—Reduction of Tantalum Salt to Metal.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.114 (NSPS)","page":null,"quote":"Fluoride 5,813.000 3,322.000"}}],"next":[{"tool":"list_permits","says":"Who in this state went over on it? list_permits lists the state's permits whose last 12 months went over a limit on it, each with its record and its get_permit address; `get` is the address to fetch.","arguments":{"state":"FL","parameter":"fluoride"},"needs":{},"get":"https://passage-data.com/api/v1/permits?state=FL&parameter=fluoride","url":"https://passage-data.com/api/v1/permits?state=FL&parameter=fluoride"},{"tool":"check_values","says":"Has your user measured this? check_values sets each of their results beside every row held here, with a verdict and the row's cite.","arguments":{"place":"US-FL"},"needs":{"rows":"Your user's measured results, as their table prints them: [{parameter: \"fluoride\", value, unit}, ...], any other parameters too."},"post":"/api/v1/check","url":"https://passage-data.com/api/v1/check","page":"https://passage-data.com/limits/US-FL/fluoride#check"},{"tool":"read_certificate","says":"Has your user a laboratory certificate? read_certificate reads every row it prints, each with its page, and checks them against these limits.","arguments":{"place":"US-FL"},"needs":{"content_base64":"The laboratory's certificate (PDF) or its XLSX, XLS or CSV export, as base64; or file_url, a public https address of it."},"post":"/api/v1/certificate","url":"https://passage-data.com/api/v1/certificate","page":"https://passage-data.com/limits/US-FL/fluoride#check"}]}