{"query":{"parameter":"chromium vi","place":"US-FL","medium":null,"statistic":null,"kind":null},"searched":{"places":["US-FL","US"],"parameter_keys":["cas:18540-29-9","name:chromium (vi) (freshwater) chromium (vi) marine","cas:7440-47-3","name:chromium (+6)","name:chromium +6","name:chromium +6, total"],"names_matched":[["chromium vi","cas:18540-29-9"],["chromium vi freshwater chromium vi marine","name:chromium (vi) (freshwater) chromium (vi) marine"],["chromium 6","cas:7440-47-3","chromium 6"],["chromium 6","name:chromium (+6)","chromium 6"],["chromium 6","name:chromium +6","chromium 6"],["chromium 6 total","name:chromium +6, total","chromium 6"],["chromium 6 total recoverable","name:chromium (+6)","chromium 6"]],"match":"exact+contains","order":"The place's own instruments first, then each place above it, each in its register's order","not_sent":{"rows":2532,"names":["Chromium","Chromium (total)","Total chromium","Total Chromium","Chromium (Total)","Chromium (T)","Cr","Chromium, total"],"says":"2532 rows share a parameter key with a longer name holding \"chromium vi\" but are printed under names without these words (that key is wider than the name), or keyed to a CAS number \"chromium vi\" does not name (another substance, whatever words its name holds): not sent. Ask for one by its name or CAS number."}},"total":159,"offset":0,"returned":159,"next_offset":null,"rows":[{"id":"e01cae6924185e8a","parameter":"Chromium (hexavalent)","value":"11","value_num":11,"unit":"µg/L","direction":"max","kind":"threshold","medium":"surface_water","level":"regional","parameter_key":"cas:18540-29-9","place":["US-FL"],"conditions":["receiving_water is freshwater","freshwater surface water (Table I, Freshwater Surface Water Criteria column)","Note: If more than one contaminant is present at a site, CTLs are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Figure 10 of the February 2005 'Final Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.' However, GCTLs for primary and secondary standards shall not be modified."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"changed","changed_on":"2026-10-16","says":"Source changed on or before 2026-10-16, not yet re-read: these rows are as read from Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'."},"section":"Ch. 62-777 F.A.C. Table I, Groundwater and Surface Water Cleanup Target Levels, Freshwater Surface Water Criteria (DEP spreadsheet, sheet TTable1, row 134)","page":null,"quote":"row 134: Chromium (hexavalent) |  | 11 | 50 |  | -Respiratory  | 18540-29-9 | -yes  |  | 62-302 | 62-302 |  |  | g | g"}},{"id":"1316824b2ddba9de","parameter":"Chromium (hexavalent)","value":"50","value_num":50,"unit":"µg/L","direction":"max","kind":"threshold","medium":"surface_water","level":"regional","parameter_key":"cas:18540-29-9","place":["US-FL"],"conditions":["receiving_water is marine","marine surface water (Table I, Marine Surface Water Criteria column)","Note: If more than one contaminant is present at a site, CTLs are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Figure 10 of the February 2005 'Final Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.' However, GCTLs for primary and secondary standards shall not be modified."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"changed","changed_on":"2026-10-16","says":"Source changed on or before 2026-10-16, not yet re-read: these rows are as read from Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'."},"section":"Ch. 62-777 F.A.C. Table I, Groundwater and Surface Water Cleanup Target Levels, Marine Surface Water Criteria (DEP spreadsheet, sheet TTable1, row 134)","page":null,"quote":"row 134: Chromium (hexavalent) |  | 11 | 50 |  | -Respiratory  | 18540-29-9 | -yes  |  | 62-302 | 62-302 |  |  | g | g"}},{"id":"a44296daab45584f","parameter":"Chromium (hexavalent)","value":"210","value_num":210,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:18540-29-9","place":["US-FL"],"conditions":["residential direct exposure (Table II, Direct Exposure - Residential column)","Note: If more than one contaminant is present at a site, the direct exposure values are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Appendix D 'Draft Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.', dated February 2005."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"changed","changed_on":"2026-10-16","says":"Source changed on or before 2026-10-16, not yet re-read: these rows are as read from Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'."},"section":"Ch. 62-777 F.A.C. Table II, Soil Cleanup Target Levels, Direct Exposure - Residential (DEP spreadsheet, sheet TTable2, row 125)","page":null,"quote":"row 125: Chromium (hexavalent) | -Respiratory  | 18540-29-9 | 210 | 470 | NA | 4.2 | 19 | NA | -yes  | (b)"}},{"id":"48c603ef89dd289d","parameter":"Chromium (hexavalent)","value":"470","value_num":470,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:18540-29-9","place":["US-FL"],"conditions":["industrial direct exposure (Table II, Direct Exposure - Industrial column)","Note: If more than one contaminant is present at a site, the direct exposure values are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Appendix D 'Draft Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.', dated February 2005."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"changed","changed_on":"2026-10-16","says":"Source changed on or before 2026-10-16, not yet re-read: these rows are as read from Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'."},"section":"Ch. 62-777 F.A.C. Table II, Soil Cleanup Target Levels, Direct Exposure - Industrial (DEP spreadsheet, sheet TTable2, row 125)","page":null,"quote":"row 125: Chromium (hexavalent) | -Respiratory  | 18540-29-9 | 210 | 470 | NA | 4.2 | 19 | NA | -yes  | (b)"}},{"id":"bda49ed44b5670fd","parameter":"Chromium (hexavalent)","value":"4.2","value_num":4.2,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:18540-29-9","place":["US-FL"],"conditions":["leachability based on freshwater surface water criteria (Table II, Leachability Based on Freshwater SW column)","Note: If more than one contaminant is present at a site, the direct exposure values are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Appendix D 'Draft Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.', dated February 2005."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"changed","changed_on":"2026-10-16","says":"Source changed on or before 2026-10-16, not yet re-read: these rows are as read from Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'."},"section":"Ch. 62-777 F.A.C. Table II, Soil Cleanup Target Levels, Leachability Based on Freshwater SW (DEP spreadsheet, sheet TTable2, row 125)","page":null,"quote":"row 125: Chromium (hexavalent) | -Respiratory  | 18540-29-9 | 210 | 470 | NA | 4.2 | 19 | NA | -yes  | (b)"}},{"id":"1cddcb64414b2392","parameter":"Chromium (hexavalent)","value":"19","value_num":19,"unit":"mg/kg","direction":"max","kind":"threshold","medium":"soil","level":"regional","parameter_key":"cas:18540-29-9","place":["US-FL"],"conditions":["leachability based on marine surface water criteria (Table II, Leachability Based on Marine SW column)","Note: If more than one contaminant is present at a site, the direct exposure values are to be modified, if necessary, such that the sum of the hazard quotients for non-carcinogenic contaminants affecting the same organ(s) is 1 or less. For carcinogens, the direct exposure values shall be modified such that the cumulative lifetime risk level posed by the contaminants is 1.0E-06, as presented in Appendix D 'Draft Technical Report: Development of Cleanup Target Levels (CTLs) for Chapter 62-777, F.A.C.', dated February 2005."],"cite":{"instrument":"us_fl_62_777","title":"Chapter 62-777, F.A.C. (Florida): cleanup target levels — Table I Groundwater and Surface Water, Table II Soil","issuer":"State of Florida, Department of Environmental Protection (Division of Waste Management)","edition":"Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'","source_url":"https://floridadep.gov/sites/default/files/62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005%20.xlsx","source_sha256":"d4eff83970269c22f672f6723b5d139b992eccbb64afc372622abb56f23d91c9","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"changed","changed_on":"2026-10-16","says":"Source changed on or before 2026-10-16, not yet re-read: these rows are as read from Chapter 62-777, F.A.C., Tables I and II as the Department of Environmental Protection posts them as spreadsheets: Table I '62-777-TechRprt-Table1-Groundwater-CTLs_Feb2005 .xlsx' and Table II '62-777TechReportApril2005Table2SoilCTLs-CAS_24Oct13_0.xlsx' (server Last-Modified 2025-10-30 for both), fetched 2026-10-15; DEP's petroleum excerpt of the same tables (held) dates them 'effective April 17, 2005'."},"section":"Ch. 62-777 F.A.C. Table II, Soil Cleanup Target Levels, Leachability Based on Marine SW (DEP spreadsheet, sheet TTable2, row 125)","page":null,"quote":"row 125: Chromium (hexavalent) | -Respiratory  | 18540-29-9 | 210 | 470 | NA | 4.2 | 19 | NA | -yes  | (b)"}},{"id":"a2cb40265d8c4315","parameter":"Chromium (hexavalent)","value":"< 11","value_num":11,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:18540-29-9","place":["US-FL"],"conditions":["receiving_water is freshwater","Class I, potable water supplies (waters listed by name in 62-302.400, F.A.C.)"],"cite":{"instrument":"us_fl_wqs","title":"F.A.C. 62-302.530 Table: Surface Water Quality Criteria (Florida) — Class I, II, III fresh, III marine and IV criteria","issuer":"State of Florida, Department of Environmental Protection (Environmental Regulation Commission)","edition":"Chapter 62-302, F.A.C., as US EPA posts it in effect for Clean Water Act purposes; 62-302.530 amended through 11-25-25 (its history note, p. 45); EPA's re-posting of 2026-10-05 (PDF CreationDate), fetched 2026-10-15","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/fl_section62-302.pdf","source_sha256":"9865f1a6486a9332278c619fbcd71dc9f4f19af10e39576eea8ae900136aa284","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"F.A.C. 62-302.530(b)","page":33,"quote":null}},{"id":"de16312510f88bb3","parameter":"Chromium (hexavalent)","value":"< 50","value_num":50,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:18540-29-9","place":["US-FL"],"conditions":["receiving_water is marine","Class II, shellfish propagation or harvesting (waters listed by name in 62-302.400, F.A.C.)"],"cite":{"instrument":"us_fl_wqs","title":"F.A.C. 62-302.530 Table: Surface Water Quality Criteria (Florida) — Class I, II, III fresh, III marine and IV criteria","issuer":"State of Florida, Department of Environmental Protection (Environmental Regulation Commission)","edition":"Chapter 62-302, F.A.C., as US EPA posts it in effect for Clean Water Act purposes; 62-302.530 amended through 11-25-25 (its history note, p. 45); EPA's re-posting of 2026-10-05 (PDF CreationDate), fetched 2026-10-15","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/fl_section62-302.pdf","source_sha256":"9865f1a6486a9332278c619fbcd71dc9f4f19af10e39576eea8ae900136aa284","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"F.A.C. 62-302.530(b)","page":33,"quote":null}},{"id":"5f7073385bd9d04d","parameter":"Chromium (hexavalent)","value":"< 11","value_num":11,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:18540-29-9","place":["US-FL"],"conditions":["receiving_water is freshwater","Class III and Class III-Limited, predominantly fresh waters (every Florida surface water not listed in 62-302.400, F.A.C., is Class III)"],"cite":{"instrument":"us_fl_wqs","title":"F.A.C. 62-302.530 Table: Surface Water Quality Criteria (Florida) — Class I, II, III fresh, III marine and IV criteria","issuer":"State of Florida, Department of Environmental Protection (Environmental Regulation Commission)","edition":"Chapter 62-302, F.A.C., as US EPA posts it in effect for Clean Water Act purposes; 62-302.530 amended through 11-25-25 (its history note, p. 45); EPA's re-posting of 2026-10-05 (PDF CreationDate), fetched 2026-10-15","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/fl_section62-302.pdf","source_sha256":"9865f1a6486a9332278c619fbcd71dc9f4f19af10e39576eea8ae900136aa284","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"F.A.C. 62-302.530(b)","page":33,"quote":null}},{"id":"73111e29d01109e4","parameter":"Chromium (hexavalent)","value":"< 50","value_num":50,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:18540-29-9","place":["US-FL"],"conditions":["receiving_water is marine","Class III and Class III-Limited, predominantly marine waters (every Florida surface water not listed in 62-302.400, F.A.C., is Class III)"],"cite":{"instrument":"us_fl_wqs","title":"F.A.C. 62-302.530 Table: Surface Water Quality Criteria (Florida) — Class I, II, III fresh, III marine and IV criteria","issuer":"State of Florida, Department of Environmental Protection (Environmental Regulation Commission)","edition":"Chapter 62-302, F.A.C., as US EPA posts it in effect for Clean Water Act purposes; 62-302.530 amended through 11-25-25 (its history note, p. 45); EPA's re-posting of 2026-10-05 (PDF CreationDate), fetched 2026-10-15","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/fl_section62-302.pdf","source_sha256":"9865f1a6486a9332278c619fbcd71dc9f4f19af10e39576eea8ae900136aa284","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"F.A.C. 62-302.530(b)","page":33,"quote":null}},{"id":"5610bda4f2076798","parameter":"Chromium (hexavalent)","value":"< 11","value_num":11,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"regional","parameter_key":"cas:18540-29-9","place":["US-FL"],"conditions":["receiving_water is freshwater","Class IV, agricultural water supplies (waters listed by name in 62-302.400, F.A.C.)"],"cite":{"instrument":"us_fl_wqs","title":"F.A.C. 62-302.530 Table: Surface Water Quality Criteria (Florida) — Class I, II, III fresh, III marine and IV criteria","issuer":"State of Florida, Department of Environmental Protection (Environmental Regulation Commission)","edition":"Chapter 62-302, F.A.C., as US EPA posts it in effect for Clean Water Act purposes; 62-302.530 amended through 11-25-25 (its history note, p. 45); EPA's re-posting of 2026-10-05 (PDF CreationDate), fetched 2026-10-15","source_url":"https://www.epa.gov/sites/default/files/2014-12/documents/fl_section62-302.pdf","source_sha256":"9865f1a6486a9332278c619fbcd71dc9f4f19af10e39576eea8ae900136aa284","fetched_at":"2026-10-15","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"F.A.C. 62-302.530(b)","page":33,"quote":null}},{"id":"586a491f98bacb89","parameter":"Hexavalent chromium","value":"0.25","value_num":0.25,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart L—Potassium Dichromate Production Subcategory","existing sources (PSES)","table: Subpart L—Potassium Dichromate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.124 (PSES)","page":null,"quote":"Hexavalent chromium 0.25 0.090"}},{"id":"80c65545de24faef","parameter":"Hexavalent chromium","value":"0.090","value_num":0.09,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart L—Potassium Dichromate Production Subcategory","existing sources (PSES)","table: Subpart L—Potassium Dichromate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.124 (PSES)","page":null,"quote":"Hexavalent chromium 0.25 0.090"}},{"id":"44301cb82638239a","parameter":"Hexavalent Chromium","value":"0.00090","value_num":0.0009,"unit":"Kg/kkg (or pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart Q—Sodium Dichromate and Sodium Sulfate Production Subcategory","existing sources (BPT)","table: Subpart Q—Sodium Dichromate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.172 (BPT)","page":null,"quote":"Hexavalent Chromium 0.00090 0.00050"}},{"id":"e684d0fc30e3fb2e","parameter":"Hexavalent Chromium","value":"0.00050","value_num":0.0005,"unit":"Kg/kkg (or pounds per 1,000 lb) of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 415","the discharge is of the Subpart Q—Sodium Dichromate and Sodium Sulfate Production Subcategory","existing sources (BPT)","table: Subpart Q—Sodium Dichromate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.172 (BPT)","page":null,"quote":"Hexavalent Chromium 0.00090 0.00050"}},{"id":"e4dade62badb7d43","parameter":"Hexavalent Chromium","value":"0.11","value_num":0.11,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart Q—Sodium Dichromate and Sodium Sulfate Production Subcategory","new sources (PSNS)","table: Subpart Q—Sodium Dichromate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.176 (PSNS)","page":null,"quote":"Hexavalent Chromium 0.11 0.060"}},{"id":"3db527f50ed7c0c9","parameter":"Hexavalent Chromium","value":"0.060","value_num":0.06,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart Q—Sodium Dichromate and Sodium Sulfate Production Subcategory","new sources (PSNS)","table: Subpart Q—Sodium Dichromate"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.176 (PSNS)","page":null,"quote":"Hexavalent Chromium 0.11 0.060"}},{"id":"ac5fe4fc7e451cb8","parameter":"Hexavalent Chromium","value":"0.25","value_num":0.25,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart AL—Ferric Chloride Production Subcategory","existing sources (PSES)","table: Subpart AL—Ferric Chloride"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.384 (PSES)","page":null,"quote":"Hexavalent Chromium 0.25 0.09"}},{"id":"bbc4a35bef16796d","parameter":"Hexavalent Chromium","value":"0.09","value_num":0.09,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 415","the discharge is of the Subpart AL—Ferric Chloride Production Subcategory","existing sources (PSES)","table: Subpart AL—Ferric Chloride"],"cite":{"instrument":"us_40cfr415","title":"40 CFR Part 415 — PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-08-01","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-01/title-40.xml?part=415","source_sha256":"ebf67428a51e85f12785b92d537e6878c5f9838c87722ac2db82b3db673d1e23","fetched_at":"2026-09-24","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 415.384 (PSES)","page":null,"quote":"Hexavalent Chromium 0.25 0.09"}},{"id":"8e0092fd8ade30fc","parameter":"Hexavalent chromium","value":"0.028","value_num":0.028,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.12 (BPT)","page":null,"quote":"Hexavalent chromium 0.028 0.012"}},{"id":"5675ce4c2773c41c","parameter":"Hexavalent chromium","value":"0.012","value_num":0.012,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.12 (BPT)","page":null,"quote":"Hexavalent chromium 0.028 0.012"}},{"id":"a5c170365a595d95","parameter":"Hexavalent chromium","value":"0.062","value_num":0.062,"unit":"kilograms per 1,000 m³ of flow","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BPT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by th…"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.12 (BPT)","page":null,"quote":"Hexavalent chromium 0.062 0.028"}},{"id":"57a3d27a2709f0fb","parameter":"Hexavalent chromium","value":"0.028","value_num":0.028,"unit":"kilograms per 1,000 m³ of flow","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BPT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by th…"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.12 (BPT)","page":null,"quote":"Hexavalent chromium 0.062 0.028"}},{"id":"f7aa6927893b9926","parameter":"Hexavalent chromium","value":"0.0019","value_num":0.0019,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Crude"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Crude 0.0019 0.0009"}},{"id":"a0641b29156d1dcf","parameter":"Hexavalent chromium","value":"0.0009","value_num":0.0009,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Crude"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Crude 0.0019 0.0009"}},{"id":"cb746acdf3ee94fc","parameter":"Hexavalent chromium","value":"0.0218","value_num":0.0218,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Cracking and coking"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Cracking and coking 0.0218 0.0098"}},{"id":"1ddda5fac1059bee","parameter":"Hexavalent chromium","value":"0.0098","value_num":0.0098,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Cracking and coking"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Cracking and coking 0.0218 0.0098"}},{"id":"6861827fb0da18f1","parameter":"Hexavalent chromium","value":"0.0117","value_num":0.0117,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Asphalt"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Asphalt 0.0117 0.0053"}},{"id":"f831dc28ef48615f","parameter":"Hexavalent chromium","value":"0.0053","value_num":0.0053,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Asphalt"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Asphalt 0.0117 0.0053"}},{"id":"52d8f1f5a9e229bf","parameter":"Hexavalent chromium","value":"0.0549","value_num":0.0549,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Lube"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Lube 0.0549 0.0248"}},{"id":"b05e64665a23de5a","parameter":"Hexavalent chromium","value":"0.0248","value_num":0.0248,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Lube"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Lube 0.0549 0.0248"}},{"id":"0019d027dc08b268","parameter":"Hexavalent chromium","value":"0.0196","value_num":0.0196,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Reforming and alkylation"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Reforming and alkylation 0.0196 0.0088"}},{"id":"68fa7b81afc4c94c","parameter":"Hexavalent chromium","value":"0.0088","value_num":0.0088,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Reforming and alkylation"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Reforming and alkylation 0.0196 0.0088"}},{"id":"3a1f5e0f74cba875","parameter":"Hexavalent chromium","value":"0.062","value_num":0.062,"unit":"kilograms per 1,000 m³ of flow","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the permit writer times the …"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Hexavalent chromium 0.062 0.028"}},{"id":"16cc83d20ea9fd1e","parameter":"Hexavalent chromium","value":"0.028","value_num":0.028,"unit":"kilograms per 1,000 m³ of flow","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","existing sources (BAT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the permit writer times the …"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.13 (BAT)","page":null,"quote":"Hexavalent chromium 0.062 0.028"}},{"id":"f8ce2214c9c13e87","parameter":"Hexavalent chromium","value":"0.015","value_num":0.015,"unit":"kilograms per cubic meter of flow","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","new sources (NSPS)","(a) Any new source subject to this subpart must achieve the following new source performance standards (NSPS):"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.16 (NSPS)","page":null,"quote":"Hexavalent chromium 0.015 0.0068"}},{"id":"fe6afefbdfe84ab5","parameter":"Hexavalent chromium","value":"0.0068","value_num":0.0068,"unit":"kilograms per cubic meter of flow","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart A—Topping Subcategory","new sources (NSPS)","(a) Any new source subject to this subpart must achieve the following new source performance standards (NSPS):"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.16 (NSPS)","page":null,"quote":"Hexavalent chromium 0.015 0.0068"}},{"id":"93f79981d38f7f8d","parameter":"Hexavalent chromium","value":"0.035","value_num":0.035,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.22 (BPT)","page":null,"quote":"Hexavalent chromium 0.035 0.016"}},{"id":"fecd421c87b4153a","parameter":"Hexavalent chromium","value":"0.016","value_num":0.016,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.22 (BPT)","page":null,"quote":"Hexavalent chromium 0.035 0.016"}},{"id":"ad4ccebfba672c86","parameter":"Hexavalent chromium","value":"0.062","value_num":0.062,"unit":"kilograms per 1,000 m³ of flow","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BPT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by th…"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.22 (BPT)","page":null,"quote":"Hexavalent chromium 0.062 0.028"}},{"id":"39eb6f7004a4d0da","parameter":"Hexavalent chromium","value":"0.028","value_num":0.028,"unit":"kilograms per 1,000 m³ of flow","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BPT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by th…"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.22 (BPT)","page":null,"quote":"Hexavalent chromium 0.062 0.028"}},{"id":"897bc7314a3e2fe1","parameter":"Hexavalent chromium","value":"0.0019","value_num":0.0019,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Crude"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.23 (BAT)","page":null,"quote":"Crude 0.0019 0.0009"}},{"id":"694830b8e0e244bc","parameter":"Hexavalent chromium","value":"0.0009","value_num":0.0009,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Crude"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.23 (BAT)","page":null,"quote":"Crude 0.0019 0.0009"}},{"id":"1e0569faa1c26e89","parameter":"Hexavalent chromium","value":"0.0218","value_num":0.0218,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Cracking and coking"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.23 (BAT)","page":null,"quote":"Cracking and coking 0.0218 0.0098"}},{"id":"7ae4474e993c1e76","parameter":"Hexavalent chromium","value":"0.0098","value_num":0.0098,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Cracking and coking"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.23 (BAT)","page":null,"quote":"Cracking and coking 0.0218 0.0098"}},{"id":"2413ddaf09abdc6e","parameter":"Hexavalent chromium","value":"0.0117","value_num":0.0117,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Asphalt"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.23 (BAT)","page":null,"quote":"Asphalt 0.0117 0.0053"}},{"id":"a2b9d06774470e48","parameter":"Hexavalent chromium","value":"0.0053","value_num":0.0053,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Asphalt"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.23 (BAT)","page":null,"quote":"Asphalt 0.0117 0.0053"}},{"id":"9589e823087d3b55","parameter":"Hexavalent chromium","value":"0.0549","value_num":0.0549,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Lube"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.23 (BAT)","page":null,"quote":"Lube 0.0549 0.0248"}},{"id":"c62579684af504e1","parameter":"Hexavalent chromium","value":"0.0248","value_num":0.0248,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Lube"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.23 (BAT)","page":null,"quote":"Lube 0.0549 0.0248"}},{"id":"4c88effa896d66e0","parameter":"Hexavalent chromium","value":"0.0196","value_num":0.0196,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Reforming and alkylation"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.23 (BAT)","page":null,"quote":"Reforming and alkylation 0.0196 0.0088"}},{"id":"37ef6dba2f9fc4c9","parameter":"Hexavalent chromium","value":"0.0088","value_num":0.0088,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Reforming and alkylation"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.23 (BAT)","page":null,"quote":"Reforming and alkylation 0.0196 0.0088"}},{"id":"8b6cc9cb3b195338","parameter":"Hexavalent chromium","value":"0.062","value_num":0.062,"unit":"kilograms per 1,000 m³ of flow","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BAT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the permit writer times the …"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.23 (BAT)","page":null,"quote":"Hexavalent chromium 0.062 0.028"}},{"id":"eeec884b37d0a408","parameter":"Hexavalent chromium","value":"0.028","value_num":0.028,"unit":"kilograms per 1,000 m³ of flow","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","existing sources (BAT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the permit writer times the …"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.23 (BAT)","page":null,"quote":"Hexavalent chromium 0.062 0.028"}},{"id":"2bdef93e4fa98984","parameter":"Hexavalent chromium","value":"0.020","value_num":0.02,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","new sources (NSPS)","(a) Any new source subject to this subpart must achieve the following new source performance standards (NSPS):"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.26 (NSPS)","page":null,"quote":"Hexavalent chromium 0.020 0.0088"}},{"id":"881275d31272d0f7","parameter":"Hexavalent chromium","value":"0.0088","value_num":0.0088,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart B—Cracking Subcategory","new sources (NSPS)","(a) Any new source subject to this subpart must achieve the following new source performance standards (NSPS):"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.26 (NSPS)","page":null,"quote":"Hexavalent chromium 0.020 0.0088"}},{"id":"927f186024de7f19","parameter":"Hexavalent chromium","value":"0.046","value_num":0.046,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart C—Petrochemical Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.32 (BPT)","page":null,"quote":"Hexavalent chromium 0.046 0.020"}},{"id":"47ba8ebf0df03275","parameter":"Hexavalent chromium","value":"0.020","value_num":0.02,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart C—Petrochemical Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.32 (BPT)","page":null,"quote":"Hexavalent chromium 0.046 0.020"}},{"id":"dfa5d80cae844db0","parameter":"Hexavalent chromium","value":"0.062","value_num":0.062,"unit":"kilograms per 1,000 m³ of flow","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart C—Petrochemical Subcategory","existing sources (BPT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by th…"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.32 (BPT)","page":null,"quote":"Hexavalent chromium 0.062 0.028"}},{"id":"1152662361715388","parameter":"Hexavalent chromium","value":"0.028","value_num":0.028,"unit":"kilograms per 1,000 m³ of flow","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart C—Petrochemical Subcategory","existing sources (BPT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by th…"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.32 (BPT)","page":null,"quote":"Hexavalent chromium 0.062 0.028"}},{"id":"21362fe607c7f03f","parameter":"Hexavalent chromium","value":"0.0019","value_num":0.0019,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart C—Petrochemical Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Crude"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.33 (BAT)","page":null,"quote":"Crude 0.0019 0.0009"}},{"id":"aee33e114e88b6fe","parameter":"Hexavalent chromium","value":"0.0009","value_num":0.0009,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart C—Petrochemical Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Crude"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.33 (BAT)","page":null,"quote":"Crude 0.0019 0.0009"}},{"id":"a140171835eb9bc6","parameter":"Hexavalent chromium","value":"0.0218","value_num":0.0218,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart C—Petrochemical Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Cracking and coking"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.33 (BAT)","page":null,"quote":"Cracking and coking 0.0218 0.0098"}},{"id":"43c8fbff86baaa1a","parameter":"Hexavalent chromium","value":"0.0098","value_num":0.0098,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart C—Petrochemical Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Cracking and coking"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.33 (BAT)","page":null,"quote":"Cracking and coking 0.0218 0.0098"}},{"id":"337a3bf64205db79","parameter":"Hexavalent chromium","value":"0.0117","value_num":0.0117,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart C—Petrochemical Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Asphalt"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.33 (BAT)","page":null,"quote":"Asphalt 0.0117 0.0053"}},{"id":"81a539e0df9b4583","parameter":"Hexavalent chromium","value":"0.0053","value_num":0.0053,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart C—Petrochemical Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Asphalt"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.33 (BAT)","page":null,"quote":"Asphalt 0.0117 0.0053"}},{"id":"9878002fee9a03c1","parameter":"Hexavalent chromium","value":"0.0549","value_num":0.0549,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart C—Petrochemical Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Lube"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.33 (BAT)","page":null,"quote":"Lube 0.0549 0.0248"}},{"id":"f034f251ef22daf5","parameter":"Hexavalent chromium","value":"0.0248","value_num":0.0248,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart C—Petrochemical Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Lube"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.33 (BAT)","page":null,"quote":"Lube 0.0549 0.0248"}},{"id":"d6f0568e6f467ac2","parameter":"Hexavalent chromium","value":"0.0196","value_num":0.0196,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart C—Petrochemical Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Reforming and alkylation"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.33 (BAT)","page":null,"quote":"Reforming and alkylation 0.0196 0.0088"}},{"id":"d69401290b4d3724","parameter":"Hexavalent chromium","value":"0.0088","value_num":0.0088,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart C—Petrochemical Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Reforming and alkylation"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.33 (BAT)","page":null,"quote":"Reforming and alkylation 0.0196 0.0088"}},{"id":"c7650a15f1e26f92","parameter":"Hexavalent chromium","value":"0.062","value_num":0.062,"unit":"kilograms per 1,000 m³ of flow","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart C—Petrochemical Subcategory","existing sources (BAT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the permit writer times the …"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.33 (BAT)","page":null,"quote":"Hexavalent chromium 0.062 0.028"}},{"id":"67234b51572e5b2d","parameter":"Hexavalent chromium","value":"0.028","value_num":0.028,"unit":"kilograms per 1,000 m³ of flow","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart C—Petrochemical Subcategory","existing sources (BAT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the permit writer times the …"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.33 (BAT)","page":null,"quote":"Hexavalent chromium 0.062 0.028"}},{"id":"a0e52701c2c5da83","parameter":"Hexavalent chromium","value":"0.025","value_num":0.025,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart C—Petrochemical Subcategory","new sources (NSPS)","(a) Any new source subject to this subpart must achieve the following new source performance standards (NSPS):"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.36 (NSPS)","page":null,"quote":"Hexavalent chromium 0.025 0.012"}},{"id":"e3825559376654da","parameter":"Hexavalent chromium","value":"0.012","value_num":0.012,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart C—Petrochemical Subcategory","new sources (NSPS)","(a) Any new source subject to this subpart must achieve the following new source performance standards (NSPS):"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.36 (NSPS)","page":null,"quote":"Hexavalent chromium 0.025 0.012"}},{"id":"4f65adb251b8388b","parameter":"Hexavalent chromium","value":"0.068","value_num":0.068,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart D—Lube Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.42 (BPT)","page":null,"quote":"Hexavalent chromium 0.068 0.030"}},{"id":"12db38c87e26a123","parameter":"Hexavalent chromium","value":"0.030","value_num":0.03,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart D—Lube Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.42 (BPT)","page":null,"quote":"Hexavalent chromium 0.068 0.030"}},{"id":"1b44d4cd211a7534","parameter":"Hexavalent chromium","value":"0.062","value_num":0.062,"unit":"kilograms per 1,000 m³ of flow","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart D—Lube Subcategory","existing sources (BPT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by th…"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.42 (BPT)","page":null,"quote":"Hexavalent chromium 0.062 0.028"}},{"id":"19ad1057ca4aa288","parameter":"Hexavalent chromium","value":"0.028","value_num":0.028,"unit":"kilograms per 1,000 m³ of flow","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart D—Lube Subcategory","existing sources (BPT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by th…"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.42 (BPT)","page":null,"quote":"Hexavalent chromium 0.062 0.028"}},{"id":"e393a3019d0be867","parameter":"Hexavalent chromium","value":"0.0019","value_num":0.0019,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart D—Lube Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Crude"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.43 (BAT)","page":null,"quote":"Crude 0.0019 0.0009"}},{"id":"4ba12680744079db","parameter":"Hexavalent chromium","value":"0.0009","value_num":0.0009,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart D—Lube Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Crude"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.43 (BAT)","page":null,"quote":"Crude 0.0019 0.0009"}},{"id":"f54828772aca25f9","parameter":"Hexavalent chromium","value":"0.0218","value_num":0.0218,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart D—Lube Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Cracking and coking"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.43 (BAT)","page":null,"quote":"Cracking and coking 0.0218 0.0098"}},{"id":"110f5632062586a0","parameter":"Hexavalent chromium","value":"0.0098","value_num":0.0098,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart D—Lube Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Cracking and coking"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.43 (BAT)","page":null,"quote":"Cracking and coking 0.0218 0.0098"}},{"id":"846c250135cfdecb","parameter":"Hexavalent chromium","value":"0.0117","value_num":0.0117,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart D—Lube Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Asphalt"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.43 (BAT)","page":null,"quote":"Asphalt 0.0117 0.0053"}},{"id":"9195ececdde1e715","parameter":"Hexavalent chromium","value":"0.0053","value_num":0.0053,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart D—Lube Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Asphalt"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.43 (BAT)","page":null,"quote":"Asphalt 0.0117 0.0053"}},{"id":"706c0b57c67b2e25","parameter":"Hexavalent chromium","value":"0.0549","value_num":0.0549,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart D—Lube Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Lube"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.43 (BAT)","page":null,"quote":"Lube 0.0549 0.0248"}},{"id":"1618b1352cbb502b","parameter":"Hexavalent chromium","value":"0.0248","value_num":0.0248,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart D—Lube Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Lube"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.43 (BAT)","page":null,"quote":"Lube 0.0549 0.0248"}},{"id":"beb36c7caaaa9b0d","parameter":"Hexavalent chromium","value":"0.0196","value_num":0.0196,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart D—Lube Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Reforming and alkylation"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.43 (BAT)","page":null,"quote":"Reforming and alkylation 0.0196 0.0088"}},{"id":"1ce4eba76c8aeac0","parameter":"Hexavalent chromium","value":"0.0088","value_num":0.0088,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart D—Lube Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Reforming and alkylation"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.43 (BAT)","page":null,"quote":"Reforming and alkylation 0.0196 0.0088"}},{"id":"1461a49673909202","parameter":"Hexavalent chromium","value":"0.062","value_num":0.062,"unit":"kilograms per 1,000 m³ of flow","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart D—Lube Subcategory","existing sources (BAT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the permit writer times the …"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.43 (BAT)","page":null,"quote":"Hexavalent chromium 0.062 0.028"}},{"id":"4915491da1d6fbc8","parameter":"Hexavalent chromium","value":"0.028","value_num":0.028,"unit":"kilograms per 1,000 m³ of flow","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart D—Lube Subcategory","existing sources (BAT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the permit writer times the …"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.43 (BAT)","page":null,"quote":"Hexavalent chromium 0.062 0.028"}},{"id":"08f82cd25b6db98f","parameter":"Hexavalent chromium","value":"0.046","value_num":0.046,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart D—Lube Subcategory","new sources (NSPS)","(a) Any new source subject to this subpart must achieve the following new source performance standards (NSPS):"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.46 (NSPS)","page":null,"quote":"Hexavalent chromium 0.046 0.021"}},{"id":"c2d06776859db9ab","parameter":"Hexavalent chromium","value":"0.021","value_num":0.021,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart D—Lube Subcategory","new sources (NSPS)","(a) Any new source subject to this subpart must achieve the following new source performance standards (NSPS):"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.46 (NSPS)","page":null,"quote":"Hexavalent chromium 0.046 0.021"}},{"id":"1fc336f3827eb3f0","parameter":"Hexavalent chromium","value":"0.068","value_num":0.068,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart E—Integrated Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.52 (BPT)","page":null,"quote":"Hexavalent chromium 0.068 0.032"}},{"id":"ed5c88fd670df3c2","parameter":"Hexavalent chromium","value":"0.032","value_num":0.032,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart E—Integrated Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.52 (BPT)","page":null,"quote":"Hexavalent chromium 0.068 0.032"}},{"id":"d738a384a937d3ef","parameter":"Hexavalent chromium","value":"0.062","value_num":0.062,"unit":"kilograms per 1,000 m³ of flow","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart E—Integrated Subcategory","existing sources (BPT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by th…"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.52 (BPT)","page":null,"quote":"Hexavalent chromium 0.062 0.028"}},{"id":"9125506085ffaa0d","parameter":"Hexavalent chromium","value":"0.028","value_num":0.028,"unit":"kilograms per 1,000 m³ of flow","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart E—Integrated Subcategory","existing sources (BPT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 15 mg/l oil and grease or 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by th…"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.52 (BPT)","page":null,"quote":"Hexavalent chromium 0.062 0.028"}},{"id":"2f7716d6ffb1077d","parameter":"Hexavalent chromium","value":"0.0019","value_num":0.0019,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart E—Integrated Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Crude"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.53 (BAT)","page":null,"quote":"Crude 0.0019 0.0009"}},{"id":"6d5cc4556f629e2f","parameter":"Hexavalent chromium","value":"0.0009","value_num":0.0009,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart E—Integrated Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Crude"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.53 (BAT)","page":null,"quote":"Crude 0.0019 0.0009"}},{"id":"f01c3f24136e7d6b","parameter":"Hexavalent chromium","value":"0.0218","value_num":0.0218,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart E—Integrated Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Cracking and coking"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.53 (BAT)","page":null,"quote":"Cracking and coking 0.0218 0.0098"}},{"id":"a9b8c1ac817da898","parameter":"Hexavalent chromium","value":"0.0098","value_num":0.0098,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart E—Integrated Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Cracking and coking"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.53 (BAT)","page":null,"quote":"Cracking and coking 0.0218 0.0098"}},{"id":"f58bfb03656706c1","parameter":"Hexavalent chromium","value":"0.0117","value_num":0.0117,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart E—Integrated Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Asphalt"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.53 (BAT)","page":null,"quote":"Asphalt 0.0117 0.0053"}},{"id":"b791d80532781358","parameter":"Hexavalent chromium","value":"0.0053","value_num":0.0053,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart E—Integrated Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Asphalt"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.53 (BAT)","page":null,"quote":"Asphalt 0.0117 0.0053"}},{"id":"026ae7168af0eea6","parameter":"Hexavalent chromium","value":"0.0549","value_num":0.0549,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart E—Integrated Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Lube"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.53 (BAT)","page":null,"quote":"Lube 0.0549 0.0248"}},{"id":"184475235f8e89b1","parameter":"Hexavalent chromium","value":"0.0248","value_num":0.0248,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart E—Integrated Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Lube"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.53 (BAT)","page":null,"quote":"Lube 0.0549 0.0248"}},{"id":"eb6cbfcbf060a390","parameter":"Hexavalent chromium","value":"0.0196","value_num":0.0196,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart E—Integrated Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Reforming and alkylation"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.53 (BAT)","page":null,"quote":"Reforming and alkylation 0.0196 0.0088"}},{"id":"e8c6574431880792","parameter":"Hexavalent chromium","value":"0.0088","value_num":0.0088,"unit":"kilograms per 1,000 cubic meters of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart E—Integrated Subcategory","existing sources (BAT)","(i) For each of the regulated pollutant parameters listed below, the effluent limitation for a given refinery is the sum of the products of each effluent limitation factor times the applicable process feedstock rate, calculated as provided in 40 CFR 122.45(b). Applicable production processes are presented in appendix A, by process type. The process identification numbers presented in this appen…","table row: Reforming and alkylation"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.53 (BAT)","page":null,"quote":"Reforming and alkylation 0.0196 0.0088"}},{"id":"5dead6200e591da3","parameter":"Hexavalent chromium","value":"0.062","value_num":0.062,"unit":"kilograms per 1,000 m³ of flow","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart E—Integrated Subcategory","existing sources (BAT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the permit writer times the …"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.53 (BAT)","page":null,"quote":"Hexavalent chromium 0.062 0.028"}},{"id":"2b719c6478cd89ff","parameter":"Hexavalent chromium","value":"0.028","value_num":0.028,"unit":"kilograms per 1,000 m³ of flow","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart E—Integrated Subcategory","existing sources (BAT)","(2) If contaminated runoff is commingled or treated with process wastewater, or if wastewater consisting solely of contaminated runoff which exceeds 110 mg/l TOC is not commingled or treated with any other type of wastewater, the quantity of pollutants discharged shall not exceed the quantity determined by multiplying the flow of contaminated runoff as determined by the permit writer times the …"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.53 (BAT)","page":null,"quote":"Hexavalent chromium 0.062 0.028"}},{"id":"6ac18078ef11ba0b","parameter":"Hexavalent chromium","value":"0.052","value_num":0.052,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart E—Integrated Subcategory","new sources (NSPS)","(a) Any new source subject to this subpart must achieve the following new source performance standards (NSPS):"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.56 (NSPS)","page":null,"quote":"Hexavalent chromium 0.052 0.024"}},{"id":"de3368ee70433c2b","parameter":"Hexavalent chromium","value":"0.024","value_num":0.024,"unit":"kilograms per 1,000 m³ of feedstock","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 419","the discharge is of the Subpart E—Integrated Subcategory","new sources (NSPS)","(a) Any new source subject to this subpart must achieve the following new source performance standards (NSPS):"],"cite":{"instrument":"us_40cfr419","title":"40 CFR Part 419 — PART 419—PETROLEUM REFINING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=419","source_sha256":"3bac23cae59f82ac6f96310d28b2d8904c650932053de79f037f6d4f6d3db849","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 419.56 (NSPS)","page":null,"quote":"Hexavalent chromium 0.052 0.024"}},{"id":"c87283b81adfd50d","parameter":"Chromium (hexavalent)","value":"0.000150","value_num":0.00015,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 420","the discharge is of the Subpart L—Hot Coating Subcategory","existing sources (BPT)","(a) Galvanizing, terne coating, and other coatings —(1) Strip, sheet, and miscellaneous products.","table: Subpart L"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 420.122 (BPT)","page":null,"quote":"Chromium (hexavalent) 1 0.000150 0.0000501"}},{"id":"c1ee22c7cd80f9b5","parameter":"Chromium (hexavalent)","value":"0.0000501","value_num":0.0000501,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 420","the discharge is of the Subpart L—Hot Coating Subcategory","existing sources (BPT)","(a) Galvanizing, terne coating, and other coatings —(1) Strip, sheet, and miscellaneous products.","table: Subpart L"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 420.122 (BPT)","page":null,"quote":"Chromium (hexavalent) 1 0.000150 0.0000501"}},{"id":"18dcd47f0c7cf730","parameter":"Chromium (hexavalent)","value":"0.000600","value_num":0.0006,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 420","the discharge is of the Subpart L—Hot Coating Subcategory","existing sources (BPT)","(b) Galvanizing and other coatings —(1) Wire products and fasteners.","table: Subpart L"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 420.122 (BPT)","page":null,"quote":"Chromium (hexavalent) 1 0.000600 0.000200"}},{"id":"40e9c507e07a5743","parameter":"Chromium (hexavalent)","value":"0.000200","value_num":0.0002,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 420","the discharge is of the Subpart L—Hot Coating Subcategory","existing sources (BPT)","(b) Galvanizing and other coatings —(1) Wire products and fasteners.","table: Subpart L"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 420.122 (BPT)","page":null,"quote":"Chromium (hexavalent) 1 0.000600 0.000200"}},{"id":"c754af3a735ef149","parameter":"Chromium (hexavalent)","value":"0.0327","value_num":0.0327,"statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 420","the discharge is of the Subpart L—Hot Coating Subcategory","existing sources (BPT)","(c) Fume scrubbers.","table: Subpart L","table heading: Kg per day"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 420.122 (BPT)","page":null,"quote":"Chromium (hexavalent) 1 0.0327 0.0109"}},{"id":"abce51b4f567a537","parameter":"Chromium (hexavalent)","value":"0.0109","value_num":0.0109,"statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 420","the discharge is of the Subpart L—Hot Coating Subcategory","existing sources (BPT)","(c) Fume scrubbers.","table: Subpart L","table heading: Kg per day"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 420.122 (BPT)","page":null,"quote":"Chromium (hexavalent) 1 0.0327 0.0109"}},{"id":"5b2ef205f7bbb06f","parameter":"Chromium (hexavalent)","value":"0.000150","value_num":0.00015,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 420","the discharge is of the Subpart L—Hot Coating Subcategory","existing sources (BAT)","(a) Galvanizing, terne coating and other coatings —(1) Strip, sheet, and miscellaneous products scrubbers.","table: Subpart L"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 420.123 (BAT)","page":null,"quote":"Chromium (hexavalent) 1 0.000150 0.0000501"}},{"id":"1575d1441934a332","parameter":"Chromium (hexavalent)","value":"0.0000501","value_num":0.0000501,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 420","the discharge is of the Subpart L—Hot Coating Subcategory","existing sources (BAT)","(a) Galvanizing, terne coating and other coatings —(1) Strip, sheet, and miscellaneous products scrubbers.","table: Subpart L"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 420.123 (BAT)","page":null,"quote":"Chromium (hexavalent) 1 0.000150 0.0000501"}},{"id":"c058e16f002b1ea0","parameter":"Chromium (hexavalent)","value":"0.000601","value_num":0.000601,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 420","the discharge is of the Subpart L—Hot Coating Subcategory","existing sources (BAT)","(b) Galvanizing and other coatings —(1) Wire products and fasteners.","table: Subpart L"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 420.123 (BAT)","page":null,"quote":"Chromium (hexavalent) 1 0.000601 0.000200"}},{"id":"0a7a16d38cf059b9","parameter":"Chromium (hexavalent)","value":"0.000200","value_num":0.0002,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 420","the discharge is of the Subpart L—Hot Coating Subcategory","existing sources (BAT)","(b) Galvanizing and other coatings —(1) Wire products and fasteners.","table: Subpart L"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 420.123 (BAT)","page":null,"quote":"Chromium (hexavalent) 1 0.000601 0.000200"}},{"id":"132d35cbe2bca4d7","parameter":"Chromium (hexavalent)","value":"0.00490","value_num":0.0049,"statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 420","the discharge is of the Subpart L—Hot Coating Subcategory","existing sources (BAT)","(c) Fume scrubbers.","table: Subpart L","table heading: Kg per day"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 420.123 (BAT)","page":null,"quote":"Chromium (hexavalent) 1 0.00490 0.00163"}},{"id":"20ea0bd751f8db29","parameter":"Chromium (hexavalent)","value":"0.00163","value_num":0.00163,"statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 420","the discharge is of the Subpart L—Hot Coating Subcategory","existing sources (BAT)","(c) Fume scrubbers.","table: Subpart L","table heading: Kg per day"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 420.123 (BAT)","page":null,"quote":"Chromium (hexavalent) 1 0.00490 0.00163"}},{"id":"c5054de52a3369d5","parameter":"Chromium (hexavalent)","value":"0.0000376","value_num":0.0000376,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 420","the discharge is of the Subpart L—Hot Coating Subcategory","new sources (NSPS)","(a) Galvanizing, terne coating and other coatings —(1) Strip, sheet, and miscellaneous products.","table: Subpart L"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 420.124 (NSPS)","page":null,"quote":"Chromium (hexavalent) 1 0.0000376 0.0000125"}},{"id":"a46079ca42eb9bed","parameter":"Chromium (hexavalent)","value":"0.0000125","value_num":0.0000125,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 420","the discharge is of the Subpart L—Hot Coating Subcategory","new sources (NSPS)","(a) Galvanizing, terne coating and other coatings —(1) Strip, sheet, and miscellaneous products.","table: Subpart L"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 420.124 (NSPS)","page":null,"quote":"Chromium (hexavalent) 1 0.0000376 0.0000125"}},{"id":"6a403f56d9c49846","parameter":"Chromium (hexavalent)","value":"0.000150","value_num":0.00015,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 420","the discharge is of the Subpart L—Hot Coating Subcategory","new sources (NSPS)","(b) Galvanizing and other coatings —(1) Wire products and fasteners.","table: Subpart L"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 420.124 (NSPS)","page":null,"quote":"Chromium (hexavalent) 1 0.000150 0.0000501"}},{"id":"24d6014a9204bc07","parameter":"Chromium (hexavalent)","value":"0.0000501","value_num":0.0000501,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 420","the discharge is of the Subpart L—Hot Coating Subcategory","new sources (NSPS)","(b) Galvanizing and other coatings —(1) Wire products and fasteners.","table: Subpart L"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 420.124 (NSPS)","page":null,"quote":"Chromium (hexavalent) 1 0.000150 0.0000501"}},{"id":"116b3734ed039c78","parameter":"Chromium (hexavalent)","value":"0.00490","value_num":0.0049,"unit":"kg/per day","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 420","the discharge is of the Subpart L—Hot Coating Subcategory","new sources (NSPS)","(c) Fume scrubbers.","table: Subpart L","column: Pollutant or pollutant property"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 420.124 (NSPS)","page":null,"quote":"Chromium (hexavalent) 1 0.00490 0.00163"}},{"id":"d5a600a9f7ad830a","parameter":"Chromium (hexavalent)","value":"0.00163","value_num":0.00163,"unit":"kg/per day","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 420","the discharge is of the Subpart L—Hot Coating Subcategory","new sources (NSPS)","(c) Fume scrubbers.","table: Subpart L","column: Pollutant or pollutant property"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 420.124 (NSPS)","page":null,"quote":"Chromium (hexavalent) 1 0.00490 0.00163"}},{"id":"e848198930bcf0dd","parameter":"Chromium (hexavalent)","value":"0.000150","value_num":0.00015,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 420","the discharge is of the Subpart L—Hot Coating Subcategory","existing sources (PSES)","(a) Galvanizing, terne coating and other coatings —(1) Strip, sheet, and miscellaneous products.","table: Subpart L","column: Pollutant or pollutant property"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 420.125 (PSES)","page":null,"quote":"Chromium (hexavalent) 1 0.000150 0.0000501"}},{"id":"882d6546e5426e55","parameter":"Chromium (hexavalent)","value":"0.0000501","value_num":0.0000501,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 420","the discharge is of the Subpart L—Hot Coating Subcategory","existing sources (PSES)","(a) Galvanizing, terne coating and other coatings —(1) Strip, sheet, and miscellaneous products.","table: Subpart L","column: Pollutant or pollutant property"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 420.125 (PSES)","page":null,"quote":"Chromium (hexavalent) 1 0.000150 0.0000501"}},{"id":"8ccded4a058ae039","parameter":"Chromium (hexavalent)","value":"0.000601","value_num":0.000601,"unit":"kg/kkg (pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 420","the discharge is of the Subpart L—Hot Coating Subcategory","existing sources (PSES)","(b) Galvanizing and other coatings —(1) Wire products and fasteners.","table: Subpart L"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 420.125 (PSES)","page":null,"quote":"Chromium (hexavalent) 1 0.000601 0.000200"}},{"id":"d7ce475a06abbca6","parameter":"Chromium (hexavalent)","value":"0.000200","value_num":0.0002,"unit":"kg/kkg (pounds per 1,000 lb) of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 420","the discharge is of the Subpart L—Hot Coating Subcategory","existing sources (PSES)","(b) Galvanizing and other coatings —(1) Wire products and fasteners.","table: Subpart L"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 420.125 (PSES)","page":null,"quote":"Chromium (hexavalent) 1 0.000601 0.000200"}},{"id":"2a7e3801b95880b1","parameter":"Chromium (hexavalent)","value":"0.00490","value_num":0.0049,"statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 420","the discharge is of the Subpart L—Hot Coating Subcategory","existing sources (PSES)","(c) Fume scrubbers.","table: Subpart L","table heading: Kg per day"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 420.125 (PSES)","page":null,"quote":"Chromium (hexavalent) 1 0.00490 0.00163"}},{"id":"04bb2624a8e15b08","parameter":"Chromium (hexavalent)","value":"0.00163","value_num":0.00163,"statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 420","the discharge is of the Subpart L—Hot Coating Subcategory","existing sources (PSES)","(c) Fume scrubbers.","table: Subpart L","table heading: Kg per day"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 420.125 (PSES)","page":null,"quote":"Chromium (hexavalent) 1 0.00490 0.00163"}},{"id":"c7f65d6ee8378ad4","parameter":"Chromium (hexavalent)","value":"0.0000376","value_num":0.0000376,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 420","the discharge is of the Subpart L—Hot Coating Subcategory","new sources (PSNS)","(a) Galvanizing, terne coatings and other coatings —(1) Strip, sheet, and miscellaneous products.","table: Subpart L"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 420.126 (PSNS)","page":null,"quote":"Chromium (hexavalent) 1 0.0000376 0.0000125"}},{"id":"43b4913681d39df5","parameter":"Chromium (hexavalent)","value":"0.0000125","value_num":0.0000125,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 420","the discharge is of the Subpart L—Hot Coating Subcategory","new sources (PSNS)","(a) Galvanizing, terne coatings and other coatings —(1) Strip, sheet, and miscellaneous products.","table: Subpart L"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 420.126 (PSNS)","page":null,"quote":"Chromium (hexavalent) 1 0.0000376 0.0000125"}},{"id":"c9b10eb894baeec9","parameter":"Chromium (hexavalent)","value":"0.000150","value_num":0.00015,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 420","the discharge is of the Subpart L—Hot Coating Subcategory","new sources (PSNS)","(b) Galvanizing and other coatings —(1) Wire products and fasteners.","table: Subpart L"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 420.126 (PSNS)","page":null,"quote":"Chromium (hexavalent) 1 0.000150 0.0000501"}},{"id":"658bc05946e786a7","parameter":"Chromium (hexavalent)","value":"0.0000501","value_num":0.0000501,"unit":"Kg/kkg (pounds per 1,000 lb) of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 420","the discharge is of the Subpart L—Hot Coating Subcategory","new sources (PSNS)","(b) Galvanizing and other coatings —(1) Wire products and fasteners.","table: Subpart L"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 420.126 (PSNS)","page":null,"quote":"Chromium (hexavalent) 1 0.000150 0.0000501"}},{"id":"634d902cff38e975","parameter":"Chromium (Hexavalent)","value":"0.00490","value_num":0.0049,"unit":"Kilograms per day","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 420","the discharge is of the Subpart L—Hot Coating Subcategory","new sources (PSNS)","(c) Fume scrubbers.","table: Subpart L"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 420.126 (PSNS)","page":null,"quote":"Chromium (Hexavalent) 1 0.00490 0.00163"}},{"id":"81502bfce4998f9e","parameter":"Chromium (Hexavalent)","value":"0.00163","value_num":0.00163,"unit":"Kilograms per day","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"sewer","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is sewer","cites is 40 CFR 420","the discharge is of the Subpart L—Hot Coating Subcategory","new sources (PSNS)","(c) Fume scrubbers.","table: Subpart L"],"cite":{"instrument":"us_40cfr420","title":"40 CFR Part 420 — PART 420—IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=420","source_sha256":"15d00b2386811ecfdcc8334d57defe2f690d2f88798390abff59228c5aea1898","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 420.126 (PSNS)","page":null,"quote":"Chromium (Hexavalent) 1 0.00490 0.00163"}},{"id":"c1d5838a0475be34","parameter":"Chromium VI","value":".0006","value_num":0.0006,"unit":"kg/Mwh","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 424","the discharge is of the Subpart A—Open Electric Furnaces With Wet Air Pollution Control Devices Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr424","title":"40 CFR Part 424 — PART 424—FERROALLOY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=424","source_sha256":"b9ba02c4f274d6907407c320e0fcce140e72aa79cf2e81ae80ae804f723e7bed","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 424.12 (BPT)","page":null,"quote":"Chromium VI .0006 .0003"}},{"id":"d70feed9bc33c89c","parameter":"Chromium VI","value":".0003","value_num":0.0003,"unit":"kg/Mwh","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 424","the discharge is of the Subpart A—Open Electric Furnaces With Wet Air Pollution Control Devices Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr424","title":"40 CFR Part 424 — PART 424—FERROALLOY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=424","source_sha256":"b9ba02c4f274d6907407c320e0fcce140e72aa79cf2e81ae80ae804f723e7bed","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 424.12 (BPT)","page":null,"quote":"Chromium VI .0006 .0003"}},{"id":"90599b2f28e9ec44","parameter":"Chromium VI","value":".00008","value_num":0.00008,"unit":"kg/Mwh","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 424","the discharge is of the Subpart A—Open Electric Furnaces With Wet Air Pollution Control Devices Subcategory","existing sources (BAT)","The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable:"],"cite":{"instrument":"us_40cfr424","title":"40 CFR Part 424 — PART 424—FERROALLOY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=424","source_sha256":"b9ba02c4f274d6907407c320e0fcce140e72aa79cf2e81ae80ae804f723e7bed","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 424.13 (BAT)","page":null,"quote":"Chromium VI .00008 .00004"}},{"id":"a9667491ef60fcf9","parameter":"Chromium VI","value":".00004","value_num":0.00004,"unit":"kg/Mwh","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 424","the discharge is of the Subpart A—Open Electric Furnaces With Wet Air Pollution Control Devices Subcategory","existing sources (BAT)","The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable:"],"cite":{"instrument":"us_40cfr424","title":"40 CFR Part 424 — PART 424—FERROALLOY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=424","source_sha256":"b9ba02c4f274d6907407c320e0fcce140e72aa79cf2e81ae80ae804f723e7bed","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 424.13 (BAT)","page":null,"quote":"Chromium VI .00008 .00004"}},{"id":"4e0284cf210acaff","parameter":"Chromium VI","value":".00008","value_num":0.00008,"unit":"kg/Mwh","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 424","the discharge is of the Subpart A—Open Electric Furnaces With Wet Air Pollution Control Devices Subcategory","new sources (NSPS)","The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:"],"cite":{"instrument":"us_40cfr424","title":"40 CFR Part 424 — PART 424—FERROALLOY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=424","source_sha256":"b9ba02c4f274d6907407c320e0fcce140e72aa79cf2e81ae80ae804f723e7bed","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 424.15 (NSPS)","page":null,"quote":"Chromium VI .00008 .00004"}},{"id":"fc0a20e7b83e0976","parameter":"Chromium VI","value":".00004","value_num":0.00004,"unit":"kg/Mwh","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 424","the discharge is of the Subpart A—Open Electric Furnaces With Wet Air Pollution Control Devices Subcategory","new sources (NSPS)","The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:"],"cite":{"instrument":"us_40cfr424","title":"40 CFR Part 424 — PART 424—FERROALLOY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=424","source_sha256":"b9ba02c4f274d6907407c320e0fcce140e72aa79cf2e81ae80ae804f723e7bed","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 424.15 (NSPS)","page":null,"quote":"Chromium VI .00008 .00004"}},{"id":"9fd92e32e31350f5","parameter":"Chromium VI","value":".0008","value_num":0.0008,"unit":"kg/Mwh","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 424","the discharge is of the Subpart B—Covered Electric Furnaces and Other Smelting Operations With Wet Air Pollution Control Devices Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr424","title":"40 CFR Part 424 — PART 424—FERROALLOY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=424","source_sha256":"b9ba02c4f274d6907407c320e0fcce140e72aa79cf2e81ae80ae804f723e7bed","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 424.22 (BPT)","page":null,"quote":"Chromium VI .0008 .0004"}},{"id":"60d460d7ec8b192e","parameter":"Chromium VI","value":".0004","value_num":0.0004,"unit":"kg/Mwh","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 424","the discharge is of the Subpart B—Covered Electric Furnaces and Other Smelting Operations With Wet Air Pollution Control Devices Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr424","title":"40 CFR Part 424 — PART 424—FERROALLOY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=424","source_sha256":"b9ba02c4f274d6907407c320e0fcce140e72aa79cf2e81ae80ae804f723e7bed","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 424.22 (BPT)","page":null,"quote":"Chromium VI .0008 .0004"}},{"id":"356ed6879eddb6d8","parameter":"Chromium VI","value":".0001","value_num":0.0001,"unit":"kg/Mwh","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 424","the discharge is of the Subpart B—Covered Electric Furnaces and Other Smelting Operations With Wet Air Pollution Control Devices Subcategory","existing sources (BAT)","The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable:"],"cite":{"instrument":"us_40cfr424","title":"40 CFR Part 424 — PART 424—FERROALLOY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=424","source_sha256":"b9ba02c4f274d6907407c320e0fcce140e72aa79cf2e81ae80ae804f723e7bed","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 424.23 (BAT)","page":null,"quote":"Chromium VI .0001 .00005"}},{"id":"367d06b3ced4525c","parameter":"Chromium VI","value":".00005","value_num":0.00005,"unit":"kg/Mwh","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 424","the discharge is of the Subpart B—Covered Electric Furnaces and Other Smelting Operations With Wet Air Pollution Control Devices Subcategory","existing sources (BAT)","The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable:"],"cite":{"instrument":"us_40cfr424","title":"40 CFR Part 424 — PART 424—FERROALLOY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=424","source_sha256":"b9ba02c4f274d6907407c320e0fcce140e72aa79cf2e81ae80ae804f723e7bed","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 424.23 (BAT)","page":null,"quote":"Chromium VI .0001 .00005"}},{"id":"1ae634b5289082a0","parameter":"Chromium VI","value":".0001","value_num":0.0001,"unit":"kg/Mwh","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 424","the discharge is of the Subpart B—Covered Electric Furnaces and Other Smelting Operations With Wet Air Pollution Control Devices Subcategory","new sources (NSPS)","The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:"],"cite":{"instrument":"us_40cfr424","title":"40 CFR Part 424 — PART 424—FERROALLOY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=424","source_sha256":"b9ba02c4f274d6907407c320e0fcce140e72aa79cf2e81ae80ae804f723e7bed","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 424.25 (NSPS)","page":null,"quote":"Chromium VI .0001 .00005"}},{"id":"53df55ebab44a0bc","parameter":"Chromium VI","value":".00005","value_num":0.00005,"unit":"kg/Mwh","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["route is direct","cites is 40 CFR 424","the discharge is of the Subpart B—Covered Electric Furnaces and Other Smelting Operations With Wet Air Pollution Control Devices Subcategory","new sources (NSPS)","The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:"],"cite":{"instrument":"us_40cfr424","title":"40 CFR Part 424 — PART 424—FERROALLOY MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=424","source_sha256":"b9ba02c4f274d6907407c320e0fcce140e72aa79cf2e81ae80ae804f723e7bed","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 424.25 (NSPS)","page":null,"quote":"Chromium VI .0001 .00005"}},{"id":"3162e2769a03e5b1","parameter":"Chromium (VI)","value":"16","value_num":16,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"national","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["EPA's recommendation under Clean Water Act § 304(a): 'State and Tribal governments may use these criteria or use them as guidance in developing their own' — it binds a water once the state adopts it for the water's designated use","receiving_water is freshwater","Freshwater CMC (acute): criterion maximum concentration, acute"],"cite":{"instrument":"us_nrwqc_aquatic","title":"EPA National Recommended Water Quality Criteria — Aquatic Life Criteria Table (freshwater and saltwater CMC/CCC)","issuer":"U.S. Environmental Protection Agency","edition":"EPA web table, last updated on June 9, 2026 (fetched 2026-10-09); each criterion carries its publication year","source_url":"https://www.epa.gov/wqc/national-recommended-water-quality-criteria-aquatic-life-criteria-table","source_sha256":"be6b429558db9852c3456eb22c17046aa1a3335ee89e702e8afb793f9b5b25ec","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"not verified"},"section":"National Recommended Aquatic Life Criteria table","page":null,"quote":"Chromium (VI) (P) 18540299 16 11 1,100 50 1995"}},{"id":"b29d8e47250c282b","parameter":"Chromium (VI)","value":"11","value_num":11,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"national","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["EPA's recommendation under Clean Water Act § 304(a): 'State and Tribal governments may use these criteria or use them as guidance in developing their own' — it binds a water once the state adopts it for the water's designated use","receiving_water is freshwater","Freshwater CCC (chronic): criterion continuous concentration, chronic"],"cite":{"instrument":"us_nrwqc_aquatic","title":"EPA National Recommended Water Quality Criteria — Aquatic Life Criteria Table (freshwater and saltwater CMC/CCC)","issuer":"U.S. Environmental Protection Agency","edition":"EPA web table, last updated on June 9, 2026 (fetched 2026-10-09); each criterion carries its publication year","source_url":"https://www.epa.gov/wqc/national-recommended-water-quality-criteria-aquatic-life-criteria-table","source_sha256":"be6b429558db9852c3456eb22c17046aa1a3335ee89e702e8afb793f9b5b25ec","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"not verified"},"section":"National Recommended Aquatic Life Criteria table","page":null,"quote":"Chromium (VI) (P) 18540299 16 11 1,100 50 1995"}},{"id":"b5bb9da8ab4d8593","parameter":"Chromium (VI)","value":"1,100","value_num":1100,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"national","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["EPA's recommendation under Clean Water Act § 304(a): 'State and Tribal governments may use these criteria or use them as guidance in developing their own' — it binds a water once the state adopts it for the water's designated use","receiving_water is marine","Saltwater CMC (acute): criterion maximum concentration, acute"],"cite":{"instrument":"us_nrwqc_aquatic","title":"EPA National Recommended Water Quality Criteria — Aquatic Life Criteria Table (freshwater and saltwater CMC/CCC)","issuer":"U.S. Environmental Protection Agency","edition":"EPA web table, last updated on June 9, 2026 (fetched 2026-10-09); each criterion carries its publication year","source_url":"https://www.epa.gov/wqc/national-recommended-water-quality-criteria-aquatic-life-criteria-table","source_sha256":"be6b429558db9852c3456eb22c17046aa1a3335ee89e702e8afb793f9b5b25ec","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"not verified"},"section":"National Recommended Aquatic Life Criteria table","page":null,"quote":"Chromium (VI) (P) 18540299 16 11 1,100 50 1995"}},{"id":"7881e361697154d6","parameter":"Chromium (VI)","value":"50","value_num":50,"unit":"µg/L","direction":"max","kind":"guideline","medium":"surface_water","level":"national","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["EPA's recommendation under Clean Water Act § 304(a): 'State and Tribal governments may use these criteria or use them as guidance in developing their own' — it binds a water once the state adopts it for the water's designated use","receiving_water is marine","Saltwater CCC (chronic): criterion continuous concentration, chronic"],"cite":{"instrument":"us_nrwqc_aquatic","title":"EPA National Recommended Water Quality Criteria — Aquatic Life Criteria Table (freshwater and saltwater CMC/CCC)","issuer":"U.S. Environmental Protection Agency","edition":"EPA web table, last updated on June 9, 2026 (fetched 2026-10-09); each criterion carries its publication year","source_url":"https://www.epa.gov/wqc/national-recommended-water-quality-criteria-aquatic-life-criteria-table","source_sha256":"be6b429558db9852c3456eb22c17046aa1a3335ee89e702e8afb793f9b5b25ec","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"not verified"},"section":"National Recommended Aquatic Life Criteria table","page":null,"quote":"Chromium (VI) (P) 18540299 16 11 1,100 50 1995"}},{"id":"ae53e44ca2aae726","parameter":"Chromium(VI)","value":"0.95","value_num":0.95,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"national","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["Resident Soil (mg/kg)"],"cite":{"instrument":"us_rsl_soil","title":"US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Soil","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"November 2024","source_url":"https://semspub.epa.gov/src/document/HQ/405270","source_sha256":"0160dc81b4f55d738a354a74de92488f149946ebfa7c6a6c64592f45348043d7","fetched_at":"2026-09-19","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":null,"page":null,"quote":null,"table":"sols","column":"residentiel"}},{"id":"845db22b1086f459","parameter":"Chromium(VI)","value":"20","value_num":20,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"national","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["Industrial Soil (mg/kg)"],"cite":{"instrument":"us_rsl_soil","title":"US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Soil","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"November 2024","source_url":"https://semspub.epa.gov/src/document/HQ/405270","source_sha256":"0160dc81b4f55d738a354a74de92488f149946ebfa7c6a6c64592f45348043d7","fetched_at":"2026-09-19","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":null,"page":null,"quote":null,"table":"sols","column":"industriel"}},{"id":"14622c9bffeba9a6","parameter":"Chromium(VI)","value":"0.0021","value_num":0.0021,"unit":"mg/kg","direction":"max","kind":"guideline","medium":"soil","level":"national","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["Protection of Groundwater SSLs: Risk-based SSL (mg/kg); SSL values are based on DAF=1"],"cite":{"instrument":"us_rsl_soil","title":"US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Soil","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"November 2024","source_url":"https://semspub.epa.gov/src/document/HQ/405270","source_sha256":"0160dc81b4f55d738a354a74de92488f149946ebfa7c6a6c64592f45348043d7","fetched_at":"2026-09-19","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":null,"page":null,"quote":null,"table":"ssl","column":"risque"}},{"id":"db22b9350cce0488","parameter":"Chromium(VI)","value":"0.11","value_num":0.11,"unit":"µg/L","direction":"max","kind":"guideline","medium":"drinking_water","level":"national","parameter_key":"cas:18540-29-9","place":["US"],"conditions":["Tap Water (ug/L): Regional Screening Level (RSL) Summary Table (TR=1E-06, HQ=1) November 2024"],"cite":{"instrument":"us_rsl_tapwater","title":"US EPA — Regional Screening Levels (RSLs), Summary Table (TR=1E-06, THQ=1.0), November 2024 — Tap Water","issuer":"U.S. Environmental Protection Agency (EPA)","edition":"November 2024","source_url":"https://semspub.epa.gov/src/document/HQ/405270","source_sha256":"0160dc81b4f55d738a354a74de92488f149946ebfa7c6a6c64592f45348043d7","fetched_at":"2026-09-19","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":null,"page":null,"quote":null,"table":"eau","column":"eau_robinet"}}],"next":[{"tool":"check_values","says":"Has your user measured this? check_values sets each of their results beside every row held here, with a verdict and the row's cite.","arguments":{"place":"US-FL"},"needs":{"rows":"Your user's measured results, as their table prints them: [{parameter: \"chromium vi\", value, unit}, ...], any other parameters too."},"post":"/api/v1/check","url":"https://passage-data.com/api/v1/check","page":"https://passage-data.com/limits/US-FL/chromium-vi#check"},{"tool":"read_certificate","says":"Has your user a laboratory certificate? read_certificate reads every row it prints, each with its page, and checks them against these limits.","arguments":{"place":"US-FL"},"needs":{"content_base64":"The laboratory's certificate (PDF) or its XLSX, XLS or CSV export, as base64; or file_url, a public https address of it."},"post":"/api/v1/certificate","url":"https://passage-data.com/api/v1/certificate","page":"https://passage-data.com/limits/US-FL/chromium-vi#check"}]}