{"query":{"parameter":"copper total","place":"US-MN","medium":null,"statistic":null,"kind":null},"searched":{"places":["US-MN","US"],"parameter_keys":["cas:7440-50-8","name:copper - total","name:copper, total","name:total copper","name:copper, total recoverable","name:arsenic, cadmium (h), copper (h), lead (h), mercury, zinc","name:arsenic, cadmium (h), copper (h), lead (h), zinc","name:cadmium (h), copper (h), mercury, lead (h), zinc","cas:68512-13-0","cas:544-92-3","name:cuivre extractible"],"names_matched":[["copper total","cas:7440-50-8"],["copper total","name:copper - total"],["copper total","name:copper, total"],["copper total","name:total copper"],["copper total recoverable","name:copper, total recoverable"],["arsenic cadmium h copper h lead h mercury zinc","name:arsenic, cadmium (h), copper (h), lead (h), mercury, zinc","copper"],["arsenic cadmium h copper h lead h mercury zinc h","name:arsenic, cadmium (h), copper (h), lead (h), mercury, zinc","copper"],["arsenic cadmium h copper h lead h zinc","name:arsenic, cadmium (h), copper (h), lead (h), zinc","copper"],["arsenic cadmium h copper h lead h zinc h","name:arsenic, cadmium (h), copper (h), lead (h), zinc","copper"],["cadmium h copper h mercury lead h zinc","name:cadmium (h), copper (h), mercury, lead (h), zinc","copper"],["cadmium h copper h mercury lead h zinc h","name:cadmium (h), copper (h), mercury, lead (h), zinc","copper"],["copper 29h 31h phthalocyaninato 2 kappa n29 kappa n30 kappa n31 kappa n32 brominated chlorinated","cas:68512-13-0","copper"],["copper cyanide","cas:544-92-3","copper"],["copper cyanide cu cn","cas:544-92-3","copper"],["copper cyanide cucn","cas:544-92-3","copper"],["copper i cyanide","cas:544-92-3","copper"],["total recoverable copper","name:copper, total recoverable","copper"],["cuivre extractible","name:cuivre extractible","cuivre"]],"match":"exact+contains","order":"The place's own instruments first, then each place above it, each in its register's order; rows for a marine receiving water after the rest, as none of the place's own rows names a marine, salt, estuarine, coastal or ocean water"},"total":2448,"offset":0,"returned":200,"next_offset":200,"permits_over":{"state":"MN","parameter":"copper total","permits":2,"list":"https://passage-data.com/api/v1/permits?state=MN&parameter=copper+total"},"rows":[{"id":"6c8ef59458f8eabb","parameter":"Copper, total","value":"exp.(0.620[ln(total hardness mg/L)]-0.570)","unit":"µg/L","statistic":"four_day_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2A waters: coldwater aquatic life and habitats, also protected as a source of drinking water (Minn. R. 7050.0222 subp. 2; each water's class is listed in 7050.0470)","total hardness-dependent: the printed equation; not evaluated"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 2","page":109,"quote":"The CS in μg/L shall not exceed: exp.(0.620[ln(total hardness mg/L)]-0.570)​"}},{"id":"edc1bcc07b23f818","parameter":"Copper, total","value":"exp.(0.9422[ln(total hardness mg/L)]-1.464)","unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2A waters: coldwater aquatic life and habitats, also protected as a source of drinking water (Minn. R. 7050.0222 subp. 2; each water's class is listed in 7050.0470)","total hardness-dependent: the printed equation; not evaluated"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 2","page":109,"quote":"The MS in μg/L shall not exceed: exp.(0.9422[ln(total hardness mg/L)]-1.464)​"}},{"id":"6fe446e9e877e7f8","parameter":"Copper, total","value":"exp.(0.9422[ln(total hardness mg/L)]-0.7703)","unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2A waters: coldwater aquatic life and habitats, also protected as a source of drinking water (Minn. R. 7050.0222 subp. 2; each water's class is listed in 7050.0470)","total hardness-dependent: the printed equation; not evaluated"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 2","page":109,"quote":"The FAV in μg/L shall not exceed: exp.(0.9422[ln(total hardness mg/L)]-0.7703)​"}},{"id":"91414b584a617f9f","parameter":"Copper, total","value":"6.4","value_num":6.4,"unit":"µg/L","statistic":"four_day_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2A waters: coldwater aquatic life and habitats, also protected as a source of drinking water (Minn. R. 7050.0222 subp. 2; each water's class is listed in 7050.0470)","total hardness 50 mg/L (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 2","page":109,"quote":"CS μg/L​ 6.4​ 9.8​ 15​ 19​ 23​"}},{"id":"8e51dfc8fb2815d2","parameter":"Copper, total","value":"9.8","value_num":9.8,"unit":"µg/L","statistic":"four_day_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2A waters: coldwater aquatic life and habitats, also protected as a source of drinking water (Minn. R. 7050.0222 subp. 2; each water's class is listed in 7050.0470)","total hardness 100 mg/L (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 2","page":109,"quote":"CS μg/L​ 6.4​ 9.8​ 15​ 19​ 23​"}},{"id":"551402c4d5de06e7","parameter":"Copper, total","value":"15","value_num":15,"unit":"µg/L","statistic":"four_day_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2A waters: coldwater aquatic life and habitats, also protected as a source of drinking water (Minn. R. 7050.0222 subp. 2; each water's class is listed in 7050.0470)","total hardness 200 mg/L (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 2","page":109,"quote":"CS μg/L​ 6.4​ 9.8​ 15​ 19​ 23​"}},{"id":"b4e202b0fa886ef0","parameter":"Copper, total","value":"19","value_num":19,"unit":"µg/L","statistic":"four_day_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2A waters: coldwater aquatic life and habitats, also protected as a source of drinking water (Minn. R. 7050.0222 subp. 2; each water's class is listed in 7050.0470)","total hardness 300 mg/L (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 2","page":109,"quote":"CS μg/L​ 6.4​ 9.8​ 15​ 19​ 23​"}},{"id":"639fffeebaf07491","parameter":"Copper, total","value":"23","value_num":23,"unit":"µg/L","statistic":"four_day_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2A waters: coldwater aquatic life and habitats, also protected as a source of drinking water (Minn. R. 7050.0222 subp. 2; each water's class is listed in 7050.0470)","total hardness 400 mg/L or above (above 400 mg/L, 400 mg/L is used)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 2","page":109,"quote":"CS μg/L​ 6.4​ 9.8​ 15​ 19​ 23​"}},{"id":"c19a26f447b9dd3f","parameter":"Copper, total","value":"9.2","value_num":9.2,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2A waters: coldwater aquatic life and habitats, also protected as a source of drinking water (Minn. R. 7050.0222 subp. 2; each water's class is listed in 7050.0470)","total hardness 50 mg/L (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 2","page":109,"quote":"MS μg/L​ 9.2​ 18​ 34​ 50​ 65​"}},{"id":"cdb414edffb5fd5c","parameter":"Copper, total","value":"18","value_num":18,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2A waters: coldwater aquatic life and habitats, also protected as a source of drinking water (Minn. R. 7050.0222 subp. 2; each water's class is listed in 7050.0470)","total hardness 100 mg/L (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 2","page":109,"quote":"MS μg/L​ 9.2​ 18​ 34​ 50​ 65​"}},{"id":"57f1e839e067b1f0","parameter":"Copper, total","value":"34","value_num":34,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2A waters: coldwater aquatic life and habitats, also protected as a source of drinking water (Minn. R. 7050.0222 subp. 2; each water's class is listed in 7050.0470)","total hardness 200 mg/L (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 2","page":109,"quote":"MS μg/L​ 9.2​ 18​ 34​ 50​ 65​"}},{"id":"133ec32e164659d6","parameter":"Copper, total","value":"50","value_num":50,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2A waters: coldwater aquatic life and habitats, also protected as a source of drinking water (Minn. R. 7050.0222 subp. 2; each water's class is listed in 7050.0470)","total hardness 300 mg/L (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 2","page":109,"quote":"MS μg/L​ 9.2​ 18​ 34​ 50​ 65​"}},{"id":"156797fc5d9707f1","parameter":"Copper, total","value":"65","value_num":65,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2A waters: coldwater aquatic life and habitats, also protected as a source of drinking water (Minn. R. 7050.0222 subp. 2; each water's class is listed in 7050.0470)","total hardness 400 mg/L or above (above 400 mg/L, 400 mg/L is used)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 2","page":109,"quote":"MS μg/L​ 9.2​ 18​ 34​ 50​ 65​"}},{"id":"623c9aec959f2582","parameter":"Copper, total","value":"18","value_num":18,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2A waters: coldwater aquatic life and habitats, also protected as a source of drinking water (Minn. R. 7050.0222 subp. 2; each water's class is listed in 7050.0470)","total hardness 50 mg/L (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 2","page":109,"quote":"FAV μg/L​ 18​ 35​ 68​ 100​ 131​"}},{"id":"3d8f9bcc54e00af5","parameter":"Copper, total","value":"35","value_num":35,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2A waters: coldwater aquatic life and habitats, also protected as a source of drinking water (Minn. R. 7050.0222 subp. 2; each water's class is listed in 7050.0470)","total hardness 100 mg/L (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 2","page":109,"quote":"FAV μg/L​ 18​ 35​ 68​ 100​ 131​"}},{"id":"2a037434b68f3d62","parameter":"Copper, total","value":"68","value_num":68,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2A waters: coldwater aquatic life and habitats, also protected as a source of drinking water (Minn. R. 7050.0222 subp. 2; each water's class is listed in 7050.0470)","total hardness 200 mg/L (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 2","page":109,"quote":"FAV μg/L​ 18​ 35​ 68​ 100​ 131​"}},{"id":"34e98090980c00d2","parameter":"Copper, total","value":"100","value_num":100,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2A waters: coldwater aquatic life and habitats, also protected as a source of drinking water (Minn. R. 7050.0222 subp. 2; each water's class is listed in 7050.0470)","total hardness 300 mg/L (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 2","page":109,"quote":"FAV μg/L​ 18​ 35​ 68​ 100​ 131​"}},{"id":"2478a5c435c87f80","parameter":"Copper, total","value":"131","value_num":131,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2A waters: coldwater aquatic life and habitats, also protected as a source of drinking water (Minn. R. 7050.0222 subp. 2; each water's class is listed in 7050.0470)","total hardness 400 mg/L or above (above 400 mg/L, 400 mg/L is used)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 2","page":109,"quote":"FAV μg/L​ 18​ 35​ 68​ 100​ 131​"}},{"id":"edd4c05896d36d12","parameter":"Copper, total","value":"exp.(0.620[ln(total hardness mg/L)]-0.570)","unit":"µg/L","statistic":"four_day_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2Bd waters: cool or warm water aquatic life and habitats, also protected as a source of drinking water (Minn. R. 7050.0222 subp. 3)","total hardness-dependent: the printed equation; not evaluated"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 3","page":123,"quote":"The CS in μg/L shall not exceed: exp.(0.620[ln(total hardness mg/L)]-0.570)​"}},{"id":"d8c8db91266569d2","parameter":"Copper, total","value":"exp.(0.9422[ln(total hardness mg/L)]-1.464)","unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2Bd waters: cool or warm water aquatic life and habitats, also protected as a source of drinking water (Minn. R. 7050.0222 subp. 3)","total hardness-dependent: the printed equation; not evaluated"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 3","page":123,"quote":"The MS in μg/L shall not exceed: exp.(0.9422[ln(total hardness mg/L)]-1.464)​"}},{"id":"58308e54710fdc7c","parameter":"Copper, total","value":"exp.(0.9422[ln(total hardness mg/L)]-0.7703)","unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2Bd waters: cool or warm water aquatic life and habitats, also protected as a source of drinking water (Minn. R. 7050.0222 subp. 3)","total hardness-dependent: the printed equation; not evaluated"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 3","page":123,"quote":"The FAV in μg/L shall not exceed: exp.(0.9422[ln(total hardness mg/L)]-0.7703)​"}},{"id":"60b11cf97d034bdb","parameter":"Copper, total","value":"6.4","value_num":6.4,"unit":"µg/L","statistic":"four_day_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2Bd waters: cool or warm water aquatic life and habitats, also protected as a source of drinking water (Minn. R. 7050.0222 subp. 3)","total hardness 50 mg/L (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 3","page":123,"quote":"CS μg/L​ 6.4​ 9.8​ 15​ 19​ 23​"}},{"id":"019b562a7fe3d252","parameter":"Copper, total","value":"9.8","value_num":9.8,"unit":"µg/L","statistic":"four_day_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2Bd waters: cool or warm water aquatic life and habitats, also protected as a source of drinking water (Minn. R. 7050.0222 subp. 3)","total hardness 100 mg/L (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 3","page":123,"quote":"CS μg/L​ 6.4​ 9.8​ 15​ 19​ 23​"}},{"id":"ab15d21dc81d58a7","parameter":"Copper, total","value":"15","value_num":15,"unit":"µg/L","statistic":"four_day_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2Bd waters: cool or warm water aquatic life and habitats, also protected as a source of drinking water (Minn. R. 7050.0222 subp. 3)","total hardness 200 mg/L (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 3","page":123,"quote":"CS μg/L​ 6.4​ 9.8​ 15​ 19​ 23​"}},{"id":"12d01cbdf520e217","parameter":"Copper, total","value":"19","value_num":19,"unit":"µg/L","statistic":"four_day_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2Bd waters: cool or warm water aquatic life and habitats, also protected as a source of drinking water (Minn. R. 7050.0222 subp. 3)","total hardness 300 mg/L (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 3","page":123,"quote":"CS μg/L​ 6.4​ 9.8​ 15​ 19​ 23​"}},{"id":"90202baa1b21b51b","parameter":"Copper, total","value":"23","value_num":23,"unit":"µg/L","statistic":"four_day_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2Bd waters: cool or warm water aquatic life and habitats, also protected as a source of drinking water (Minn. R. 7050.0222 subp. 3)","total hardness 400 mg/L or above (above 400 mg/L, 400 mg/L is used)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 3","page":123,"quote":"CS μg/L​ 6.4​ 9.8​ 15​ 19​ 23​"}},{"id":"fb23627f83c28604","parameter":"Copper, total","value":"9.2","value_num":9.2,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2Bd waters: cool or warm water aquatic life and habitats, also protected as a source of drinking water (Minn. R. 7050.0222 subp. 3)","total hardness 50 mg/L (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 3","page":123,"quote":"MS μg/L​ 9.2​ 18​ 34​ 50​ 65​"}},{"id":"caf2879f6ee5cc22","parameter":"Copper, total","value":"18","value_num":18,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2Bd waters: cool or warm water aquatic life and habitats, also protected as a source of drinking water (Minn. R. 7050.0222 subp. 3)","total hardness 100 mg/L (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 3","page":123,"quote":"MS μg/L​ 9.2​ 18​ 34​ 50​ 65​"}},{"id":"6d9ccb4de679d86e","parameter":"Copper, total","value":"34","value_num":34,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2Bd waters: cool or warm water aquatic life and habitats, also protected as a source of drinking water (Minn. R. 7050.0222 subp. 3)","total hardness 200 mg/L (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 3","page":123,"quote":"MS μg/L​ 9.2​ 18​ 34​ 50​ 65​"}},{"id":"1e1e2f14285e233b","parameter":"Copper, total","value":"50","value_num":50,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2Bd waters: cool or warm water aquatic life and habitats, also protected as a source of drinking water (Minn. R. 7050.0222 subp. 3)","total hardness 300 mg/L (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 3","page":123,"quote":"MS μg/L​ 9.2​ 18​ 34​ 50​ 65​"}},{"id":"ccd700b6f8c7c55e","parameter":"Copper, total","value":"65","value_num":65,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2Bd waters: cool or warm water aquatic life and habitats, also protected as a source of drinking water (Minn. R. 7050.0222 subp. 3)","total hardness 400 mg/L or above (above 400 mg/L, 400 mg/L is used)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 3","page":123,"quote":"MS μg/L​ 9.2​ 18​ 34​ 50​ 65​"}},{"id":"2706b9850a0e36a9","parameter":"Copper, total","value":"18","value_num":18,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2Bd waters: cool or warm water aquatic life and habitats, also protected as a source of drinking water (Minn. R. 7050.0222 subp. 3)","total hardness 50 mg/L (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 3","page":123,"quote":"FAV μg/L​ 18​ 35​ 68​ 100​ 131​"}},{"id":"6988f6b8943099ed","parameter":"Copper, total","value":"35","value_num":35,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2Bd waters: cool or warm water aquatic life and habitats, also protected as a source of drinking water (Minn. R. 7050.0222 subp. 3)","total hardness 100 mg/L (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 3","page":123,"quote":"FAV μg/L​ 18​ 35​ 68​ 100​ 131​"}},{"id":"d36735a9f56d9468","parameter":"Copper, total","value":"68","value_num":68,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2Bd waters: cool or warm water aquatic life and habitats, also protected as a source of drinking water (Minn. R. 7050.0222 subp. 3)","total hardness 200 mg/L (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 3","page":123,"quote":"FAV μg/L​ 18​ 35​ 68​ 100​ 131​"}},{"id":"a81904a236b09cea","parameter":"Copper, total","value":"100","value_num":100,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2Bd waters: cool or warm water aquatic life and habitats, also protected as a source of drinking water (Minn. R. 7050.0222 subp. 3)","total hardness 300 mg/L (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 3","page":123,"quote":"FAV μg/L​ 18​ 35​ 68​ 100​ 131​"}},{"id":"e90308c1788989e7","parameter":"Copper, total","value":"131","value_num":131,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2Bd waters: cool or warm water aquatic life and habitats, also protected as a source of drinking water (Minn. R. 7050.0222 subp. 3)","total hardness 400 mg/L or above (above 400 mg/L, 400 mg/L is used)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 3","page":123,"quote":"FAV μg/L​ 18​ 35​ 68​ 100​ 131​"}},{"id":"0c62e2e5a201ad79","parameter":"Copper, total","value":"exp.(0.6200[ln(total hardness mg/L)]-0.570)","unit":"µg/L","statistic":"four_day_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2B waters: cool or warm water aquatic life and habitats, not protected as a source of drinking water (Minn. R. 7050.0222 subp. 4); class 2D wetlands take these standards save dissolved oxygen, pH, temperature and chloride (subp. 6)","total hardness-dependent: the printed equation; not evaluated"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 4","page":140,"quote":"The CS in μg/L shall not exceed: exp.(0.6200[ln(total hardness mg/L)]-0.570)​"}},{"id":"ee838dbd15cbdc8d","parameter":"Copper, total","value":"exp.(0.9422[ln(total hardness mg/L)]-1.464)","unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2B waters: cool or warm water aquatic life and habitats, not protected as a source of drinking water (Minn. R. 7050.0222 subp. 4); class 2D wetlands take these standards save dissolved oxygen, pH, temperature and chloride (subp. 6)","total hardness-dependent: the printed equation; not evaluated"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 4","page":140,"quote":"The MS in μg/L shall not exceed: exp.(0.9422[ln(total hardness mg/L)]-1.464)​"}},{"id":"1da6ed3fb67e3145","parameter":"Copper, total","value":"exp.(0.9422[ln(total hardness mg/L)]-0.7703)","unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2B waters: cool or warm water aquatic life and habitats, not protected as a source of drinking water (Minn. R. 7050.0222 subp. 4); class 2D wetlands take these standards save dissolved oxygen, pH, temperature and chloride (subp. 6)","total hardness-dependent: the printed equation; not evaluated"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 4","page":140,"quote":"The FAV in μg/L shall not exceed: exp.(0.9422[ln(total hardness mg/L)]-0.7703)​"}},{"id":"4788d58b735c5b8e","parameter":"Copper, total","value":"6.4","value_num":6.4,"unit":"µg/L","statistic":"four_day_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2B waters: cool or warm water aquatic life and habitats, not protected as a source of drinking water (Minn. R. 7050.0222 subp. 4); class 2D wetlands take these standards save dissolved oxygen, pH, temperature and chloride (subp. 6)","total hardness 50 mg/L (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 4","page":140,"quote":"CS μg/L​ 6.4​ 9.8​ 15​ 19​ 23​"}},{"id":"7a7c2bb2e655f87e","parameter":"Copper, total","value":"9.8","value_num":9.8,"unit":"µg/L","statistic":"four_day_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2B waters: cool or warm water aquatic life and habitats, not protected as a source of drinking water (Minn. R. 7050.0222 subp. 4); class 2D wetlands take these standards save dissolved oxygen, pH, temperature and chloride (subp. 6)","total hardness 100 mg/L (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 4","page":140,"quote":"CS μg/L​ 6.4​ 9.8​ 15​ 19​ 23​"}},{"id":"d41bae2018ba794c","parameter":"Copper, total","value":"15","value_num":15,"unit":"µg/L","statistic":"four_day_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2B waters: cool or warm water aquatic life and habitats, not protected as a source of drinking water (Minn. R. 7050.0222 subp. 4); class 2D wetlands take these standards save dissolved oxygen, pH, temperature and chloride (subp. 6)","total hardness 200 mg/L (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 4","page":140,"quote":"CS μg/L​ 6.4​ 9.8​ 15​ 19​ 23​"}},{"id":"9e4aa8b35c112aa5","parameter":"Copper, total","value":"19","value_num":19,"unit":"µg/L","statistic":"four_day_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2B waters: cool or warm water aquatic life and habitats, not protected as a source of drinking water (Minn. R. 7050.0222 subp. 4); class 2D wetlands take these standards save dissolved oxygen, pH, temperature and chloride (subp. 6)","total hardness 300 mg/L (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 4","page":140,"quote":"CS μg/L​ 6.4​ 9.8​ 15​ 19​ 23​"}},{"id":"2978812988cb4e98","parameter":"Copper, total","value":"23","value_num":23,"unit":"µg/L","statistic":"four_day_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2B waters: cool or warm water aquatic life and habitats, not protected as a source of drinking water (Minn. R. 7050.0222 subp. 4); class 2D wetlands take these standards save dissolved oxygen, pH, temperature and chloride (subp. 6)","total hardness 400 mg/L or above (above 400 mg/L, 400 mg/L is used)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 4","page":140,"quote":"CS μg/L​ 6.4​ 9.8​ 15​ 19​ 23​"}},{"id":"4084a902ec2501e2","parameter":"Copper, total","value":"9.2","value_num":9.2,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2B waters: cool or warm water aquatic life and habitats, not protected as a source of drinking water (Minn. R. 7050.0222 subp. 4); class 2D wetlands take these standards save dissolved oxygen, pH, temperature and chloride (subp. 6)","total hardness 50 mg/L (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 4","page":140,"quote":"MS μg/L​ 9.2​ 18​ 34​ 50​ 65​"}},{"id":"bebb9e3e91ccca3b","parameter":"Copper, total","value":"18","value_num":18,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2B waters: cool or warm water aquatic life and habitats, not protected as a source of drinking water (Minn. R. 7050.0222 subp. 4); class 2D wetlands take these standards save dissolved oxygen, pH, temperature and chloride (subp. 6)","total hardness 100 mg/L (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 4","page":140,"quote":"MS μg/L​ 9.2​ 18​ 34​ 50​ 65​"}},{"id":"18c12210900d5d3f","parameter":"Copper, total","value":"34","value_num":34,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2B waters: cool or warm water aquatic life and habitats, not protected as a source of drinking water (Minn. R. 7050.0222 subp. 4); class 2D wetlands take these standards save dissolved oxygen, pH, temperature and chloride (subp. 6)","total hardness 200 mg/L (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 4","page":140,"quote":"MS μg/L​ 9.2​ 18​ 34​ 50​ 65​"}},{"id":"cd319b1eea8de097","parameter":"Copper, total","value":"50","value_num":50,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2B waters: cool or warm water aquatic life and habitats, not protected as a source of drinking water (Minn. R. 7050.0222 subp. 4); class 2D wetlands take these standards save dissolved oxygen, pH, temperature and chloride (subp. 6)","total hardness 300 mg/L (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 4","page":140,"quote":"MS μg/L​ 9.2​ 18​ 34​ 50​ 65​"}},{"id":"e31b229192b7a8b3","parameter":"Copper, total","value":"65","value_num":65,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2B waters: cool or warm water aquatic life and habitats, not protected as a source of drinking water (Minn. R. 7050.0222 subp. 4); class 2D wetlands take these standards save dissolved oxygen, pH, temperature and chloride (subp. 6)","total hardness 400 mg/L or above (above 400 mg/L, 400 mg/L is used)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 4","page":140,"quote":"MS μg/L​ 9.2​ 18​ 34​ 50​ 65​"}},{"id":"70bee19bcddfa230","parameter":"Copper, total","value":"18","value_num":18,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2B waters: cool or warm water aquatic life and habitats, not protected as a source of drinking water (Minn. R. 7050.0222 subp. 4); class 2D wetlands take these standards save dissolved oxygen, pH, temperature and chloride (subp. 6)","total hardness 50 mg/L (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 4","page":140,"quote":"FAV μg/L​ 18​ 35​ 68​ 100​ 131​"}},{"id":"d47b73d322f09245","parameter":"Copper, total","value":"35","value_num":35,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2B waters: cool or warm water aquatic life and habitats, not protected as a source of drinking water (Minn. R. 7050.0222 subp. 4); class 2D wetlands take these standards save dissolved oxygen, pH, temperature and chloride (subp. 6)","total hardness 100 mg/L (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 4","page":140,"quote":"FAV μg/L​ 18​ 35​ 68​ 100​ 131​"}},{"id":"c28735844a4db883","parameter":"Copper, total","value":"68","value_num":68,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2B waters: cool or warm water aquatic life and habitats, not protected as a source of drinking water (Minn. R. 7050.0222 subp. 4); class 2D wetlands take these standards save dissolved oxygen, pH, temperature and chloride (subp. 6)","total hardness 200 mg/L (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 4","page":140,"quote":"FAV μg/L​ 18​ 35​ 68​ 100​ 131​"}},{"id":"c98568b04c7a409e","parameter":"Copper, total","value":"100","value_num":100,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2B waters: cool or warm water aquatic life and habitats, not protected as a source of drinking water (Minn. R. 7050.0222 subp. 4); class 2D wetlands take these standards save dissolved oxygen, pH, temperature and chloride (subp. 6)","total hardness 300 mg/L (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 4","page":140,"quote":"FAV μg/L​ 18​ 35​ 68​ 100​ 131​"}},{"id":"ede9b9ac41f2920e","parameter":"Copper, total","value":"131","value_num":131,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","class 2B waters: cool or warm water aquatic life and habitats, not protected as a source of drinking water (Minn. R. 7050.0222 subp. 4); class 2D wetlands take these standards save dissolved oxygen, pH, temperature and chloride (subp. 6)","total hardness 400 mg/L or above (above 400 mg/L, 400 mg/L is used)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7050.0222 subp. 4","page":140,"quote":"FAV μg/L​ 18​ 35​ 68​ 100​ 131​"}},{"id":"9a8fda6bcbc98901","parameter":"Copper, total","value":"exp.(0.8545[ln (TH mg/l)]-1.702)","unit":"µg/L","statistic":"four_day_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","the Lake Superior basin (Minn. R. ch. 7052)","all surface waters of the Lake Superior basin (subp. 6 A)","total hardness-dependent: the printed formula; not evaluated"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7052.0100 subp. 6","page":19,"quote":"Chronic standard​ exp.(0.8545[ln (TH mg/l)]-1.702)​ 5.2​ 9.3​ 17​ 24​ 30​"}},{"id":"dc2a38ed73a6b6fa","parameter":"Copper, total","value":"5.2","value_num":5.2,"unit":"µg/L","statistic":"four_day_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","the Lake Superior basin (Minn. R. ch. 7052)","all surface waters of the Lake Superior basin (subp. 6 A)","total hardness 50 mg/l (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7052.0100 subp. 6","page":19,"quote":"Chronic standard​ exp.(0.8545[ln (TH mg/l)]-1.702)​ 5.2​ 9.3​ 17​ 24​ 30​"}},{"id":"42ab60a348d4981f","parameter":"Copper, total","value":"9.3","value_num":9.3,"unit":"µg/L","statistic":"four_day_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","the Lake Superior basin (Minn. R. ch. 7052)","all surface waters of the Lake Superior basin (subp. 6 A)","total hardness 100 mg/l (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7052.0100 subp. 6","page":19,"quote":"Chronic standard​ exp.(0.8545[ln (TH mg/l)]-1.702)​ 5.2​ 9.3​ 17​ 24​ 30​"}},{"id":"11dbc06ec92a3778","parameter":"Copper, total","value":"17","value_num":17,"unit":"µg/L","statistic":"four_day_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","the Lake Superior basin (Minn. R. ch. 7052)","all surface waters of the Lake Superior basin (subp. 6 A)","total hardness 200 mg/l (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7052.0100 subp. 6","page":19,"quote":"Chronic standard​ exp.(0.8545[ln (TH mg/l)]-1.702)​ 5.2​ 9.3​ 17​ 24​ 30​"}},{"id":"e6dcbf3fc87ece08","parameter":"Copper, total","value":"24","value_num":24,"unit":"µg/L","statistic":"four_day_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","the Lake Superior basin (Minn. R. ch. 7052)","all surface waters of the Lake Superior basin (subp. 6 A)","total hardness 300 mg/l (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7052.0100 subp. 6","page":19,"quote":"Chronic standard​ exp.(0.8545[ln (TH mg/l)]-1.702)​ 5.2​ 9.3​ 17​ 24​ 30​"}},{"id":"2ddc8ce52fc15744","parameter":"Copper, total","value":"30","value_num":30,"unit":"µg/L","statistic":"four_day_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","the Lake Superior basin (Minn. R. ch. 7052)","all surface waters of the Lake Superior basin (subp. 6 A)","total hardness 400 mg/l or above (above 400, 400 is used)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7052.0100 subp. 6","page":19,"quote":"Chronic standard​ exp.(0.8545[ln (TH mg/l)]-1.702)​ 5.2​ 9.3​ 17​ 24​ 30​"}},{"id":"d545e2780f1b2486","parameter":"Copper, total","value":"exp.(0.9422[ln (TH mg/l)]-1.700)","unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","the Lake Superior basin (Minn. R. ch. 7052)","all surface waters of the Lake Superior basin (subp. 6 A)","total hardness-dependent: the printed formula; not evaluated"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7052.0100 subp. 6","page":19,"quote":"Maximum standard​ exp.(0.9422[ln (TH mg/l)]-1.700)​ 7.3​ 14​ 27​ 39​ 52​"}},{"id":"23cdcf4b4b15ac67","parameter":"Copper, total","value":"7.3","value_num":7.3,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","the Lake Superior basin (Minn. R. ch. 7052)","all surface waters of the Lake Superior basin (subp. 6 A)","total hardness 50 mg/l (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7052.0100 subp. 6","page":19,"quote":"Maximum standard​ exp.(0.9422[ln (TH mg/l)]-1.700)​ 7.3​ 14​ 27​ 39​ 52​"}},{"id":"f6acd23d7ff44b10","parameter":"Copper, total","value":"14","value_num":14,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","the Lake Superior basin (Minn. R. ch. 7052)","all surface waters of the Lake Superior basin (subp. 6 A)","total hardness 100 mg/l (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7052.0100 subp. 6","page":19,"quote":"Maximum standard​ exp.(0.9422[ln (TH mg/l)]-1.700)​ 7.3​ 14​ 27​ 39​ 52​"}},{"id":"34dbbdfcef7b6891","parameter":"Copper, total","value":"27","value_num":27,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","the Lake Superior basin (Minn. R. ch. 7052)","all surface waters of the Lake Superior basin (subp. 6 A)","total hardness 200 mg/l (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7052.0100 subp. 6","page":19,"quote":"Maximum standard​ exp.(0.9422[ln (TH mg/l)]-1.700)​ 7.3​ 14​ 27​ 39​ 52​"}},{"id":"b5846ddd87fb8981","parameter":"Copper, total","value":"39","value_num":39,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","the Lake Superior basin (Minn. R. ch. 7052)","all surface waters of the Lake Superior basin (subp. 6 A)","total hardness 300 mg/l (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7052.0100 subp. 6","page":19,"quote":"Maximum standard​ exp.(0.9422[ln (TH mg/l)]-1.700)​ 7.3​ 14​ 27​ 39​ 52​"}},{"id":"023e1d39cab4edeb","parameter":"Copper, total","value":"52","value_num":52,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","the Lake Superior basin (Minn. R. ch. 7052)","all surface waters of the Lake Superior basin (subp. 6 A)","total hardness 400 mg/l or above (above 400, 400 is used)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7052.0100 subp. 6","page":19,"quote":"Maximum standard​ exp.(0.9422[ln (TH mg/l)]-1.700)​ 7.3​ 14​ 27​ 39​ 52​"}},{"id":"b74bccfe1c921f43","parameter":"Copper, total","value":"exp.(0.9422[ln (TH mg/l)]-1.0069)","unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","the Lake Superior basin (Minn. R. ch. 7052)","all surface waters of the Lake Superior basin (subp. 6 A)","total hardness-dependent: the printed formula; not evaluated"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7052.0100 subp. 6","page":19,"quote":"Final acute value​ exp.(0.9422[ln (TH mg/l)]-1.0069)​ 15​ 28​ 54​ 79​ 103​"}},{"id":"9cd511df5c24b44e","parameter":"Copper, total","value":"15","value_num":15,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","the Lake Superior basin (Minn. R. ch. 7052)","all surface waters of the Lake Superior basin (subp. 6 A)","total hardness 50 mg/l (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7052.0100 subp. 6","page":19,"quote":"Final acute value​ exp.(0.9422[ln (TH mg/l)]-1.0069)​ 15​ 28​ 54​ 79​ 103​"}},{"id":"a680795ff2a9e5fa","parameter":"Copper, total","value":"28","value_num":28,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","the Lake Superior basin (Minn. R. ch. 7052)","all surface waters of the Lake Superior basin (subp. 6 A)","total hardness 100 mg/l (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7052.0100 subp. 6","page":19,"quote":"Final acute value​ exp.(0.9422[ln (TH mg/l)]-1.0069)​ 15​ 28​ 54​ 79​ 103​"}},{"id":"ee7970ab7bc5367e","parameter":"Copper, total","value":"54","value_num":54,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","the Lake Superior basin (Minn. R. ch. 7052)","all surface waters of the Lake Superior basin (subp. 6 A)","total hardness 200 mg/l (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7052.0100 subp. 6","page":19,"quote":"Final acute value​ exp.(0.9422[ln (TH mg/l)]-1.0069)​ 15​ 28​ 54​ 79​ 103​"}},{"id":"214395614ba24717","parameter":"Copper, total","value":"79","value_num":79,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","the Lake Superior basin (Minn. R. ch. 7052)","all surface waters of the Lake Superior basin (subp. 6 A)","total hardness 300 mg/l (the rule's example)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7052.0100 subp. 6","page":19,"quote":"Final acute value​ exp.(0.9422[ln (TH mg/l)]-1.0069)​ 15​ 28​ 54​ 79​ 103​"}},{"id":"8df6ddc66847c3d6","parameter":"Copper, total","value":"103","value_num":103,"unit":"µg/L","statistic":"daily_avg","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"name:copper, total","place":["US-MN"],"conditions":["receiving_water is freshwater","the Lake Superior basin (Minn. R. ch. 7052)","all surface waters of the Lake Superior basin (subp. 6 A)","total hardness 400 mg/l or above (above 400, 400 is used)"],"cite":{"instrument":"us_mn_wqs","title":"Minnesota Rules ch. 7050 class 2 (2A, 2Bd, 2B/2D), class 4 and class 5 water quality standards, and ch. 7052 Lake Superior basin standards for GLI pollutants","issuer":"State of Minnesota, Pollution Control Agency","edition":"ch. 7050 as US EPA posts it in effect for CWA purposes (effective July 23, 2025; posting cover July 29, 2025), and ch. 7052 (effective June 26, 2018; Revisor publication 2017)","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/mnwqs-chapter-7050.pdf","source_sha256":"1d4e781bf7b39a79bf6ea8ce64daaa05bb6c4bd5b04a98219d606ae88dbac150","fetched_at":"2026-10-14","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"Minn. R. 7052.0100 subp. 6","page":19,"quote":"Final acute value​ exp.(0.9422[ln (TH mg/l)]-1.0069)​ 15​ 28​ 54​ 79​ 103​"}},{"id":"256b028254b2bd82","parameter":"Cu","value":"4.5","value_num":4.5,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"16008a3c68209ada","parameter":"Cu","value":"2.7","value_num":2.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"22cbbea24b9da5bd","parameter":"Cu","value":"176","value_num":176,"unit":"mg/sq m-Operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may be applied in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"e21e1440752d2fc6","parameter":"Cu","value":"105","value_num":105,"unit":"mg/sq m-Operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart A—Electroplating of Common Metals Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may be applied in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart A—Common Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.14 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"6ea14ea54f3404ca","parameter":"Cu","value":"4.5","value_num":4.5,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"40fa2c2f9b66b590","parameter":"Cu","value":"2.7","value_num":2.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"ed2ccb34fe0adb7b","parameter":"Cu","value":"176","value_num":176,"unit":"mg/sq m-Operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"f145e8fc6f26a53d","parameter":"Cu","value":"105","value_num":105,"unit":"mg/sq m-Operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart B—Electroplating of Precious Metals Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart B—Precious Metals Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-Operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.24 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"5c6869e8f7ce9806","parameter":"Cu","value":"4.5","value_num":4.5,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart D—Anodizing Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.44 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"6dd371e566f55874","parameter":"Cu","value":"2.7","value_num":2.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart D—Anodizing Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.44 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"6352db9ea086c87e","parameter":"Cu","value":"176","value_num":176,"unit":"mg/sq m-operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart D—Anodizing Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.44 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"119d18207921d6c5","parameter":"Cu","value":"105","value_num":105,"unit":"mg/sq m-operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart D—Anodizing Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart D—Anodizing Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.44 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"a04eb045e0431ca0","parameter":"Cu","value":"4.5","value_num":4.5,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart E—Coatings Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart E—Coatings Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.54 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"d5e0c3452c44b939","parameter":"Cu","value":"2.7","value_num":2.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart E—Coatings Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart E—Coatings Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.54 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"98efabf4c365118e","parameter":"Cu","value":"176","value_num":176,"unit":"mg/sq m-operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart E—Coatings Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart E—Coatings Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.54 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"84cb6bb97d7e1abe","parameter":"Cu","value":"105","value_num":105,"unit":"mg/sq m-operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart E—Coatings Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart E—Coatings Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.54 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"b46fca74c592bbf3","parameter":"Cu","value":"4.5","value_num":4.5,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart F—Chemical Etching and Milling Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal.) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart F—Chemicals Etching and Milling Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.64 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"0a4e32ffeb266cc6","parameter":"Cu","value":"2.7","value_num":2.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart F—Chemical Etching and Milling Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal.) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart F—Chemicals Etching and Milling Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.64 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"26dd6ba74da398d9","parameter":"Cu","value":"176","value_num":176,"unit":"mg/sq m-operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart F—Chemical Etching and Milling Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart F—Chemical Etching and Milling Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.64 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"80c73ca2b7b8171a","parameter":"Cu","value":"105","value_num":105,"unit":"mg/sq m-operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart F—Chemical Etching and Milling Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart F—Chemical Etching and Milling Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.64 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"22bdccfc00a3f2f4","parameter":"Cu","value":"4.5","value_num":4.5,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart G—Electroless Plating Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 l (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart G—Electroless Plating Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.74 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"13e953b81a11b746","parameter":"Cu","value":"2.7","value_num":2.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart G—Electroless Plating Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 l (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart G—Electroless Plating Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.74 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"302ae1967556fe7e","parameter":"Cu","value":"176","value_num":176,"unit":"mg/sq m-operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart G—Electroless Plating Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart G—Electroless Plating Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.74 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"6e74633e7b275fb3","parameter":"Cu","value":"105","value_num":105,"unit":"mg/sq m-operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart G—Electroless Plating Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart G—Electroless Plating Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.74 (PSES)","page":null,"quote":"Cu 176 105"}},{"id":"b57973496f4c755d","parameter":"Cu","value":"4.5","value_num":4.5,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart H—Printed Circuit Board Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart H—Printed Circuit Board Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.84 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"6ae65dbc345850e8","parameter":"Cu","value":"2.7","value_num":2.7,"unit":"mg/L","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart H—Printed Circuit Board Subcategory","existing sources (PSES)","(c) For plants discharging 38,000 liters (10,000 gal) or more per calendar day of electroplating process wastewater the following limitations shall apply:","table: Subpart H—Printed Circuit Board Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/l)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.84 (PSES)","page":null,"quote":"Cu 4.5 2.7"}},{"id":"005c56a3cfc79e0b","parameter":"Cu","value":"401","value_num":401,"unit":"mg/sq m-operation","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart H—Printed Circuit Board Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart H—Printed Circuit Board Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.84 (PSES)","page":null,"quote":"Cu 401 241"}},{"id":"943febff3ebef50f","parameter":"Cu","value":"241","value_num":241,"unit":"mg/sq m-operation","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 413","the discharge is of the Subpart H—Printed Circuit Board Subcategory","existing sources (PSES)","(d) Alternatively, the following mass-based standards are equivalent to and may apply in place of those limitations specified under paragraph (c) of this section upon prior agreement between a source subject to these standards and the publicly owned treatment works receiving such regulated wastes:","table: Subpart H—Printed Circuit Board Facilities Discharging 38,000 Liters or More Per Day PSES Limitations (mg/sq m-operation)"],"cite":{"instrument":"us_40cfr413","title":"40 CFR Part 413 — PART 413—ELECTROPLATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=413","source_sha256":"9c6c38baf048e0e1ed5f2c05df397ea581d48822b23c4b294e52b960b2d547f9","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 413.84 (PSES)","page":null,"quote":"Cu 401 241"}},{"id":"036e4093649d6c33","parameter":"Total Copper","value":"3,380","value_num":3380,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment","existing sources (BAT)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 414.91 (BAT)","page":null,"quote":"Total Copper 3,380 1,450"}},{"id":"0470f7ffd030047d","parameter":"Total Copper","value":"3,380","value_num":3380,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment","new sources (NSPS)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 414.91 (NSPS)","page":null,"quote":"Total Copper 3,380 1,450"}},{"id":"10b18d87908d1d1f","parameter":"Total Copper","value":"1,450","value_num":1450,"unit":"µg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment","existing sources (BAT)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 414.91 (BAT)","page":null,"quote":"Total Copper 3,380 1,450"}},{"id":"92494cc88bb23b04","parameter":"Total Copper","value":"1,450","value_num":1450,"unit":"µg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart I—Direct Discharge Point Sources That Use End-of-Pipe Biological Treatment","new sources (NSPS)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal-bearing waste streams for the metals and times the flow from cyanide bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearin…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 414.91 (NSPS)","page":null,"quote":"Total Copper 3,380 1,450"}},{"id":"561dd36d9452bbfe","parameter":"Total Copper","value":"3,380","value_num":3380,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment","existing sources (BAT)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 414.101 (BAT)","page":null,"quote":"Total Copper 3,380 1,450"}},{"id":"95ee697f99c92d7a","parameter":"Total Copper","value":"3,380","value_num":3380,"unit":"µg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment","new sources (NSPS)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 414.101 (NSPS)","page":null,"quote":"Total Copper 3,380 1,450"}},{"id":"4760e5810eebca73","parameter":"Total Copper","value":"1,450","value_num":1450,"unit":"µg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment","existing sources (BAT)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 414.101 (BAT)","page":null,"quote":"Total Copper 3,380 1,450"}},{"id":"ca638e1a500d7203","parameter":"Total Copper","value":"1,450","value_num":1450,"unit":"µg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["(a) The provisions of this part are applicable to process wastewater discharges from all establishments or portions of establishments that manufacture the organic chemicals, plastics, and synthetic fibers (OCPSF) products or product groups covered by subparts B through H of this regulation and are i","route is direct","cites is 40 CFR 414","the discharge is of the Subpart J—Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment","new sources (NSPS)","(b) In the case of chromium, copper, lead, nickel, zinc, and total cyanide, the discharge quantity (mass) shall be determined by multiplying the concentrations listed in the following table for these pollutants times the flow from metal bearing waste streams for the metals and times the cyanide-bearing waste streams for total cyanide. The metal-bearing waste streams and cyanide-bearing waste st…"],"cite":{"instrument":"us_40cfr414","title":"40 CFR Part 414 — PART 414—ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=414","source_sha256":"8652d1f3d1271a60d9c07a11c5e00c0c1e23da3fb57f25d86e40b9a487b25608","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 414.101 (NSPS)","page":null,"quote":"Total Copper 3,380 1,450"}},{"id":"cb2caa88ac7bf5ac","parameter":"Copper (T)","value":"0.018","value_num":0.018,"unit":"Kg/kkg (or pounds per/1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart F—Chlor-alkali Subcategory (Chlorine and Sodium or Potassium Hydroxide Production)","existing sources (BPT)","table: Subpart F—Chlor-Alkali Diaphragm Cells"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.62 (BPT)","page":null,"quote":"Copper (T) 0.018 0.0070"}},{"id":"a65962785d0deea9","parameter":"Copper (T)","value":"0.0070","value_num":0.007,"unit":"Kg/kkg (or pounds per/1,000 lb) of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart F—Chlor-alkali Subcategory (Chlorine and Sodium or Potassium Hydroxide Production)","existing sources (BPT)","table: Subpart F—Chlor-Alkali Diaphragm Cells"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.62 (BPT)","page":null,"quote":"Copper (T) 0.018 0.0070"}},{"id":"38449ffd7cf646c7","parameter":"Copper (T)","value":"0.012","value_num":0.012,"unit":"Kg/kkg (or pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart F—Chlor-alkali Subcategory (Chlorine and Sodium or Potassium Hydroxide Production)","existing sources (BAT)","table: Subpart F—Chlor-Alkali-Diaphragm Cells"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.63 (BAT)","page":null,"quote":"Copper (T) 0.012 0.0049"}},{"id":"78b264935168569c","parameter":"Copper (T)","value":"0.0049","value_num":0.0049,"unit":"Kg/kkg (or pounds per 1,000 lb) of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart F—Chlor-alkali Subcategory (Chlorine and Sodium or Potassium Hydroxide Production)","existing sources (BAT)","table: Subpart F—Chlor-Alkali-Diaphragm Cells"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.63 (BAT)","page":null,"quote":"Copper (T) 0.012 0.0049"}},{"id":"47a7d51859b30e2a","parameter":"Copper (T)","value":"2.1","value_num":2.1,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart F—Chlor-alkali Subcategory (Chlorine and Sodium or Potassium Hydroxide Production)","existing sources (PSES)","table: Subpart F—Chlor-Alkali-Diaphragm Cells"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.64 (PSES)","page":null,"quote":"Copper (T) 2.1 0.80"}},{"id":"eb1d3e19bbda406b","parameter":"Copper (T)","value":"0.80","value_num":0.8,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart F—Chlor-alkali Subcategory (Chlorine and Sodium or Potassium Hydroxide Production)","existing sources (PSES)","table: Subpart F—Chlor-Alkali-Diaphragm Cells"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.64 (PSES)","page":null,"quote":"Copper (T) 2.1 0.80"}},{"id":"90eec067ffd67c55","parameter":"Copper (T)","value":"0.0030","value_num":0.003,"unit":"Kg/kkg (or pounds per/1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart AJ—Copper Salts Production Subcategory","existing sources (BPT)","table: Subpart AJ—Copper Sulfate, Copper Chloride, Copper Iodide, Copper Nitrate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.362 (BPT)","page":null,"quote":"Copper (T) 0.0030 0.0010"}},{"id":"f9c1432fe386294b","parameter":"Copper (T)","value":"0.0010","value_num":0.001,"unit":"Kg/kkg (or pounds per/1,000 lb) of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart AJ—Copper Salts Production Subcategory","existing sources (BPT)","table: Subpart AJ—Copper Sulfate, Copper Chloride, Copper Iodide, Copper Nitrate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.362 (BPT)","page":null,"quote":"Copper (T) 0.0030 0.0010"}},{"id":"141cb29a847d8120","parameter":"Copper (T)","value":"0.19","value_num":0.19,"unit":"Kg/kkg (or pounds per/1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart AJ—Copper Salts Production Subcategory","existing sources (BPT)","table: Subpart AJ—Copper Carbonate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.362 (BPT)","page":null,"quote":"Copper (T) 0.19 0.064"}},{"id":"fec8fdc782d354ac","parameter":"Copper (T)","value":"0.064","value_num":0.064,"unit":"Kg/kkg (or pounds per/1,000 lb) of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart AJ—Copper Salts Production Subcategory","existing sources (BPT)","table: Subpart AJ—Copper Carbonate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.362 (BPT)","page":null,"quote":"Copper (T) 0.19 0.064"}},{"id":"f499deb127bd0af0","parameter":"Copper(T)","value":"3.2","value_num":3.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart AJ—Copper Salts Production Subcategory","existing sources (PSES)","table: Subpart AJ—Copper Sulfate, Copper Chloride, Copper Iodide, Copper Nitrate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.364 (PSES)","page":null,"quote":"Copper(T) 3.2 1.1"}},{"id":"872e4fa5cad742f2","parameter":"Copper(T)","value":"1.1","value_num":1.1,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart AJ—Copper Salts Production Subcategory","existing sources (PSES)","table: Subpart AJ—Copper Sulfate, Copper Chloride, Copper Iodide, Copper Nitrate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.364 (PSES)","page":null,"quote":"Copper(T) 3.2 1.1"}},{"id":"9ee3c2dcc9432d9c","parameter":"Copper (T)","value":"3.2","value_num":3.2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart AJ—Copper Salts Production Subcategory","existing sources (PSES)","table: Subpart AJ—Copper Carbonate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.364 (PSES)","page":null,"quote":"Copper (T) 3.2 1.1"}},{"id":"0d4cce7f782d1f28","parameter":"Copper (T)","value":"1.1","value_num":1.1,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart AJ—Copper Salts Production Subcategory","existing sources (PSES)","table: Subpart AJ—Copper Carbonate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.364 (PSES)","page":null,"quote":"Copper (T) 3.2 1.1"}},{"id":"182a11c0543448ff","parameter":"Copper (T)","value":"1.0","value_num":1,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart AL—Ferric Chloride Production Subcategory","existing sources (PSES)","table: Subpart AL—Ferric Chloride"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.384 (PSES)","page":null,"quote":"Copper (T) 1.0 0.50"}},{"id":"8103db562258c283","parameter":"Copper (T)","value":"0.50","value_num":0.5,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart AL—Ferric Chloride Production Subcategory","existing sources (PSES)","table: Subpart AL—Ferric Chloride"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.384 (PSES)","page":null,"quote":"Copper (T) 1.0 0.50"}},{"id":"24a40220639f6f98","parameter":"Copper (T)","value":"0.00074","value_num":0.00074,"unit":"Kg/kkg (or pounds per/1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart AU—Nickel Salts Production Subcategory","existing sources (BAT)","table: Subpart AU—Nickel Sulfate, Nickel Chloride, Nickel Nitrate, Nickel Fluoborate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.473 (BAT)","page":null,"quote":"Copper (T) 0.00074 0.00024"}},{"id":"7a54d9f52db666d0","parameter":"Copper (T)","value":"0.00024","value_num":0.00024,"unit":"Kg/kkg (or pounds per/1,000 lb) of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart AU—Nickel Salts Production Subcategory","existing sources (BAT)","table: Subpart AU—Nickel Sulfate, Nickel Chloride, Nickel Nitrate, Nickel Fluoborate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.473 (BAT)","page":null,"quote":"Copper (T) 0.00074 0.00024"}},{"id":"e575dea87ad3cd61","parameter":"Copper (T)","value":"0.13","value_num":0.13,"unit":"Kg/kkg (or pounds per/1,000 lb) or product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart AU—Nickel Salts Production Subcategory","existing sources (BAT)","table: Subpart AU—Nickel Carbonate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.473 (BAT)","page":null,"quote":"Copper (T) 0.13 0.042"}},{"id":"c8b8bb186d615886","parameter":"Copper (T)","value":"0.042","value_num":0.042,"unit":"Kg/kkg (or pounds per/1,000 lb) or product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart AU—Nickel Salts Production Subcategory","existing sources (BAT)","table: Subpart AU—Nickel Carbonate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.473 (BAT)","page":null,"quote":"Copper (T) 0.13 0.042"}},{"id":"7aa68ada04ba022f","parameter":"Copper(T)","value":"1.1","value_num":1.1,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart AU—Nickel Salts Production Subcategory","existing sources (PSES)","table: Subpart AU—Nickel Sulfate, Nickel Chloride, Nickel Nitrate, Nickel Fluoborate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.474 (PSES)","page":null,"quote":"Copper(T) 1.1 0.36"}},{"id":"98d3396498591530","parameter":"Copper(T)","value":"0.36","value_num":0.36,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart AU—Nickel Salts Production Subcategory","existing sources (PSES)","table: Subpart AU—Nickel Sulfate, Nickel Chloride, Nickel Nitrate, Nickel Fluoborate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.474 (PSES)","page":null,"quote":"Copper(T) 1.1 0.36"}},{"id":"1dadb03e5ead13bc","parameter":"Copper(T)","value":"1.1","value_num":1.1,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart AU—Nickel Salts Production Subcategory","existing sources (PSES)","table: Subpart AU—Nickel Carbonate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.474 (PSES)","page":null,"quote":"Copper(T) 1.1 0.36"}},{"id":"f693f8a4617f5705","parameter":"Copper(T)","value":"0.36","value_num":0.36,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart AU—Nickel Salts Production Subcategory","existing sources (PSES)","table: Subpart AU—Nickel Carbonate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.474 (PSES)","page":null,"quote":"Copper(T) 1.1 0.36"}},{"id":"48fad7daba8c14c1","parameter":"Copper","value":"0.00074","value_num":0.00074,"unit":"Kg/kkg (or pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart AU—Nickel Salts Production Subcategory","new sources (NSPS)","(a) Any new source subject to this subpart and producing nickel sulfate, nickel chloride, nickel fluorobate or nickel nitrate must achieve the following new source performance standards (NSPS):","table: Subpart AU—Nickel Sulfate, Nickel Chloride, Nickel Nitrate, and Nickel Fluoborate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.475 (NSPS)","page":null,"quote":"Copper 0.00074 0.00024"}},{"id":"0c87e8828d07eb20","parameter":"Copper","value":"0.00024","value_num":0.00024,"unit":"Kg/kkg (or pounds per 1,000 lb) of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart AU—Nickel Salts Production Subcategory","new sources (NSPS)","(a) Any new source subject to this subpart and producing nickel sulfate, nickel chloride, nickel fluorobate or nickel nitrate must achieve the following new source performance standards (NSPS):","table: Subpart AU—Nickel Sulfate, Nickel Chloride, Nickel Nitrate, and Nickel Fluoborate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.475 (NSPS)","page":null,"quote":"Copper 0.00074 0.00024"}},{"id":"821f9be2cfec2837","parameter":"Copper","value":"0.13","value_num":0.13,"unit":"Kg/kkg (or pounds per/1,000 lb) or product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart AU—Nickel Salts Production Subcategory","new sources (NSPS)","(b) Any new source subject to this subpart and producing nickel carbonate must achieve the following new source performance standards (NSPS):","table: Subpart AU—Nickel Carbonate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.475 (NSPS)","page":null,"quote":"Copper 0.13 0.042"}},{"id":"a247476a2658f5a5","parameter":"Copper","value":"0.042","value_num":0.042,"unit":"Kg/kkg (or pounds per/1,000 lb) or product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart AU—Nickel Salts Production Subcategory","new sources (NSPS)","(b) Any new source subject to this subpart and producing nickel carbonate must achieve the following new source performance standards (NSPS):","table: Subpart AU—Nickel Carbonate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.475 (NSPS)","page":null,"quote":"Copper 0.13 0.042"}},{"id":"69e651d1fe45947e","parameter":"Copper (T)","value":"3.3","value_num":3.3,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart BM—Cobalt Salts Production Subcategory","existing sources (PSES)","table: Subpart BM—Cobalt Salts"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.654 (PSES)","page":null,"quote":"Copper (T) 3.3 1.0"}},{"id":"11525fb2e5fe25c1","parameter":"Copper (T)","value":"1.0","value_num":1,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart BM—Cobalt Salts Production Subcategory","existing sources (PSES)","table: Subpart BM—Cobalt Salts"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.654 (PSES)","page":null,"quote":"Copper (T) 3.3 1.0"}},{"id":"b40a434e609b13bc","parameter":"Copper","value":"0.003","value_num":0.003,"unit":"kilograms per 1,000 kg of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","existing sources (BPT)","(d) The following limitations establish the quantity or quality of pollutants or pollutant properties which may be discharged by a point source subject to the provisions of this subpart and which processes residues by wet methods, after application of the best practical control technology currently available:","table: Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.32 (BPT)","page":null,"quote":"Copper 0.003"}},{"id":"965c28c0c5c82a37","parameter":"Copper","value":"0.0017","value_num":0.0017,"unit":"(Metric units, kg/kkg of product; English units, pounds per 1,000 lb of product)","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","existing sources (BPT)","table: Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.52 (BPT)","page":null,"quote":"Copper 0.0017 0.0008"}},{"id":"8b9b041d190ca69c","parameter":"Copper","value":"0.0008","value_num":0.0008,"unit":"(Metric units, kg/kkg of product; English units, pounds per 1,000 lb of product)","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","existing sources (BPT)","table: Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.52 (BPT)","page":null,"quote":"Copper 0.0017 0.0008"}},{"id":"f7fbc31806db944b","parameter":"Copper","value":".638","value_num":0.638,"unit":"mg/kg (pounds per million pounds) of copper cast","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","existing sources (BAT)","(a) Subpart E—Casting Contact Cooling.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.53 (BAT)","page":null,"quote":"Copper .638 .304"}},{"id":"7e7e5cac504576d2","parameter":"Copper","value":".304","value_num":0.304,"unit":"mg/kg (pounds per million pounds) of copper cast","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","existing sources (BAT)","(a) Subpart E—Casting Contact Cooling.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.53 (BAT)","page":null,"quote":"Copper .638 .304"}},{"id":"69fe96461fbd0ffa","parameter":"Copper","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of cathode copper production","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","existing sources (BAT)","(b) Subpart E—Anode and Cathode Rinse.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.53 (BAT)","page":null,"quote":"Copper .000 .000"}},{"id":"ceb8c668cd410853","parameter":"Copper","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of cathode copper production","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","existing sources (BAT)","(b) Subpart E—Anode and Cathode Rinse.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.53 (BAT)","page":null,"quote":"Copper .000 .000"}},{"id":"9b77eef6abed76c2","parameter":"Copper","value":".063","value_num":0.063,"unit":"mg/kg (pounds per million pounds) of copper cathode production","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","existing sources (BAT)","(c) Subpart E—Spent Electrolyte.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.53 (BAT)","page":null,"quote":"Copper .063 .030"}},{"id":"ed5efe0d9b2c762e","parameter":"Copper","value":".030","value_num":0.03,"unit":"mg/kg (pounds per million pounds) of copper cathode production","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","existing sources (BAT)","(c) Subpart E—Spent Electrolyte.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.53 (BAT)","page":null,"quote":"Copper .063 .030"}},{"id":"bd56464e0cd978b6","parameter":"Copper","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of casting production","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","existing sources (BAT)","(d) Subpart E—Casting Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.53 (BAT)","page":null,"quote":"Copper .000 .000"}},{"id":"29fd42dfe6169baa","parameter":"Copper","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of casting production","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","existing sources (BAT)","(d) Subpart E—Casting Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.53 (BAT)","page":null,"quote":"Copper .000 .000"}},{"id":"d75a0b328899aa1c","parameter":"Copper","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of product recovered from electrolytic slimes processing","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","existing sources (BAT)","(e) Subpart E—By-Product Recovery.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.53 (BAT)","page":null,"quote":"Copper .000 .000"}},{"id":"25dce57b81326bbc","parameter":"Copper","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of product recovered from electrolytic slimes processing","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","existing sources (BAT)","(e) Subpart E—By-Product Recovery.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.53 (BAT)","page":null,"quote":"Copper .000 .000"}},{"id":"6d4b48339b1b7160","parameter":"Copper","value":".638","value_num":0.638,"unit":"mg/kg (pounds per million pounds) of copper cast","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (NSPS)","(a) Subpart E—Casting Contact Cooling.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.54 (NSPS)","page":null,"quote":"Copper .638 .304"}},{"id":"f1e68305d2af794e","parameter":"Copper","value":".304","value_num":0.304,"unit":"mg/kg (pounds per million pounds) of copper cast","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (NSPS)","(a) Subpart E—Casting Contact Cooling.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.54 (NSPS)","page":null,"quote":"Copper .638 .304"}},{"id":"0cd771e12702bb4f","parameter":"Copper","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of cathode copper production","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (NSPS)","(b) Subpart E—Anode and Cathode Rinse.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.54 (NSPS)","page":null,"quote":"Copper .000 .000"}},{"id":"e66da70cfc291686","parameter":"Copper","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of cathode copper production","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (NSPS)","(b) Subpart E—Anode and Cathode Rinse.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.54 (NSPS)","page":null,"quote":"Copper .000 .000"}},{"id":"33c7a8aebf0f72ab","parameter":"Copper","value":".063","value_num":0.063,"unit":"mg/kg (pounds per million pounds) of copper cathode production","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (NSPS)","(c) Subpart E—Spent Electrolyte.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.54 (NSPS)","page":null,"quote":"Copper .063 .030"}},{"id":"4f5b5444c54fc624","parameter":"Copper","value":".030","value_num":0.03,"unit":"mg/kg (pounds per million pounds) of copper cathode production","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (NSPS)","(c) Subpart E—Spent Electrolyte.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.54 (NSPS)","page":null,"quote":"Copper .063 .030"}},{"id":"270c2f9c3ac4e6d6","parameter":"Copper","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of casting production","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (NSPS)","(d) Subpart E—Casting Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.54 (NSPS)","page":null,"quote":"Copper .000 .000"}},{"id":"5d4dd345e2c2884f","parameter":"Copper","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of casting production","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (NSPS)","(d) Subpart E—Casting Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.54 (NSPS)","page":null,"quote":"Copper .000 .000"}},{"id":"891a5ce26c16f901","parameter":"Copper","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of product recovered from electrolytic slimes processing","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (NSPS)","(e) Subpart E—By-Product Recovery.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.54 (NSPS)","page":null,"quote":"Copper .000 .000"}},{"id":"769fd07b317ed03f","parameter":"Copper","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of product recovered from electrolytic slimes processing","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (NSPS)","(e) Subpart E—By-Product Recovery.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.54 (NSPS)","page":null,"quote":"Copper .000 .000"}},{"id":"03dc599a5cbf6975","parameter":"Copper","value":".638","value_num":0.638,"unit":"mg/kg (pounds per million pounds) of copper cast","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (PSNS)","(a) Subpart E—Casting Contact Cooling.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.56 (PSNS)","page":null,"quote":"Copper .638 .304"}},{"id":"43f2eb7c30544fc5","parameter":"Copper","value":".304","value_num":0.304,"unit":"mg/kg (pounds per million pounds) of copper cast","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (PSNS)","(a) Subpart E—Casting Contact Cooling.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.56 (PSNS)","page":null,"quote":"Copper .638 .304"}},{"id":"92cd1e10d693b2ed","parameter":"Copper","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of cathode copper production","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (PSNS)","(b) Subpart E—Anode and Cathode Rinse.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.56 (PSNS)","page":null,"quote":"Copper .000 .000"}},{"id":"38de92402dc46466","parameter":"Copper","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of cathode copper production","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (PSNS)","(b) Subpart E—Anode and Cathode Rinse.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.56 (PSNS)","page":null,"quote":"Copper .000 .000"}},{"id":"1e82ebc25f62f32d","parameter":"Copper","value":".063","value_num":0.063,"unit":"mg/kg (pounds per million pounds) of cathode copper production","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (PSNS)","(c) Subpart E—Spent Electrolyte.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.56 (PSNS)","page":null,"quote":"Copper .063 .030"}},{"id":"bbcccaabc87358a6","parameter":"Copper","value":".030","value_num":0.03,"unit":"mg/kg (pounds per million pounds) of cathode copper production","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (PSNS)","(c) Subpart E—Spent Electrolyte.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.56 (PSNS)","page":null,"quote":"Copper .063 .030"}},{"id":"4bb571bd7b1751f6","parameter":"Copper","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of casting production","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (PSNS)","(d) Subpart E—Casting Wet Air Pollution Control.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.56 (PSNS)","page":null,"quote":"Copper .000 .000"}},{"id":"40e6f06a8c50a88e","parameter":"Copper","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of casting production","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (PSNS)","(d) Subpart E—Casting Wet Air Pollution Control.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.56 (PSNS)","page":null,"quote":"Copper .000 .000"}},{"id":"58aeab6a9f812719","parameter":"Copper","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of product recovered from electrolytic slimes processing","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (PSNS)","(e) Subpart E—By-Product Recovery.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.56 (PSNS)","page":null,"quote":"Copper .000 .000"}},{"id":"be629c8cf6973475","parameter":"Copper","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of product recovered from electrolytic slimes processing","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is sewer","cites is 40 CFR 421","the discharge is of the Subpart E—Primary Electrolytic Copper Refining Subcategory","new sources (PSNS)","(e) Subpart E—By-Product Recovery.","table: PSNS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.56 (PSNS)","page":null,"quote":"Copper .000 .000"}},{"id":"0bbaf270ddcddc8b","parameter":"Cu","value":"0.5","value_num":0.5,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart F—Secondary Copper Subcategory","existing sources (BPT)","(d) Any process wastewater discharged pursuant to paragraph (c) of this section shall comply with each of the following requirements:","column: Effluent characteristic"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.62 (BPT)","page":null,"quote":"Cu 0.5 0.25"}},{"id":"3524019916a5060d","parameter":"Cu","value":"0.25","value_num":0.25,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart F—Secondary Copper Subcategory","existing sources (BPT)","(d) Any process wastewater discharged pursuant to paragraph (c) of this section shall comply with each of the following requirements:","column: Effluent characteristic"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.62 (BPT)","page":null,"quote":"Cu 0.5 0.25"}},{"id":"c0e191d5f7baa617","parameter":"Copper","value":"2.135","value_num":2.135,"unit":"mg/kg (pounds per million pounds) of zinc reduced","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart H—Primary Zinc Subcategory","existing sources (BAT)","(a) Subpart H—Zinc Reduction Furnace Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.83 (BAT)","page":null,"quote":"Copper 2.135 1.018"}},{"id":"42ca6a0f8b9deab9","parameter":"Copper","value":"1.018","value_num":1.018,"unit":"mg/kg (pounds per million pounds) of zinc reduced","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart H—Primary Zinc Subcategory","existing sources (BAT)","(a) Subpart H—Zinc Reduction Furnace Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.83 (BAT)","page":null,"quote":"Copper 2.135 1.018"}},{"id":"aa7694f77ae5a468","parameter":"Copper","value":"1.153","value_num":1.153,"unit":"mg/kg (pounds per million pounds) of concentrate leached","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart H—Primary Zinc Subcategory","existing sources (BAT)","(b) Subpart H—Preleach of Zinc Concentrates.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.83 (BAT)","page":null,"quote":"Copper 1.153 .550"}},{"id":"4295d10fe7081c13","parameter":"Copper","value":".550","value_num":0.55,"unit":"mg/kg (pounds per million pounds) of concentrate leached","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart H—Primary Zinc Subcategory","existing sources (BAT)","(b) Subpart H—Preleach of Zinc Concentrates.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.83 (BAT)","page":null,"quote":"Copper 1.153 .550"}},{"id":"b48e863552d0e3f4","parameter":"Copper","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of zinc processed through leaching","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart H—Primary Zinc Subcategory","existing sources (BAT)","(c) Subpart H—Leaching Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.83 (BAT)","page":null,"quote":"Copper .000 .000"}},{"id":"209cd31e61ed892c","parameter":"Copper","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of zinc processed through leaching","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart H—Primary Zinc Subcategory","existing sources (BAT)","(c) Subpart H—Leaching Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.83 (BAT)","page":null,"quote":"Copper .000 .000"}},{"id":"68358db6c5ab661f","parameter":"Copper","value":".553","value_num":0.553,"unit":"mg/kg (pounds per million pounds) of cathode zinc produced","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart H—Primary Zinc Subcategory","existing sources (BAT)","(d) Subpart H—Electrolyte Bleed Wastewater.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.83 (BAT)","page":null,"quote":"Copper .553 .264"}},{"id":"4c088f9e827cc789","parameter":"Copper","value":".264","value_num":0.264,"unit":"mg/kg (pounds per million pounds) of cathode zinc produced","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart H—Primary Zinc Subcategory","existing sources (BAT)","(d) Subpart H—Electrolyte Bleed Wastewater.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.83 (BAT)","page":null,"quote":"Copper .553 .264"}},{"id":"735569983a742e21","parameter":"Copper","value":".961","value_num":0.961,"unit":"mg/kg (pounds per million pounds) of cathode zinc produced","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart H—Primary Zinc Subcategory","existing sources (BAT)","(e) Subpart H—Cathode and Anode Wash Wastewater.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.83 (BAT)","page":null,"quote":"Copper .961 .458"}},{"id":"a9e737837693a559","parameter":"Copper","value":".458","value_num":0.458,"unit":"mg/kg (pounds per million pounds) of cathode zinc produced","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart H—Primary Zinc Subcategory","existing sources (BAT)","(e) Subpart H—Cathode and Anode Wash Wastewater.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.83 (BAT)","page":null,"quote":"Copper .961 .458"}},{"id":"76d174a442b9123c","parameter":"Copper","value":".329","value_num":0.329,"unit":"mg/kg (pounds per million pounds) of zinc cast","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart H—Primary Zinc Subcategory","existing sources (BAT)","(f) Subpart H—Casting Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.83 (BAT)","page":null,"quote":"Copper .329 .157"}},{"id":"4134b5ed92f44cca","parameter":"Copper","value":".157","value_num":0.157,"unit":"mg/kg (pounds per million pounds) of zinc cast","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart H—Primary Zinc Subcategory","existing sources (BAT)","(f) Subpart H—Casting Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.83 (BAT)","page":null,"quote":"Copper .329 .157"}},{"id":"3ca74e3124b481df","parameter":"Copper","value":".232","value_num":0.232,"unit":"mg/kg (pounds per million pounds) of zinc cast","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart H—Primary Zinc Subcategory","existing sources (BAT)","(g) Subpart H—Casting Contact Cooling.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.83 (BAT)","page":null,"quote":"Copper .232 .110"}},{"id":"1f2556a02e55a34a","parameter":"Copper","value":".110","value_num":0.11,"unit":"mg/kg (pounds per million pounds) of zinc cast","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart H—Primary Zinc Subcategory","existing sources (BAT)","(g) Subpart H—Casting Contact Cooling.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.83 (BAT)","page":null,"quote":"Copper .232 .110"}},{"id":"85db47175ac8e324","parameter":"Copper","value":"7.899","value_num":7.899,"unit":"mg/kg (pounds per million pounds) of cadmium produced","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart H—Primary Zinc Subcategory","existing sources (BAT)","(h) Subpart H—Cadmium Plant Wastewater.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.83 (BAT)","page":null,"quote":"Copper 7.899 3.765"}},{"id":"1632ddc561cb2d5a","parameter":"Copper","value":"3.765","value_num":3.765,"unit":"mg/kg (pounds per million pounds) of cadmium produced","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart H—Primary Zinc Subcategory","existing sources (BAT)","(h) Subpart H—Cadmium Plant Wastewater.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.83 (BAT)","page":null,"quote":"Copper 7.899 3.765"}},{"id":"64c2a4cf3b65e437","parameter":"Copper","value":"2.135","value_num":2.135,"unit":"mg/kg (pounds per million pounds) of zinc reduced","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart H—Primary Zinc Subcategory","new sources (NSPS)","(a) Subpart H—Zinc Reduction Furnace Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.84 (NSPS)","page":null,"quote":"Copper 2.135 1.018"}},{"id":"108aa2c91919fdd0","parameter":"Copper","value":"1.018","value_num":1.018,"unit":"mg/kg (pounds per million pounds) of zinc reduced","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart H—Primary Zinc Subcategory","new sources (NSPS)","(a) Subpart H—Zinc Reduction Furnace Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.84 (NSPS)","page":null,"quote":"Copper 2.135 1.018"}},{"id":"42ddfa2671d631a5","parameter":"Copper","value":"1.153","value_num":1.153,"unit":"mg/kg (pounds per million pounds) of concentrate leached","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart H—Primary Zinc Subcategory","new sources (NSPS)","(b) Subpart H—Preleach of Zinc Concentrates.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.84 (NSPS)","page":null,"quote":"Copper 1.153 .550"}},{"id":"a0bd065c1faeb677","parameter":"Copper","value":".550","value_num":0.55,"unit":"mg/kg (pounds per million pounds) of concentrate leached","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart H—Primary Zinc Subcategory","new sources (NSPS)","(b) Subpart H—Preleach of Zinc Concentrates.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.84 (NSPS)","page":null,"quote":"Copper 1.153 .550"}},{"id":"449e6eeb47b4abea","parameter":"Copper","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of zinc processed through leaching","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart H—Primary Zinc Subcategory","new sources (NSPS)","(c) Subpart H—Leaching Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.84 (NSPS)","page":null,"quote":"Copper .000 .000"}},{"id":"0d4421e5bd6d95c4","parameter":"Copper","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of zinc processed through leaching","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart H—Primary Zinc Subcategory","new sources (NSPS)","(c) Subpart H—Leaching Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.84 (NSPS)","page":null,"quote":"Copper .000 .000"}},{"id":"e3277615b37a1e18","parameter":"Copper","value":".553","value_num":0.553,"unit":"mg/kg (pounds per million pounds) of cathode zinc produced","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart H—Primary Zinc Subcategory","new sources (NSPS)","(d) Subpart H—Electrolyte Bleed Wastewater.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.84 (NSPS)","page":null,"quote":"Copper .553 .264"}},{"id":"f946dcef8ccee21e","parameter":"Copper","value":".264","value_num":0.264,"unit":"mg/kg (pounds per million pounds) of cathode zinc produced","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart H—Primary Zinc Subcategory","new sources (NSPS)","(d) Subpart H—Electrolyte Bleed Wastewater.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.84 (NSPS)","page":null,"quote":"Copper .553 .264"}},{"id":"bf90eadf2fb693e8","parameter":"Copper","value":".961","value_num":0.961,"unit":"mg/kg (pounds per million pounds) of cathode zinc produced","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart H—Primary Zinc Subcategory","new sources (NSPS)","(e) Subpart H—Cathode and Anode Wash Wastewater.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.84 (NSPS)","page":null,"quote":"Copper .961 .458"}},{"id":"4b9aa9d22a8dde38","parameter":"Copper","value":".458","value_num":0.458,"unit":"mg/kg (pounds per million pounds) of cathode zinc produced","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart H—Primary Zinc Subcategory","new sources (NSPS)","(e) Subpart H—Cathode and Anode Wash Wastewater.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.84 (NSPS)","page":null,"quote":"Copper .961 .458"}},{"id":"fd36bed90af496b5","parameter":"Copper","value":".329","value_num":0.329,"unit":"mg/kg (pounds per million pounds) of zinc cast","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7440-50-8","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart H—Primary Zinc Subcategory","new sources (NSPS)","(f) Subpart H—Casting Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.84 (NSPS)","page":null,"quote":"Copper .329 .157"}}],"next":[{"tool":"list_permits","says":"Who in this state went over on it? list_permits lists the state's permits whose last 12 months went over a limit on it, each with its record and its get_permit address; `get` is the address to fetch.","arguments":{"state":"MN","parameter":"copper total"},"needs":{},"get":"https://passage-data.com/api/v1/permits?state=MN&parameter=copper+total","url":"https://passage-data.com/api/v1/permits?state=MN&parameter=copper+total"},{"tool":"check_values","says":"Has your user measured this? check_values sets each of their results beside every row held here, with a verdict and the row's cite.","arguments":{"place":"US-MN"},"needs":{"rows":"Your user's measured results, as their table prints them: [{parameter: \"copper total\", value, unit}, ...], any other parameters too."},"post":"/api/v1/check","url":"https://passage-data.com/api/v1/check","page":"https://passage-data.com/limits/US-MN/copper-total#check"},{"tool":"read_certificate","says":"Has your user a laboratory certificate? read_certificate reads every row it prints, each with its page, and checks them against these limits.","arguments":{"place":"US-MN"},"needs":{"content_base64":"The laboratory's certificate (PDF) or its XLSX, XLS or CSV export, as base64; or file_url, a public https address of it."},"post":"/api/v1/certificate","url":"https://passage-data.com/api/v1/certificate","page":"https://passage-data.com/limits/US-MN/copper-total#check"}]}