{"query":{"parameter":"aluminum","place":"US-KS","medium":null,"statistic":null,"kind":null},"searched":{"places":["US-KS","US"],"parameter_keys":["cas:7429-90-5","cas:139-12-8","cas:1327-41-9","name:aluminum - dissolved","name:aluminum, ionic","cas:13776-88-0","cas:20859-73-8","cas:12736-96-8","name:~aluminum salts of inorganic phosphates","cas:7785-88-8","name:aluminum, total","cas:39148-24-8","cas:7784-30-7","cas:13530-50-2","cas:92203-02-6","cas:10279-59-1","cas:10305-76-7","name:total aluminum","name:total recoverable aluminum","cas:13939-25-8","name:fer, aluminium et composes"],"names_matched":[["aluminum","cas:7429-90-5"],["acetic acid aluminum salt","cas:139-12-8"],["aluminum chloride hydroxide","cas:1327-41-9"],["aluminum dissolved","name:aluminum - dissolved"],["aluminum ionic","name:aluminum, ionic"],["aluminum metaphosphate","cas:13776-88-0"],["aluminum phosphide","cas:20859-73-8"],["aluminum potassium sodium silicate","cas:12736-96-8"],["aluminum salts of inorganic phosphates","name:~aluminum salts of inorganic phosphates"],["aluminum sodium phosphate","cas:7785-88-8"],["aluminum total","name:aluminum, total"],["aluminum tris o ethylphosphonate","cas:39148-24-8"],["dissolved aluminum","name:aluminum - dissolved"],["metaphosphoric acid hpo3 aluminum salt","cas:13776-88-0"],["phosphoric acid aluminum salt 1 1 aluminum phosphate","cas:7784-30-7"],["phosphoric acid aluminum salt 3 1","cas:13530-50-2"],["phosphoric acid aluminum sodium salt 1 x x sodium aluminum phosphate acidic acidic salp","cas:7785-88-8"],["phosphoric acid reaction products with aluminum hydroxide and chromium oxide cro3","cas:92203-02-6"],["silicic acid aluminum potassium sodium salt","cas:12736-96-8"],["sodium aluminum phosphate anhydrous","cas:10279-59-1"],["sodium aluminum phosphate tetrahydrate","cas:10305-76-7"],["total aluminum","name:aluminum, total"],["total aluminum","name:total aluminum"],["total recoverable aluminum","name:total recoverable aluminum"],["triphosphoric acid aluminum salt 1 1","cas:13939-25-8"],["triphosphoric acid aluminum salt 1 1 aluminum triphosphate","cas:13939-25-8"],["fer aluminium et composes","name:fer, aluminium et composes","aluminium"],["fer aluminium et composes en fe al","name:fer, aluminium et composes","aluminium"],["triacetate d aluminium","cas:139-12-8","aluminium"]],"match":"exact+contains","order":"The place's own instruments first, then each place above it, each in its register's order","not_sent":{"rows":7,"names":["Fosetyl-AL","~Monoaluminum phosphate"],"says":"7 rows share a parameter key with a longer name holding \"aluminum\" but are printed under names without these words (that key is wider than the name): not sent. Ask for one by its name or CAS number."}},"total":402,"offset":0,"returned":200,"next_offset":200,"rows":[{"id":"6417c367198e13ad","parameter":"Aluminum","value":".831","value_num":0.831,"unit":"mg/kg (pounds per million pounds) of paste produced","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(a) Subpart B—Anode and Cathode Paste Plant Wet Air Pollution Control","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum .831 .369"}},{"id":"0c254be0e5ee02e5","parameter":"Aluminum","value":".369","value_num":0.369,"unit":"mg/kg (pounds per million pounds) of paste produced","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(a) Subpart B—Anode and Cathode Paste Plant Wet Air Pollution Control","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum .831 .369"}},{"id":"8ad6d4255118afb7","parameter":"Aluminum","value":"1.277","value_num":1.277,"unit":"mg/kg (pounds per million pounds) of anodes cast","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(b) Subpart (B)—Anode Contact Cooling and Briquette Quenching.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 1.277 .566"}},{"id":"91260c4efefe3f85","parameter":"Aluminum","value":".566","value_num":0.566,"unit":"mg/kg (pounds per million pounds) of anodes cast","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(b) Subpart (B)—Anode Contact Cooling and Briquette Quenching.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 1.277 .566"}},{"id":"9d71ef0192a8392e","parameter":"Aluminum","value":"26.420","value_num":26.42,"unit":"mg/kg (pounds per million pounds) of anodes baked","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(c) Subpart (B)—Anode Bake Plant Wet Air Pollution Control (Closed Top Ring Furnace).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 26.420 11.720"}},{"id":"cf103a9ce09caf36","parameter":"Aluminum","value":"11.720","value_num":11.72,"unit":"mg/kg (pounds per million pounds) of anodes baked","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(c) Subpart (B)—Anode Bake Plant Wet Air Pollution Control (Closed Top Ring Furnace).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 26.420 11.720"}},{"id":"a0ffda8996693367","parameter":"Aluminum","value":".306","value_num":0.306,"unit":"mg/kg (pounds per million pounds) of anodes baked","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(d) Subpart B—Anode Bake Plant Wet Air Pollution Control (Open Top Ring Furnace With Spray Tower Only).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum .306 .136"}},{"id":"119d9fe26a8b85f2","parameter":"Aluminum","value":".136","value_num":0.136,"unit":"mg/kg (pounds per million pounds) of anodes baked","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(d) Subpart B—Anode Bake Plant Wet Air Pollution Control (Open Top Ring Furnace With Spray Tower Only).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum .306 .136"}},{"id":"ed78aa40eaaaf1f8","parameter":"Aluminum","value":"4.461","value_num":4.461,"unit":"mg/kg (pounds per million pounds) of anodes baked","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(e) Subpart B—Anode Bake Plant Wet Air Pollution Control (Open Top Ring Furnace With Wet Electrostatic Precipitator and Spray Tower).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 4.461 1.979"}},{"id":"6c15c2aa2071ac07","parameter":"Aluminum","value":"1.979","value_num":1.979,"unit":"mg/kg (pounds per million pounds) of anodes baked","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(e) Subpart B—Anode Bake Plant Wet Air Pollution Control (Open Top Ring Furnace With Wet Electrostatic Precipitator and Spray Tower).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 4.461 1.979"}},{"id":"09196720123d5a14","parameter":"Aluminum","value":"6.953","value_num":6.953,"unit":"mg/kg (pounds per million pounds) of anodes baked","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(f) Subpart B—Anode Bake Plant Wet Air Pollution Control (Tunnel Kiln).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 6.953 3.084"}},{"id":"ee6d11049e6fafa4","parameter":"Aluminum","value":"3.084","value_num":3.084,"unit":"mg/kg (pounds per million pounds) of anodes baked","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(f) Subpart B—Anode Bake Plant Wet Air Pollution Control (Tunnel Kiln).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 6.953 3.084"}},{"id":"e56df52947caa9b5","parameter":"Aluminum","value":"273.200","value_num":273.2,"unit":"mg/kg (pounds per million pounds) of cryolite recovered","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(g) Subpart B—Cathode Reprocessing (Operated With Dry Potline Scrubbing and Not Commingled With Other Process or Nonprocess Waters).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 273.200 122.600"}},{"id":"f2fb9be480698ad4","parameter":"Aluminum","value":"122.600","value_num":122.6,"unit":"mg/kg (pounds per million pounds) of cryolite recovered","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(g) Subpart B—Cathode Reprocessing (Operated With Dry Potline Scrubbing and Not Commingled With Other Process or Nonprocess Waters).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 273.200 122.600"}},{"id":"1dc8e6e54e4f0559","parameter":"Aluminum","value":"214.000","value_num":214,"unit":"mg/kg (pounds per million pounds) of cryolite recovered","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(h) Subpart B—Cathode Reprocessing (Operated With Dry Potline Scrubbing and Commingled With Other Process or Nonprocess Waters).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 214.000 94.930"}},{"id":"88f332a67dbe4506","parameter":"Aluminum","value":"94.930","value_num":94.93,"unit":"mg/kg (pounds per million pounds) of cryolite recovered","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(h) Subpart B—Cathode Reprocessing (Operated With Dry Potline Scrubbing and Commingled With Other Process or Nonprocess Waters).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 214.000 94.930"}},{"id":"b8ec79ce586c54dc","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of cryolite recovered","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(i) Subpart B—Cathode Reprocessing (Operated With Wet Potline Scrubbing).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum .000 .000"}},{"id":"868e17fcf5cc32bf","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of cryolite recovered","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(i) Subpart B—Cathode Reprocessing (Operated With Wet Potline Scrubbing).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum .000 .000"}},{"id":"752d0dbda3a752d1","parameter":"Aluminum","value":"5.120","value_num":5.12,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(j) Subpart B—Potline Wet Air Pollution Control (Operated Without Cathode Reprocessing).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 5.120 2.271"}},{"id":"d5c6a515516f6e53","parameter":"Aluminum","value":"2.271","value_num":2.271,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(j) Subpart B—Potline Wet Air Pollution Control (Operated Without Cathode Reprocessing).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 5.120 2.271"}},{"id":"9a042b1e59b2f62b","parameter":"Aluminum","value":"6.537","value_num":6.537,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(k) Subpart B—Potline Wet Air Pollution Control (Operated With Cathode Reprocessing and Not Commingled With Other Process or Nonprocess Waters).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 6.537 2.933"}},{"id":"7daec4b785ea9b33","parameter":"Aluminum","value":"2.933","value_num":2.933,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(k) Subpart B—Potline Wet Air Pollution Control (Operated With Cathode Reprocessing and Not Commingled With Other Process or Nonprocess Waters).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 6.537 2.933"}},{"id":"8c1a646117c0e71b","parameter":"Aluminum","value":"5.120","value_num":5.12,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(l) Potline Wet Air Pollution Control Cooperated With Cathode Reprocessing and Commingled With Other Process or Nonprocess Wastewaters).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 5.120 2.271"}},{"id":"2836498e56ba8e94","parameter":"Aluminum","value":"2.271","value_num":2.271,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(l) Potline Wet Air Pollution Control Cooperated With Cathode Reprocessing and Commingled With Other Process or Nonprocess Wastewaters).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 5.120 2.271"}},{"id":"710bcff102b223c5","parameter":"Aluminum","value":"10.140","value_num":10.14,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(m) Subpart B—Potroom Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 10.140 4.499"}},{"id":"152fa4844705512e","parameter":"Aluminum","value":"4.499","value_num":4.499,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(m) Subpart B—Potroom Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 10.140 4.499"}},{"id":"f267cfe14cc9d0a1","parameter":"Aluminum","value":"8.194","value_num":8.194,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(n) Subpart B—Potline SO 2 Emissions Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 8.194 3.634"}},{"id":"69fd4d4100461a3b","parameter":"Aluminum","value":"3.634","value_num":3.634,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(n) Subpart B—Potline SO 2 Emissions Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 8.194 3.634"}},{"id":"48480b16443eecd9","parameter":"Aluminum","value":"15.940","value_num":15.94,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(o) Subpart B—Degassing Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 15.940 7.071"}},{"id":"2f61068a1fc9ba21","parameter":"Aluminum","value":"7.071","value_num":7.071,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(o) Subpart B—Degassing Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 15.940 7.071"}},{"id":"030f14a516d06e85","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(p) Subpart B—Pot Repair and Pot Soaking.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum .000 .000"}},{"id":"8f67a2b85eb4b75a","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(p) Subpart B—Pot Repair and Pot Soaking.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum .000 .000"}},{"id":"72bc02efd70ba1be","parameter":"Aluminum","value":"8.120","value_num":8.12,"unit":"mg/kg (pound per million pounds) of aluminum product from direct chill casting","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(q) Subpart B—Direct Chill Casting Contact Cooling.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 8.120 3.602"}},{"id":"ecff91bcfb11b982","parameter":"Aluminum","value":"3.602","value_num":3.602,"unit":"mg/kg (pound per million pounds) of aluminum product from direct chill casting","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(q) Subpart B—Direct Chill Casting Contact Cooling.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum 8.120 3.602"}},{"id":"2bcf1eb882e97735","parameter":"Aluminum","value":".636","value_num":0.636,"unit":"mg/kg (pound per million pounds) of aluminum product from rod casting","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(r) Subpart B—Continuous Rod Casting Contact Cooling.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum .636 .282"}},{"id":"d66081a3251945c8","parameter":"Aluminum","value":".282","value_num":0.282,"unit":"mg/kg (pound per million pounds) of aluminum product from rod casting","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(r) Subpart B—Continuous Rod Casting Contact Cooling.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum .636 .282"}},{"id":"6e050841eacf1173","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of aluminum product from stationary casting or shot casting","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(s) Subpart B—Stationary Casting or Shot Casting Contact Cooling.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum .000 .000"}},{"id":"7b0018d5d07c4cf2","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of aluminum product from stationary casting or shot casting","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","existing sources (BAT)","(s) Subpart B—Stationary Casting or Shot Casting Contact Cooling.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.23 (BAT)","page":null,"quote":"Aluminum .000 .000"}},{"id":"c79f8577da0e14ee","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of paste produced","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(a) Subpart B—Anode and Cathode Paste Plant Wet Air.","table: Pollution Control—NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Aluminum .000 .000"}},{"id":"941711ea52f9f0a8","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of paste produced","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(a) Subpart B—Anode and Cathode Paste Plant Wet Air.","table: Pollution Control—NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Aluminum .000 .000"}},{"id":"34bf509e0ca49953","parameter":"Aluminum","value":"1.277","value_num":1.277,"unit":"mg/kg (pound per million pounds) of anodes cast","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(b) Subpart B—Anode Contact Cooling and Briquette Quenching.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Aluminum 1.277 .566"}},{"id":"4362391bd248e336","parameter":"Aluminum","value":".566","value_num":0.566,"unit":"mg/kg (pound per million pounds) of anodes cast","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(b) Subpart B—Anode Contact Cooling and Briquette Quenching.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Aluminum 1.277 .566"}},{"id":"59d8c7b78a4c0a11","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of anodes baked","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(c) Subpart B—Anode Bake Plant Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Aluminum .000 .000"}},{"id":"4f1b088de2fabe83","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of anodes baked","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(c) Subpart B—Anode Bake Plant Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Aluminum .000 .000"}},{"id":"37020fde6252e3bc","parameter":"Aluminum","value":"273.200","value_num":273.2,"unit":"mg/kg (pound per million pounds) of cryolite recovered","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(d) Subpart B—Cathode Reprocessing (Operated With Dry Potline Scrubbing and Not Commingled With Other Process or Nonprocess Waters).","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Aluminum 273.200 122.600"}},{"id":"923be3ceccbb7c18","parameter":"Aluminum","value":"122.600","value_num":122.6,"unit":"mg/kg (pound per million pounds) of cryolite recovered","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(d) Subpart B—Cathode Reprocessing (Operated With Dry Potline Scrubbing and Not Commingled With Other Process or Nonprocess Waters).","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Aluminum 273.200 122.600"}},{"id":"5cc45cb7a7eaf6e3","parameter":"Aluminum","value":"214.000","value_num":214,"unit":"mg/kg (pound per million pounds) of cryolite recovered","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(e) Subpart B—Cathode Reprocessing (Operated With Dry Potline Scrubbing and Commingled With Other Process or Nonprocess Waters).","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Aluminum 214.000 94.930"}},{"id":"e66986ae561e7dc9","parameter":"Aluminum","value":"94.930","value_num":94.93,"unit":"mg/kg (pound per million pounds) of cryolite recovered","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(e) Subpart B—Cathode Reprocessing (Operated With Dry Potline Scrubbing and Commingled With Other Process or Nonprocess Waters).","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Aluminum 214.000 94.930"}},{"id":"50edf2cf5639b9e9","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(f) Subpart B—Potline Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Aluminum .000 .000"}},{"id":"bf87aca78d9ef3c3","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(f) Subpart B—Potline Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Aluminum .000 .000"}},{"id":"6f26c4656987cf4a","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(g) Subpart B—Potroom Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Aluminum .000 .000"}},{"id":"23b82c2f954410a3","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(g) Subpart B—Potroom Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Aluminum .000 .000"}},{"id":"a91b9fedde3f36b7","parameter":"Aluminum","value":"8.194","value_num":8.194,"unit":"mg/kg (pound per million pounds) aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(h) Subpart B—Potline SO 2 Emissions Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Aluminum 8.194 3.634"}},{"id":"2c88652e8fe76041","parameter":"Aluminum","value":"3.634","value_num":3.634,"unit":"mg/kg (pound per million pounds) aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(h) Subpart B—Potline SO 2 Emissions Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Aluminum 8.194 3.634"}},{"id":"1d7e8bb730efce2b","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(i) Subpart B—Degassing Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Aluminum .000 .000"}},{"id":"29798eaaa2e978f8","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(i) Subpart B—Degassing Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Aluminum .000 .000"}},{"id":"cc03f86719107078","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(j) Subpart B—Pot Repair and Pot Soaking.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Aluminum .000 .000"}},{"id":"a54a2bb6dc0b7ba7","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pound per million pounds) of aluminum produced from electrolytic reduction","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(j) Subpart B—Pot Repair and Pot Soaking.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Aluminum .000 .000"}},{"id":"32f2417f39402982","parameter":"Aluminum","value":"8.120","value_num":8.12,"unit":"mg/kg (pound per million pounds) of aluminum product from direct chill casting","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(k) Subpart B—Direct Chill Casting Contact Cooling.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Aluminum 8.120 3.602"}},{"id":"96d7d8b3f4a6f030","parameter":"Aluminum","value":"3.602","value_num":3.602,"unit":"mg/kg (pound per million pounds) of aluminum product from direct chill casting","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(k) Subpart B—Direct Chill Casting Contact Cooling.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Aluminum 8.120 3.602"}},{"id":"8972596eba399c7e","parameter":"Aluminum","value":".636","value_num":0.636,"unit":"mg/kg (pound per million pounds) of aluminum product from rod casting","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(l) Subpart B—Continuous Rod Casting Contact Cooling.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Aluminum .636 .282"}},{"id":"b923c278f3b5f496","parameter":"Aluminum","value":".282","value_num":0.282,"unit":"mg/kg (pound per million pounds) of aluminum product from rod casting","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(l) Subpart B—Continuous Rod Casting Contact Cooling.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Aluminum .636 .282"}},{"id":"77ba710c06a11e0a","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of aluminum product from stationary casting or shot casting","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(m) Subpart B—Stationary Casting or Shot Casting Contact Cooling.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Aluminum .000 .000"}},{"id":"0e0b1321dad9bd31","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of aluminum product from stationary casting or shot casting","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart B—Primary Aluminum Smelting Subcategory","new sources (NSPS)","(m) Subpart B—Stationary Casting or Shot Casting Contact Cooling.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.24 (NSPS)","page":null,"quote":"Aluminum .000 .000"}},{"id":"bc4a27ebb3e77f6b","parameter":"Aluminum","value":"1.0","value_num":1,"unit":"kilograms per 1,000 kg of product","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","existing sources (BPT)","(d) The following limitations establish the quantity or quality of pollutants or pollutant properties which may be discharged by a point source subject to the provisions of this subpart and which processes residues by wet methods, after application of the best practical control technology currently available:","table: Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.32 (BPT)","page":null,"quote":"Aluminum 1.0"}},{"id":"e23af8cbb8cead7e","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pound's per million pounds) of aluminum scrap dried","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","existing sources (BAT)","(a) Subpart C—Scrap Drying Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.33 (BAT)","page":null,"quote":"Aluminum .000 .000"}},{"id":"7e6e743114ac24b8","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pound's per million pounds) of aluminum scrap dried","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","existing sources (BAT)","(a) Subpart C—Scrap Drying Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.33 (BAT)","page":null,"quote":"Aluminum .000 .000"}},{"id":"e06f8a5793bde9db","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pound's per million pounds) of aluminum scrap screened and milled","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","existing sources (BAT)","(b) Subpart C—Scrap Screening and Milling.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.33 (BAT)","page":null,"quote":"Aluminum .000 .000"}},{"id":"68a1bc262596dfd5","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pound's per million pounds) of aluminum scrap screened and milled","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","existing sources (BAT)","(b) Subpart C—Scrap Screening and Milling.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.33 (BAT)","page":null,"quote":"Aluminum .000 .000"}},{"id":"91abcd2928ad99d0","parameter":"Aluminum","value":"66.410","value_num":66.41,"unit":"mg/kg (pound's per million pounds) of dross washed","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","existing sources (BAT)","(c) Subpart C—Dross Washing.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.33 (BAT)","page":null,"quote":"Aluminum 66.410 29.450"}},{"id":"eb683a6d3441c0cf","parameter":"Aluminum","value":"29.450","value_num":29.45,"unit":"mg/kg (pound's per million pounds) of dross washed","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","existing sources (BAT)","(c) Subpart C—Dross Washing.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.33 (BAT)","page":null,"quote":"Aluminum 66.410 29.450"}},{"id":"61c6ac0e0cc1799a","parameter":"Aluminum","value":"4.711","value_num":4.711,"unit":"mg/kg (lb/million lbs) of aluminum demagged","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","existing sources (BAT)","(d) Subpart C—Demagging Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.33 (BAT)","page":null,"quote":"Aluminum 4.711 2.090"}},{"id":"24c1066ab53d5798","parameter":"Aluminum","value":"2.090","value_num":2.09,"unit":"mg/kg (lb/million lbs) of aluminum demagged","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","existing sources (BAT)","(d) Subpart C—Demagging Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.33 (BAT)","page":null,"quote":"Aluminum 4.711 2.090"}},{"id":"38213ed6ec55467e","parameter":"Aluminum","value":"2.035","value_num":2.035,"unit":"mg/kg (pound's per million pounds) of aluminum delacquered","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","existing sources (BAT)","(e) Subpart C—Delacquering Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.33 (BAT)","page":null,"quote":"Aluminum 2.035 0.903"}},{"id":"0f097aeeef6dd93d","parameter":"Aluminum","value":"0.903","value_num":0.903,"unit":"mg/kg (pound's per million pounds) of aluminum delacquered","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","existing sources (BAT)","(e) Subpart C—Delacquering Wet Air Pollution Control.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.33 (BAT)","page":null,"quote":"Aluminum 2.035 0.903"}},{"id":"4b3041deb713fefa","parameter":"Aluminum","value":"8.120","value_num":8.12,"unit":"mg/kg (pounds per million pounds) of aluminum cast","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","existing sources (BAT)","(f) Subpart C—Direct Chill Casting Contact Cooling.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.33 (BAT)","page":null,"quote":"Aluminum 8.120 3.602"}},{"id":"9cd63001d1231ed7","parameter":"Aluminum","value":"3.602","value_num":3.602,"unit":"mg/kg (pounds per million pounds) of aluminum cast","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","existing sources (BAT)","(f) Subpart C—Direct Chill Casting Contact Cooling.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.33 (BAT)","page":null,"quote":"Aluminum 8.120 3.602"}},{"id":"b61b772ed5fb3e9d","parameter":"Aluminum","value":"0.409","value_num":0.409,"unit":"mg/kg (lb/million lbs) of aluminum cast","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","existing sources (BAT)","(g) Subpart C—Ingot Conveyor Casting Contact Cooling (When Chlorine Demagging Wet Air Pollution Control is Not Practiced On-Site).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.33 (BAT)","page":null,"quote":"Aluminum 0.409 0.182"}},{"id":"0de4b4d12cdd40d5","parameter":"Aluminum","value":"0.182","value_num":0.182,"unit":"mg/kg (lb/million lbs) of aluminum cast","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","existing sources (BAT)","(g) Subpart C—Ingot Conveyor Casting Contact Cooling (When Chlorine Demagging Wet Air Pollution Control is Not Practiced On-Site).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.33 (BAT)","page":null,"quote":"Aluminum 0.409 0.182"}},{"id":"99439347547d84fb","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of aluminum cast","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","existing sources (BAT)","(h) Subpart C—Ingot Conveyor Casting Contact Cooling (When Chloride Demagging Wet Air Pollution Control is Practiced On Site).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.33 (BAT)","page":null,"quote":"Aluminum .000 .000"}},{"id":"dffe56818925c277","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of aluminum cast","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","existing sources (BAT)","(h) Subpart C—Ingot Conveyor Casting Contact Cooling (When Chloride Demagging Wet Air Pollution Control is Practiced On Site).","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.33 (BAT)","page":null,"quote":"Aluminum .000 .000"}},{"id":"e9a25f2eefd4ea8d","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of aluminum cast","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","existing sources (BAT)","(i) Subpart C—Stationary Casting Contact Cooling.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.33 (BAT)","page":null,"quote":"Aluminum .000 .000"}},{"id":"ecd57f390e4f5c40","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of aluminum cast","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","existing sources (BAT)","(i) Subpart C—Stationary Casting Contact Cooling.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.33 (BAT)","page":null,"quote":"Aluminum .000 .000"}},{"id":"7a07e95f420c3368","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of aluminum cast","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","existing sources (BAT)","(j) Subpart C—Shot Casting Contact Cooling.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.33 (BAT)","page":null,"quote":"Aluminum .000 .000"}},{"id":"1e6ad8e1052e3c19","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of aluminum cast","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","existing sources (BAT)","(j) Subpart C—Shot Casting Contact Cooling.","table: BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.33 (BAT)","page":null,"quote":"Aluminum .000 .000"}},{"id":"5b93295e5015da08","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of aluminum scrap dried","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","new sources (NSPS)","(a) Subpart C—Scrap Drying Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.34 (NSPS)","page":null,"quote":"Aluminum .000 .000"}},{"id":"f27643cca8b26631","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of aluminum scrap dried","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","new sources (NSPS)","(a) Subpart C—Scrap Drying Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.34 (NSPS)","page":null,"quote":"Aluminum .000 .000"}},{"id":"643c736adbf63a7c","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of aluminum scrap screened and milled","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","new sources (NSPS)","(b) Subpart C—Scrap Screening and Milling.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.34 (NSPS)","page":null,"quote":"Aluminum .000 .000"}},{"id":"b59b43ce9ddc0bef","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of aluminum scrap screened and milled","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","new sources (NSPS)","(b) Subpart C—Scrap Screening and Milling.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.34 (NSPS)","page":null,"quote":"Aluminum .000 .000"}},{"id":"7d0a1e1472fcfc36","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of dross washed","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","new sources (NSPS)","(c) Subpart C—Dross Washing.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.34 (NSPS)","page":null,"quote":"Aluminum .000 .000"}},{"id":"ed6fde07d95eb04c","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of dross washed","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","new sources (NSPS)","(c) Subpart C—Dross Washing.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.34 (NSPS)","page":null,"quote":"Aluminum .000 .000"}},{"id":"90c8ad55b9468da2","parameter":"Aluminum","value":"4.711","value_num":4.711,"unit":"mg/kg (lb/million lbs) of aluminum demagged","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","new sources (NSPS)","(d) Subpart C—Demagging Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.34 (NSPS)","page":null,"quote":"Aluminum 4.711 2.090"}},{"id":"7652bcd56aef9c7c","parameter":"Aluminum","value":"2.090","value_num":2.09,"unit":"mg/kg (lb/million lbs) of aluminum demagged","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","new sources (NSPS)","(d) Subpart C—Demagging Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.34 (NSPS)","page":null,"quote":"Aluminum 4.711 2.090"}},{"id":"aa6b565071ffe951","parameter":"Aluminum","value":"2.035","value_num":2.035,"unit":"mg/kg (pounds per million pounds) of aluminum delacquered","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","new sources (NSPS)","(e) Subpart C—Delacquering Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.34 (NSPS)","page":null,"quote":"Aluminum 2.035 0.903"}},{"id":"cf9f35175e0b5b0d","parameter":"Aluminum","value":"0.903","value_num":0.903,"unit":"mg/kg (pounds per million pounds) of aluminum delacquered","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","new sources (NSPS)","(e) Subpart C—Delacquering Wet Air Pollution Control.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.34 (NSPS)","page":null,"quote":"Aluminum 2.035 0.903"}},{"id":"5eda67ee13ae202f","parameter":"Aluminum","value":"8.120","value_num":8.12,"unit":"mg/kg (pounds per million pounds) of aluminum cast","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","new sources (NSPS)","(f) Subpart C—Direct Chill Casting Contact Cooling.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.34 (NSPS)","page":null,"quote":"Aluminum 8.120 3.602"}},{"id":"aaf53ee28b65286d","parameter":"Aluminum","value":"3.602","value_num":3.602,"unit":"mg/kg (pounds per million pounds) of aluminum cast","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","new sources (NSPS)","(f) Subpart C—Direct Chill Casting Contact Cooling.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.34 (NSPS)","page":null,"quote":"Aluminum 8.120 3.602"}},{"id":"752448749c5244cd","parameter":"Aluminum","value":"0.409","value_num":0.409,"unit":"mg/kg (lb/million lbs) of aluminum cast","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","new sources (NSPS)","(g) Subpart C—Ingot Conveyor Casting Contact Cooling (When Chlorine Demagging Wet Air Pollution Control is Not Practiced On-Site).","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.34 (NSPS)","page":null,"quote":"Aluminum 0.409 0.182"}},{"id":"77057cb2f72b5038","parameter":"Aluminum","value":"0.182","value_num":0.182,"unit":"mg/kg (lb/million lbs) of aluminum cast","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","new sources (NSPS)","(g) Subpart C—Ingot Conveyor Casting Contact Cooling (When Chlorine Demagging Wet Air Pollution Control is Not Practiced On-Site).","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.34 (NSPS)","page":null,"quote":"Aluminum 0.409 0.182"}},{"id":"a86b208f4025a6eb","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of aluminum cast","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","new sources (NSPS)","(h) Subpart C—Ingot Conveyor Casting Contact Cooling (When Chlorine Demagging Wet Air Pollution Control is Practiced On Site).","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.34 (NSPS)","page":null,"quote":"Aluminum .000 .000"}},{"id":"7731572737b28962","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of aluminum cast","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","new sources (NSPS)","(h) Subpart C—Ingot Conveyor Casting Contact Cooling (When Chlorine Demagging Wet Air Pollution Control is Practiced On Site).","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.34 (NSPS)","page":null,"quote":"Aluminum .000 .000"}},{"id":"640c30c6387e9899","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of aluminum cast","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","new sources (NSPS)","(i) Subpart C—Stationary Casting Contact Cooling.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.34 (NSPS)","page":null,"quote":"Aluminum .000 .000"}},{"id":"7f336d577f7d06ac","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of aluminum cast","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","new sources (NSPS)","(i) Subpart C—Stationary Casting Contact Cooling.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.34 (NSPS)","page":null,"quote":"Aluminum .000 .000"}},{"id":"aa140c7b3ea4fcd9","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of aluminum cast","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","new sources (NSPS)","(j) Subpart C—Shot Casting Contact Cooling.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.34 (NSPS)","page":null,"quote":"Aluminum .000 .000"}},{"id":"eeee7c01795f6edd","parameter":"Aluminum","value":".000","value_num":0,"unit":"mg/kg (pounds per million pounds) of aluminum cast","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 421","the discharge is of the Subpart C—Secondary Aluminum Smelting Subcategory","new sources (NSPS)","(j) Subpart C—Shot Casting Contact Cooling.","table: NSPS"],"cite":{"instrument":"us_40cfr421","title":"40 CFR Part 421 — PART 421—NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=421","source_sha256":"d7cfd73b5bcf0e961e02ec53264492b2371277280003192841b7166b2a5012cf","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 421.34 (NSPS)","page":null,"quote":"Aluminum .000 .000"}},{"id":"e8dcd1b47afeb3a5","parameter":"Al","value":"2.0","value_num":2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 440","the discharge is of the Subpart B—Aluminum Ore Subcategory","existing sources (BAT)"],"cite":{"instrument":"us_40cfr440","title":"40 CFR Part 440 — PART 440—ORE MINING AND DRESSING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=440","source_sha256":"aea3b68c1fc9aac4ea3fa56240df79cf606e97c278fd0b499c3ec190dad2ee9a","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 440.23 (BAT)","page":null,"quote":"Al 2.0 1.0"}},{"id":"bb7cde02760080a1","parameter":"Al","value":"1.0","value_num":1,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 440","the discharge is of the Subpart B—Aluminum Ore Subcategory","existing sources (BAT)"],"cite":{"instrument":"us_40cfr440","title":"40 CFR Part 440 — PART 440—ORE MINING AND DRESSING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=440","source_sha256":"aea3b68c1fc9aac4ea3fa56240df79cf606e97c278fd0b499c3ec190dad2ee9a","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 440.23 (BAT)","page":null,"quote":"Al 2.0 1.0"}},{"id":"89d346c60d99afd4","parameter":"Al","value":"2.0","value_num":2,"unit":"mg/L","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 440","the discharge is of the Subpart B—Aluminum Ore Subcategory","new sources (NSPS)"],"cite":{"instrument":"us_40cfr440","title":"40 CFR Part 440 — PART 440—ORE MINING AND DRESSING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=440","source_sha256":"aea3b68c1fc9aac4ea3fa56240df79cf606e97c278fd0b499c3ec190dad2ee9a","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 440.24 (NSPS)","page":null,"quote":"Al 2.0 1.0"}},{"id":"b2cc970fbe345d95","parameter":"Al","value":"1.0","value_num":1,"unit":"mg/L","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 440","the discharge is of the Subpart B—Aluminum Ore Subcategory","new sources (NSPS)"],"cite":{"instrument":"us_40cfr440","title":"40 CFR Part 440 — PART 440—ORE MINING AND DRESSING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=440","source_sha256":"aea3b68c1fc9aac4ea3fa56240df79cf606e97c278fd0b499c3ec190dad2ee9a","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 440.24 (NSPS)","page":null,"quote":"Al 2.0 1.0"}},{"id":"30d5147e7bdba1df","parameter":"Aluminum","value":"15.3","value_num":15.3,"unit":"mg/m (pounds per 1 million ft ) of area processed","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 465","the discharge is of the Subpart C—Aluminum Basis Material Subcategory","existing sources (BPT)","table: Subpart C"],"cite":{"instrument":"us_40cfr465","title":"40 CFR Part 465 — PART 465—COIL COATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=465","source_sha256":"817c320835fb2f9cbb5e6218efb2f5cdcb0b0527933ae87d5a3976f0981127fd","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 465.31 (BPT)","page":null,"quote":"Aluminum 15.3 (3.14) 6.26. (1.28)"}},{"id":"1a40b967dda118f2","parameter":"Aluminum","value":"4.49","value_num":4.49,"unit":"mg/m (pounds per 1 million ft ) of area processed","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 465","the discharge is of the Subpart C—Aluminum Basis Material Subcategory","existing sources (BAT)","table: Subpart C"],"cite":{"instrument":"us_40cfr465","title":"40 CFR Part 465 — PART 465—COIL COATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=465","source_sha256":"817c320835fb2f9cbb5e6218efb2f5cdcb0b0527933ae87d5a3976f0981127fd","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 465.32 (BAT)","page":null,"quote":"Aluminum 4.49 (0.92) 1.84. (0.38)"}},{"id":"44f8d0e3a0ebd5c7","parameter":"Aluminum","value":"1.44","value_num":1.44,"unit":"mg/m² (pounds per 1 million ft ) of area processed","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 465","the discharge is of the Subpart C—Aluminum Basis Material Subcategory","new sources (NSPS)","The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart.","table: Subpart C"],"cite":{"instrument":"us_40cfr465","title":"40 CFR Part 465 — PART 465—COIL COATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=465","source_sha256":"817c320835fb2f9cbb5e6218efb2f5cdcb0b0527933ae87d5a3976f0981127fd","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 465.33 (NSPS)","page":null,"quote":"Aluminum 1.44 (0.30) 0.59 (0.121)"}},{"id":"0fb6d36a965814a2","parameter":"Aluminum","value":"0.59","value_num":0.59,"unit":"mg/m² (pounds per 1 million ft ) of area processed","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 465","the discharge is of the Subpart C—Aluminum Basis Material Subcategory","new sources (NSPS)","The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart.","table: Subpart C"],"cite":{"instrument":"us_40cfr465","title":"40 CFR Part 465 — PART 465—COIL COATING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=465","source_sha256":"817c320835fb2f9cbb5e6218efb2f5cdcb0b0527933ae87d5a3976f0981127fd","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 465.33 (NSPS)","page":null,"quote":"Aluminum 1.44 (0.30) 0.59 (0.121)"}},{"id":"b83bb05193c74730","parameter":"Aluminum","value":"182.20","value_num":182.2,"unit":"mg/m² of area processed or coated","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 466","the discharge is of the Subpart A—Steel Basis Material Subcategory","existing sources (BPT)","table: Subpart A—BPT Effluent Limitations","column: Metal preparation"],"cite":{"instrument":"us_40cfr466","title":"40 CFR Part 466 — PART 466—PORCELAIN ENAMELING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=466","source_sha256":"4a4e95e44a16b28b58efce43eca3878d712f9aaf1b73e5c36c783cc12c9bc06b","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 466.11 (BPT)","page":null,"quote":"Aluminum 182.20 36.87 74.47 15.07"}},{"id":"048ddb5140e90dbe","parameter":"Aluminum","value":"36.87","value_num":36.87,"unit":"mg/m² of area processed or coated","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 466","the discharge is of the Subpart A—Steel Basis Material Subcategory","existing sources (BPT)","table: Subpart A—BPT Effluent Limitations","column: Coating operation"],"cite":{"instrument":"us_40cfr466","title":"40 CFR Part 466 — PART 466—PORCELAIN ENAMELING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=466","source_sha256":"4a4e95e44a16b28b58efce43eca3878d712f9aaf1b73e5c36c783cc12c9bc06b","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 466.11 (BPT)","page":null,"quote":"Aluminum 182.20 36.87 74.47 15.07"}},{"id":"6f80b77e8c860e4d","parameter":"Aluminum","value":"74.47","value_num":74.47,"unit":"mg/m² of area processed or coated","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 466","the discharge is of the Subpart A—Steel Basis Material Subcategory","existing sources (BPT)","table: Subpart A—BPT Effluent Limitations","column: Metal preparation"],"cite":{"instrument":"us_40cfr466","title":"40 CFR Part 466 — PART 466—PORCELAIN ENAMELING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=466","source_sha256":"4a4e95e44a16b28b58efce43eca3878d712f9aaf1b73e5c36c783cc12c9bc06b","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 466.11 (BPT)","page":null,"quote":"Aluminum 182.20 36.87 74.47 15.07"}},{"id":"77db9da7b36af6d8","parameter":"Aluminum","value":"15.07","value_num":15.07,"unit":"mg/m² of area processed or coated","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 466","the discharge is of the Subpart A—Steel Basis Material Subcategory","existing sources (BPT)","table: Subpart A—BPT Effluent Limitations","column: Coating operation"],"cite":{"instrument":"us_40cfr466","title":"40 CFR Part 466 — PART 466—PORCELAIN ENAMELING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=466","source_sha256":"4a4e95e44a16b28b58efce43eca3878d712f9aaf1b73e5c36c783cc12c9bc06b","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 466.11 (BPT)","page":null,"quote":"Aluminum 182.20 36.87 74.47 15.07"}},{"id":"6f8310976473a0d8","parameter":"Aluminum","value":"182.00","value_num":182,"unit":"mg/m² of area processed or coated","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 466","the discharge is of the Subpart A—Steel Basis Material Subcategory","existing sources (BAT)","table: Subpart A—BAT Effluent Limitations","column: Metal preparation"],"cite":{"instrument":"us_40cfr466","title":"40 CFR Part 466 — PART 466—PORCELAIN ENAMELING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=466","source_sha256":"4a4e95e44a16b28b58efce43eca3878d712f9aaf1b73e5c36c783cc12c9bc06b","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 466.12 (BAT)","page":null,"quote":"Aluminum 182.00 5.74 74.48 2.35"}},{"id":"6dca19c67e9066f7","parameter":"Aluminum","value":"5.74","value_num":5.74,"unit":"mg/m² of area processed or coated","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 466","the discharge is of the Subpart A—Steel Basis Material Subcategory","existing sources (BAT)","table: Subpart A—BAT Effluent Limitations","column: Coating operation"],"cite":{"instrument":"us_40cfr466","title":"40 CFR Part 466 — PART 466—PORCELAIN ENAMELING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=466","source_sha256":"4a4e95e44a16b28b58efce43eca3878d712f9aaf1b73e5c36c783cc12c9bc06b","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 466.12 (BAT)","page":null,"quote":"Aluminum 182.00 5.74 74.48 2.35"}},{"id":"c12a41a110869418","parameter":"Aluminum","value":"74.48","value_num":74.48,"unit":"mg/m² of area processed or coated","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 466","the discharge is of the Subpart A—Steel Basis Material Subcategory","existing sources (BAT)","table: Subpart A—BAT Effluent Limitations","column: Metal preparation"],"cite":{"instrument":"us_40cfr466","title":"40 CFR Part 466 — PART 466—PORCELAIN ENAMELING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=466","source_sha256":"4a4e95e44a16b28b58efce43eca3878d712f9aaf1b73e5c36c783cc12c9bc06b","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 466.12 (BAT)","page":null,"quote":"Aluminum 182.00 5.74 74.48 2.35"}},{"id":"f441d2aa63593d5f","parameter":"Aluminum","value":"2.35","value_num":2.35,"unit":"mg/m² of area processed or coated","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 466","the discharge is of the Subpart A—Steel Basis Material Subcategory","existing sources (BAT)","table: Subpart A—BAT Effluent Limitations","column: Coating operation"],"cite":{"instrument":"us_40cfr466","title":"40 CFR Part 466 — PART 466—PORCELAIN ENAMELING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=466","source_sha256":"4a4e95e44a16b28b58efce43eca3878d712f9aaf1b73e5c36c783cc12c9bc06b","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 466.12 (BAT)","page":null,"quote":"Aluminum 182.00 5.74 74.48 2.35"}},{"id":"6df557c46b3819a5","parameter":"Aluminum","value":"30.3","value_num":30.3,"unit":"mg/m² of area processed or coated","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 466","the discharge is of the Subpart A—Steel Basis Material Subcategory","new sources (NSPS)","Any new source subject to this subpart must achieve the following new source performance standards:","table: Subpart A—NSPS","column: Metal preparation"],"cite":{"instrument":"us_40cfr466","title":"40 CFR Part 466 — PART 466—PORCELAIN ENAMELING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=466","source_sha256":"4a4e95e44a16b28b58efce43eca3878d712f9aaf1b73e5c36c783cc12c9bc06b","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 466.13 (NSPS)","page":null,"quote":"Aluminum 30.3 3.82 12.4 1.56"}},{"id":"dafa5a452f2a552f","parameter":"Aluminum","value":"3.82","value_num":3.82,"unit":"mg/m² of area processed or coated","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 466","the discharge is of the Subpart A—Steel Basis Material Subcategory","new sources (NSPS)","Any new source subject to this subpart must achieve the following new source performance standards:","table: Subpart A—NSPS","column: Coating operation"],"cite":{"instrument":"us_40cfr466","title":"40 CFR Part 466 — PART 466—PORCELAIN ENAMELING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=466","source_sha256":"4a4e95e44a16b28b58efce43eca3878d712f9aaf1b73e5c36c783cc12c9bc06b","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 466.13 (NSPS)","page":null,"quote":"Aluminum 30.3 3.82 12.4 1.56"}},{"id":"c34928850ac7ebf1","parameter":"Aluminum","value":"12.4","value_num":12.4,"unit":"mg/m² of area processed or coated","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 466","the discharge is of the Subpart A—Steel Basis Material Subcategory","new sources (NSPS)","Any new source subject to this subpart must achieve the following new source performance standards:","table: Subpart A—NSPS","column: Metal preparation"],"cite":{"instrument":"us_40cfr466","title":"40 CFR Part 466 — PART 466—PORCELAIN ENAMELING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=466","source_sha256":"4a4e95e44a16b28b58efce43eca3878d712f9aaf1b73e5c36c783cc12c9bc06b","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 466.13 (NSPS)","page":null,"quote":"Aluminum 30.3 3.82 12.4 1.56"}},{"id":"d0a9eacc284b26cd","parameter":"Aluminum","value":"1.56","value_num":1.56,"unit":"mg/m² of area processed or coated","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 466","the discharge is of the Subpart A—Steel Basis Material Subcategory","new sources (NSPS)","Any new source subject to this subpart must achieve the following new source performance standards:","table: Subpart A—NSPS","column: Coating operation"],"cite":{"instrument":"us_40cfr466","title":"40 CFR Part 466 — PART 466—PORCELAIN ENAMELING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=466","source_sha256":"4a4e95e44a16b28b58efce43eca3878d712f9aaf1b73e5c36c783cc12c9bc06b","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 466.13 (NSPS)","page":null,"quote":"Aluminum 30.3 3.82 12.4 1.56"}},{"id":"b095143530df165e","parameter":"Aluminum","value":"3.16","value_num":3.16,"unit":"Mg/m² (pounds per/1million ft ) of Area Coated","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 466","the discharge is of the Subpart B—Cast Iron Basis Material Subcategory","existing sources (BPT)","(b) The discharge of process wasterwater pollutants from all porcelain enameling coating operations shall not exceed the values set forth below:","table: Subpart B—BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr466","title":"40 CFR Part 466 — PART 466—PORCELAIN ENAMELING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=466","source_sha256":"4a4e95e44a16b28b58efce43eca3878d712f9aaf1b73e5c36c783cc12c9bc06b","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 466.21 (BPT)","page":null,"quote":"Aluminum 3.16 (0.65) 1.29 (0.27)"}},{"id":"022c77580857b0a5","parameter":"Aluminum","value":"1.29","value_num":1.29,"unit":"Mg/m² (pounds per/1million ft ) of Area Coated","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 466","the discharge is of the Subpart B—Cast Iron Basis Material Subcategory","existing sources (BPT)","(b) The discharge of process wasterwater pollutants from all porcelain enameling coating operations shall not exceed the values set forth below:","table: Subpart B—BPT Effluent Limitations"],"cite":{"instrument":"us_40cfr466","title":"40 CFR Part 466 — PART 466—PORCELAIN ENAMELING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=466","source_sha256":"4a4e95e44a16b28b58efce43eca3878d712f9aaf1b73e5c36c783cc12c9bc06b","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 466.21 (BPT)","page":null,"quote":"Aluminum 3.16 (0.65) 1.29 (0.27)"}},{"id":"7a56349dcde5d362","parameter":"Aluminum","value":"5.74","value_num":5.74,"unit":"Mg/m² (pounds per/million ft²) of area coated","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 466","the discharge is of the Subpart B—Cast Iron Basis Material Subcategory","existing sources (BAT)","(b) The discharge of process wastewater pollutants from all porcelain enameling coating operations shall not exceed the values set forth below:","table: Subpart B—BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr466","title":"40 CFR Part 466 — PART 466—PORCELAIN ENAMELING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=466","source_sha256":"4a4e95e44a16b28b58efce43eca3878d712f9aaf1b73e5c36c783cc12c9bc06b","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 466.22 (BAT)","page":null,"quote":"Aluminum 5.74 (1.18) 2.35 (0.48)"}},{"id":"03a4ffd1e214a821","parameter":"Aluminum","value":"2.35","value_num":2.35,"unit":"Mg/m² (pounds per/million ft²) of area coated","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 466","the discharge is of the Subpart B—Cast Iron Basis Material Subcategory","existing sources (BAT)","(b) The discharge of process wastewater pollutants from all porcelain enameling coating operations shall not exceed the values set forth below:","table: Subpart B—BAT Effluent Limitations"],"cite":{"instrument":"us_40cfr466","title":"40 CFR Part 466 — PART 466—PORCELAIN ENAMELING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=466","source_sha256":"4a4e95e44a16b28b58efce43eca3878d712f9aaf1b73e5c36c783cc12c9bc06b","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 466.22 (BAT)","page":null,"quote":"Aluminum 5.74 (1.18) 2.35 (0.48)"}},{"id":"2a365e432f00c9e1","parameter":"Aluminum","value":"3.82","value_num":3.82,"unit":"Mg/m² (pounds per million ft²) of area coated","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 466","the discharge is of the Subpart B—Cast Iron Basis Material Subcategory","new sources (NSPS)","(b) The discharge of process wastewater pollutants from all porcelain enameling coating operations shall not exceed the values set forth below:","table: Subpart B—NSPS"],"cite":{"instrument":"us_40cfr466","title":"40 CFR Part 466 — PART 466—PORCELAIN ENAMELING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=466","source_sha256":"4a4e95e44a16b28b58efce43eca3878d712f9aaf1b73e5c36c783cc12c9bc06b","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 466.23 (NSPS)","page":null,"quote":"Aluminum 3.82 (0.78) 1.56 (0.32)"}},{"id":"abacdf8acfaba048","parameter":"Aluminum","value":"1.56","value_num":1.56,"unit":"Mg/m² (pounds per million ft²) of area coated","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 466","the discharge is of the Subpart B—Cast Iron Basis Material Subcategory","new sources (NSPS)","(b) The discharge of process wastewater pollutants from all porcelain enameling coating operations shall not exceed the values set forth below:","table: Subpart B—NSPS"],"cite":{"instrument":"us_40cfr466","title":"40 CFR Part 466 — PART 466—PORCELAIN ENAMELING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=466","source_sha256":"4a4e95e44a16b28b58efce43eca3878d712f9aaf1b73e5c36c783cc12c9bc06b","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 466.23 (NSPS)","page":null,"quote":"Aluminum 3.82 (0.78) 1.56 (0.32)"}},{"id":"91b66c5cac926f06","parameter":"Aluminum","value":"176.98","value_num":176.98,"unit":"mg/m² of area processed or coated","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 466","the discharge is of the Subpart C—Aluminum Basis Material Subcategory","existing sources (BPT)","table: Subpart C—BPT Effluent Limitations","column: Metal preparation"],"cite":{"instrument":"us_40cfr466","title":"40 CFR Part 466 — PART 466—PORCELAIN ENAMELING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=466","source_sha256":"4a4e95e44a16b28b58efce43eca3878d712f9aaf1b73e5c36c783cc12c9bc06b","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 466.31 (BPT)","page":null,"quote":"Aluminum 176.98 68.44 72.35 27.98"}},{"id":"a6359e1da8b25f3b","parameter":"Aluminum","value":"68.44","value_num":68.44,"unit":"mg/m² of area processed or coated","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 466","the discharge is of the Subpart C—Aluminum Basis Material Subcategory","existing sources (BPT)","table: Subpart C—BPT Effluent Limitations","column: Coating operation"],"cite":{"instrument":"us_40cfr466","title":"40 CFR Part 466 — PART 466—PORCELAIN ENAMELING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=466","source_sha256":"4a4e95e44a16b28b58efce43eca3878d712f9aaf1b73e5c36c783cc12c9bc06b","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 466.31 (BPT)","page":null,"quote":"Aluminum 176.98 68.44 72.35 27.98"}},{"id":"705715f96a4e7f15","parameter":"Aluminum","value":"72.35","value_num":72.35,"unit":"mg/m² of area processed or coated","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 466","the discharge is of the Subpart C—Aluminum Basis Material Subcategory","existing sources (BPT)","table: Subpart C—BPT Effluent Limitations","column: Metal preparation"],"cite":{"instrument":"us_40cfr466","title":"40 CFR Part 466 — PART 466—PORCELAIN ENAMELING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=466","source_sha256":"4a4e95e44a16b28b58efce43eca3878d712f9aaf1b73e5c36c783cc12c9bc06b","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 466.31 (BPT)","page":null,"quote":"Aluminum 176.98 68.44 72.35 27.98"}},{"id":"5a3f7dc950ec09d6","parameter":"Aluminum","value":"27.98","value_num":27.98,"unit":"mg/m² of area processed or coated","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 466","the discharge is of the Subpart C—Aluminum Basis Material Subcategory","existing sources (BPT)","table: Subpart C—BPT Effluent Limitations","column: Coating operation"],"cite":{"instrument":"us_40cfr466","title":"40 CFR Part 466 — PART 466—PORCELAIN ENAMELING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=466","source_sha256":"4a4e95e44a16b28b58efce43eca3878d712f9aaf1b73e5c36c783cc12c9bc06b","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 466.31 (BPT)","page":null,"quote":"Aluminum 176.98 68.44 72.35 27.98"}},{"id":"0610884f0dde197b","parameter":"Aluminum","value":"176.98","value_num":176.98,"unit":"mg/m² of area processed or coated","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 466","the discharge is of the Subpart C—Aluminum Basis Material Subcategory","existing sources (BAT)","table: Subpart C—BAT Effluent Limitations","column: Metal preparation"],"cite":{"instrument":"us_40cfr466","title":"40 CFR Part 466 — PART 466—PORCELAIN ENAMELING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=466","source_sha256":"4a4e95e44a16b28b58efce43eca3878d712f9aaf1b73e5c36c783cc12c9bc06b","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 466.32 (BAT)","page":null,"quote":"Aluminum 176.98 5.74 72.35 2.35"}},{"id":"841c31f9c24a68bc","parameter":"Aluminum","value":"5.74","value_num":5.74,"unit":"mg/m² of area processed or coated","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 466","the discharge is of the Subpart C—Aluminum Basis Material Subcategory","existing sources (BAT)","table: Subpart C—BAT Effluent Limitations","column: Coating operation"],"cite":{"instrument":"us_40cfr466","title":"40 CFR Part 466 — PART 466—PORCELAIN ENAMELING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=466","source_sha256":"4a4e95e44a16b28b58efce43eca3878d712f9aaf1b73e5c36c783cc12c9bc06b","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 466.32 (BAT)","page":null,"quote":"Aluminum 176.98 5.74 72.35 2.35"}},{"id":"56dcb0e1d56731fd","parameter":"Aluminum","value":"72.35","value_num":72.35,"unit":"mg/m² of area processed or coated","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 466","the discharge is of the Subpart C—Aluminum Basis Material Subcategory","existing sources (BAT)","table: Subpart C—BAT Effluent Limitations","column: Metal preparation"],"cite":{"instrument":"us_40cfr466","title":"40 CFR Part 466 — PART 466—PORCELAIN ENAMELING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=466","source_sha256":"4a4e95e44a16b28b58efce43eca3878d712f9aaf1b73e5c36c783cc12c9bc06b","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 466.32 (BAT)","page":null,"quote":"Aluminum 176.98 5.74 72.35 2.35"}},{"id":"2e0ffc597bf57a6f","parameter":"Aluminum","value":"2.35","value_num":2.35,"unit":"mg/m² of area processed or coated","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 466","the discharge is of the Subpart C—Aluminum Basis Material Subcategory","existing sources (BAT)","table: Subpart C—BAT Effluent Limitations","column: Coating operation"],"cite":{"instrument":"us_40cfr466","title":"40 CFR Part 466 — PART 466—PORCELAIN ENAMELING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=466","source_sha256":"4a4e95e44a16b28b58efce43eca3878d712f9aaf1b73e5c36c783cc12c9bc06b","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 466.32 (BAT)","page":null,"quote":"Aluminum 176.98 5.74 72.35 2.35"}},{"id":"5d26ff822b350fd8","parameter":"Aluminum","value":"29.46","value_num":29.46,"unit":"mg/m² of area processed or coated","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 466","the discharge is of the Subpart C—Aluminum Basis Material Subcategory","new sources (NSPS)","Any new source subject to this subpart must achieve the following new source performance standards:","table: Subpart C—NSPS","column: Metal preparation"],"cite":{"instrument":"us_40cfr466","title":"40 CFR Part 466 — PART 466—PORCELAIN ENAMELING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=466","source_sha256":"4a4e95e44a16b28b58efce43eca3878d712f9aaf1b73e5c36c783cc12c9bc06b","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 466.33 (NSPS)","page":null,"quote":"Aluminum 29.46 3.82 12.06 1.56"}},{"id":"e5307b40fca78aa7","parameter":"Aluminum","value":"3.82","value_num":3.82,"unit":"mg/m² of area processed or coated","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 466","the discharge is of the Subpart C—Aluminum Basis Material Subcategory","new sources (NSPS)","Any new source subject to this subpart must achieve the following new source performance standards:","table: Subpart C—NSPS","column: Coating operation"],"cite":{"instrument":"us_40cfr466","title":"40 CFR Part 466 — PART 466—PORCELAIN ENAMELING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=466","source_sha256":"4a4e95e44a16b28b58efce43eca3878d712f9aaf1b73e5c36c783cc12c9bc06b","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 466.33 (NSPS)","page":null,"quote":"Aluminum 29.46 3.82 12.06 1.56"}},{"id":"b41e13b6f85ca7f1","parameter":"Aluminum","value":"12.06","value_num":12.06,"unit":"mg/m² of area processed or coated","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 466","the discharge is of the Subpart C—Aluminum Basis Material Subcategory","new sources (NSPS)","Any new source subject to this subpart must achieve the following new source performance standards:","table: Subpart C—NSPS","column: Metal preparation"],"cite":{"instrument":"us_40cfr466","title":"40 CFR Part 466 — PART 466—PORCELAIN ENAMELING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=466","source_sha256":"4a4e95e44a16b28b58efce43eca3878d712f9aaf1b73e5c36c783cc12c9bc06b","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 466.33 (NSPS)","page":null,"quote":"Aluminum 29.46 3.82 12.06 1.56"}},{"id":"0b6c74265c0f4536","parameter":"Aluminum","value":"1.56","value_num":1.56,"unit":"mg/m² of area processed or coated","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 466","the discharge is of the Subpart C—Aluminum Basis Material Subcategory","new sources (NSPS)","Any new source subject to this subpart must achieve the following new source performance standards:","table: Subpart C—NSPS","column: Coating operation"],"cite":{"instrument":"us_40cfr466","title":"40 CFR Part 466 — PART 466—PORCELAIN ENAMELING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=466","source_sha256":"4a4e95e44a16b28b58efce43eca3878d712f9aaf1b73e5c36c783cc12c9bc06b","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 466.33 (NSPS)","page":null,"quote":"Aluminum 29.46 3.82 12.06 1.56"}},{"id":"efc3c3a7e1f9a2de","parameter":"Aluminum","value":"50.97","value_num":50.97,"unit":"mg/m² of area processed or coated","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 466","the discharge is of the Subpart D—Copper Basis Material Subcategory","new sources (NSPS)","Any new source subject to this subpart must achieve the following new source performance standards:","table: Subpart D—NSPS","column: Metal preparation"],"cite":{"instrument":"us_40cfr466","title":"40 CFR Part 466 — PART 466—PORCELAIN ENAMELING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=466","source_sha256":"4a4e95e44a16b28b58efce43eca3878d712f9aaf1b73e5c36c783cc12c9bc06b","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 466.43 (NSPS)","page":null,"quote":"Aluminum 50.97 3.82 20.86 1.56"}},{"id":"62bb9df6a699b30e","parameter":"Aluminum","value":"3.82","value_num":3.82,"unit":"mg/m² of area processed or coated","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 466","the discharge is of the Subpart D—Copper Basis Material Subcategory","new sources (NSPS)","Any new source subject to this subpart must achieve the following new source performance standards:","table: Subpart D—NSPS","column: Coating operation"],"cite":{"instrument":"us_40cfr466","title":"40 CFR Part 466 — PART 466—PORCELAIN ENAMELING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=466","source_sha256":"4a4e95e44a16b28b58efce43eca3878d712f9aaf1b73e5c36c783cc12c9bc06b","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 466.43 (NSPS)","page":null,"quote":"Aluminum 50.97 3.82 20.86 1.56"}},{"id":"e1670fbc3139ffcc","parameter":"Aluminum","value":"20.86","value_num":20.86,"unit":"mg/m² of area processed or coated","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 466","the discharge is of the Subpart D—Copper Basis Material Subcategory","new sources (NSPS)","Any new source subject to this subpart must achieve the following new source performance standards:","table: Subpart D—NSPS","column: Metal preparation"],"cite":{"instrument":"us_40cfr466","title":"40 CFR Part 466 — PART 466—PORCELAIN ENAMELING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=466","source_sha256":"4a4e95e44a16b28b58efce43eca3878d712f9aaf1b73e5c36c783cc12c9bc06b","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 466.43 (NSPS)","page":null,"quote":"Aluminum 50.97 3.82 20.86 1.56"}},{"id":"6db3e3923cb993ef","parameter":"Aluminum","value":"1.56","value_num":1.56,"unit":"mg/m² of area processed or coated","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 466","the discharge is of the Subpart D—Copper Basis Material Subcategory","new sources (NSPS)","Any new source subject to this subpart must achieve the following new source performance standards:","table: Subpart D—NSPS","column: Coating operation"],"cite":{"instrument":"us_40cfr466","title":"40 CFR Part 466 — PART 466—PORCELAIN ENAMELING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=466","source_sha256":"4a4e95e44a16b28b58efce43eca3878d712f9aaf1b73e5c36c783cc12c9bc06b","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 466.43 (NSPS)","page":null,"quote":"Aluminum 50.97 3.82 20.86 1.56"}},{"id":"f4884fb702961331","parameter":"Aluminum","value":"0.525","value_num":0.525,"unit":"mg/off-kg (lb/million off-lbs) of aluminum rolled with neat oils","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.12 (BPT)","page":null,"quote":"Aluminum 0.525 0.257"}},{"id":"8b9030e102de5092","parameter":"Aluminum","value":"0.257","value_num":0.257,"unit":"mg/off-kg (lb/million off-lbs) of aluminum rolled with neat oils","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.12 (BPT)","page":null,"quote":"Aluminum 0.525 0.257"}},{"id":"971d6d6d60ca6f1a","parameter":"Aluminum","value":"0.356","value_num":0.356,"unit":"mg/off-kg (lb/million off-lbs) of aluminum rolled with neat oils","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.12 (BPT)","page":null,"quote":"Aluminum 0.356 0.174"}},{"id":"86d789548abf2b6c","parameter":"Aluminum","value":"0.174","value_num":0.174,"unit":"mg/off-kg (lb/million off-lbs) of aluminum rolled with neat oils","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.12 (BPT)","page":null,"quote":"Aluminum 0.356 0.174"}},{"id":"0ac47e225abf3064","parameter":"Aluminum","value":"0.0127","value_num":0.0127,"unit":"mg/off-kg (lb/million off-lbs) of aluminum sheet cast by continuous methods","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.12 (BPT)","page":null,"quote":"Aluminum 0.0127 0.0063"}},{"id":"52c8ff813306fba2","parameter":"Aluminum","value":"0.0063","value_num":0.0063,"unit":"mg/off-kg (lb/million off-lbs) of aluminum sheet cast by continuous methods","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.12 (BPT)","page":null,"quote":"Aluminum 0.0127 0.0063"}},{"id":"fa64cc057c85cbdb","parameter":"Aluminum","value":"49.55","value_num":49.55,"unit":"mg/off-kg (lb/million off-lbs) of aluminum quenched","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.12 (BPT)","page":null,"quote":"Aluminum 49.55 24.66"}},{"id":"0d02079581a4a49c","parameter":"Aluminum","value":"24.66","value_num":24.66,"unit":"mg/off-kg (lb/million off-lbs) of aluminum quenched","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.12 (BPT)","page":null,"quote":"Aluminum 49.55 24.66"}},{"id":"82d3d7f3084654bb","parameter":"Aluminum","value":"1.15","value_num":1.15,"unit":"mg/off-kg (lb/million off-lbs) of aluminum cleaned or etched","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.12 (BPT)","page":null,"quote":"Aluminum 1.15 0.573"}},{"id":"657b79aa698c24c4","parameter":"Aluminum","value":"0.573","value_num":0.573,"unit":"mg/off-kg (lb/million off-lbs) of aluminum cleaned or etched","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.12 (BPT)","page":null,"quote":"Aluminum 1.15 0.573"}},{"id":"a831f0db6009713c","parameter":"Aluminum","value":"89.46","value_num":89.46,"unit":"mg/off-kg (lb/million off-lbs) of aluminum cleaned or etched","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.12 (BPT)","page":null,"quote":"Aluminum 89.46 44.52"}},{"id":"aa9d541cb7c418f1","parameter":"Aluminum","value":"44.52","value_num":44.52,"unit":"mg/off-kg (lb/million off-lbs) of aluminum cleaned or etched","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.12 (BPT)","page":null,"quote":"Aluminum 89.46 44.52"}},{"id":"493869a6cff9486a","parameter":"Aluminum","value":"102.24","value_num":102.24,"unit":"mg/off-kg (lb/million off-lbs) of aluminum cleaned or etched","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.12 (BPT)","page":null,"quote":"Aluminum 102.24 50.88"}},{"id":"8085942a9d8cffca","parameter":"Aluminum","value":"50.88","value_num":50.88,"unit":"mg/off-kg (lb/million off-lbs) of aluminum cleaned or etched","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.12 (BPT)","page":null,"quote":"Aluminum 102.24 50.88"}},{"id":"5b0d1db846965fff","parameter":"Aluminum","value":"0.525","value_num":0.525,"unit":"mg/off-kg (lb/million off-lbs) of aluminum rolled with neat oils","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","existing sources (BAT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.13 (BAT)","page":null,"quote":"Aluminum 0.525 0.257"}},{"id":"488c9507cf420464","parameter":"Aluminum","value":"0.257","value_num":0.257,"unit":"mg/off-kg (lb/million off-lbs) of aluminum rolled with neat oils","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","existing sources (BAT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.13 (BAT)","page":null,"quote":"Aluminum 0.525 0.257"}},{"id":"7863be293a9e3a08","parameter":"Aluminum","value":"0.356","value_num":0.356,"unit":"mg/off-kg (lb/million off-lbs) of aluminum rolled with neat oils","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","existing sources (BAT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.13 (BAT)","page":null,"quote":"Aluminum 0.356 0.174"}},{"id":"c7be65359e9f3ec9","parameter":"Aluminum","value":"0.174","value_num":0.174,"unit":"mg/off-kg (lb/million off-lbs) of aluminum rolled with neat oils","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","existing sources (BAT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.13 (BAT)","page":null,"quote":"Aluminum 0.356 0.174"}},{"id":"2fb80967081b91bf","parameter":"Aluminum","value":"0.0127","value_num":0.0127,"unit":"mg/off-kg (lb/million off-lbs) of aluminum sheet cast","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","existing sources (BAT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.13 (BAT)","page":null,"quote":"Aluminum 0.0127 0.0062"}},{"id":"7ad70d985979069a","parameter":"Aluminum","value":"0.0062","value_num":0.0062,"unit":"mg/off-kg (lb/million off-lbs) of aluminum sheet cast","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","existing sources (BAT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.13 (BAT)","page":null,"quote":"Aluminum 0.0127 0.0062"}},{"id":"f69ac0c392f5b1a3","parameter":"Aluminum","value":"13.10","value_num":13.1,"unit":"mg/off-kg (lb/million off-lbs) of aluminum quenched","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","existing sources (BAT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.13 (BAT)","page":null,"quote":"Aluminum 13.10 6.518"}},{"id":"f019f6d8886bfd68","parameter":"Aluminum","value":"6.518","value_num":6.518,"unit":"mg/off-kg (lb/million off-lbs) of aluminum quenched","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","existing sources (BAT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.13 (BAT)","page":null,"quote":"Aluminum 13.10 6.518"}},{"id":"236361d5390c4990","parameter":"Aluminum","value":"1.151","value_num":1.151,"unit":"mg/off-kg (lb/million off-lbs) of aluminum cleaned or etched","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","existing sources (BAT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.13 (BAT)","page":null,"quote":"Aluminum 1.151 0.573"}},{"id":"e203a8cc5fcccb15","parameter":"Aluminum","value":"0.573","value_num":0.573,"unit":"mg/off-kg (lb/million off-lbs) of aluminum cleaned or etched","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","existing sources (BAT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.13 (BAT)","page":null,"quote":"Aluminum 1.151 0.573"}},{"id":"c80da21419bbd641","parameter":"Aluminum","value":"8.944","value_num":8.944,"unit":"mg/off-kg (lb/million off-lbs) of aluminum cleaned or etched","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","existing sources (BAT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.13 (BAT)","page":null,"quote":"Aluminum 8.944 4.45"}},{"id":"feab0b22ae9d0ebf","parameter":"Aluminum","value":"4.45","value_num":4.45,"unit":"mg/off-kg (lb/million off-lbs) of aluminum cleaned or etched","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","existing sources (BAT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.13 (BAT)","page":null,"quote":"Aluminum 8.944 4.45"}},{"id":"069799a1a2833b12","parameter":"Aluminum","value":"12.43","value_num":12.43,"unit":"mg/off-kg (lb/million off-lbs) of aluminum cleaned or etched","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","existing sources (BAT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.13 (BAT)","page":null,"quote":"Aluminum 12.43 6.186"}},{"id":"c1a74f41b7175c03","parameter":"Aluminum","value":"6.186","value_num":6.186,"unit":"mg/off-kg (lb/million off-lbs) of aluminum cleaned or etched","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","existing sources (BAT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.13 (BAT)","page":null,"quote":"Aluminum 12.43 6.186"}},{"id":"bdd606e0356fbcbe","parameter":"Aluminum","value":"0.499","value_num":0.499,"unit":"mg/off-kg (lb/million off-lbs) of aluminum rolled with neat oils","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","new sources (NSPS)","Any new source subject to this subpart must achieve the following performance standards. The mass of pollutants in the core and ancillary operations' process wastewater shall not exceed the following values:"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.14 (NSPS)","page":null,"quote":"Aluminum 0.499 0.221"}},{"id":"ad00f5e000e1b941","parameter":"Aluminum","value":"0.221","value_num":0.221,"unit":"mg/off-kg (lb/million off-lbs) of aluminum rolled with neat oils","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","new sources (NSPS)","Any new source subject to this subpart must achieve the following performance standards. The mass of pollutants in the core and ancillary operations' process wastewater shall not exceed the following values:"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.14 (NSPS)","page":null,"quote":"Aluminum 0.499 0.221"}},{"id":"ff5f277977d7dbe2","parameter":"Aluminum","value":"0.338","value_num":0.338,"unit":"mg/off-kg (lb/million off-lbs) of aluminum rolled with neat oils","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","new sources (NSPS)","Any new source subject to this subpart must achieve the following performance standards. The mass of pollutants in the core and ancillary operations' process wastewater shall not exceed the following values:"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.14 (NSPS)","page":null,"quote":"Aluminum 0.338 0.150"}},{"id":"5959d1de275284e3","parameter":"Aluminum","value":"0.150","value_num":0.15,"unit":"mg/off-kg (lb/million off-lbs) of aluminum rolled with neat oils","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","new sources (NSPS)","Any new source subject to this subpart must achieve the following performance standards. The mass of pollutants in the core and ancillary operations' process wastewater shall not exceed the following values:"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.14 (NSPS)","page":null,"quote":"Aluminum 0.338 0.150"}},{"id":"2ee7c2d7b9a49712","parameter":"Aluminum","value":"0.012","value_num":0.012,"unit":"mg/off-kg (lb/million off-lbs) of aluminum cast","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","new sources (NSPS)","Any new source subject to this subpart must achieve the following performance standards. The mass of pollutants in the core and ancillary operations' process wastewater shall not exceed the following values:"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.14 (NSPS)","page":null,"quote":"Aluminum 0.012 0.0053"}},{"id":"c04e5ff3b0f0c3c0","parameter":"Aluminum","value":"0.0053","value_num":0.0053,"unit":"mg/off-kg (lb/million off-lbs) of aluminum cast","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","new sources (NSPS)","Any new source subject to this subpart must achieve the following performance standards. The mass of pollutants in the core and ancillary operations' process wastewater shall not exceed the following values:"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.14 (NSPS)","page":null,"quote":"Aluminum 0.012 0.0053"}},{"id":"34892bd3ff5cfe47","parameter":"Aluminum","value":"12.45","value_num":12.45,"unit":"mg/off-kg (lb/million off-lbs) of aluminum quenched","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","new sources (NSPS)","Any new source subject to this subpart must achieve the following performance standards. The mass of pollutants in the core and ancillary operations' process wastewater shall not exceed the following values:"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.14 (NSPS)","page":null,"quote":"Aluminum 12.45 5.52"}},{"id":"e310d738a0dfb9ae","parameter":"Aluminum","value":"5.52","value_num":5.52,"unit":"mg/off-kg (lb/million off-lbs) of aluminum quenched","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","new sources (NSPS)","Any new source subject to this subpart must achieve the following performance standards. The mass of pollutants in the core and ancillary operations' process wastewater shall not exceed the following values:"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.14 (NSPS)","page":null,"quote":"Aluminum 12.45 5.52"}},{"id":"b4abf7f9d738d60a","parameter":"Aluminum","value":"1.094","value_num":1.094,"unit":"mg/off-kg (lb/million off-lbs) of aluminum cleaned or etched","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","new sources (NSPS)","Any new source subject to this subpart must achieve the following performance standards. The mass of pollutants in the core and ancillary operations' process wastewater shall not exceed the following values:"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.14 (NSPS)","page":null,"quote":"Aluminum 1.094 0.485"}},{"id":"da2bfee85215e0fa","parameter":"Aluminum","value":"0.485","value_num":0.485,"unit":"mg/off-kg (lb/million off-lbs) of aluminum cleaned or etched","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","new sources (NSPS)","Any new source subject to this subpart must achieve the following performance standards. The mass of pollutants in the core and ancillary operations' process wastewater shall not exceed the following values:"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.14 (NSPS)","page":null,"quote":"Aluminum 1.094 0.485"}},{"id":"3896bb0014e55ba0","parameter":"Aluminum","value":"8.50","value_num":8.5,"unit":"mg/off-kg (lb/million off-lbs) of aluminum cleaned or etched","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","new sources (NSPS)","Any new source subject to this subpart must achieve the following performance standards. The mass of pollutants in the core and ancillary operations' process wastewater shall not exceed the following values:"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.14 (NSPS)","page":null,"quote":"Aluminum 8.50 3.70"}},{"id":"a31eda1c74a775a6","parameter":"Aluminum","value":"3.70","value_num":3.7,"unit":"mg/off-kg (lb/million off-lbs) of aluminum cleaned or etched","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","new sources (NSPS)","Any new source subject to this subpart must achieve the following performance standards. The mass of pollutants in the core and ancillary operations' process wastewater shall not exceed the following values:"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.14 (NSPS)","page":null,"quote":"Aluminum 8.50 3.70"}},{"id":"ba9c50ee3e23115f","parameter":"Aluminum","value":"11.81","value_num":11.81,"unit":"mg/off-kg (lb/million off-lbs) of aluminum cleaned or etched","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","new sources (NSPS)","Any new source subject to this subpart must achieve the following performance standards. The mass of pollutants in the core and ancillary operations' process wastewater shall not exceed the following values:"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.14 (NSPS)","page":null,"quote":"Aluminum 11.81 5.24"}},{"id":"9137c679e333f3c9","parameter":"Aluminum","value":"5.24","value_num":5.24,"unit":"mg/off-kg (lb/million off-lbs) of aluminum cleaned or etched","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart A—Rolling With Neat Oils Subcategory","new sources (NSPS)","Any new source subject to this subpart must achieve the following performance standards. The mass of pollutants in the core and ancillary operations' process wastewater shall not exceed the following values:"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.14 (NSPS)","page":null,"quote":"Aluminum 11.81 5.24"}},{"id":"b18d39f1a26d7d15","parameter":"Aluminum","value":"0.84","value_num":0.84,"unit":"mg/off-kg (lb/million off-lbs) of aluminum rolled with emulsions","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart B—Rolling With Emulsions Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.22 (BPT)","page":null,"quote":"Aluminum 0.84 0.416"}},{"id":"132680e179ddff19","parameter":"Aluminum","value":"0.416","value_num":0.416,"unit":"mg/off-kg (lb/million off-lbs) of aluminum rolled with emulsions","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart B—Rolling With Emulsions Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.22 (BPT)","page":null,"quote":"Aluminum 0.84 0.416"}},{"id":"ba5a25366b66f20a","parameter":"Aluminum","value":"8.55","value_num":8.55,"unit":"mg/off-kg (lb/million off-lbs) of aluminum cast","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart B—Rolling With Emulsions Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.22 (BPT)","page":null,"quote":"Aluminum 8.55 4.26"}},{"id":"48ac9abefb0766c5","parameter":"Aluminum","value":"4.26","value_num":4.26,"unit":"mg/off-kg (lb/million off-lbs) of aluminum cast","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart B—Rolling With Emulsions Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.22 (BPT)","page":null,"quote":"Aluminum 8.55 4.26"}},{"id":"dfe693321145f633","parameter":"Aluminum","value":"49.55","value_num":49.55,"unit":"mg/off-kg (lb/million off-lbs) of aluminum quenched","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart B—Rolling With Emulsions Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.22 (BPT)","page":null,"quote":"Aluminum 49.55 24.66"}},{"id":"08d3696fd875456d","parameter":"Aluminum","value":"24.66","value_num":24.66,"unit":"mg/off-kg (lb/million off-lbs) of aluminum quenched","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart B—Rolling With Emulsions Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.22 (BPT)","page":null,"quote":"Aluminum 49.55 24.66"}},{"id":"6c646d0c3ea71e53","parameter":"Aluminum","value":"1.15","value_num":1.15,"unit":"mg/off-kg (lb/million off-lbs) of aluminum cleaned or etched","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart B—Rolling With Emulsions Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.22 (BPT)","page":null,"quote":"Aluminum 1.15 0.573"}},{"id":"0db5dd6c150e2f33","parameter":"Aluminum","value":"0.573","value_num":0.573,"unit":"mg/off-kg (lb/million off-lbs) of aluminum cleaned or etched","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart B—Rolling With Emulsions Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.22 (BPT)","page":null,"quote":"Aluminum 1.15 0.573"}},{"id":"a414f32c06b8c220","parameter":"Aluminum","value":"89.46","value_num":89.46,"unit":"mg/off-kg (lb/million off-lbs) of aluminum cleaned or etched","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart B—Rolling With Emulsions Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.22 (BPT)","page":null,"quote":"Aluminum 89.46 44.52"}},{"id":"16168505192d22a0","parameter":"Aluminum","value":"44.52","value_num":44.52,"unit":"mg/off-kg (lb/million off-lbs) of aluminum cleaned or etched","statistic":"monthly_avg","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart B—Rolling With Emulsions Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.22 (BPT)","page":null,"quote":"Aluminum 89.46 44.52"}},{"id":"fdcef523cde1f2c4","parameter":"Aluminum","value":"102.24","value_num":102.24,"unit":"mg/off-kg (lb/million off-lbs) of aluminum cleaned or etched","statistic":"daily_max","direction":"max","kind":"limit","medium":"water_discharge","level":"national","route":"direct","parameter_key":"cas:7429-90-5","place":["US"],"conditions":["route is direct","cites is 40 CFR 467","the discharge is of the Subpart B—Rolling With Emulsions Subcategory","existing sources (BPT)"],"cite":{"instrument":"us_40cfr467","title":"40 CFR Part 467 — PART 467—ALUMINUM FORMING POINT SOURCE CATEGORY","issuer":"U.S. Environmental Protection Agency","edition":"eCFR as of 2026-10-05","source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-10-05/title-40.xml?part=467","source_sha256":"4b59a142f54a91aef8356c2f3c507cc96e171e01344aa388d2f55e6832ed2925","fetched_at":"2026-10-09","source_status":{"checked":"2026-11-28","status":"unchanged"},"section":"40 CFR 467.22 (BPT)","page":null,"quote":"Aluminum 102.24 50.88"}}],"next":[{"tool":"check_values","says":"Has your user measured this? check_values sets each of their results beside every row held here, with a verdict and the row's cite.","arguments":{"place":"US-KS"},"needs":{"rows":"Your user's measured results, as their table prints them: [{parameter: \"aluminum\", value, unit}, ...], any other parameters too."},"post":"/api/v1/check","url":"https://passage-data.com/api/v1/check","page":"https://passage-data.com/limits/US-KS/aluminum#check"},{"tool":"read_certificate","says":"Has your user a laboratory certificate? read_certificate reads every row it prints, each with its page, and checks them against these limits.","arguments":{"place":"US-KS"},"needs":{"content_base64":"The laboratory's certificate (PDF) or its XLSX, XLS or CSV export, as base64; or file_url, a public https address of it."},"post":"/api/v1/certificate","url":"https://passage-data.com/api/v1/certificate","page":"https://passage-data.com/limits/US-KS/aluminum#check"}]}